• Title/Summary/Keyword: hazardous

Search Result 2,780, Processing Time 0.026 seconds

Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances (가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과)

  • Cho, Jae-Cheol;Park, Jae-Hwan
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.711-718
    • /
    • 2019
  • Spectrum analyzer and electromagnetic field meter were used to investigate the EM generation behaviour in different types of home electrical appliances. During microwave oven operation, the EM power measured at a point 30cm apart was measured in the range of 8~11mW/㎡, the strength of the low frequency magnetic field was 60~80mG and the electric field strength was measured at 150~160V/m. For smart phone wireless charging pad, it was measured at an electromagnetic power of 0.4mW/㎡, an electric field of 160 V/m and a magnetic field of 1mG at a point 10cm away. For microwave oven and wireless charging pad, if used within 10cm, the size of the electric field has been measured at a large value that exceeds the human body protection standard and may be hazardous to humans. On the other hand, home appliances such as TVs, hairdryers and refrigerators all showed very low levels of electromagnetic waves, electric fields and magnetic fields, with no harmful effects seen. For electromagnetic shielding, the metal Cu fabric and metal foil had a high level of EM shielding, while polymer films had a low EM shielding characteristic.

Exposure to PAHs and VOCs in Residents near the Shinpyeong·Jangrim Industrial Complex (신평·장림 산단 인근 주민의 PAHs 및 VOCs 노출)

  • Yoon, Mi-Ra;Jo, HyeJeong;Kim, GeunBae;Chang, JunYoung;Lee, Chul-Woo;Lee, Bo-Eun
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.2
    • /
    • pp.131-143
    • /
    • 2021
  • Objectives: This study aims to investigate the atmospheric concentration of polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) and the urinary concentration of biomarkers in residents near the Shinpyeong·Jangrim Industrial Complex to compare them with those of residents in a control area. Methods: Hazardous air pollutants (PAHs and VOCs) were measured in an exposure area (two sites) and a control area (one site). Urine samples were collected from residents near the industrial complex (184 persons) and residents in the control area (181 persons). Multiple linear regression analysis was used to identify which factors affected the concentration of PAHs and VOCs metabolites. Results: The average atmospheric concentration of PAHs in Shinpyeong-dong and Jangrim-dong was 0.45 and 0.59 ppb for pyrene, 0.15 and 0.16 ppb for benzo[a]pyrene, and 0.29 and 0.35 ppb for dibenz[a,h]anthracene. The average atmospheric concentration of VOCs was 1.10 and 0.99 ppb for benzene, 8.22 and 11.30 ppb for toluene, and 1.91 and 3.05 ppb for ethylbenzene, respectively. The concentrations of PAHs and VOCs in residents near the Shinpyeong·Jangrim Industrial Complex were higher than those of residents in the control area. Geometric means of urinary 2-hydroxyfluorene, 1-hydroxypyrene, methylhippuric acid, and mandelic acid concentrations were 0.45, 0.22, 391.51, and 201.36 ㎍/g creatinine, respectively. Those levels were all significantly higher than those in the control area (p<0.05). In addition, as a result of multiple regression analysis, even after adjusting for potential confounding factors such as gender and smoking, the concentration of metabolites in urine was high in residents near the Shinpyeong·Jangrim Industrial Complex. Conclusion: The results of this study show the possibility of human exposure to VOCs in residents near the Shinpyeong·Jangrim Industrial Complex. Therefore, continuous monitoring of the local community is required for the management of environmental pollutant emissions.

