• Title/Summary/Keyword: heat conservation

검색결과 373건 처리시간 0.022초

액적 충돌에 동반된 열전달에 관한 수치적 연구 (Numerical Study of Heat Transfer Associated with Droplet Impact)

  • 김성일;손기헌
    • 대한기계학회논문집B
    • /
    • 제28권9호
    • /
    • pp.1093-1100
    • /
    • 2004
  • Numerical analysis of the heat transfer associated with droplet impact on a hot solid surface is performed by solving the equations governing conservation of mass, momentum and energy in the liquid and gas phases. The deformed droplet shape is tracked by a level set method which is modified to achieve volume conservation and to include the effect of contact angle at the wall. The numerical method is validated through the calculations for the cases reported in the literature. Based on the numerical results, the heat transfer rate is found to depend strongly on the droplet spread radius. Decreased advancing/receding contact angles enlarge the splat radius and in turn enhance the wall heat flux. The effect of impact velocity on the droplet spread is reduced as the droplet size decreases. Also, droplet atomization is observed to significantly enhance the heat transfer rate and the effect is pronounced for a smaller size of droplet. An existing model equation to predict the maximum spread radius is improved for application to a micro droplet.

피복효과면에서 본 발과 다리의 체온조절적 특성 (Thermoregulatory Characteristics of Feet and Legs in aspects of Covering Effect)

  • 이종민
    • 한국의류학회지
    • /
    • 제23권7호
    • /
    • pp.965-970
    • /
    • 1999
  • This study was conducted to investigate the thermoregulatory characteristics of feet and legs by comparing with the physiological responses according to the covering parts of lower limbs. Five healthy female subjects wore three types of clothing-covered legs and feet(LF-C) with long trousers and socks exposed the legs(L-E) with half trousers and socks and exposed the legs and feet(LF-E) with only half trousers-when the subjects rested at $25^{\circ}C$ and were exposed to 18$^{\circ}C$ for 90 min. Rectal temperatures (Tre) were maintained higher in LF-E than L-E and LF-C at both environments. Decreases of The after exposure to 18$^{\circ}C$ were significantly smaller in LF-E than L-E and LF-C and almost same in L-E and LF-C Heat production in both environments increases of heat production and weight loss after exposure to 18$^{\circ}C$ were not significant among three types of clothing. From these findings it would be suggested that the legs would play the little role of voluntary thermoregulation as vasoconstriction and the role of the legs depend on thermal conditions of feet while the feet play the positive role of voluntary thermoregulation in terms of heat conservation in cool environment.

  • PDF

공동주택 열교환기의 성능 및 에너지소비 특성 평가 (Evaluation of the Performance and the Energy Consumption Characteristics of Heat Recovery Ventilators in Apartments)

  • 김상민;박병윤;손장열
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.496-504
    • /
    • 2005
  • Heat recovery ventilators (HRV) are developed in order to satisfy both energy conservation and the improvement of indoor air quality as an alternative for current natural ventilation systems and local mechanical ventilation systems in kitchens and bathrooms. However, the performance of HRV system and the consequent effect on heating and cooling energy saving have not been sufficiently validated quantitatively in case of the application of HRVs in real residences. In this study, field measurement and computer simulation were conducted in both summer and winter period to assess the performance and validate energy conservation effect of HRVs. Under the Korea weather condition, average total heat recovery efficiency was $27\%$ in summer and $46\%$ in winter. According to the field measurement, HRV system can save the energy by $10\%$ in summer and 15$\%$ in winter. Furthermore, according to the simulation assessment, HRV system can save the energy by $17\%$ in summer and $17\%$ in winter.

국내 산업폐열 현황에 대한 조사연구 (An Investigation Study on Fact of Waste Heat of Domestic Industry)

  • 박일환;박준태;유성연
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.811-816
    • /
    • 2002
  • Waste heat exhausted from seven types of the domestic industry was surveyed, which include food, fibre, paper & wood, chemical, ceramics, metalworking and others. The databases of waste heat for each industry were made by using ACCESS software of Microsoft, and data were analyzed to get correlation between waste heat and purchase energy. The volume of usable waste heat is estimated to be 9,169,000 TOE in the year of 2000, when the minimum available temperature is set as $100^{\circ}C$ for waste gas, $30^{\circ}C$ for hot water and $100^{\circ}C$ for steam considering the condition of waste heat exhausting facilities and surroundings. This volume of waste heat is approximately 11.9 percent of the purchase energy of the domestic industry.

