• Title/Summary/Keyword: heating experiment

Search Result 868, Processing Time 0.027 seconds

The Application of Monitoring System Methods of Photovoltaic-Wind Power Generation for Railway Switching Point Heating Using LabVIEW (LabVIEW를 이용한 철도 선로전환기 융설용 태양광-풍력 발전 모니터링 시스템의 적용 방법)

  • Kim, Dae-Nyeon;Kim, Deok-Hyun;Choi, Jeong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.9-14
    • /
    • 2013
  • The monitoring system is an absolutely required system for improving a performance to consider the situation for the hybrid generation of the photovoltaic (PV) and wind power (WP) energy experimental research complex. This system is to monitor with the railroad switching point heating system using LabVIEW to the hybrid generation of the PV and WP. The monitoring system of this paper is a program monitoring the hour, day and total of the voltage and current that made from the hybrid generation of PV and WP. In experiment, we acquired the power data according to time at the day of PV and WP. We have confirmed the possibility of the real time monitoring system using LabVIEW with the railroad switching point heating system as the hybrid generation of the PV and WP.

The Effect of Temperature on Springback of AZ31, Ti-GR2 during V-bending with Focused Heating using Near-infrared Radiation (근적외선 집광가열 시 온도조건이 AZ31, Ti-GR2 소재 굽힘성형의 스프링백에 미치는 영향에 대한 실험적 연구)

  • Lee, E.H.;Hwang, J.S.;Lee, C.W.;Yang, D.Y.
    • Transactions of Materials Processing
    • /
    • v.23 no.8
    • /
    • pp.469-474
    • /
    • 2014
  • With the increased concerns of environmental issues, industries are paying more attention to lightweight metals. Because the high degree of springback is an obstacle to the widespread use of lightweight metals, many investigations have been conducted to reduce springback by increasing temperature. However, increasing the temperature of the whole die or the material is energy inefficient, since generally only a limited area of the material is deformed during sheet metal forming. As a solution to this problem, focused heating that only heats the area where plastic deformation occurs may be an alternative approach. In the current study, V-bending tests were conducted at various temperatures after the AZ31, Ti-GR2 sheets were locally heated using near-infrared (NIR) radiation in order to evaluate the effect of temperature on springback. The results of the experiment confirm that the NIR focused heating reduces the springback of AZ31, Ti-GR2 alloys with increasing temperature.

Technical Investigation into the In-situ Electron Backscatter Diffraction Analysis for the Recrystallization Study on Extra Low Carbon Steels

  • Kim, Ju-Heon;Kim, Dong-Ik;Kim, Jong Seok;Choi, Shi-Hoon;Yi, Kyung-Woo;Oh, Kyu Hwan
    • Applied Microscopy
    • /
    • v.43 no.2
    • /
    • pp.88-97
    • /
    • 2013
  • Technical investigation to figure out the problems arising during in-situ heating electron backscatter diffraction (EBSD) analysis inside scanning electron microscopy (SEM) was carried out. EBSD patterns were successfully acquired up to $830^{\circ}C$ without degradation of EBSD pattern quality in steels. Several technical problems such as image drift and surface microstructure pinning were taking place during in-situ experiments. Image drift problem was successfully prevented in constant current supplying mode. It was revealed that the surface pinning problem was resulted from the $TiO_2$ oxide particle formation during heating inside SEM chamber. Surface pinning phenomenon was fairly reduced by additional platinum and carbon multi-layer coating before in-situ heating experiment, furthermore was perfectly prevented by improvement of vacuum level of SEM chamber via leakage control. Plane view in-situ observation provides better understanding on the overall feature of recrystallization phenomena and cross sectional in-situ observation provides clearer understanding on the recrystallization mechanism.