A Study on the Characteristics of Coffee Ground(CG)-RDF by Using Different Drying Method (건조법에 따른 커피박 고형연료의 특성 고찰 연구)

  • Kim, Sang-bin;Ha, Jin-wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.451-457
    • /
    • 2019
  • In this study, the characteristics of coffee grounds were reviewed by making them from solid fuel through heat-drying and oil-drying method. The differences in the higher calorific power by each dried sample were compared. And industrial analysis using the thermogravimetric analyzer was considered for applicability to organic waste and oily samples. Before and after drying, the surface of the specimen was observed with SEM equipment and the ingredients were measured through the EDS equipment. As a result, no other hazardous substances, such as heavy metals, were measured. Next, The differences between thermal decomposition and combustion reactions were considered through the TG and DTG curves. As a result, it is that the oil-dried coffee grounds is longer to burn than the heat-dried coffee grounds. Finally, the combustion gases emitted through the thermogravimetric analyzer were collected and the carbon monoxide and carbon dioxide performed qualitative and quantitative analysis using GC over time.

The Air Space System and UVA's Regulation in Japanese Civil Aeronautics Act (일본 항공법상의 공역체계와 무인항공기 규제)

  • Kim, Young-Ju
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.2
    • /
    • pp.115-168
    • /
    • 2018
  • An amendment to Japanese Civil Aeronautics Act came into effect December 10, 2015. The Act prohibits flying drones over residential areas or areas surrounding an airport without permission from the Minister of Land, Infrastructure and Transportation. Flying drones during night time and during an event is also prohibited. The term "UAV" or "UA" means any aeroplane, rotorcraft, glider or airship which cannot accommodate any person on board and can be remotely or automatically piloted (Excluding those lighter than a certain weight (200 grams). Any person who intends to operate a UAV is required to follow the operational conditions listed below, unless approved by the Minister of Land, Infrastructure, Transport and Tourism; (i) Operation of UAVs in the daytime, (ii) Operation of UAVs within Visual Line of Sight (VLOS), (iii) Maintenance of a certain operating distance between UAVs and persons or properties on the ground/water surface, (iv) Do not operate UAVs over event sites where many people gather, (v) Do not transport hazardous materials such as explosives by UAV, (vi) Do not drop any objects from UAVs. Requirements stated in "Airspace in which Flights are Prohibited" and "Operational Limitations" are not applied to flights for search and rescue operations by public organizations in case of accidents and disasters. This paper analyzes some issues as to regulations of UAVs in Korean Aviation Safety Act by comparing the regulations of UAVs in Japanese Civil Aeronautics Act. This paper, also, offers some implications and suggestions for regulations of UAVs under Korean Aviation Safety Act.

Area Classification of Hazardous Gas Facility According to KGS GC101 Code (KGS GC101을 통한 가스시설 폭발위험장소의 설정)

  • Kim, Jeong Hwan;Lee, Min-Kyung;Kil, Seong-Hee;Kim, Young-Gyu;Ko, Young Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.46-64
    • /
    • 2019
  • Technical practice code, KGS GC101 2018, for explosion hazard area selection and distance calculation of gas facility was enacted and implemented from July 12, 2018. This code includes whole contents of IEC60079-10-1 2015 (Explosive atmospheres Part 10-1: Classification of areas - Explosive gas atmospheres), and clarifies the interpretation of ambiguous standards or adds guidelines for standards. KGS GC101 is a method for classifying explosion hazard place types: (1) Determination of leak grade (2) Determination of leakage hole size (3) Determination of leakage flow (4) Determination of dilution class (5) Determination of ventilation effectiveness, finally (6) Determination of danger place (7) Explosion The range of dangerous places can be estimated. In order to easily calculate this process, the program (KGS-HAC v1.14, C-2018-020632) composed by Visual Basic for Application (Excel) language was produced by Korea Gas Safety Corporation. We will discuss how to use codes and programs to select and set up explosion hazard zones for field users.

