• Title/Summary/Keyword: heat value

Search Result 2,739, Processing Time 0.035 seconds

Development on the Questionnaire of Cold-Heat Pattern Identification Based on Usual Symptoms for Health Promotion - Focused on Agreement Study (건강 증진을 위한 평소 증상 기반의 한열변증 설문지 개발 - 일치도를 중심으로)

  • Bae, Kwang-Ho;Yoon, Youngheum;Yeo, Minkyung;Kim, Ho-Seok;Lee, Youngseop;Lee, Siwoo
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.20 no.2
    • /
    • pp.17-26
    • /
    • 2016
  • Objectives : We presented the results of reliability study in advance, and analyzed agreement between Korean medicine doctors(KMDs)' diagnosis and cold-heat pattern identification questionnaire(CHPI)'s diagnosis. Methods : This survey was conducted from May 16 to 17, 2015. The subjects were 93 adults living in rural society. Diagnosis of CHPI was performed by 2 KMDs who have clinical experience more than 5 years. The KMDs' diagnosis was set as a reference index, and then we compare 23 items(cold pattern 11 items and heat pattern 12 items) of CHPI questionnaire and 15 items(cold pattern 8 items and heat pattern 7 items) that were brief form of it. We had cut-off value by standard of KMDs' diagnosis using receiver operating characteristic-curve(ROC-curve), with which we calculated agreement including kappa value. Correlation analysis between CHPI evaluation score by KMDs and by the questionnaire was fulfilled as well. Results : Agreement about 11 and 8 cold pattern items showed 87.1% together, and the value of kappa each recorded 0.742 and 0.741. Agreement about 12 and 7 heat pattern items suggested 81.7% and 78.5%, and the value of kappa showed 0.634 and 0.570. Correlation coefficients were 0.803 of 11 items and 0.761 of 8 items about cold pattern. In addition, correlation coefficients were 0.789 of 12 items and 0.767 of 7 items about heat pattern. The significant probability (p-value) was under 0.001. Conclusions : We have developed CHPI questionnaire involving reliability and agreement based on usual symptoms, and hope additional complements so that Korean medicine diagnostics and Korean preventive medicine would be improved.

Thermal Analysis According to Material of Manifold (매니폴드 재질에 따른 열 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.3
    • /
    • pp.33-37
    • /
    • 2009
  • Manifold could apply stainless steel with light weight and durability to improve fuel efficiency at automotive industry. This study is analyzed and compared by heat transfer and deformation according to the materials of cast iron and stainless steel. The heat transfer at manifold of cast iron at the distribution of heat temperature is more than that of stainless steel. But the value of maximum heat deformation in case of stainless steel is 1.5 times as great as that in case of cast iron. The value of maximum heat equivalent stress in case of stainless steel is 2.7 times as great as that in case of cast iron. This maximum stress at manifold is shown at the part assembled with engine body.

  • PDF

Heat Budget at Gampo in the Eastern Coast of Korea in 2006 (2006년 동해안 감포의 열수지)

  • Choi, Yong-Kyu;Han, In-Seong;Suh, Young-Sang;Go, Woo-Jin;Kim, Sang-Woo
    • Journal of Environmental Science International
    • /
    • v.18 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) data from National Fisheries Research and Development Institute (NFRDI) in 2006, heat budget was estimated at Gampo in the eastern coast of Korea, the region occuring the cold water known as upwelling in summer. Net heat flux was transported from the air to the sea surface during February to November, and it amounts to $345Wm^{-2}$ in monthly mean value. During December to January, the transfer of net heat flux was conversed from the sea surface to the air with $-56Wm^{-2}$ in minimum of monthly mean value in January. Long wave radiation was ranged from $6Wm^{-2}\;to\;106Wm^{-2}$. Sensible heat was varied from $-36Wm^{-2}$(June) to $61Wm^{-2}$(February) and showed negative values from April to August. Latent heat showed $20Wm^{-2}$(July) with its minimum in July and $49Wm^{-2}$ with its maximum in March in monthly mean value. The annual mean of net heat flux is $129Wm^{-2}$, giving an annual heat surplus of $22Wm^{-2}$. Thus, during summer, the upwelled cold water at Gampo, appears to compensate the heat gain. However the ways in which these compensations are accomplished remains to be clarified.

