• 제목/요약/키워드: heating and cooling load

검색결과 385건 처리시간 0.023초

창원시 학교 건축물의 냉난방부하에 대한 전력 소비량 추정에 관한 연구 (A Study on Prediction of Power Consumption Rate for Heating and Cooling load of School Building in Changwon City)

  • 박효석;최정민;조성우
    • 교육녹색환경연구
    • /
    • 제11권2호
    • /
    • pp.19-27
    • /
    • 2012
  • This study was carried out in order to establish the estimation equation for school power consumption using regression analysis based on collected power consumption for two years of weather data and schools are located in Central Changwon and Masan district in Changwon city. (1) The power consumption estimation equation for Heating and cooling is calculated using power consumption per unit volume, the difference between actual power consumption and results of estimation equations is 4.1%. (2) The power consumption estimation equation for heating load is showed 2.6% difference compared to actual power consumption in Central Changwon and is expressed 2.9% difference compared to that in Masan district. Therefore, the power consumption prediction for each school using the power consumption estimation equation is possible. (3) The power consumption estimation equation for cooling load is showed 8.0% difference compared to actual power consumption in Central Changwon and is expressed 2.9% compared to that in Masan district. As the power consumption estimation equation for cooling load is expressed difference compared to heating load, it needs to investigate influence for cooling load.

조명발열 배기시스템의 배기위치에 따른 배기열량 실험연구 (A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting)

  • 오병길;정민호;원종서;이훈
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2013
  • This study aims to reduce cooling energy by grasping kinds of heating load in building in order to decrease cooling energy in summer and eliminate efficiently heating load. Lighting heating value was confirmed through examination and experiment concerning lighting heating and reducible exhaustion value was extracted lighting apparatus. The optimal exhaust system by air conditioning type was suggested for applying lighting heat exhaust system and the method contributing to promotion supplying low energy architecture was suggested by predicting reduced cooling load.

우리나라의 기후 변화 영향에 의한 건물 냉난방에너지 수요량 변화의 예측 (Prediction on Variation of Building Heating and Cooling Energy Demand According to the Climate Change Impacts in Korea)

  • 김지혜;김의종;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.789-794
    • /
    • 2006
  • The potential impacts of climate change on heating and cooling energy demand were investigated by means of transient building energy simulations and hourly weather data scenarios for Inchon. Future trends for the 21 st century was assessed based oil climate change scenarios with 7 global climate models(GCMs), We constructed hourly weather data from monthly temperatures and total incident solar radiation ($W/m^2$) and then simulated heating and cooling load by Trnsys 16 for Inchon. For 2004-2080, the selected scenarios made by IPCC foresaw a $3.7-5.8^{\circ}C$rise in mean annual air temperature. In 2004-2080, the annual cooling load for a apartment with internal heat gains increased by 75-165% while the heating load fell by 52-71%. Our analysis showed widely varying shifts in future energy demand depending on the season. Heating costs will significantly decrease whereas more expensive electrical energy will be needed of air conditioning during the summer.

  • PDF

베네치안 블라인드의 슬래트 각도변화가 건물의 냉난방 부하에 미치는 영향 (The Effect on the Heating and Cooling Load of Building by Slat Angle Variation of Venetian Blind)

  • 조성환;신기식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.171-183
    • /
    • 1995
  • Generally, among many kinds of shading devices such as venetian blind, sunscreen, louver and curtain, venetian blind is using widely because the mechanism is so simple and easy to use solar insolation by controlling the slat angle. Analysis of time dependent heat transfer through the window with venetian blind is very important in order to use it effectivly. Therefore, in this study, theoretical thermal analysis method was developed to analyze time dependent heat transfer through a double pane window with and without venetian blind, and was made one module of TRNSYS(A Transient Simulation Program)program. By this way, it was analyzed that how much the variation of slat angle, slat colour and slat absorptivity of venetian blind would be affected on the heating and cooling load of building, and also which colour and angle of slat was optimal for the heating and cooling load of building.

  • PDF

냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구 (A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load)

  • 안형준;김영탁;최창호;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.77-87
    • /
    • 2004
  • BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.

주택에서의 단열성능 강화가 냉난방부하에 미치는 영향 (The Strengthening Effect of the Heating and Cooling Load on the Thermal Performance in the Housing Unit)

  • 이준기;김성훈;이갑택;이경희
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.483-488
    • /
    • 2016
  • In this study, we chose the rural house as a standard model. In order to review the energy difference of cooling and heating loads, we changed the thermal transmittance standards. By using the thermal transmittance standard in 2011 as the Basic CASE, the thermal transmittance standard in 2013 as well as 2016, and the thermal transmittance standard of passive houses, we compared the results with regard to the cooling and heating energy load. Because of the heat loss, it can be confirmed that with an improved thermal performance of the building structure, the maximum increase of the cooling energy load was 36 kWh from June to September. Because of the heat loss, it was also confirmed that with the improved thermal performance of a building structure, the maximum decrease of the heating energy load is 1,498 kWh from November to April. Even though the heat loss of the building structure could decrease the cooling energy load by improving thermal transmittance standards in Korea, the energy saving performance is worse than the situation of heating energy load in heating period. Compared with CASE 1 and CASE 2, as well as CASE 1 and CASE 3, we CASE 3 was found to have the best energy saving rate when compared to the other cases : CASE 3 increased by 1,452 kWh and CASE 2 by 588 kWh, because the window thermal transmittance standard of 2016 was added.

