Analytical Study on the Fire Resistance of SC Composite Column

SC 합성기둥의 내화성능에 대한 해석연구

  • 임윤희 ((주)동양구조안전기술 구조공학시스템연구소) ;
  • 강성덕 (고려대학교 대학원 건축공학과) ;
  • 오명호 (목포대학교 건설공학부) ;
  • 김명한 (대진대학교 건축공학과) ;
  • 김상대 (고려대학교 건축공학과)
  • Received : 2007.01.15
  • Accepted : 2007.04.09
  • Published : 2007.06.27

Abstract

The steel-concrete composite column (i.e., the SC composite column) supports large-gravity loads and simplifies the installation and removal of the work in pouring the concrete. The column takes advantage of the in-plant prefabrication of steel, the speed of erection of a steel structure, and the fire resistance of steel. This paper presents the results of a parametric study using heat transfer analysis and a P-M interaction curve, and compares these results with the experimental results to check the accuracy of the proposed parametric studies. The parametric studies, such as the study of the concrete ratio of an area and the fire protection thickness, provide information on the fire resistance of SC composite columns.

기존 합성기둥의 장점을 유지하면서 콘크리트 충전 시 거푸집 공사의 절감과 충전상태의 육안 확인이 가능한 철골 콘크리트 합성기둥(이하 SC 합성기둥)에 대한 연구가 활발히 진행되고 있다. SC 합성기둥은 콘크리트가 철골의 웨브를 둘러싸고 있어 화재 발생시 높은 열이 웨브까지 전달되는 시간을 지연시켜 뛰어난 내화성능을 가질 것으로 예상할 수 있다. 본 연구에서는 SC 합성기둥에 대해 열전달 해석을 수행하였고, 이를 바탕으로 P-M 상관 곡선을 이용하여 내화성능을 평가를 하였고, 이때의 해석변수는 콘크리트 면적비와 내화피복두께로 하였다. 또한 열전달 해석 방법을 검증하기 위해서 실제 수행된 실험 결과와 비교하여 이의 적절성을 검증하였다.

Keywords

References

  1. 김대곤, 김성훈, 김명관, 이규남, 김석회 (2001) 내화성능이 향 상된 H형강-국부콘크리트 합성기둥의 실험적 연구, 한국강구조학회 학술발표대회 논문집, 한국강구조학회, pp. 457-464
  2. 김성재, 박순전, 정석창, 김상대 (2002) Steel-Concrete Colum의 구조성능에 관한 실험 연구, 한국강구조학회 논문집, 한국강구조학회, 제 14권, 제 6호, pp. 389-396
  3. 오명호, 김평석, 김명한, 김대중, 김상대 (2004) 비조밀 단면을 사용한 SC합성 기둥의 압축 내력에 관한 실험적 연구, 대한건축학회 논문집(구조계), 대한건축학회, 제 20권, 제 10호, pp. 103-109
  4. 오명호, 김명한, 김대중, 김상대 (2005) 비조밀 단면을 가진 철 골-콘크리트 합성기둥의 비선형 해석, 대한건축학회 학술발표대회 논문집(구조계), 대한건축학회, 제 25권, 제 5호, pp. 147-150
  5. 오명호 (2005. 12) 비콤팩트단면 H형강-콘크리트 합성기둥의 구조적 거동에 관한 실험 연구, 박사학위논문, 고려대학교 건축공학과
  6. 이환수, 오명호, 김상대 (2003) 축력을 받는 SC 합성 기둥의 휨 성능에 관한 실험 연구, 한국강구조학회 논문집, 한국강구조학회, 제15권, 1호, pp. 87-96
  7. 김상대, 김명한, 오명호, 강성덕, 이승재 (2007) SC 합성기둥의 내화성능에 대한 실험연구, 한국강구조학회 논문집, 19(4),
  8. 정상진 (2003) 열전달해석, (주)태성에스엔이
  9. 정경수, 최성모, 김동규 (1997) 콘크리트 충전강관 기둥의 내화 특성에 관한 이론적 연구, 대한건축학회 추계학술발표대회 논문집(구조계), 대한건축학회, 제 17권, 제 2호, pp. 1179-1186
  10. 정경수, 최성모, 김동규 (2000) 화재시 중심축력을 받는 콘크리 트 충전 강관기둥의 내화 최대내력 추정식 제안, 대한건축학회 논문집(구조계), 대한건축학회, 제 16권, 제 6호, pp. 13-20
  11. British standards institution (1990) British standard structural use of steelwork in building: Part 8 code of practice for fire resistant design, BSI
  12. ENV (1994) Eurocode 4 Design of composite steel and concrete structures Part 1.1: General rules and rules for building, ENV
  13. ENV (1994) Eurocode 4-Design of composite steel and concrete structures-Part 1-2: General rules-Structural fire design, ENV
  14. G .M. Newman (1992) The fire resistance of webinfilled steel columns, The Steel Construction Institute, Technical report SCI publication 124
  15. ISO 834-1 (1999) Fire resistance tests - Elements of building construction and materials
  16. Jing Yin, Xiao-xiong Zha, Long-yuan Li (2006) Fire resistance of axially loaded concrete filled steel tube columns, Journal of Constructional Steel Research, Vol. 62, No. 7, pp. 723-729 https://doi.org/10.1016/j.jcsr.2005.11.011
  17. J. R. sharples, R. J. Plank, D. A. Nethercot (1994) Load-temperature-deformation behaviour of partially protected steel columns in fires, Journal of Engineering Structure, Vol. 116, No. 8, pp. 637-643
  18. KS F 2257-1, 건축 구조 부재의 내화 시험 방법-일반요구사항, 1999, 한국산업규격
  19. KS F 2257-7, 건축 구조 부재의 내화 시험 방법-기둥의 성능 조건, 2006, 한국산업규격
  20. KS F 2257-4, 건축 구조 부재의 내화 시험 방법-수직 내력 구 획 부재의 성능 조건, 2004, 한국산업규격
  21. Lin-Hai Han, Jing-si Huo (2003) Concrete-Filled Hollow Structural Steel Column after Exposure to ISO 834 Fire Standard, Journal of Structural Engineering, Vol. 129, No. 1, pp. 68-78 https://doi.org/10.1061/(ASCE)0733-9445(2003)129:1(68)
  22. Lin-Hai Han, Jing-si Huo, Yong-Chang Wang (2005) Compressive and flexural behaviour of concrete filled steel tubes after exposure to standard fire, Journal of Constructional Steel Research, Vol. 61, No. 7, pp. 882-901 https://doi.org/10.1016/j.jcsr.2004.12.005
  23. R. Tremblay (2002) Behavior and strength of partially encased composite columns with built-up shapes, Journal of Structural Engineering, Vol. 128, No. 3, pp. 279-288 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:3(279)
  24. X.X. Zha (2003) FE analysis of fire resistance of concrete filled CHS columns, Journal of Constructional Steel Research, Vol. 59, No. 6, pp. 769-779 https://doi.org/10.1016/S0143-974X(02)00059-7
  25. Y.C Wang (2000) A simple method for calculating the fire resistance of concrete-filled CHS columns, Journal of Constructional Steel Research, Vol. 54, No. 3, pp. 365-386 https://doi.org/10.1016/S0143-974X(99)00061-9
  26. Y. C. Wang (2002) Steel and Composite Structures: Behaviour and design for fire safety, Spon Press