셀룰로오스 나노크리스탈과 산화그래핀이 시멘트 페이스트의 수화열에 미치는 영향 (Effects of cellulose nanocrystals and graphene oxide on hydration heat of cement paste )

  • 이윤경;김지현;정철우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.189-190
    • /
    • 2023
  • In this study, the compressive strength and hydration heat of cement paste mixed with cellulose nanocrystal(CNC) and graphene oxide (GO) were evaluated. The difference was compared by mixing 0.1 vol.% ~0.4 vol.% of CNC and 0.05 wt.% ~ 0.1 wt.% of GO in a cement paste with a water cement ratio of 0.3. As a result, it was confirmed that the compressive strength increased as CNC and GO were mixed respectively, and then the compressive strength decreased when the appropriate mixing rate was exceeded. In the hydration heat measurement, there was no significant difference when only CNC was mixed, but it was confirmed that the hydration heat decreased as the amount of CNC mixing increased when used in combination with GO.

  • PDF

극저온 조건에서 보온양생 방법 변화에 따른 콘크리트의 초기동해 방지 (Prevention of Early Frost Damage of the Concrete under Severely Low Temperature according to Heat Curingmethods)

  • 한민철
    • 한국건축시공학회지
    • /
    • 제16권1호
    • /
    • pp.67-76
    • /
    • 2016
  • $-20^{\circ}C$이하의 극저온조건에서 타설되는 콘크리트는 초기동해 방지를 위해 적절한 급열을 포함한 보온양생이 이루어져야 하는데, 현재까지 국내에서 극저온조건의 효율적인 보온양생 방법이 제시된 경우가 드문 실정이다. 따라서 본 연구에서는 $-20^{\circ}C$의 극한조건에서 시공되는 콘크리트의 초기동해 방지를 위한 효율적인 보온양생방법을 제시하고자, 보온양생 재료의 조합 변화에 따른 콘크리트의 온도이력, 적산온도 및 코어강도 결과를 고찰하였다. 실험변수로서 보온양생방법 조합에 따라 기둥, 슬래브 및 벽체를 모사한 목업 시험체를 제작한 후, 단열, 가열 및 양자 병용방법을 적용하여 실험을 진행하였다. 연구결과에 따르면, 슬래브 부재의 경우 온도이력 및 적산온도 측정결과 4BS+열선조합, 벽체의 경우 가열양생+발열매트 그리고 기둥의 경우 EPS 단열재조합에서 3일 이내에 초기동해 방지에 요구되는 적산온도인 $45^{\circ}D{\cdot}D$를 상회하며 $0^{\circ}C$이하로 콘크리트 온도가 저하하지 않는 것으로 나타나 본 연구범위에서 최적의 조합으로 판단된다.

도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석 (Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate)

  • 여인애;이정재;윤성환
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

The Homologous Region 3 from Bombyx mori Nucleopolyhedrovirus Enhancing the Transcriptional Activity of Drosophila hsp70 Promoter

  • Tang, Shun-Ming;Yi, Yong-Zhu;Zhou, Ya-Jing;Zhang, Zhi-Fang;Li, Yi-Ren;He, Jia-Lu
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제9권2호
    • /
    • pp.235-239
    • /
    • 2004
  • Drosophila melanogaster heat shock protein 70 gene promoter (Dhsp70p) is widely used in transgenic insect to drive exogenous gene, and the homologous region 3 from Bombyx mori nucleopolyhedrovirus (BmNPVhr3) functions as an enhancer for several promoters. To test whether BmNPVhr3 can enhance the Dhsp70ps transcriptional activity, the reporter plasmids, which contain the Dhsp70p, the reporter $\beta$-galactosidase gene with SV40 terminator and BmNPVhr3 fragment, are constructed and transfected into the insect cell lines (Bm-N cells and Sf-21 cells) by lipofectin-mediated method. The results from the transient expression assay show that BmNPVhr3 significantly increases transcriptional activity of Dhsp70p both under the normal condition and under the heat-shock treatment, although the effects are significantly different between in Bm-N cells and in sf-21 cells. The enhancing behavior of BmNPVhr3 on the Dhsp70p is in an orientation-independent manner. Meanwhile, the effects of heat-shock treatment on Dhsp70p alone or Dhsp70p/BmNPVhr3 combination present no significant difference, indicating that BmNPVhr3 only enhances the transcriptional activity of Dhsp70p, but cant alter its characteristic of the response to the heat-shock stress. The above results suggest that the Dhsp70p/BmNPVhr3 combination is more effective one to drive exogenous gene for transgene or stable cell expression system in insects.

