• 제목/요약/키워드: harmonics compensation

검색결과 195건 처리시간 0.028초

Real-Time Implementation of Shunt Active Filter P-Q Control Strategy for Mitigation of Harmonics with Different Fuzzy M.F.s

  • Mikkili, Suresh;Panda, Anup Kumar
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.821-829
    • /
    • 2012
  • This research article presents a novel approach based on an instantaneous active and reactive power component (p-q) theory for generating reference currents for shunt active filter (SHAF). Three-phase reference current waveforms generated by proposed scheme are tracked by the three-phase voltage source converter in a hysteresis band control scheme. The performance of the SHAF using the p-q control strategy has been evaluated under various source conditions. The performance of the proposed control strategy has been evaluated in terms of harmonic mitigation and DC link voltage regulation. In order to maintain DC link voltage constant and to generate the compensating reference currents, we have developed Fuzzy logic controller with different (Trapezoidal, Triangular and Gaussian) fuzzy M.F.s. The proposed SHAF with different fuzzy M.F.s is able to eliminate the uncertainty in the system and SHAF gains outstanding compensation abilities. The detailed simulation results using MATLAB/SIMULINK software are presented to support the feasibility of proposed control strategy. To validate the proposed approach, the system is also implemented on a real time digital simulator and adequate results are reported for its verifications.

계통전압 왜곡 및 불평형시 3상 계통연계인버터의 계통전류제어 기법 (Grid Current Control Scheme at Thee-Phase Grid-Connected Inverter Under Unbalanced and Distorted Grid Voltage Conditions)

  • ;전태원
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1560-1565
    • /
    • 2013
  • This paper proposes the control method for compensating for unbalanced grid current and reducing a total harmonic distortion (THD) of the grid current at the three-phase grid-connected inverter systems under unbalancd and distorted grid voltage conditions. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for a minimum point of THD. Both the gain and angle of a compensation voltage at the minimum point of THD of the grid current are derived. The negative-sequence components in the three-phase unbalanced grid voltage are cancelled in order to achieve the balanced grid current. The simulation and experimental results show the validity of the proposed control methods.

PWM인버터에서 스위칭시간지연이 미치는 효과의 분석 및 그 보상 (The Analysis and Compensation of Switching Time Delay in PWM Inverters)

  • 박민호;홍순찬;정승기
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.58-66
    • /
    • 1991
  • In inverters, time delays are inserted in the switching signals to prevent the dc lind shortage. This causes detrimental effects on the performance of the inverters, that is, the fundamental voltage drop and the generation of low order harmonics. This paper derives simple formula to describe the time delay effects in PWM inverters, where the effects may become significant because of relatively high switching frequencies. To compensate the tice delay effects, this paper presents two methods which are suitable for sinusoidal PWM and memory-based PWM respectively. Both are simple, easy to implement, and are shown to be effective, through the experiments, in improving the output waveform of PWM inverters.

  • PDF

순간정전에 대한 보상능력을 갖는 UPQC(Unified Power Quality Conditioner)의 성능해석 (Performance Analysis of UPQC(Unified Power Quality Conditioner) with Compensation Capability for Voltage Interruption)

  • 김희중;배병열;한병문;설승기;조보형
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.279-286
    • /
    • 2003
  • A new UPQC(unified power quality conditioner), which consists of series inverter, shunt inverter, dc/dc converter, and energy storage, is proposed. The proposing UPQC can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance, and voltage interruption. The control strategy for the proposing UPWQC was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the EMTDC/PSCAD simulation and the experimental work with the hardware prototype. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems or industrial power systems and can be utilized for the custom power device in the future distribution system.

전압sag-swell과 고조파 보상기능을 갖는 Z-소스 전력품질보상시스템 (Z-source power quality conditioner with compensation capability of voltage sag-swell and harmonics)

  • 박희재;오승열;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.290-292
    • /
    • 2009
  • 본 연구에서는 배전계통의 전압 및 전류 품질을 통합적으로 개선할 수 있는 수동필터 연계형 Z-소스 전력품질 보상 시스템을 제안한다. 제안된 시스템의 주안점은 전압의 변동을 보상하는 직렬형 인버터와 고조파를 보상하는 병렬형 인버터에 각각 Z-소스 토폴로지를 적용하는 것이다. 전압 sag와 swell이 발생하는 과도상태에서 제안된 시스템의 성능을 검증하기 위하여 PSIM시뮬레이션을 하여 타당성을 입증하였다.

