• 제목/요약/키워드: heater

검색결과 1,744건 처리시간 0.027초

전기발열시트에 의한 한중콘크리트의 양생 및 온도이력에 관한 실험 연구 (An Experimental Study on the Curing and Temperature History of Cold Weather Concrete by Planar Surface Heater)

  • 김형래;조호규;김찬수;지남용
    • 한국건축시공학회지
    • /
    • 제3권2호
    • /
    • pp.135-139
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete cured with heating sheets in the laboratory conditions. As the results, It was showed that the 130W/$m^2$-heater could raise the inner temperature more than $20^{\circ}C$ under the environmental condition of -5~$-20^{\circ}C$. And the temperature of concrete cured by the 200W/$m^2$-heater was 5~$10^{\circ}C$ higher than that of concrete cured by 130W/$m^2$-heater. Finally, through the curing by the planar surface heater during the first 1.5~2 days, it is possible to secure the sufficient maturity of concrete.

전기히터식 및 지열원 히트펌프식 농산물 열풍건조기의 에너지 성능 비교 (Energy Performance Comparison of Electric Heater and Geothermal Source Heat Pump type Agricultural Hot Air Dryers)

  • 양원석;김영일;박승태
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.7-12
    • /
    • 2018
  • Energy performance of electric heater and geothermal source heat pump type hot air dryers are compared in this study. For set temperatures of $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$, radish is dried from initial mass 60 kg until it gets 5 kg, where the difference equals the amount of water removed. As set temperature is increased, drying time is shortened for both electric heater and heat pump types, however energy efficiency is decreased due to increasing electricity consumption. Moisture extraction rate(MER) of electric heater is 2.58~2.84 kg/h, and for heat pump type 2.56~2.71 kg/h, showing little difference between the two types. Specific moisture extraction rate (SMER) of electric heater is 0.94~0.96 kg/kWh, and for heat pump type 1.72~2.21 kg/kWh. SMER of heat pump type is greater by 0.78~1.25 kg/kWh than the electric heater hot air dryer, which is 1.8~2.3 times better in terms of energy efficiency.

Experimental study of bubble behaviors and CHF on printed circuit board (PCB) in saturated pool water at various inclination angles

  • Tanjung, Elvira F.;Alunda, Bernard O.;Lee, Yong Joong;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1068-1078
    • /
    • 2018
  • Experiments were performed to investigate bubble behaviors and pool boiling Critical Heat Flux (CHF) on a thin flat rectangular copper heater fabricated on Printed Circuit Board (PCB), at various inclination angles. The surface inclination angles were $0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$, and $180^{\circ}$. Results showed the Onset of Nucleate Boiling (ONB) heat flux increased with increasing heater orientation from $0^{\circ}$ to $90^{\circ}$, while early ONB occurred when the heater faced downwards ($135^{\circ}$ and $180^{\circ}$). The nucleate boiling was observed to be unstable at low heat flux (1-21% of CHF) and changed into typical boiling when the heat flux was above 21% of CHF. The result shows the CHF decreased with increasing heater orientation from $0^{\circ}$ to $180^{\circ}$. In addition, the bubble departure diameter at the heater facing upwards ($0^{\circ}$, $45^{\circ}$, and $90^{\circ}$) was more prominent compared to that of the heater facing downward ($135^{\circ}$). The nucleation site density also observed increased with increasing heat flux. Moreover, the departed bubbles with larger size were observed to require a longer time to re-heat and activate new nucleation sites. These results proved that the ONB, CHF, and bubble dynamics were strongly dependent on the heater surface orientation.

발전소 과열증기 온도제어 시스템의 국산 DCS 적용에 관한 연구 (Study on application of domestic development DCS for S/H temp in the power plant)

  • 박익수;김은기;박성혁;이기원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.292-296
    • /
    • 1992
  • There are lots of disturbance in the super heater temperature control system of power plant boiler as follows. 1.Burner light off. 2.Excess Air. 3.Burner tilt. 4.G.R fan flow. Temperature control system of super heater in the power plant has delay time about 5 min. So it is difficult to control the super heater temperature in the power plant. This paper show us the application of domestic development DCS to control the super heater temperature in seoul #5 thermal power plant unit.

  • PDF

온풍난방기 성능 개선 연구 (I) - 송풍방식에 따른 송풍성능 비교 - (Improvement of Space Heater (I) - Comparison of Blowing Performance for Blowing Type -)

  • 권순홍;정성원;이승기
    • 한국산업융합학회 논문집
    • /
    • 제3권3호
    • /
    • pp.245-250
    • /
    • 2000
  • This study was carried out to investigate blowing performance for blowing type in space heater. This paper present that power requirement, static pressure, total pressure and static pressure efficiency were increased in proportion to air flow rate. And in the Korean space heater, side ward blowing type was effected than downward blowing type.

