• Title/Summary/Keyword: head & eye field

Search Result 29, Processing Time 0.022 seconds

Design of Diffraction Limited Head Mounted Display Optical System Based on High Efficiency Diffractive Elements

  • Tehrani, Masoud Kavosh;Fard, Sayed Sajjad Mousavi
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.150-156
    • /
    • 2017
  • A diffraction limited optical system for head mounted displays (HMDs) was designed. This optical system consists of four modules, including 1:5 mm and 5:30 mm beam expanders, polarization grating-polarization conversion system (PG-PCS) and refractive/diffractive projection optical module. The PG-PCS module transforms the unpolarized Gaussian beam to a linearly polarized beam and it simultaneously homogenizes the spatial intensity profile. The optical projector module has a $30^{\circ}$ field of view, a 22 mm eye relief, and a 10 mm exit pupil diameter with a compact structure. Common acrylic materials were utilized in the optical design process; therefore, the final optical system was lightweight. The whole optical system is suitable for a 0.7 inch liquid crystal on silicon microdisplay (LCOS) with HDTV resolution ($1920{\times}1080$) and $8.0{\mu}m$ pixel pitch.

Development of a computer mouse using gyro-sensors and LEDs (자이로 센서와 LED를 이용한 마우스 개발)

  • Park, Min-Je;Kang, Shin-Wook;Kim, Soo-Chan
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.701-706
    • /
    • 2009
  • We proposed the device to control a computer with only a head and eye blinks so that disabilities by car accidents can use a computer. Because they have paralysis of their upper extremities such as C4~C5 paraplegics and cerebral palsy, they cannot efficiently access a general keyboard/mouse not using hands and foots. The cursor position was estimated from a gyro-sensor which can measure head movements, and the mouse event such as click/double click from opto-sensors which can detect eye blinks. The sensor was put on the proper goggle in order not to disturb the visual field. The performance of the proposed device was compared to a general optical mouse, and was used both relative and absolute coordinate in cursor positioning control. The recognition rate of click and double-click was 86% of the optical mouse, the speed of cursor movement by the proposed device was not much different from the mouse. The overall accuracy was 80%. Especially, the relative coordinate is more convenience and accuracy than the absolute coordinate, and can reduce the frequency of reset to prevent the accumulative error.

  • PDF

Compact near-eye display for firefighter's self-contained breathing apparatus

  • Ungyeon Yang
    • ETRI Journal
    • /
    • v.45 no.6
    • /
    • pp.1046-1055
    • /
    • 2023
  • We introduce a display for virtual-reality (VR) fire training. Firefighters prefer to wear and operate a real breathing apparatus while experiencing full visual immersion in a VR fire space. Thus, we used a thin head-mounted display (HMD) with a light field and folded optical system, aiming to both minimize the volume for integration in front of the face into a breathing apparatus and maintain adequate visibility, including a wide viewing angle and resolution similar to that of commercial displays. We developed the optical system testing modules and prototypes of the integrated breathing apparatus. Through iterative testing, the thickness of the output optical module in front of the eyes was reduced from 50 mm to 60 mm to less than 20 mm while maintaining a viewing angle of 103°. In addition, the resolution and image quality degradation of the light field in the display was mitigated. Hence, we obtained a display with a structure consistent with the needs of firefighters in the field. In future work, we will conduct user evaluation regarding fire scene reproducibility by combining immersive VR fire training and real firefighting equipment.

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

Head Mouse System Based on A Gyro and Opto Sensors (각속도 및 광센서를 이용한 헤드 마우스)

  • Park, Min-Je;Yoo, Jae-Ha;Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.70-76
    • /
    • 2009
  • We proposed the device to control a computer mouse with only head movements and eye blinks so that disabilities by car or other accidents can use a computer. The mouse position were estimated from a gyro-sensor which can measure head movements, and the mouse events such as click/double click were from opto sensors which can detect the eyes flicker, respectively. The sensor was mounted on the goggle in order not to disturb the visual field. There was no difference in movement speed between ours and a general mouse, but it required 3$\sim$4 more times in the result of the experiment to evaluate spatial movements and events detection of the proposed mouse because of the low accuracy. We could eliminate cumbersome work to periodically remove the accumulated error and intuitively control the mouse using non-linear relative point method with dead zones. Optical sensors are used in the event detection circuitry designed to remove the influence of the ambient light changes, therefore it was not affected in the change of external light source.

