• Title/Summary/Keyword: heating experiment

Search Result 868, Processing Time 0.027 seconds

An Experimental Study on the Exothermic Properties of Cement Mortar Containing Conductive Materials (전도성 재료를 혼입한 모르타르의 발열특성에 관한 실험적 연구)

  • Song, Dong-Geun;Hong, Chul-Ho;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.131-132
    • /
    • 2014
  • In this study, an experiment was carried out using graphite, conductive nickel powder, copper bar, carbon fiber for evaluate the exothermic properties and heating reproducibility of the cement mortar containing conductive material. As a result, the conductive materials that interfere with heating reproducibility are present, and the optimal conductive materials exist in each input voltage.

  • PDF

Elutriation and Production of Fines in a Fluidized Bed Coal Combustor (석탄유동층연소로에서 분진 발생 및 배출 특성)

  • 장현태;이종일
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.96-101
    • /
    • 1996
  • The effects of coal type and mixing fraction of coal on attrition and elutriation were studied in a 15. 5cm diameter fluidized bed coal combustor. The domestic low-grade anthracite coal with heating value 2010kcal/kg and the imported bituminous coal from Australia with heating value of 6520kcal/kg were used as coal sample. It was found from the experimental that the elutriation rate inclosed with an increseing anthracite mixing fraction. The size of elutriated particle had a very wide distribution was found in this experiment. The mean size of elutriated particle increased with decreaseing anthracite mixing fraction.

  • PDF

Experimental Study on Consumption of Energy and Heating Efficiency in Floor Water Heating System on Using Ondol Panel of Double Metal Rendering (이중금속융출형 온돌판넬을 이용한 바닥온수난방시스템의 난방성능과 에너지소비량에 관한 실험적 연구)

  • Bai, Dai-Kwon;Kim, Jin-Bong;Kim, Hwan-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6167-6175
    • /
    • 2012
  • This study is experimental analysis to verify heating efficiency of Ondol in floor heating panel developed. For this one, an experiment tests producing an each test speciment and measuring heating efficiency. The result of an experiment, supplying hot water temperature is $45^{\circ}C$ and the result of measuring on parts temperature of test speciment on supplying for 8 hours, mortar surface that is superstructure plumbing of heating system developed is $49.4^{\circ}C$, the gap of piping on center of mortar surface is $44.1^{\circ}C$ and airspace is proved $25.3^{\circ}C$. In floor structure of standards, mortar surface is $46.2^{\circ}C$, the gap of piping on center of mortar surface $37.7^{\circ}C$ and airspace is $24.7^{\circ}C$. On the other hand, energy consumption accumulating of development technology is identified, in case of hot-water supply on $45^{\circ}C$ as 4,646 kcal and in existing technology, as 4,814 kcal. developing technology is verified and lower than existing technology.

Experiment of Natural Circulation Loop Using a Cryocooler (극저온냉동기를 이용한 자연순환 루프의 실험)

  • Kim, M.J.;Chang, H.M.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2194-2199
    • /
    • 2007
  • An experimental study is performed to investigate the thermal and flow characteristics of subcooled liquid nitrogen in a natural circulation loop. Experimental apparatus is designed and constructed such that a closed loop is cooled at the top by a cryocooler and heated nearly at the bottom by cartridge heaters. Steady state is obtained by controlling the heating power to the cartridge heaters and a thin-film heater to reduce the cooling power of the cryocooler. Temperature is measured at several locations of the loop and the mass flow rate through the loop is estimated from the energy balance in terms of the measured temperatures. Experiment is repeated for various values of the vertical height between the cooling and heating parts. The results show that the heat transfer capability of the loop has a maximum at a certain value of height. The optimal height to maximize the heat transfer is in a good agreement with analytical prediction to take into account the buoyancy and viscous forces in the loop.

  • PDF

Changes in Allergenicity and Digestibility of Egg and Milk by Heat Treatment (가열처리에 따른 우유와 달걀의 Allegenicity의 변화와 소화율에 관한 연구)

    • Journal of the East Asian Society of Dietary Life
    • /
    • v.11 no.2
    • /
    • pp.104-111
    • /
    • 2001
  • The first purpose of this study was to determine the changes in the allergenicity of milk and egg with heat treatment. The allergenicity of milk and egg is known to have a strong antigen. The second purpose of this study was to observe changes of disestibility of milk and egg after heat treatment. For this study, passive cutaneous anaphylaxis(PCA) inhibition experiment by using guinea pig and nonprotein nitrogen(NPN)experiment were attempted. The result were following: 1. The allergenicity of both milk and egg was reduced by heat treatment. 2. The degree of hydrolysis and PCA inhibition increased with longer heating time. 3. The increse in both the degree of hydrolysis and PCA inhibition of milk was higher than that of egg. 4. Egg contained a greater amount of allergen than milk after heat treatment. 5. The digestibility of both milk and egg was reduced by heat treatment. 6. The digestibility was reduced further by increasing heating time. 7. The digestibility of egg was lower than that of milk after the treatment.