  • PDF

히터온도 제어용 변압기-SCR 전력변환장치 제어 기법 (Control techniques of transformer - SCR power regulator for heater temperature control)

  • 후인안뚜언;전태원;이홍희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.265-266
    • /
    • 2019
  • This paper proposed a three-channel transformer-type power regulator to control the heater temperature by adjusting the voltage across the heater for pre-heating and the post-heating procedures of the material welding. The experimental results are carried out to verify the performance of three-channel heater temperature control for the heat treatment.

  • PDF

태양열과 재열기를 사용한 VI heat pump의 성능 특성에 관한 연구 (Heating Performance Characteristics of Heat Pump with VI cycle using Re-Heater and Solar-Assisted)

  • 이진국;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권6호
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, heating performance of the air-cooled heat pump with vapor-injection (VI) cycles, re-heater and solar heat storage tank was investigated experimentally. Devices used in the experiment were comprised of a VI compressor, re-heater, economizer, variable evaporator, flat-plate solar collector for hot water, thermal storage tank, etc. As working fluid, refrigerant R410A for heat pump and propylene glycol (PG) for solar collector were used. In this experiment, heating performance was compared by three cycles, A, B and C. In case of Cycle B, heat exchange was conducted between VI suction refrigerant and inlet refrigerant of condenser by re-heater (Re-heater in Fig. 3, No. 3) (Cycle B), and Cycle A was not use re-heater on the same operating conditions. In case of Cycle C, outlet refrigerant from evaporator go to thermal storage tank for getting a thermal energy from solar thermal storage tank while re-heater also used. As a result, Cycle C reached the target temperature of water in a shorter time than Cycle B and Cycle A. In addition, it was founded that, as for the coefficient of heating performance($COP_h$), the performance in Cycle C was improved by 13.6% higher than the performance of Cycle B shown the average $COP_h$ of 3.0 and by 18.9% higher than the performance of Cycle A shown the average $COP_h$ of 2.86. From this results, It was confirmed that the performance of heat pump system with refrigerant re-heater and VI cycle can be improved by applying solar thermal energy as an auxiliary heat source.

Gas air heater 시스템 소개 (Introduction of Gas Air Heater)

  • 한승철;김종규;사공운곤
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.15-16
    • /
    • 2006
  • LNGC 에 Gas Air Heater를 적용함에 따라 Market 경쟁력 확보 및 System의 효율 개선을 통한 DSME 만의 독창력 확보.

  • PDF

Mechanical Properties of Polypropylene Filaments Drawn on Varying Post Spinning Temperature Gradients

  • Mukhopadhyay, S.;Deopura, B.L.;Alagirusamy, R.
    • Fibers and Polymers
    • /
    • 제7권4호
    • /
    • pp.432-435
    • /
    • 2006
  • High Modulus and high tenacity polypropylene fibers have been prepared by drawing on a gradient heater. Results show that fiber properties are significantly affected by temperature profiles of final stage drawing on a gradient heater. The gradient drawn filaments showed superior mechanical properties when compared to filaments drawn over a constant temperature heater. Fibers with initial modulus of 16.4 GPa and tenacity of 670 MPa have been manufactured in the process. The nature of the gradient drawing had a significant effect on end properties. The superior mechanical properties are attributed to the high crystal perfection and crystallinity and low void fractions obtained at high draw ratios when drawn over a gradient heater.

열성형 과정에서 반응면 기법을 이용한 히터의 비정상 최적제어에 관한 연구 (A Study on Time-Dependent Optimal Heater Control for Thermoforming Using Response Surface Method)

  • 리진철;허광수;설승윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2528-2533
    • /
    • 2007
  • Thermoforming is one of the most versatile and economical processes available for the manufacturing polymer products. The drawback of thermoforming is difficult to get uniform thickness of final products. For the distribution of thickness strongly depends on the temperature distribution of sheet, the adjustment of heater power is very important In this paper, an optimization study for getting uniform temperature distribution was carried out using dual optimization steps. At first, the steady state optimal distribution of heater power is searched by numerical optimization to get uniform temperature of sheet surface. In the second step, time-dependent optimal heater inputs have been found out to decrease the temperature difference through the direction of thickness using Rseponse Surface Method and D-optimal method. The optimization results show that the time-dependent optimal heater power distribution gives acceptable uniform sheet temperature in the field of forming temperature..

  • PDF