Value Engineering Approach for Heat Curing Method Under Cold Weather Condition (한중콘크리트 보온양생 공법에 대한 VE분석)

  • Woo, Dae-Hun;Kim, Tae-Cheong;Kim, Jong;Jeon, Chung-Keun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.21-23
    • /
    • 2010
  • This study was conducted to draw various decisive elements of a reasonable heat curing method and to examine the importance in deciding a construction method when constructing cold weather concrete. As a result, the items proposed as important elements at the time of decision of a heat curing method included economy, workability, maintainability, insulation capability, reduced construction period and usability. As a result of importance by items under AHP technique, it was found the most important element was insulation capability, followed by reduced construction period and workability. As a result of comparison of a heat supplying and a heat insulation method by dual bubble sheet differed 2 times as much as a heat supplying method, especially the evaluation degree by insulation capability and reduced construction period was high.

  • PDF

A Study on the Characteristics of Heat Exchanger using Heat Pipe for various Working Condition (운전조건에 따른 히트파이프를 이용한 열교환기의 특성에 관한 연구)

  • Lee, Y.S.;Jang, Y.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.155-165
    • /
    • 1990
  • The purpose of this research is to study the characteristics of heat exchanger using heat pipe under various working conditions by a finite element analysis and experiment. The results are as follows. 1) In this study, h = $Max^B$ is used for the convective heat transfer coefficient and A = 2.761 and B = 0.701 $Mmax^{(-0.0626)}$ were obtained as the results of experiment. 2) For several different working conditions, (Q/Qb) is predicted by varying the values of L/Lt and Re/Rc. The maximum value of (Q/Qb) is achieved when Re/Rc = 1 and Le/Lc = 0.5. 3) The comparison between calculated value and experimental data showed agreement within 5% error. Therefore the method may be used to predict the performance of heat exchanger using heat pipe for similar geometric conditions. 4) For Re/Re/Rc of 0.2-0.3, the minimum thermal resistance exists when Le/Lt is 0.4-0.65.

  • PDF

An Experimental Study on the Energy Efficiency Ratio of Heat Pump for Air Source (공기열원 히트펌프의 에너지 효율 비율에 관한 실험적 연구)

  • SOON YOUNG JEONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.838-844
    • /
    • 2022
  • In this paper, an experimental study was conducted on the energy efficiency ratio of performance for air source heat pump. The energy efficiency ratio presents the operating efficiency of heat pump performance. In order to improve reliability in the energy efficiency ratio test of air source heat pump, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. The measurement uncertainty for the energy efficiency ratio test of air source heat pump was calculated and the measured results were presented.

Improvement of Physical and Drying Properties of Large Diameter and Long Axis Moso Bamboo (Phyllostachys pubescens) Poles Using Heat Treatment

  • Kyoung-Jung KIM;Young-Jin KIM;Se-Yeong PARK
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.447-447
    • /
    • 2023
  • This study aimed to convert underutilized moso bamboo into high-value added products such as fences, interior materials, lighting fixtures, and accessories. Green moso bamboo poles with a diameter of approximately 10 cm and a length of approximately 3.7 m were heat treated at 140℃ using a large-scale kiln. The processing time was meticulously adjusted through various stages, including pretreatment (6-8 hours at 60℃), cooking (8-10 hours at 100℃), steaming (26-30 hours at 120℃), heating (4-6 hours at 140℃), and finally, cooling (below 80℃). A meticulously designed heat treatment process has enabled efficient mass production of moso bamboo poles with improved qualities, including minimal splitting, moisture levels below 3%, and a specific gravity of 1.05. The focus of this study was to present the physical and drying properties, such as color, dimensional change, specific gravity, moisture content, and splitting, observed during the heat treatment process.

