In this study, the linear cutting tests of pick cutters were carried out on a granitic rock with the average compressive strength over 100 MPa. From the tests, the correlation between the cutter acting force and the temperature measured by infrared thermal imaging camera during rock cutting was analyzed. In every experimental condition, the maximum temperature was measured at the rock surface where the chipping occurred, and the temperature generated in the rock was closely correlated with the cutter acting force. On the other hand, the temperature of a pick cutter increased up to only 36℃ above the ambient temperature, and the correlation with the cutter force was not obvious. This can be attributed to the short cutting distance under laboratory conditions and the high thermal conductivity of the tungsten carbide inserts. However, the relatively high temperature of the tungsten carbide inserts was found to be maintained. Therefore, it is recommended that a reinforcement between the insert and the head of a pick cutter or the quality improvement of silvering brazing in the production of a cutter is necessary to maintain the high cutting performance of a pick cutter.
This experiment was carried out to investigate the effects of dietary vitamin E levels on carcass characteristics and vitamin E contents, fatty acid composition and lipid oxidation as indicated by thiobarbituric acid reactive substances(TBARS) of the longissimus muscle in Hanwoo steers. Forty Hanwoo steers were randomly assigned to one of four groups and fed the diet containing 200(control), 1000, 2000 or 2500 IU a(alpha)-tocopherol acetate/head/day for 3 months of last finishing period. Backfat thickness was thinner and beef fat color was whiter(P<0.05) in steers fed the vitamin E supplemented diets than those fed the control diet. But the longissimus muscle area and yield grade did not differ among treatments. Marbling score and quality grade were higher(P<0.05) in steers fed the diets containing 1000 and 2000 IU vitamin E than those fed the other diets. Vitamin E concentration in the longissimus muscle was higher(P<0.05) as the vitamin E content in diet was higher. The levels of oleic and linoleic acids in the longissimus muscle were not affected by dietary vitamin E levels. But linolenic and arachidonic acids were lower in steers fed the vitamin E supplemented diets than those fed the control diet. TBARS in the longissimus muscle was not affected by the vitamin E levels in diet until 5th day of storage but delayed muscle lipid oxidation in steers fed the vitamin E supplemented diets after 7th day of storage. Therefore according to this result, it may be concluded that steers have a higher quality grade and higher vitamin E concentration in muscle and lower in TBARS when diet contains 1000 or 2000 IU vitamin E per kg of diet.
Moon, hyeon seok;Jeong, deok yang;Do, gyeong min;Lee, yeong cheol;Kim, sun myung;Kim, young bum
The Journal of Korean Society for Radiation Therapy
/
v.28
no.2
/
pp.101-108
/
2016
Purpose : The purpose of this study was to evaluate the Retro recon in SRS planning using BranLAB when stereotactic location error occurs by metal artifact. Materials and Methods : By CT simulator, image were acquired from head phantom(CIRS, PTW, USA). To observe stereotactic location recognizing and beam hardening, CT image were approved by SRS planning system(BrainLAB, Feldkirchen, Germany). In addition, we compared acquisition image(1.25mm slice thickness) and Retro recon image(using for 2.5 mm, 5mm slice thickness). To evaluate these three images quality, the test were performed by AAPM phantom study. In patient, it was verified stereotactic location error. Results : All the location recognizing error did not occur in scanned image of phantom. AAPM phantom scan images all showed the same trend. Contrast resolution and Spatial resolution are under 6.4 mm, 1.0 mm. In case of noise and uniformity, under 11, 5 of HU were measured. In patient, the stereotactic location error was not occurred at reconstructive image. Conclusion : For BrainLAB planning, using Retro recon were corrected stereotactic error at beam hardening. Retro recon may be the preferred modality for radiation treatment planning and approving image quality.
Shin Kyung Hwan;Park Sung-Yong;Park Dong Hyun;Shin Dongho;Park Dahl;Kim Tae Hyun;Pyo Hongryull;Kim Joo-Young;Kim Dae Yong;Cho Kwan Ho;Huh Sun Nyung;Kim Il Han;Park Charn Il
Radiation Oncology Journal
/
v.23
no.3
/
pp.176-185
/
2005
Purpose: Film dosimetry as a part of patient specific intensity modulated radiation therapy quality assurance (IMRT QA) was peformed to develop a new optimization method of film isocenter offset and to then suggest new quantitative criteria for film dosimetry. Materials and Methods: Film dosimetry was peformed on 14 IMRT patients with head and neck cancers. An optimization method for obtaining the local minimum was developed to adjust for the error in the film isocenter offset, which is the largest part of the systemic errors. Results: The adjust value of the film isocenter offset under optimization was 1 mm in 12 patients, while only two patients showed 2 mm translation. The means of absolute average dose difference before and after optimization were 2.36 and $1.56\%$, respectively, and the mean ratios over a $5\%$ tolerance were 9.67 and $2.88\%$. After optimization, the differences in the dose decreased dramatically. A low dose range cutoff (L-Cutoff) has been suggested for clinical application. New quantitative criteria of a ratio of over a $5\%$, but less than $10\%$ tolerance, and for an absolute average dose difference less than $3\%$ have been suggested for the verification of film dosimetry. Conclusion: The new optimization method was effective in adjusting for the film dosimetry error, and the newly quantitative criteria suggested in this research are believed to be sufficiently accurate and clinically useful.
