• Title/Summary/Keyword: heat-wave data

Search Result 145, Processing Time 0.027 seconds

A Case Study on the Heat budget of the Marine Atmosphere Boundary Layer due to inflow of cloud on observation at Ulleungdo (울릉도에서 구름 유입시 관측한 해양대기경계층의 열수지에 관한 사례연구)

  • Kim, Hee-Jong;Yoon, Ill-Hee;Kwon, Byung-Hyuk
    • Journal of the Korean earth science society
    • /
    • v.25 no.7
    • /
    • pp.629-636
    • /
    • 2004
  • In order to study developments of the marine atmosphere boundary layer in cloud incoming, important parameters like heat advection, surface layer heat flux, and radiation energy were estimated using the rawinsonde, AWS data, satellite images, and buoy data which was installed at the East Sea. We explained the variation and the development of mixed layer in terms of surface layer heat flux and long wave radiation under the cloudy sky. The heat flux was obtained by means of the bulk method. Conservation of heat was analysed by heat budget equation, which was consist of buoy data in the East sea, and sounding data at Ulleungdo and at Pohang. During the inflow of cloud, radiative cooling at the surface after was suppressed and long wave radiation from cloud played a role of warming. The surface layer temperature was also remained warm by influence of warm advection from south-easterly direction. The air temperature in night was increased, as a result, mixed layer was not destroyed and The nocturnal boundary layer was composed of the mixed layer and the residual layer.

A Study on Smart Heat Radiating Sheet for Protecting Electronic Equipments on the Ship

  • Choi, Dong-Soo;Kim, Dong-Il;Kim, Doh-Yeol;Choi, Dong-Han;Kil, Gyung-Suk;Kim, Jae-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.35 no.7
    • /
    • pp.569-573
    • /
    • 2011
  • In this paper, we developed a Smart Heat Radiating Sheet(SHRS) having the absorption ability of more than 15 dB, and thermal conduction rate more than 20 W/mk for port logistics RFID(Radio Frequency IDentification) system by using AMP(Amorphous Metal Powder) and shielding sheet. Firstly, the EM(Electro_Magnetic) wave absorber samples were fabricated by using AMP and CPE (Chlorinated Polyethylene) with different composition ratios of 80 : 20 wt.% and 85 : 15 wt.%, respectively. Secondly, we fabricated the Smart Heat Radiating Sheet using the shielding sheet to attach EM Wave Absorber. As a result, the Smart Heat Radiating Sheet with absorption ability of 16 dB at 433 MHz and thermal conduction rate is 24 W/mk has been developed with the composition ratio of Amorphous Metal Powder : CPE = 85 : 15 wt.% and thickness of 5.5 mm.

Application of WAVE Modeling in Combustion performance of SI Engines Using DoE Methodology (실험계획법과 WAVE 시뮬레이션을 이용한 엔진 작동 변수의 영향도 평가 및 최적화에 대한 연구)

  • Jeong, Dong-Won;Tsogtjargal, Tsogtjargal;Soyoloo, Soyoloo;Lim, Ock-Taeck
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2922-2927
    • /
    • 2008
  • The test of engine performance using the engine dynamometer needs technical researchers and facilities. A variety of CAE analysis programs and DoE(Design of Experiments) are used to analyze data efficiently instead of tests. The study got data from simulations of WAVE that used to model the SI engine to identify performance of engine. DoE makes it possible to know effectiveness of factors for power, BSFC, volume efficiency and find optimum condition in each factor through minimizing number of experiments. CA50 has effect on power and BSFC as volume efficiency is related with cylinder liner temperature and heat coefficients. The final result in DoE could be identified of consistency above 98% after substituting the data to WAVE.