A Study on the Identification of Hazardous Factors and Prevention of Accident in Old Boilers (노후보일러 유해인자 발굴 및 사고예방에 관한 연구)

  • Sa, Min-Hyung;Woo, In-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.1-9
    • /
    • 2019
  • Large-scale industrial boilers operating at high temperature and high pressure, have a large amount of water, and a large amount of energy is released at the time of explosion. Currently, most industrial boilers use gas fuel such as LNG and LPG, etc. and fuel exists in the same space as equipment, so there is a high possibility of secondary damage such as fire or explosion in the event of a boiler accident. Both special care and management are required to operate the very dangerous equipment that causes casualty 2.51 per accident. For boilers of a certain size or more, the Korea Energy Agency conducts inspections in accordance with the Energy Usage Rationalization Act, KS, and public notice of the Ministry of Industry, Trade and Resources. In this research, based on the results of the inspection, the hazard factorss are configured, and a questionnaire is conducted to the inspector, the equipment manager, the maintenance person, and the person in charge of the manufacturer. We analyzed the results by using AHP (Analytic Hierarchy Process). As a result of analysis, generally recognized hazard factorss are not good management, measurement failure, specification failure, water leak, leak analysis, but connection, welding, scale, and corrosion, etc. are relatively less important. It is judged that the adverse factors that are recognized to be highly important among all groups and careers are already well managed, but less important and adverse factors should be well managed to ensure that the safe usage of the boiler.

Association of the Risk of Leukemia and Non-Hodgkin's Lymphoma (NHL) with Environmental Agents (모 지역의 소아 백혈병 및 악성림프종 발병 사례와 환경적 요인의 연관성 조사)

  • Park, Dong-Uk;Choi, Sangjun;Youn, Kanwoo;Kim, So-Yeon;Kim, Hee-Yun;Park, Yun-Kyung;Kim, Won;Iim, Sanghyuk;Park, Jihoon
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.203-212
    • /
    • 2019
  • Objective: A total of five students at same middle school were reported to be diagnosed with pediatric leukemia (n=2), non-Hodgkin's lymphoma (NHL, n=1) and aplastic anemia (n=2) between 2016 and 2017. The aims of this study are to assess exposure to environmental hazardous agents known to be associated with the risk of leukemia and to examine whether the environment of school is associated with the risk leukemia. Method: A total of 11 environmental agents causing childhood leukemia were monitored using international certified method in schools where patients had ever attended. Radon & Thoron detector was used to monitor real-time airborne radon and thoron level ($Bq/m^3$). Clinician interviewed two among nine patients who agreed to participate in this study in order to examine the association of demographic and genetic factors by individually. Leukemia, NHL, and aplastic anemia were grouped into lymphohematopoietic disorder (LHP). Results: Except for airborne radon level, no environmental agents in school and household where patients may be exposed were found to higher than recommended airborne level. Clinical investigation found no individual factors that may be associated with the risk of LHP. Higher airborne radon level than Korea EPA's airborne radon criteria ($148Bq/m^3$) was monitored at most of several after-class room of one elementary school, where two leukemia patients graduated. Significant radon level was not monitored at class-room. Significant exposure to radon of patients was not estimated based on time-activity pattern. Conclusions: Our results have concluded that there have been no environmental factors in school and household environment that may be associated the risk of LHP.

Ring Test as Acute Toxicity Test with Korean Freshwater Shrimp, Neocaridina denticulata using 3,4-Dichloroaniline (국내 서식 담수새우 새뱅이(Neocaridina denticulata)를 이용한 3,4-Dichloroaniline의 급성독성 교차시험(Ring test))

  • Shin, Yu-jin;Lee, Jae-woo;Kim, Jieun;Cho, Jaegu;Kim, Ja-Hyun;Kang, Minho;Kim, Kyungtae;Kim, Pil-je;Park, Kyunghwa
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.285-294
    • /
    • 2019
  • Objectives: For suitable risk management of the domestic aquatic environment, it is necessary to conduct toxicity tests using species native to Korea. In the present study, we performed toxicity ring tests using endemic freshwater arthropoda Neocaridina denticulata and evaluated its validity and reproducibility as an international standard test species. Methods: To evaluate the sensitivity levels of N. denticulata to hazardous chemicals, toxicity values for several chemicals were compared with other standard test species. Intra- and inter-laboratory acute toxicity tests were performed both within a single laboratory and among four laboratories respectively using 3,4-Dichloroaniline, which is generally used as a reference test substance in fish toxicity tests. In addition, intra- and inter-laboratory coefficient of variations (CVs) were calculated to evaluate reproducibility based on the estimated toxicity values. Results: The sensitivity of N. denticulata to several chemicals was found to be similar with D. manga, indicating that the species is valid as a test species. The CVs of the intra- and inter-laboratory tests were 22.946% with four qualified runs and 8.828% among the four laboratories, respectively. Conclusions: N. denticulata serves in an important role in the food chain of Korean aquatic ecosystems and also inhabits several other Asian countries. Since the validity and reproducibility of the species were confirmed as a toxicity test species in this study, further efforts are needed to establish N. denticulata as the international standard test species for the appropriate risk assessment of aquatic ecosystems at home and abroad.