Journal of Korean Academy of Nursing Administration
/
v.3
no.1
/
pp.119-133
/
1997
Continuing shift service of clinical nurses can be not only the cause of occupational dissatisfaction by being connected with the change of circadian rhythm and the burden of duties to be applicable to such changes. But also of inviting the lowering of nursing quality by being affected to the resignation of the nurses as the threat to the health of the nurses. This study has selected 500 nurses at random under non-probability sampling who have been serving by shift in 7 general hospitals which have over 400 sickbeds for the purpose of cross-sectional survey design from Sep. 7 through 20, 1996. Standardized modification of the CMI has been used which was designed for Koreans with Cornell Medical Index developed by Broadman and his fellow workers as the study device. The structure of the device was composed of 35 questions on physical appeal(Chronbach's ${\alpha}=8507$) and 22 questions of mental appeal(Cronbach's ${\alpha}=.8166$ totalling 57 questions. The collected data has been computerrized by using SPSS. General character, present symptom, perceived symptom and others are sought by practical number and percentage, and the health condition comparison followed by general characters was conducted by t-test and ANOVA. The post test was by Duncan's test by the level of p<.05. 1) The items of the answer that they have the physical symptom presently by 50% or over of the nurses were as "Do you often have spells of severe dizziness", "Are your eyes often red or inflamed", "Does press or pain in the head often make like miserable", "Are your ankles often badly swollen", "Do pains in the back make it hard for you to keep up with your work". 2) The items of the answer by over 50% of the nurses as the mental symptom at present were "do you fell bad when criticized?", "Do you get angry when everything is against your will?", "do you get angry when ordered to do this and that?", "do you feel uneasy by such a trifle thing?", "do you tremble or are you freightened by sudden sound?". The mental and physical symptoms which have appeared presently in connection with the shift service have been agreed with each other. But the physical condition has been worse than the mental one. 3) In the physical health conditions followed by demosociological character, there were the significant differences by sex, religion and place of residence(p<.05), and in the mental health conditions, there were the significant differences by age, marital status, residence place and the required time for attending hospital(p<.05). 4) There was significant difference by the degree of satisfaction about the duty in both the physical and mental health conditions. In short, the higher the degree of duty satisfaction, the better the health conditions. 5) There were the significant difference according to the times of night duty and whether they take the drug or not or the kinds of the drugs in the physical health conditions related with the characters of night shift. Mental health conditions in the night shift case showed significant differences according to their taking drug or not or the kinds of the drugs(p<.05). I can confirm that the nurses have been affected continuously by the shift service mentally and physically. The maintenance of the physical and mental health of the nurses and its promotion are very important problem to guarantee the quality nursing in the performance of the nursing service continuously and effectively, so the hospital should make every effort to improve the duty conditions by finding out the causes affecting to their health. In the nursing management viewpoint, I think that elevating the satisfaction degree about the duty would be a great help to the promotion of physical and mental health conditions. But what is most important is that the nurses themselves should take care of themselves in maintaining the good conditions in their service in the hospital.
Kim, Tae-Ho;Oh, Seung-Jong;Kim, Min-Joo;Jung, Won-Gyun;Chung, Jin-Beom;Kim, Jae-Sung;Kim, Si-Yong;Suh, Tae-Suk
Progress in Medical Physics
/
v.22
no.2
/
pp.61-66
/
2011
In this study, we evaluated the effect of grid size on dose calculation accuracy using 2 head & neck and 2 prostate IMRT cases and based on this study's findings, we also evaluated the efficiency of a 2D diode array detector for IMRT quality assurance. Dose distributions of four IMRT plan data were calculated at four calculation grid sizes (1.25, 2.5, 5, and 10 mm) and the calculated dose distributions were compared with measured dose distributions using 2D diode array detector. Although there was no obvious difference in pass rate of gamma analysis with 3 mm/3% acceptance criteria for the others except 10 mm grid size, we found that the pass rates of 2.5, 5 and 10 mm grid size were decreased 5%, 20% and 31.53% respectively according to the application of the fine acceptance criteria, 3 mm/3%, 2 mm/2% and 1 mm/1%. The calculation time were about 11.5 min, 4.77 min, 2.95 min, and 11.5 min at 1.25, 2.5, 5, and 10 mm, respectively and as the grid size increased to double, the calculation time decreased about one-half. The grid size effect was observed more clearly in the high gradient area than the low gradient area. In conclusion, 2.5 mm grid size is considered acceptable for most IMRT plans but at least in the high gradient area, 1.25 mm grid size is required to accurately predict the dose distribution. These results are exactly same as the precious studies' results and theory. So we confirmed that 2D array diode detector was suitable for the IMRT QA.