Energy Performance and Improvement in University Library - Concentrated on 'K'University Library located in Seojong City -

  • Roh, Ji Woong
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.47-52
    • /
    • 2014
  • The problem of energy consumption is more serious in university buildings than primary, middle and high school buildings. Because university buildings have generally heating and cooling systems, and various incidental facilities. In university, the library is one of the building that many people use and the most energy is spent. So, investigation on energy saving is very important and urgent. This study aims finally to present the guideline for low-energy design of University library by aiding a designer to select best solution in the side of energy-saving. In this paper, composition of space, utilization schedule and performance of construction materials are grasped, some primary factors that effect to energy saving are analyzed by energy simulation. The result of this study is as follows; First, the subject library has more cooling load than heating load because of cooling load generated during middle season. Second, green roofs is the most effective to heating load saving, but not to cooling energy. Third, outdoor air cooling is the most effective to cooling energy saving among the investigated strategies included in this study.

TAC를 반영한 BIN 데이터 기반의 냉난방 부하 변화에 관한 연구 (Heating and Cooling Load Evaluation Study with TAC Based BIN Data)

  • 이광섭;김유진;민경천;이의준;강은철
    • 설비공학논문집
    • /
    • 제29권9호
    • /
    • pp.463-471
    • /
    • 2017
  • According to the Korea industrial standard of air conditioning systems (KS C 9306), cooling and heating loads for buildings can be calculated by using maximum and minimum temperature in BIN data. Cooling and heating loads can be determined by building set temperature and ambient temperature. Cooling and heating system capacity of buildings can be normally designed according to determined heating and cooling loads. Cooling and heating system capacity can be reduced by updated BIN data, applying TAC (Technical Advisory Committee) values. In this study, updated BIN data have been analyzed using ambient temperature of 19 areas in Korea for the last 10 years (2005~2014) provided by KMA (Korea Meteorological Administration). Building cooling and heating loads have been calculated following TAC based BIN data. As a result, designed system capacity decreased depending on applying TAC. Those were reduced as 7.1% ($100m^2$ building), 8.7% ($1,000m^2$ building) in cooling capacity, 11.7% in heating capacity when TAC 2.5% applied. And also, it is expected system initial and operating cost by decreasing system capacity.

국내 공동주택의 에너지절약 설계기준 강화에 따른 냉난방설비 설계 기준 개선 방안 (Improvement of Design Criteria in Heating and Cooling Equipment According to the Consolidation of Design Standard for Energy Saving in Apartment Buildings of Korea)

  • 임재한;김성임;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.89-97
    • /
    • 2014
  • Recently design standard for energy-saving in apartment buildings has been consolidated gradually on the basis of evaluation and certification standards of energy efficiency of buildings, the energy-saving policy of building at home and abroad. Performance criteria for thennal insulation as well as fenestration has been progressively enhanced, and performance criteria for ventilation and airtightness of the building have also been re-developed. Therefore, heating and cooling load characteristics of the apartment building can be changed. For the design of the upcoming heating and cooling equipment in apartment buildings, it is necessary to evaluate the heating and cooling load characteristics according to the design strategies for energy saving in apartment buildings. As a result, in this study, it is intended to use as a resource for analyzing the impact that the adoption of energy-saving design variables for each of the apartment buildings, to predict the heating and cooling load characteristics in the apartment building.

국내 건물 단열기준에 따른 냉.난방 부하 분석 및 최적 단열기준에 관한 고찰 (An Analysis of Thermal Loads Depending on Korea Building Insulation Standard and the Optimum Insulation Standard)

  • 서성모;박진철;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.146-155
    • /
    • 2011
  • Sustainable building is getting more and more important topic in 21C. Following this trend, building energy saving standard has been reinforced in Korea. Especially, insulation standards are revised continuously after1979. This study aims to evaluate the correlation between the revised insulation standards and heating and cooling loads of a residential building. This study shows that the standard of insulation is more related with heating load than cooling load, and cooling load is more related with other sources such as glass types and solar incidence through windows. In case of highly-insulated building such Passive Houses or Zero Energy Houses, the cooling load should also be considered as important as heating load when revising the building energy saving regulations in the future.