• Title/Summary/Keyword: heat-damage

Search Result 981, Processing Time 0.03 seconds

Formation Behavior of Anodic Oxide Films on Al 6061 Alloy in Sulfuric Acid Solution (황산 용액에서 Al6061 합금의 아노다이징 피막 형성거동)

  • Moon, Sungmo;Jeong, Kihun;Lim, Sugun
    • Journal of Surface Science and Engineering
    • /
    • v.51 no.6
    • /
    • pp.393-399
    • /
    • 2018
  • Formation behavior of aluminum anodic oxide (AAO) films on Al6061 alloy was studied in view of thickness, morphology and defects in the anodic films in 20 vol.% sulfuric acid solution at a constant current density of $40mA/cm^2$, using voltage-time curve, observation of anodized specimen colors and surface and cross-sectional morphologies of anodic films with anodization time. With increasing anodizing time, voltage for film formation increased exponentially after about 12 min and its increasing rate decreased after 25 min, followed by a rapid decrease of the voltage after about 28 min. Surface color of anodized specimen became darker with increasing anodizing time up to about 20 min, while it appeared to be brighter with increasing anodizing time after 20 min. The darkened and brightened surfaces with anodizing time are attributed to an increase in thickness of porous anodic oxide film and a chemical damage of the films due to heat generated by increased resistance of the film, respectively. Cross-sectional observation of AAO films revealed the formation of defects of crack shape at the metal/oxide interface after 15 min which prevents the growth of AAO films. Width and length of the crack-like defect increased with anodizing time up to 25 min of anodizing, and finally the outer part of AAO films was partly dissolved or detached after 30 min of anodizing, resulting in non-uniform surface structures of the AAO films.

An Aspect of Buddhist Medicine in Joseon Dynasty Studied through Sauna Therapy (한증법(汗蒸法)을 통해 바라본 조선조(朝鮮朝) 불교의학(佛敎醫學)의 일면(一面))

  • Lee, U-Jin;Ahn, Sang-Woo;Kim, Dong-Ryul
    • The Journal of Korean Medical History
    • /
    • v.31 no.2
    • /
    • pp.27-40
    • /
    • 2018
  • Sauna, or hanjeung (汗蒸) is a physical sweating method that uses external heat to forcibly raise body temperature to treat cold damage disorders (傷寒) in traditional Korean medicine. This study focuses on the fact that the sauna was recorded as a healing and bathing method on the Vinaya Pitaka (律藏), and investigates the records of folk sauna therapy of Joseon Dynasty from the perspective of Buddhist medicine which played a significant role in ancient medicine history in Korea. Although the word 'hanjeung (汗蒸)' first appeared in "The Veritable Records of King Sejong (世宗實錄)" in the Korean literature, this study aims to confirm the possibility that the tradition of Buddhist sauna bathing has already existed since the Three Kingdoms period in Korea, based on the fact that sauna bathing was recorded in the Vinaya Pitaka and that the ancient Buddhist bathing culture was introduced in ancient Japan. In addition, the succession of the Buddhist sauna tradition by Goryeo will be traced back through the records of 1920s urban saunas in Gaesung (개성) which was the old capital of Goryeo and had a strong tendency to adhere to traditional Goryeo customs. Finally, the study tries to identify the elements of the Buddhist sauna bathing on the records of folk sauna therapy in the Joseon Dynasty. As a result, this study examines how the Buddhist sauna bathing culture in ancient Korea, which was led by medical monks, spread in the general public and influenced the folk sauna therapy in the Joseon Dynasty.

A Study on the Quality Improvment of PCB by Improving Power Consumption for Radar (레이더장비에 적용되는 통신 IC 소비전력 개선을 통한 회로카드조립체 품질 향상에 관한 연구)

  • Jo, Hee-Jin;Gwak, Hye-Rim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.1-6
    • /
    • 2018
  • This study examined the quality improvement of printed circuit boards (PCBs) in relation to the power consumption for radar. The radar examined is currently in production and being used by the military. The PCB converts 28 V DC to 5 V DC but frequently malfunctions. Therefore, cause analysis was carried out. As a result, the power consumed by a certain communication IC was very high, and the heat generated by the high power consumption caused damage to the surrounding parts. Accordingly, it was changed to an improved communication IC that meets all the radar system specifications. System tests were carried out for the changed communication IC to check the impact on the system, and environmental tests were performed, which proved that the performance required by the radar system is satisfactory. As a result of this improvement, there has been no history of failure in this PCB so far. Therefore, the quality of this PCB has been improved.