  • PDF

Harmonic Elimination and Reactive Power Compensation with a Novel Control Algorithm based Active Power Filter

  • Garanayak, Priyabrat;Panda, Gayadhar
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1619-1627
    • /
    • 2015
  • This paper presents a power system harmonic elimination using the mixed adaptive linear neural network and variable step-size leaky least mean square (ADALINE-VSSLLMS) control algorithm based active power filter (APF). The weight vector of ADALINE along with the variable step-size parameter and leakage coefficient of the VSSLLMS algorithm are automatically adjusted to eliminate harmonics from the distorted load current. For all iteration, the VSSLLMS algorithm selects a new rate of convergence for searching and runs the computations. The adopted shunt-hybrid APF (SHAPF) consists of an APF and a series of 7th tuned passive filter connected to each phase. The performance of the proposed ADALINE-VSSLLMS control algorithm employed for SHAPF is analyzed through a simulation in a MATLAB/Simulink environment. Experimental results of a real-time prototype validate the efficacy of the proposed control algorithm.

전력품질로 인한 아파트 수용가 승강기의 전기적 설비 영향에 관한 연구 (A Study on electrical equipment effect of apartment customer elevator by power quality)

  • 이희태;김재철;강장규;김기현;설규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.304-305
    • /
    • 2006
  • Now there is utilization of elevator increasing continuously, it is one of electrical facilities taking a serious view safety. However, elevator comfortable ride is researched generally Recently aging condition, equipment life, malfunction, other applicancies of power electronics and equipment disturbance effect on power quality and prevention measures are much researches in advanced nation. but awareness is lacking real condition up to now in domestic. Voltage sag, swell, harmonics, surge etc of elevator system is important problem about human safety. and there are many quality compensation to solve these problem of elevator. So to evaluate these problem, in this paper, displayed result through computer simulation for converter of problem, and inverter part by power quality problem in power distribution system.

  • PDF

단상 전력용 능동필터형 무정전 전원장치 (Active Power Filter Type Single Phase Uninterruptible Power Supply(UPS) System)

  • 김제홍;손재현
    • 전자공학회논문지T
    • /
    • 제36T권4호
    • /
    • pp.53-59
    • /
    • 1999
  • 본 논문에서는 전력용 능동필터의 성능을 가지는 양방향성 무정전 전원장치를 제안한다. 제안된 시스템은 전력용 능동필터모드와 배터리 방전전력모드인 2가지 모드로 나누어진다. 전력용 능동필터모드에서 고조파전류와 무효전력을 효과적으로 보상하기 위하여 기준전류를 계산하는데, 새로운 폐-루프 제어기법이 사용된다. 마지막으로, 제안된 무정전 전원장치의 성능이 시뮬레이션과 실험에 의해 검증된다.

  • PDF

배전계통에서 UPFC를 이용한 순시전압상승 보상 (Voltage Swell Compensation using an UPFC in Distribution System)

  • 장원혁;이상봉;이명희;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.488-489
    • /
    • 2008
  • Based on the fact that renewable energies such as photovoltaic, wind power, etc. are increasingly used in distribution systems recently which affects overvoltage, this paper implements an unified power flow controller(UPFC) to compensate voltage swell. The implemented scheme employs an ac chopper and a low-pass filter along with a series transformer. The ac chopper converts the amplitude of the voltage down to the nominal value. The low pass filter makes the rough waveform of the output voltage of the ac chopper due to switching smoothly by eliminating harmonics. To verify the effectiveness of the implemented UPFC, the results by Electro-Magnetic Transients Program(EMTP) are presented for various overvoltage cases.

  • PDF

유도전동기 운전 중 Sag 영향에 의한 고조파 차수 변화 (Induction Motor of Effect for Variation Sag, Swell of Harmonic Order)

  • 박인덕;이승환;김시경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.954-955
    • /
    • 2008
  • In this paper, the voltage harmonics are investigated in terms of the voltage sag versus the time constants of electric machinery under the source voltage variation condition. The electric machinery and compensation equipment are established on the proposed design scheme based on voltage quality effect assessment technology. It have been analyzed how the variation of harmonic order, the output current, the DC-Link voltage and the induction motor speed is carried out under the voltage sag and switching frequency variation.

  • PDF