  • PDF

Development of Clinical Protocol for Acquisition of Change of Radial Pulse Wave Signal in the Cold-Heat Intervention: Explanatory, Randomized, 2×2 cross-over design (냉온 부하에 따른 요골동맥 맥파의 변화 특성을 파악하기 위한 무작위 배정·2×2교차설계 탐색적 임상시험계획서 개발)

  • Yu, Hana;Kim, Jihye;Ku, Boncho;Kim, Hyunho;Jeon, Youngju
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.2
    • /
    • pp.91-100
    • /
    • 2015
  • Objectives The aim of this study is to develop a structured clinical protocol related with acquisition of radial pulse wave in the randomized, $2{\times}2$ cross-over design, and cold-heat intervention trial for a pilot and preliminary study. Methods The protocol was contrived based on wide ranging literature searches for cold-heat intervention experiments and radial pulse diagnoses. Results Sample size of 60 subjects was calculated based on an effect size derived from the previous study designed to detect the pre-post cold-heat differences in the radial pulse. Each subjects will be randomly assigned to the cold (first) to heat (last) group (n=30) or heat (first) to cold (last) group (n=30). All subjects will fill out a case report form and questionnaires related with pattern identification, dietary patterns, sleep quality, and physical activity will be surveyed and used as a secondary outcomes. Safety assessment will be reported at the final stage. Conclusions This protocol will provide an additional reference to future studies related with observation of radial pulse during any interventions and also expect to be used as a guideline for acquisition of reliable radial pulse wave data.

Mean Heat Flux at the Port of Yeosu (여수항의 평균 열플럭스)

  • Choi Yong-Kyu;Yang Jun-Hyuk
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.653-657
    • /
    • 2006
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) data from National Fisheries Research and Development Institute (NFRDI) (1995-2004), mean heat fluxes were estimated at the port of Yeosu. Net heat flux was transported from the air to the sea surface during February to September, and it amounts to $205 Wm^{-2}$ in daily average value in May. During October to January, the transfer of net heat flux was conversed from the sea surface to the air with $-70 Wm^{-2}$ in minimum of daily average value in December. Short wave radiation was ranged from $167 Wm^{-2}$ in December to $300 Wm^{-2}$ in April. Long wave radiation (Sensible heat) was ranged from $27 (-14) Wm^{-2}$ in July to $90 (79) Wm^{-2}$ in December. Latent heat showed $42 Wm^{-2}$ with its minimum in July and $104 Wm^{-2}$ with its maximum in October in daily average value.

The development of ultrasonic transmitter to enhance the efficiency of heat transfer rate in boiler (보일러내 열 전달 효율 개선을 위한 초음파발신기 개발)

  • Heo, Pil-Woo;Lee, Yang-Lae;Lim, Eui-Su;Koh, Kwang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.95-101
    • /
    • 2003
  • Ultrasonic transmitter used for scale prevention in boiler or heat exchanger is composed of the magnetostrictive material which transforms electric energy into ultrasonic wave and the horn which amplifies generated ultrasonic wave and transfers it into medium loaded. In this paper, we have performed the shape design for magnetostrictive material and analyzed a few type of horns which amplify generated ultrasonic wave and found each solution theoretically. Final length of the horn has been determined by measuring the sound pressure in medium between theoretical value and experience data. At last we have given the results of our study for the effects of ultrasonic wave irradiated by manufactured ultrasonic transmitter on preventing scale deposition on test pipe under the similar condition to boiler.

Characteristics and Comparison of 2016 and 2018 Heat Wave in Korea (2016년과 2018년 한반도 폭염의 특징 비교와 분석)

  • Lee, Hee-Dong;Min, Ki-Hong;Bae, Jeong-Ho;Cha, Dong-Hyun
    • Atmosphere
    • /
    • v.30 no.1
    • /
    • pp.1-15
    • /
    • 2020
  • This study analyzed and compared development mechanisms leading to heat waves of 2016 and 2018 in Korea. The European Centre for Medium-Range Weather Forecasts Reanalysis Interim (ERA Interim) dataset and Automated Surface Observing System data are used for synoptic scale analysis. The synoptic conditions are investigated using geopotential height, temperature, equivalent potential temperature, thickness, potential vorticity, omega, outgoing longwave radiation, and blocking index, etc. Heat waves in South Korea occur in relation to Western North Pacific Subtropical High (WNPSH) pressure system which moves northwestward to East Asia during summer season. Especially in 2018, WNPSH intensified due to strong large-scale circulation associated with convective activities in the Philippine Sea, and moved farther north to Korea when compared to 2016. In addition, the Tibetan high near the tropopause settled over Northern China on top of WNPSH creating a very strong anticyclonic structure in the upper-level over the Korean Peninsula. Unlike 2018, WNPSH was weaker and centered over the East China Sea in 2016. Analysis of blocking indices show wide blocking phenomena over the North Pacific and the Eurasian continent during heat wave event in both years. The strong upper-level ridge which was positioned zonally near 60°N, made the WNPSH over the South Korea stagnant in both years. Analysis of heat wave intensity (HWI) and duration (HWD) show that HWI and HWD in 2018 was both strong leading to extreme high temperatures. In 2016 however, HWI was relatively weak compared to HWD. The longevity of HWD is attributed to atmosphere blocking in the surrounding Eurasian continent.

COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE (Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교)

  • Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.491-497
    • /
    • 2007
  • The purpose of this study was to compare apical sealing ability of continuous wave canal filling technique according to various heat source plugging depths. Eighty one extracted human premolars with straight root were cleaned and shaped to size 35 using .06 taper rotary NiTi file. After cleansing and shaping, the teeth were divided into 5 groups following the heat source probing depths from the apex; 3, 4, 5, 6 and 7 mm. All specimens were filled using E&Q plus with #35/.06 tapered gutta-percha cone. The positive control teeth were not filled. All teeth were coated with nail varnish except the apical 1 mm around the apical foramen. Negative control teeth were completely sealed include the apical foramen. All specimens were immersed in 1% methylene blue solution for 72 hours. Then the specimens were sectioned horizontally at 1, 2 and 3 mm from the root apex. Each sectioned surface was photographed using a digital camera attached to the stereomicroscope at $12.5{\times}2.5$ fold magnification. All points at 1, 2 and 3 mm were summed as final score of one specimen. Statistical analysis of the collected data was performed. Under the condition of this study. there was no significant difference between the heat source plugging depths of 3, 4, 5, 6 and 7 mm in apical sealing ability. All of apical heat source plugging depth from 3 to 7 mm including Buchanan's protocol -from 5 to 7 mm- seems to be acceptable in clinical application.

Synoptic Air Mass Classification Using Cluster Analysis and Relation to Daily Mortality in Seoul, South Korea (클러스터 분석을 통한 종관기단분류 및 서울에서의 일 사망률과의 관련성 연구)

  • Kim, Jiyoung;Lee, Dae-Geun;Choi, Byoung-Cheol;Park, Il-Soo
    • Atmosphere
    • /
    • v.17 no.1
    • /
    • pp.45-53
    • /
    • 2007
  • In order to investigate the impacts of heat wave on human health, cluster analysis of meteorological elements (e.g., temperature, dewpoint, sea level pressure, visibility, cloud amount, and wind components) for identifying offensive synoptic air masses is employed. Meteorological data at Seoul during the past 30 years are used. The daily death data at Seoul are also employed. Occurrence frequency of heat waves which is defined by daily maximum temperature greater than the threshold temperature (i.e., $31.2^{\circ}C$) was analyzed. The result shows that the frequency and duration of heat waves at Seoul are increasing during the past 30 years. In addition, the increasing trend of the frequency and duration clearly appears in late spring and early autumn as well as summer. Factor analysis shows that 65.1% of the total variance can be explained by 4 components which are linearly independent. Eight clusters (or synoptic air masses) were classified and found to be optimal for representing the summertime air masses at Seoul, Korea. The results exhibit that cluster-mean values of meteorological variables of an offensive air mass (or cluster) are closely correlated with the observed and standardized deaths.

Long and Short Wave Radiation and Correlation Analysis Between Downtown and Suburban Area(II) - Study on Correlation Analysis Method of Radiation Data - (도심부와 교외지역의 장·단파 복사와 상관도 분석 (II) - 관측 자료의 상관도 분석기법에 관한 연구 -)

  • Choi, Dong-Ho;Lee, Bu-Yong;Oh, Ho-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.101-110
    • /
    • 2013
  • The propose of this study is to understand the phenomenon of radiation and comparison of analysis of two methods. One is analysis method of same-time data and the another is analysis method of rank data. We confirmed that two methods of correlation analysis had the effectiveness and suitability. The followings are main results from this study. 1) The seasonal correlation coefficient of long and short-wave radiation is higher in winter than in summer because of high humidity in the summer season can makes easily cloud in the sky locally. 2) According to analysis method, there is big difference in correlation coefficient from 0.494(Analysis method of same-time data) to 0.967(Analysis method of rank data) with short-wave radiation by the location during summer. These results have significant value in solar radiation research and analysis. It has explored a new way for solar radiation research of analysis method as well.