Virgin Hair and Bleach Hair Thermal analysis study according to temperature change (버진 헤어와 블리치 헤어의 온도 변화에 따른 열분석 연구)

  • Park, Jang-Soon;Lim, Sun-Nye
    • Journal of Industrial Convergence
    • /
    • v.19 no.3
    • /
    • pp.91-96
    • /
    • 2021
  • In order to express the ideal appearance, everyone, regardless of age or gender, invests boldly in appearance management. In particular, hair coloring and hair styling using irons are widely used and used. have. Therefore, for the purpose of presenting the efficient use of flat irons, the study of thermal analysis of virgin hair and bleach hair in 120℃ heat treatment is conducted. As a result of the study, it was found that the overall weight of bleached hair decreased more than that of virgin hair at all treatment temperatures of flat irons. Through this thermal analysis study that measures the weight change according to the temperature rise of virgin and bleached hair, beauty consumers provide information on the optimal temperature flat ironing procedure that can minimize hair damage and discoloration while maintaining color in hair subjected to physical friction. It is believed that it will provide them efficiently.

Analysis on the Light Source Efficiency of CCFL and LED Monitors (CCFL 및 LED 모니터 광원 효율 분석)

  • Shin, Hee-Woo;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.44-50
    • /
    • 2021
  • In this paper, we analyze the efficiency of light sources of CCFL and LED monitors. Cold Cathode Fluorescent Lamp (CCFL), which is widely used as a light source for LCD display, supplies a high voltage of 1,200[V] or more when it is initially driven. In addition, a constant normal voltage of 400 ~ 800[V] after lighting, and 3 ~ 6[ mA] is needed for a power circuit that can stabilize the current. Applying a high voltage causes a lot of stress on the inverter and generates a lot of heat in the cold cathode lamp, causing significant damage to the BLU (Back Light Unit), resulting in a burning phenomenon, which causes the screen to output normal colors when outputting the screen. We can not see the yellow output and the screen darkened. Therefore, in order to prevent such a symptom in advance, efficiency can be increased by using a Light Emitting Diode (LED) as the light source of the LCD display instead of a cold cathode fluorescent lamp (CCFL). As a result, it is shown that the LED method outperforms the CCFL method.

Comparison of EU-DEMO React & Wind Nb3Sn TF CICC current sharing temperature against Wind & React Nb3Sn CICCs

  • Kwon, Soun P.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.2
    • /
    • pp.7-18
    • /
    • 2022
  • European efforts to design superconducting conductors for a future tokamak have involved Nb3Sn cable-in-conduit conductor (CICC). Nb3Sn coils which undergo heat treatment to activate the Nb3Sn material are mostly produced through the wind-then-react route. However, some Nb3Sn coils have been proposed with CICCs of the react-then-wind route. The latter CICCs are physically constrained due to handling limitations which if not adhered to will result in irrecoverable damage to the Nb3Sn cable inside, nullifying any performance advantage. A group at the Swiss Plasma Center has proposed such CICC designs, constructing samples and testing them for performance. The characteristics and performance of these react & wind (R&W) CICCs are compared with the more common wind & react (W&R) CICCs, and it is found that the R&W designs show more extreme characteristics than typical W&R Nb3Sn CICCs for some parameters that are known to influence CICC performance. Where the R&W CICCs extend the range of those parameters, they also continue trends formed by the W&R CICCs with the parameters. The main observation, however, is that although the current sharing temperature performances of the R&W samples are above the average of the W&R samples they were compared to, they are not the highest. A similar observation applies to a cost comparison of the superconducting material where the R&W CICCs are found to be relatively cheap but not the cheapest. Given these results, clear practical advantages to the R&W CICC design is not evident.

Application of 630-nm and 850-nm Light-emitting Diodes and Microcurrent to Accelerate Collagen and Elastin Deposition in Porcine Skin