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

Anti-Stress Effects of Ginsenoside Rg3-Standardized Ginseng Extract in Restraint Stressed Animals

  • Kim, Chung-Soo;Jo, Young-Jun;Park, Se-Ho;Kim, Hae-Jung;Han, Jin-Yi;Hong, Jin-Tae;Cheong, Jae-Hoon;Oh, Ki-Wan
    • Biomolecules & Therapeutics
    • /
    • v.18 no.2
    • /
    • pp.219-225
    • /
    • 2010
  • We tested whether ginsenosides $Rg_3$-standardized ginseng extract (RGE) has anti-stress effects in restraint-stressed animals. RGE increased time spent in the open arms and open arm entries in the elevated plus-maze test. In addition, RGE blocked the reduction of center zone distance and stereotypes behaviors in the open-field test. RGE also increased head dips in stressed mice, indicating anxiolytic-like effects. Stress decreased movement distance and duration, burrowing, and rearing frequency but increased face washing and grooming. RGE significantly reversed burrowing and rearing activity in stressed mice. In addition, we measured sleep architecture in restraint stressed rats using EEG recorder. Stress increased rapid eye movement (REM) sleep, but total sleep and non-rapid eye movement (NREM) sleep were not changed. RGE did not affect sleep architecture in stressed rats. These behavioral experiments suggest that RGE has anti-stress effects in restraint-stressed animal models.

Upcycling Beauty Design Using Waste (폐기물을 활용한 업사이클링 뷰티디자인)

  • Ming-Yang Cheng;Koh-Mi Cho
    • Fashion & Textile Research Journal
    • /
    • v.25 no.6
    • /
    • pp.732-738
    • /
    • 2023
  • This study delves into the realm of upcycling beauty design by repurposing discarded CDs, magazines, and fabrics. The study outlines a meticulous process for transforming waste into beauty designs. We created three upcycling beauty design works as part of this investigation. The first creation, called Silver Leaf, uses the silver section of CDs to craft leaves and stems. Achromatic colors are used as makeup to achieve cyber-inspired imagery. After carrying out silver-gray eye makeup, the lips were completed by affixing a CD component. The second creation is a firebird crafted by cutting or folding fashion magazines to create essential items. The colorful firebird image was completed using vivid color makeup of shades such as red and yellow. After proceeding with red eye makeup, the lips were completed by cutting and pasting magazine cutouts. The third piece is a spring flower, which involved selectively cutting lace patterns to complete a beauty design extending from head to face. The colors are spring-themed and encompass pink, yellow, and blue. Pink, blue, and green eyeshadows were applied on the lace, attached from head to face, chest, and lips. This study advocates for the prospect of upcycling beauty design using sustainable materials by repurposing waste resources. It also introduces the possibilities of creative activities in this field through upcycling. The study aims to play a role in changing the perception of environmental conservation, a concern of our times, through the use of sustainable resources.

Robust pupil detection and gaze tracking under occlusion of eyes

  • Lee, Gyung-Ju;Kim, Jin-Suh;Kim, Gye-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.11-19
    • /
    • 2016
  • The size of a display is large, The form becoming various of that do not apply to previous methods of gaze tracking and if setup gaze-track-camera above display, can solve the problem of size or height of display. However, This method can not use of infrared illumination information of reflected cornea using previous methods. In this paper, Robust pupil detecting method for eye's occlusion, corner point of inner eye and center of pupil, and using the face pose information proposes a method for calculating the simply position of the gaze. In the proposed method, capture the frame for gaze tracking that according to position of person transform camera mode of wide or narrow angle. If detect the face exist in field of view(FOV) in wide mode of camera, transform narrow mode of camera calculating position of face. The frame captured in narrow mode of camera include gaze direction information of person in long distance. The method for calculating the gaze direction consist of face pose estimation and gaze direction calculating step. Face pose estimation is estimated by mapping between feature point of detected face and 3D model. To calculate gaze direction the first, perform ellipse detect using splitting from iris edge information of pupil and if occlusion of pupil, estimate position of pupil with deformable template. Then using center of pupil and corner point of inner eye, face pose information calculate gaze position at display. In the experiment, proposed gaze tracking algorithm in this paper solve the constraints that form of a display, to calculate effectively gaze direction of person in the long distance using single camera, demonstrate in experiments by distance.

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.