Physiological Functionalities and Anti-oxidant activity of heated radish extract

  • Kim, Hyun-Kyoung
    • International journal of advanced smart convergence
    • /
    • v.7 no.2
    • /
    • pp.38-46
    • /
    • 2018
  • This study proceeded an experiment that can increase such physiological properties of heated radish extract. During the extraction of radish, including the byproduct, an increase in antioxidant properties of radish according the heating temperature was performed. Upon the extracts of radish bark and radish green extract(mucheong), the physiological functionalities and antioxidant activity were investigated. As a result, the color of radish ethanol extract in dependence of heating temperature, showed light brown color at low heating temperature and black color from $150^{\circ}C$. The total polyphenol content significantly increased as a result of heat treatment; 6.7 times and 22 times higher than the control at $110^{\circ}C$ and $150^{\circ}C$, respectively. DPPH radical scavenging ability and antioxidant property increased with increasing heating temperature; in comparison to heat-treated radish at $110^{\circ}C$ and $150^{\circ}C$, $IC_{50}$ decreased by 1/22 times. $IC_{50}$ of the control was 23times higher than $150^{\circ}C$ heat treated radish (Control $IC_{50}$:130.305). According to the graph that represents ABTS activity, antioxidant activity increased in dependence of heat treatment likewise to the total polyphenol content and DDPH radical scavenging activity. Upon heat treatment at $150^{\circ}C$, antioxidant activity in consequence of ABTS assay increased 23 times higher than the control.

Comparison of Forced Air Warming and Radiant Heating on Body Temperature and Shivering of Post-operative Patients (수술 후 가온방법에 따른 체온과 전율의 변화)

  • Choi, Kyoung-Hee
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.1
    • /
    • pp.135-148
    • /
    • 2008
  • Purpose: This study compared the effects of forced air warming and radiant heating on body temperature and shivering of patients with postoperative hypothermia. Methods: The quasi-experimental study was conducted with two experimental groups who had surgery under general anesthesia; 20 patients of group 1 experimented with the Bair Hugger as a forced air warming and 20 patients of group 2 experimented with the Radiant heater. The study was performed from July 3 to August 31, 2006 in a recovery room of an university hospital in a city. The effects of the experiment were measured by postoperative body temperature and chilling score at arrival and after every 10 minutes. The data were analyzed by t-test or ${\chi}^2$-test, repeated measures ANCOVA using SPSS/WIN 12.0. Results: The mean body temperature showed differences between the Bair Hugger group and Radiant Heater group at 40 minutes(F=-2.579, p=.034), 50minutes(F=-2.752, p=.027), and 60 minutes(F=-2.470, p=.047) after arrival to the recovery room. So, hypothesis 1 was partially accepted. The mean score of shivering showed differences between the Bair Hugger group and the Radiant Heater group, but it had no significant meaning. Hypothesis 2 was not accepted. Conclusion: We need more study to explore the effects and side effects of heating modalities to select a more effective heat treatment. The efficiency of heat modalities with regards to cost benefit, time consumption, and patients' discomfort such as burns should be considered.

  • PDF

Investigation of Heating Performance of Kerosene Fan Heater (석유 홴 히터의 난방 능력 고찰)

  • Kim, Jang-Kweon;Jeong, Kyu-Jo
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.51-60
    • /
    • 1997
  • In this paper, we investigated the heating performance and the basic characteristics required for normal combustion of kerosene fan heater. And also the iso-velocity contours and the iso-temperature contours of hot gas discharged from the exit of kerosene fan heater were analyzed. The experiment was carried out with kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of $240mm{\times}240mm{\times}1200mm$. The purpose of this paper was to obtain the basic data for new design from conventional kerosene fan heater. Consequently it was found that (i) the pressure ratio $P_2/P_1$ had a comparatively constant value of 0.844 according to the increase of the revolution of turbo fan, (ii) the primary excess air ratio had a range of $0.84{\sim}1.11$ during normal combustion, and (iii) the heating performance of kerosene fan heater had a range of $1,494{\sim}3,852kcal/hr$.