Cellular Automata Simulation System for Emergency Response to the Dispersion of Accidental Chemical Releases (사고로 인한 유해화학물질 누출확산의 대응을 위한 Cellular Automata기반의 시뮬레이션 시스템)

  • Shin, Insup Paul;Kim, Chang Won;Kwak, Dongho;Yoon, En Sup;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.136-143
    • /
    • 2018
  • Cellular automata have been applied to simulations in many fields such as astrophysics, social phenomena, fire spread, and evacuation. Using cellular automata, this study develops a model for consequence analysis of the dispersion of hazardous chemicals, which is required for risk assessments of and emergency responses for frequent chemical accidents. Unlike in cases of detailed plant safety design, real-time accident responses require fast and iterative calculations to reduce the uncertainty of the distribution of damage within the affected area. EPA ALOHA and KORA of National Institute of Chemical Safety have been popular choices for these analyses. However, this study proposes an initiative to supplement the model and code continuously and is different in its development of free software, specialized for small and medium enterprises. Compared to the full-scale computational fluid dynamics (CFD), which requires large amounts of computation time, the relative accuracy loss is compromised, and the convenience of the general user is improved. Using Python open-source libraries as well as meteorological information linkage, it is made possible to expand and update the functions continuously. Users can easily obtain the results by simply inputting the layout of the plant and the materials used. Accuracy is verified against full-scale CFD simulations, and it will be distributed as open source software, supporting GPU-accelerated computing for fast computation.

Estimation of PM10 and PM2.5 inhalation dose by travel time and respiratory volume in common transport microenvironments in Seoul, Korea (서울지역 교통수단별 이동시간과 호흡량을 고려한 미세먼지 흡입량 추정에 관한 연구)

  • Lee, Yong-Il;Jung, Wonseck;Hwang, Doyeon;Kim, Taesung;Park, Duckshin
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.97-105
    • /
    • 2018
  • Recently, people's interest in particulate matter (PM) has been increasing, due to its hazardous health effects. The purpose of this study was to investigate the concentrations and as well as the inhaled weight of PM, correlated with person's heart rate in subway, bus, vehicle and bicycle in the major public transportation (Sadang - Jamsil and Nowon - Dongdaemun) in Seoul. The concentration of $PM_{10}$ and $PM_{2.5}$ were measured from each of transportation means and calculated the average concentrations which were 87.2 and $57.8{\mu}g/m^3$ for subway, 62.8 and $42.5{\mu}g/m^3$ for vehicle, 61.5 and $36.8{\mu}g/m^3$ for bus and 53.0 and $29.4{\mu}g/m^3$ for bicycle in $PM_{10}$ and $PM_{2.5}$ respectively. Inhalation dose for $PM_{10}$ and $PM_{2.5}$ were estimated at 248.1 and $139.4{\mu}g$ for bicycle, 56.7 and $39.3{\mu}g$ for vehicle, 49.4 and $29.9{\mu}g$ for bus and 44.3 and $29.1{\mu}g$ for subway, respectively. Even though subway had the highest concentration, the highest inhalation dose was the bicycle. It was due to the long travel time-exposure and breathing rate which leads to maximum of $PM_{10}$ 5.6 and $PM_{2.5}$ with 4.8 times inhalation dose comparing with other modes of transportation. With regards to future studies, the amount of inhalation in each transportation means should be considered in risk assessments of PM.