Son Hye-Kyung;Lee Sang-Hoon;Nam So-Ra;Kim Hee-Joung
Progress in Medical Physics
/
v.17
no.2
/
pp.89-95
/
2006
The purpose of this study was to evaluate the radiation doses during CT transmission scan by changing tube voltage and tube current, and to estimate the radiation dose during our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan. Radiation doses were evaluated for Philips GEMINI 16 slices PET/CT system. Radiation dose was measured with standard CTDI head and body phantoms in a variety of CT tube voltage and tube current. A pencil ionization chamber with an active length of 100 mm and electrometer were used for radiation dose measurement. The measurement is carried out at the free-in-air, at the center, and at the periphery. The averaged absorbed dose was calculated by the weighted CTDI ($CTDI_w=1/3CTDI_{100,c}+2/3CTDI_{100,p}$) and then equivalent dose were calculated with $CTDI_w$. Specific organ dose was measured with our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan using Alderson phantom and TLDs. The TLDs used for measurements were selected for an accuracy of ${\pm}5%$ and calibrated in 10 MeV X-ray radiation field. The organ or tissue was selected by the recommendations of ICRP 60. The radiation dose during CT scan is affected by the tube voltage and the tube current. The effective dose for $^{137}Cs$ transmission scan and high qualify CT scan are 0.14 mSv and 29.49 mSv, respectively. Radiation dose during transmission scan in the PET/CT system can measure using CTDI phantom with ionization chamber and anthropomorphic phantom with TLDs. further study need to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with same image qualify.
Present study was conducted to investigate the optimal feeding levels for producing the high quality meat on the basis of the information deriving from the comparison of the growth performance and carcass characteristics among breeds(Holstein vs F1, Holstein♀×Hanwoo♂), sex(steer vs heifer) and interaction between breed and sex. Thirty two animals on 4 treatments(i.e. eight head each) were used for 540 days from seven to 24 months of age. The results obtained are summarized as follows; the range of average daily gains was 0.733 to 1.018, 0.994 to 1.255, 0.947 to 1.259 and 0.736 to 0.824kg for the growing, the early-fattening, the mid- fattening and the finishing periods, respectively. The range of average daily gains for the entire period was 0.882 to 1.061kg. The gains were higher for Holstein(7.3%) and the steers(10.5%) than F1 and the heifers, respectively. Concentrates and total digestible nutrients intakes per kg gain were higher for Holstein and the heifers than F1 and the steers, respectively. These findings may indicate that feed utilization is higher for Holstein than F1, and higher for the steers than the heifers. In carcass characteristics, back fat thickness was thicker for Holstein than F1, and rib-eye area was smaller for Holstein than F1. The rib-eye area per kg carcass weight was larger for F1 and the heifers than Holstein and the steers, respectively. Meat color was better for Holstein than F1, but the sex distinction did not show any differences. In physicochemical properties of longissimus dorsi, shear force, cooking loss, water holding capacity and the panel test scores of juiciness, tenderness and flavor for F1 and the heifers were better than those for Holstein and the steers, respectively. According to the above results, we may conclude that F1 and heifers rather than Holstein and steers are recommended for high quality meat production. In steers and heifers of Holstein and F1, the optimal feeding levels may be 1.9% of apparent body weight for concentrates and 25% of concentrates intake for rice straw.
A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.
Ha, J.J.;Rhee, Y.J.;Jang, W.J.;Kim, Y.W.;Shaogang, Li;Song, Y.H.
Journal of Animal Environmental Science
/
v.15
no.1
/
pp.9-16
/
2009
This study, tasting 14 months, was conducted to investigate the effects of different pen size and group size on growing-fattening characteristics of Hanwoo steers. Forty-eight, 12-month-old Hanwoo steers($305.8{\pm}32.2\;kg$) were randomly assigned to three groups($35.28\;m^2$; n=4 heads, $70.56\;m^2$; n=8 heads, $105.84\;m^2$; n=12 heads) and reared in separate pens with a constant space allowance of $8.82m^2$ per head from 12 to 21 month of age and then regrouped to 4 heads per pen. A common diet including concentrate(limited) and forage(ad lib) was provided to all the animals. Images of live animal ultrasonic back fat thickness, longissimus muscle area and Marbling score were evaluated in three months interval from 12 months of age using an ultrasound equipment(HS-2000) at the 13th rib and lumber vertebra interface of left side. Significant differences of ADG was found mainly at $15{\sim}18$ month and $18{\sim}21$ month fattening stages(p<0.05). Marbling score(MS) was higher(p<0.05) in 12 heads group when compared with that of 4 and 8 heads groups after 18 months. Animals in 12 heads group had the lowest Average daily gain(ADG) but showed the highest longissimus muscle area(LMA) and marbling score(MS). In addition, Hanwoo steers in 12 heads group obtained a higher quality appearance(HQA) of 82.7% than that of other treatments. The results indicated that Hanwoo steers housed on large group size and pen size decreased their ADG but improved meat quality.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.