유동형 미세 열유속 센서의 설계 (Design of The Micro Fluidic Heat Flux Sensor)

  • 김정균;조성천;이선규
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.138-145
    • /
    • 2009
  • A suspended membrane micro fluidic heat flux sensor that is able to measure the heat flow rate was designed and fabricated by a complementary-metal-oxide-semiconductor-compatible process. The combination of a thirty-junction gold and nickel thermoelectric sensor with an ultralow noise preamplifier, low pass filter, and lock-in amp has enabled the resolution of 50 nW power and provides the sensitivity of $11.4\;mV/{\mu}W$. The heater modulation method was used to eliminate low frequency noises from sensor output. It is measured with various heat flux fluid of DI-water to test as micro fluidic application. In order to estimate the heat generation of samples from the output measurement of a micro fluidic heat-flux sensor, a methodology for modeling and simulating electro-thermal behavior in the micro fluidic heat-flux sensor with integrated electronic circuit is presented and validated. The electro-thermal model was constructed by using system dynamics, particularly the bond graph. The electro-thermal system model in which the thermal and the electrical domain are coupled expresses the heat generation of samples converts thermal input to electrical output. The proposed electro-thermal system model shows good agreement with measured output voltage response in transient state and steady-state.

내부에 히트파이프를 삽입한 메탈 하이드라이드 반응기의 열전달 특성에 대한 수치해석 연구 (A Numerical Study on the Heat Transfer Characteristics of a Metal Hydride Reactor with Embedded Heat Pipes)

  • 박영학;부준홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2346-2351
    • /
    • 2008
  • This study deals with heat pipes inserted into the metal hydride(MH) reactor to increase the effective thermal conductivity of the system and thus to enhance the thermal control characteristics. A numerical analysis was conducted to predict the effect of inserted heat pipes on the heat transfer characteristics of MH, which inherently has extremely low thermal conductivity. The numerical model was a cylindrical container of O.D. 76.3 mm and length 1 m, which is partially filled with about 60% of MH material. The heat pipe was made of copper-water combination, which is suitable for operation temperature range between $10^{\circ}C$ and $80^{\circ}C$. Both inner -and outer- heat pipes were considered in the model. Less than two hours of transient time is of concern when decreasing or increasing the temperature for absorption and discharge of hydrogen gas. FLUENT, a commercial software, was employed to predict the transient as well as steady-state temperature distribution of the MH reactor system. The numerical results were compared and analyzed from the view point of temperature uniformity and transient time up to the specified maximum or minimum temperatures.

  • PDF

타이타늄 중공마더빌렛 주조재의 열처리공정 최적화 연구 (Study for Heat Treatment Optimization of Titanium Hollow Casted Billet)

  • 윤창석;박양균;이형욱;이동근
    • 열처리공학회지
    • /
    • 제32권2호
    • /
    • pp.68-73
    • /
    • 2019
  • ${\alpha}$-titanium alloy has a relatively low heat treatment characteristic and it is mainly subjected to heat treatment for residual stress, recovery or dynamic recrystallization. In this study, commercially pure titanium hollow castings was fabricated by gravity casting. Heat treatments were carried out at $750^{\circ}C$, $850^{\circ}C$ and $950^{\circ}C$ to investigate the effect of post-heat treatment on microstructure and mechanical properties. Beta-transus temperature ($T_{\beta}$) was about $913^{\circ}C$, and equiaxed microstructure was shown at temperature below $T_{\beta}$ and lath-type microstructure at temperature above $T_{\beta}$. Microstructure and mechanical properties did not show any significant difference in the direction of solidification for titanium hollow billet, so it can be seen that it was a well-made material for extrusion process. The optimum heat treatment condition of hollow billet castings for the seamless tube production was $850^{\circ}C$, 4 hr, FC, indicating a combination of equiaxed microstructure and appropriate mechanical properties.