  • Kwon, Tae-Rin;Moon, Dong Wook;Kim, Jungwook;Kim, Hyoung Jun;Lee, Seong Jae;Han, Yunhee;Dan, Hee Won;Chi, Sang Hoon;Seong, Hwan Mo;Kim, Hee Jung;Lim, Guei-Sam;Lee, Jungkwan
    • Medical Lasers
    • /
    • v.10 no.2
    • /
    • pp.96-105
    • /
    • 2021
  • Background and Objectives Skin aging is reportedly associated with regulation in collagen and elastin synthesis. This study investigated the potential of combining light-emitting diode (LED) treatments using a 630-nm and 850-nm LED with simultaneous microcurrent application. Materials and Methods The dorsal skin of female pigs was treated with a home-use device. We examined the treatment effects using photography, thermocamera, microscopic pathology, and histological examination to determine the mechanism of action, efficacy, and safety of the procedure. A histological observation was performed using hematoxylin and eosin, Masson's trichrome, Victoria blue, and immunohistochemical staining. We also used the Sircol soluble collagen and elastin assay kit to measure the amounts of collagen and elastin in the porcine back skin tissue after 2 and 6 weeks. Results Evaluation by visual inspection and devices showed no skin damage or heat-induced injury at the treatment site. Histological staining revealed that accurate treatment of the targeted dermis layer effectively enhanced collagen and elastin deposition. Collagen type I, a protein defined by immunohistochemical staining, was overexpressed in the early stages of weeks 2 and 6. Combined therapy findings showed the superior capability of the 630-nm and 850-nm LED procedures to induce collagen; in contrast, elastin induction was more pronounced after microcurrent treatments. Conclusion The home-use LED device, comprising a combination of 630-nm and 850-nm LEDs and microcurrent, is safe and can be used as an adjunctive treatment for self-administered facial rejuvenation.

Fundamental Study on the Strength and Heat Transferring Charcteristic of Cement Composite with Waste CNT (폐CNT를 혼입한 시멘트 복합체의 강도 및 열전달 특성에 대한 기초적 연구)

  • Koo, Hounchul;Kim, Woon-Hak;Oh, Hongseob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.66-73
    • /
    • 2022
  • The purpose of this study was to develop self-heating concrete by utilizing the conduction resistance of concrete in order to reduce the risk of occurrence of black ice in the concrete pavement in winter and to prevent damage caused by freez-thawing effect. For this purpose, it was attempted to evaluate the strength and temperature exothermic characteristics using powder and liquid waste CNTs and a waste cathode agent as a conduction promotion. It was analyzed that liquid waste CNT had an effective dispersion degree in the mortar and a small decrease in strength occurred. In addition, DC 24 V was supplied by applying steel mesh, copper foil and copper wire to the mortar as electrodes, and the temperature change characteristics according to the mixing ratio of spent CNTs, anodes and carbon fibers were evaluated. In addition, by evaluating the temperature characteristics according to the electrode spacing from the selected optimal mixture, it was confirmed that it had sufficient heating characteristics up to an electrode spacing of 100 mm up to AC 50 V.

Development of Water Meters for Frozen Inflation Pressure Absorption Based on Structural Analysis (구조해석 기반 동결팽창압 흡수용 수도미터 개발)

  • Kim, Kuk-il;An, Sang-byung;Lee, Byung-sun;Hong, Sung-taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.314-316
    • /
    • 2022
  • Instrumentation device to the amount of water used by the user is a water meter by measuring management stability is necessary. But with the onset of winter to meter water was ice inside the phase change and about 9 % and increase the volume of the meter is damaged. The existing protection bleed water meter freeze protection technology into three great bootong, supplying the heat insulation inside the external protection, water metering for water meter in the freeze protection will be divided into installing the device. Not see how far the structure for the commercialization of new technology-based products and aims to develop technologies that do not require an external power supply. Thus, freeze more vulnerable by internal pressure of the interpretation applied to a water meter in temperatures below zero internal pressure to confirm the area of preventing damage and freeze protection that can reduce the effect is superior to develop a water meter.

  • PDF

Study on Evaluation of Internal Hair Porosity using Optical Microscopy and Improvement of Hair Luster through Internal Hair Density (광학 현미경을 이용한 모발 내부 다공성 평가 및 모발 내부 밀도 증가를 통한 윤기 증가 연구)

  • Hyun-Sub Park;Seong Kil Son;Nae-Gyu Kang;Ik Hyun Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.3
    • /
    • pp.225-230
    • /
    • 2023
  • In this study, the porous structure inside the hair were observed using an optical microscope without damaging the hair, and the porosity inside the hair was quantitatively expressed using the results. Experiments were conducted on the effect of the decrease in density inside the hair on the bending and tensile properties of the hair, and experiments on endogenous and extrinsic factors were conducted to find out the causes of the decrease in density inside the hair. As for the endogenous factor, the porosity of gray hair, one of the representative symptoms of aging, was compared with normal hair. As for extrinsic factors, it was observed that the internal density of hair decreased by surfactant and heat, which are factors that can cause hair damage in daily life. In addition, we confirmed whether it is possible to increase the internal density and luster of the hair by using an amino acids and material that can prevent hair lipid predisposition.