A study on the annual energy performance of apartment building with the equivalent U-value of envelope considering the effect of thermal bridges (공동주택 외피의 열교영향을 고려한 상당열관류율 및 연간 에너지소비성능 평가 연구)

  • Kim, Dong Su;Yoon, Jong Ho;Shin, U Cheul;Kwak, Hee Yul
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.41-46
    • /
    • 2012
  • The building envelope is important specially for saving energy consumption of residential buildings. but Apartment houses in Korea commonly have inside insulation system which have constantly arisen thermal bridges, the risk of heat loss, as a necessity. This study aims to evaluate integrated insulation performance according to the different shapes of external walls, adjacent to windows. The thermal performance analysis was carried out by Equivalent U-value and using the three-dimensional heat transfer computer simulation (TRISCO-RADCON), under nine different cases of comparing among three each of different bases(current standard model, 30percent energy saving model and 60percent energy saving model). The heating and the cooling load were also compared between two cases (standard U-value and Equivalent U-value) of three each of different bases, using the Building energy simulation which is based on DOE-2.1 analysis. As results, it turns out that if the Equivalent U-value is considered on the envelope analysis, the heat flow loss will be increasing more than the standard U-value, and if heat insulation property of the residential building reinforced rather than current, the rate of influences on the thermal bridges would be extremely expanded. In addition, it is shown that annual heating loads of the apartment house with applied Equivalent U-value substantially increased by more than 15 percent compared to those with the existing U-value, but annual cooling loads were negligibly affected.

Study on Hydration Heat and Contact the Mix-Design of Foundation Mass Concrete Using Hydration Temperature Analysis Program (수화열 해석프로그램을 이용한 기초 매스콘크리트의 사전 배합선정 및 수화열 검토)

  • Seol, Jun-Hwan;Jo, Man-Ki;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.105-106
    • /
    • 2019
  • In this research, considering the practical conditions at field, thermal cracking method was suggested based on the comparative analysis between predicted value and actual value obtained from the actual structure member with optimum mix design. The optimum mix design was deduced from the various mix designs with various proportions of cementitious binder for upper and lower placement lifts of mat-foundation mass concrete. Therefore, it can be stated that applying low heat mix design and different heating technique between upper and lower placement lifts for mass concrete are efficient to control the thermal cracking. As future issues, based on the interpretation result value, we will select the optimal combination that is applied specifically to the actual site, and deeply analyze the correlation between the measured value and the analysis value through the combination and the test of the actual structure.

  • PDF

Evaporating Heat Transfer Characteristics of R-290, R-600a Inside Horizontal Double Pipe Heat Exchangers (R-290, R-600a의 수평 이중관형 열교환기내 증발 특성)

  • 홍진우;노건상;권옥배;박기원;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.309-314
    • /
    • 2000
  • Experimental results for heat transfer characteristics of natural refrigerants R-290, R-600a and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers are presented. The experimental apparatus is basically a vapour heat pump system, composed of a compressor, a condenser, expansion devices, a evaporator, and some other peripheral devices. The test sections were horizontal double pipe heat exchangers, which were a pair of smoothed tube, having 10.07 mm ID, 12.07 mm OD, and grooved inner fin tube, having 12.70 mm OD, 0.25 mm fin height, and 75 fins. The local evaporating heat transfer coefficients of natural refrigerants were not much affected with the mass velocity than R-22 and it could be interpreted that the local evaporating heat transfer coefficients of R-22 were increased more than those of R-290, R-600a according to the increment of mass velocity. Moreover, the maximum increment of the heat transfer coefficient was found in R-290. The average heat transfer coefficient was obtained the maximum value in R-290 and the minimum value in R-22. It reveals that the natural refrigerant can be used as a substitute for R-22. In the grooved inner fin tube, 70% of the increment of the heat transfer coefficient was obtained compared to the smoothed tube.

  • PDF