습열병의 형상의학적 고찰 및 치료 -동의보감을 중심으로- (Review and Treatment of Damp Heat disease in Hyungsang Medicine)

  • 강영화;조장수;김경철;이용태
    • 동의생리병리학회지
    • /
    • 제16권4호
    • /
    • pp.649-656
    • /
    • 2002
  • Damp Heat is a combination of Damp and Heat if conditioned internally and externally, and constitutes vital Ki as well as pathogenic Ki. Damp Heat, as vital Ki, is one of the essential factors in forming the body and preserving life activity, and on the other hand, as pathogenic Ki, it causes undear mentality, gastric discomfort with acid regurgitation, San disease(疝病), cardiac beriberi, flaccidity symtoms, muscular atonia or contracture and dark or cloudy urine. In Hyungsang Medicine, the Dam type develops Damp Heat disease mostly due to Heat, and the treatment is to promote urination by clearing Heat; on the other hand, in the Bangwang type, Damp is the major cause and the treatment is to induce sweating and eliminate Damp.

연소 또는 소각 과정에서 발생하는 배기가스의 폐열 회수 설계 방법에 관한 연구 (Study on the Heat Recovery Design Methods for the Flue Gas from Combustion and Incineration Processes)

  • 이찬;정봉진
    • 청정기술
    • /
    • 제5권2호
    • /
    • pp.53-61
    • /
    • 1999
  • 대형 산업용 환경폐기물 처리 및 열병합 플랜트의 연소 및 소각 공정 후 발생하는 배기가스의 폐열회수장치 설계 방법을 제시하였다. 본 연구는 폐열회수장치의 기본 설계 개념을 폐열회수를 위한 보일러와 폐열을 이용한 증기 동력 사이클로 구성되는 것으로 가정하였고, 폐열회수장치에 필요한 각 구성요소들에 대한 모델링 기법과 그에 따른 설계 기준 및 설계 개념을 기술하였다. 또한 본 설계방법을 이용하여, 동일한 배기가스 조건에 대해, 폐열회수 보일러의 작동 압력 및 폐열회수 열교환기 설계에 따라 폐열회수장치의 열성능이 어떻게 변화되는지를 검토하였다.

  • PDF

복합보온양생 방법이 극저온 조건하 플라이애시 치환 콘크리트의 온도이력에 미치는 영향 (The Effect of Heat Curing Methods on the Temperature History of the Fly Ash Concrete Subjected to Extremely Low Temperature)

  • 한민철;손호정
    • 한국건설순환자원학회논문집
    • /
    • 제7권3호
    • /
    • pp.85-90
    • /
    • 2012
  • In this study, temperature profile of the fly ash concrete were studied in accordance with the change of heating curing method combination for the slab concrete in order to develop efficient protection method of the concrete subjected to $-20^{\circ}C$. The slab concretes with the size of $1200mm{\times}600mm{\times}200mm$ were fabricated with W/B of 50% and exposed to $-20^{\circ}C$ for 7 days. Five different combinations of heat curing methods were applied to the slab concrete specimen; two combinations of heat supplying by electrical heater and surface heat insulation material such as polyethylene film and quadrupled layer bubble sheet based on heat enclosure installment; three combinations of heating coil embedment and surface heat insulation materials such as polyethylene film, sawdust and quadrupled layer bubble sheet based on heat enclosure installment. Test results showed that by applying both heating coil and bubble sheet and heat enclosure, the concrete exposed to $-20^{\circ}C$ can be effectively protected from early-age frost damage.

  • PDF