  • PDF

Mechanical Property and Process Variables Optimization of Tube-to-Tube Friction Welding for Steel Pipe with 36 mm External Diameter (외경 36mm 강관의 관대관 마찰용접 특성과 공정 변수 최적화)

  • Kong, Yu-Sik;Park, Young Whan
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.50-56
    • /
    • 2014
  • Friction welding is a very useful joining process to weld metals which have axially symmetric cross section. In this paper, for the friction welding with tube-to-tube shape, the feasibility of industry application was determined using analyzing mechanical properties of weld and optimized welding variables was suggested. In order to accomplish this object, rotating speed, friction heating pressure, and friction heating time were selected as the major process variables and the experiment was performed in three levels of each parameter. Weld characteristic was investigated in terms of weld shape and metal loss, and 7mm of metal loss was regarded as the optimal metal loss. By tensile test, tensile strength and yielding strength was measured and fracture was occurred at base metal. In order to optimize the welding condition, fitness function was defined with respect to metal loss and yielding strength and the fitness values for each welding condition could be calculated in experimental range. Consequently, we set the optimal welding condition as the point which had maximum value of fitness function. As the result of this paper the optimal welding variables could be suggested as rotating speed was 1300 rpm, friction heating pressure was 15 MPa, and friction heating time was 10 sec.

Thermal Performance Evaluation of Solar Hot Water System according to Flow Rate Control (유량제어방식에 따른 태양열 급탕시스템의 열성능 평가)

  • Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.140-145
    • /
    • 2011
  • In this study, the performance and behavior of solar heating system according to the system control scheme, variable flow control (proportional control) and constant flow control (on-off control) was carried out by experiment. The on-off control is used generally for solar thermal system by now. But the proportional control is used for the solar district heating system which is supplied the higher temperature of water than that of desired. The proportional control logic that pump speed is varied in an attempt to maintain a specified outlet temperature of solar heating system was developed and tested for the use widely for the small and medium solar thermal system. The results are as following. First, the proportional controller which is made here could be adopted the characteristics for setting temperature control. Second, the proportional control is better than the on-off control in the side of the performance of thermal stratification in storage tank. Third, the operating energy(electricity consumption by pump) of solar thermal system can be saved more than 60% using the proportional control comparing to the on-off control.

An Optimum Design of Pipe Bending Process Using High Frequency Induction Heating and Dynamic Reverse Moment (고주파 유도가열 및 동적 반력 모멘트를 이용한 파이프 벤딩 공정의 최적설계)

  • Lee, H.W.;Jung, S.Y.;Woo, T.K.;Kim, C.
    • Transactions of Materials Processing
    • /
    • v.19 no.2
    • /
    • pp.79-87
    • /
    • 2010
  • The Pipe bending process using high frequency local induction heating is an advanced technique to bend pipes with a small bending radius and a large diameter. Even though the pipe bending process is a quite widespread engineering practice, it depends heavily upon trial and error method by field engineers with several years of experience. So it is necessary to develop an integrated methodology for optimum design of the pipe bending process. During hot pipe bending using induction heating, outward wall thickness of a pipe is thinned due to tensile stress and the reduction of wall thickness is not allowed to exceed 12.5%. Taguchi method and dynamic reverse moment is proposed to maintain a reduction ratio of thickness within 12.5%, when D/t ratio is high. An application of the proposed approach was compared with those of the finite element analysis and has good in agreements.

Performance Analysis of Heating Nonslip using Solar Power Energy (태양광 에너지를 이용한 발열논슬립의 성능분석)

  • Moon, Jong Wook;Choe, Jae Won;Yun, Seok Heon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.55-61
    • /
    • 2018
  • This study aims to analyze the performance of Heated-nonslip using renewable energy to prevent nonslip freezing during winter. For this purpose, power generation system and congratulatory devices using solar energy are designed, and it is designed to provide regular electricity to heat up nonslip through Electrical storage system(ESS). In this study, It is intended to analyze the level of electrical energy suitable for nonslip using 24V or 48V, and to measure the temperature changes and temperature distribution according to the location of the test object. As a result of the experiment, nonslip's frame temperature was measured at $-7.5{\sim}-5^{\circ}C$ on average, and $-1{\sim}-2^{\circ}C$ on the heating cable during the supply of 24V and this could not be the solution for defrosting freezing nonslip in the winter. As a result of heating nonslip by supplying 48V with an electrical power of 8W, the temperature of the nonslip was shown to be between $5^{\circ}C$ and $11^{\circ}C$ to $13^{\circ}C$. Even if the power supply was switched on and off every minute, the temperature did not drop below $4^{\circ}C$ and the frozen ice melted on the nonslip without freezing.