VM 열펌프의 3차해석 (A Third-order analysis of VM heat pumps)

  • 강영구;정은수
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.229-238
    • /
    • 1997
  • A third-order simulation model of VM heat pumps has been developed. This model allows consideration of the major losses such as heat conduction losses through regenerators and displacers, pumping losses and wall-to-gas heat transfer losses in working volumes, in addition to the heat exchanger and regenerator losses. The working volume was divided into 12 control volumes and conservation equations of mass and energy were applied to each control volume. Pressure drop was considered in regenerators only. Thermodynamic behavior of working fluid in a VM heat pump was investigated and effects of major losses on the performance of a VM heat pump were shown.

  • PDF

과도열전도를 갖는 평판핀에서의 강제대류 열전달 (Forced Convection Heat Transfer in a Plate Fin With Transient Heat Conduction)

  • 조진호;이상균
    • 오토저널
    • /
    • 제9권4호
    • /
    • pp.69-76
    • /
    • 1987
  • A conjugate conduction-convection analysis has been made for a plate fin which exchanges heat with its fluid environment by forced convection. The analysis is based on a one- dimensional model for the plate fin whereby the transient heat conduction equation for the fin is solved simultaneously with the conservation equations for mass, momentum, and energy in the fluid boundary layer adjacent to the fin. The forced convection heat transfer coefficient is not specified in advance but is one the results of the numerical solutions. Numerical results of the overall heat transfer rate, the local heat transfer coefficient, the local heat flux, the fin efficiency and the fin surface temperature distribution for Pr=0.7 are presented for a wide range of operating conditions.

  • PDF

A Third-order Simulation Model of a Vuilleumier Cycle Heat Pump

  • Kang, Young-Goo;Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.80-92
    • /
    • 1998
  • A third-order simulation model of a Vuilleumier{VM) heat pump has been developed. This model takes into account the major losses such as the heat conduction losses through regenerators and displacers, the pumping losses and the wall-to-gas heat transfer losses in active volumes, in addition to the heat exchanger and regenerator losses. The working volume was divided into 12 control volumes and the conservation equations of mass and energy were applied to each control volume. Pressure drops were considered in regenerators only. Thermodynamic behavior of the working gas in a VM heat pump was investigated and effects of the major losses and operating conditions on the performance of a VM heat pump were shown.

  • PDF

실내수영장의 에너지 소비요소별 에너지 절약효과에 관한 연구 (A Study on the Energy Conservation Effect of Each Energy Consumption Component In Indoor Swimming Pools)

  • 김영돈;권규동;여명석;김광우
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1092-1101
    • /
    • 2002
  • The objective of this study is to develop energy saving strategies for indoor swimming pools and to estimate the effect of each energy saving strategy. For this purpose, field measurements regarding pool water heating energy, domestic hot water heating energy are conducted and a base energy consumption model is implemented using the DOE-2.1E program. The results of the study reveal that 25% of the total pool water heating energy may be saved by using night time pool covers, 27% of the total domestic hot water heating energy may be saved by using a waste water heat recovery system (effic. 60%), and of the total ventilation energy may be saved using an exhaust air heat recovery system (effic. 60%).

쌍롤 연속 주조에서의 난류 유동, 온도 및 응고 예측을 위한 연구 (A Numerical Study of Turbulent Flow, Heat Transfer, and Solidification in Twin-Roil Continuous Casting)

  • 하만영;최봉석
    • 대한기계학회논문집B
    • /
    • 제23권1호
    • /
    • pp.12-24
    • /
    • 1999
  • A computer program has been developed for analyzing the two-dimensional, unsteady conservation equations for transport phenomena in the molten region of twin-roll continuous casting in order to predict the turbulent velocity, temperature fields, and solidification process of the molten steel. The energy equation of the cooling roll is solved simultaneously with the conservation equations of molten steel in order to consider heat transfer through the cooling roll. The results show the velocity, temperature and solidification pattern in the molten region with roll temperature as a function of time. The results for velocity and temperature fields with solidification are compared with those without solidification, giving different thermofluid characteristics in the molten region. We also investigated the effects of revolutional speed of roll, superheat and nozzle geometry on the turbulent flow, temperature and solidification in the molten steel and temperature fields in the cooling roll.

The Proposal of a Quantitative Evaluation Method on Mixing Loss in the HVAC System Design

  • Yee, Jurng-Jae;Kim, Young-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.62-68
    • /
    • 2001
  • It is a serous subject for energy conservation to prevent the energy loss caused by the mixture of heated and cooled air jets in perimeter and interior zone of a building operated with tow kinds of air-conditioning system simultaneously. The purpose of this paper is to clarify the quantitative and qualitative mechanisms of mixing loss and to propose a evaluation method for it. By using the dynamic heat load calculation, heat extraction load of a typical office building in Busan are calculated. According to the results, numerical simulations based on CFD(Computational Fluid Dynamics) were performed in order to evaluate mixing loss in the physical size of HVAC system. Then, the distributions of air temperature and airflow patterns according to the differences of set-point temperature are analyzed to grasp relations how to influence mixing loss.

  • PDF