  • PDF

A study on heat transfer characteristics and pressure drop of heat transfer by baffle cut rate (배플 플레이트를 갖는 열교환기의 열전달 및 압력강하에 관한 연구)

  • Bae, Sung-Woo;Choi, Soon-Ho;Yoon, Seok-Hoon;Oh, Cheol
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.172-177
    • /
    • 2005
  • The object of this experiment is comparing heat transfer performance and pressure drop characteristics by baffle cut rate, fluid velocity and heating temperature. Experiments were carried out in cross flow heat exchanger with water as a working fluid. In this experiment, baffle cut rate is 30%, 40%, 50%, velocity is 0.5m/s, 1.0m/s, 1.5m/s, and heating temperature is $30^{\circ}C$, $40^{\circ}C$, $50^{\circ}C$. An experimental device to measure the heat transfer coefficient was constructed. The experimental result were obtained for the fully developed turbulent flow of water in tube on the condition of uniform heat flux.

  • PDF

Development of Temperature Controller for Seedbed Heating System (묘상 난방 시스템을 위한 온도제어기 개발)

  • Park, Jung-Hoon;Hong, Sung-Hoon;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2301-2303
    • /
    • 2002
  • This paper describes the development of temperature controller for seedbed heating system. This system consisted of three parts; sensing part, control part that includes the PID control algorithm, and actuating part. The control part introduced a phase angle control method of TRIAC and firmware technique using one-chip microcontroller(PIC16C73). For evaluating the performance of a PID control system, the experiment results by a developed controller are compared with these obtained from a conventional controller which utilize ON-OFF control method. The experiment results show that the proposed controller has good control performance.

  • PDF

Effects of Heating on Hydroxyl Radical-Generated Toxicity in Mouse Forebrain Tissue Culture

  • Lee, Jeong-Chae;Lim, Kye-Taek
    • Toxicological Research
    • /
    • v.14 no.3
    • /
    • pp.301-306
    • /
    • 1998
  • This experiment was carrid out to know the effects of heating and serum on hydroxyl radicals in embryonic mouse forebrain (cerebrum) culture. The heating to mouse embryonic cerebrum cells in culture was done in a water bath at 43${\circ}C$ for 60min. After that, two supernatants were prepared at 20 hrs and 48 hrs respectively after heat treatment to the brain cells. To find out the heating effects on neuron cells, mouse cerebrum cells (13 embryonic day) were cultured in hydroxyl radical generation system composed of 20mU/ml glucose oxidase (GO system), using condition of normal culture media (MEM, 5% serum, 5% $CO_2$or supernatant prepared after heating at 43${\circ}C$ for 60 min in a water bath. Supernatant prepared at 20 hrs after heat treatment had a greater protective effects against hydroxyl radical than supernatant prepared at 48 hrs after heat treatment . Otherwise, the protective effect of serum against hydroxyl radicals in the cultured brain cells is higher than that in the heat treatment. These results indicated that serum in culture media reduced cytotoxicity of hydroxyl radicals in mouse forebrain culture, also that heat treatment showed the protective effects against hydroxyl radicals generated with 20mU/ml GO system in mouse forebrain culture.

  • PDF

An Experimental Study of Solar fir Roof Heating System With PVT Collector (공기식 집열 지붕 난방시스템의 실험 연구)

  • Kang, Jun-Gu;Kim, Jin-Hee;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.232-237
    • /
    • 2008
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This research is about the development of solar roof system with PV/T collector to apply into buildings. A test cell experiment was performed with the PVT roof installed: It found that the hot air supply from the PVT air collector contributed to increase the heating efficiency by 2 times and the electrical efficiency by about 8%.

  • PDF

An Experimental Study on Heat Transfer Performance of Heating Medium Oil Fluidized Bed Heat Exchanger (열매체유 유동층 열교환기의 전열성능에 대한 실험적 연구)

  • Park, Sang-Il;Ko, Chang-Bok;Lee, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.146-151
    • /
    • 2015
  • The heat transfer performance of heating medium oil fluidized bed heat exchanger was measured. The operation variables were air flow rate, air inlet temperature, moisture content, water flow rate and water inlet temperature. The outside heat transfer coefficient was determined from the heat exchanger experiment and its experimental correlation was determined as a function of air velocity and viscosity of heating medium oil. Effect of viscosity was well agreed with the previous studies. Errors of the correlation equation was less than about 10% for outside heat transfer coefficient developed in this study when compared with the measured value. Hot water with the temperature greater than $77^{\circ}C$ could be produced by using the heating medium oil fluidized bed heat exchanger.