The Calculation of Illuminance Distribution in Complex Interior using Montecarlo Simulation (몬테카를로 시뮬레이션을 이용한 다면 공간의 조도계산)

  • Kim, Hee-Chul;Chee, Chul-Kon;Kim, Hoon
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.6
    • /
    • pp.27-33
    • /
    • 1993
  • In order to improve complicated construction and complex control which are didvantage of optimal PWM technique aimed at harmonic elimination method, this paper presented MRA(Mode1 Reference Adaptive) PWM technique that gating signal of inverter is generated by comparing the reference signal with the induced feedback signal at the reference model of load. Design of controller is composed of microprocessor and analog circuit. MRA PWM technique used in the paper is able to compensate the degradation of voltage efficiency to be generated by the ratio of the output voltage to the DC supply voltage being low for using conventional sinusoidal PWM technique. When the trapezoidal signal is employed as the reference signal. the low order harmonics of line current can be reduced and the switching pattern is made by on-line computation using comparatively simple numerical analysis.

  • PDF

A Study on The MRA PWM Technique Using the Trapezoidal Waveform at Voltage Source Inverter(VSDI) (전압형 인버터(VSI)에서 사다리꼴파형을 이용한 MRA PWM 기법에 관한 연구)

  • 한완옥;원영진;이성백
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.36-40
    • /
    • 1993
  • In order to improve complicated construction and complex control which are disadvantage of optimal PWM technique aimed at harmonic elimination method, this paper presented MRA(Model Reference Adaptive) PWM technique that gatmg signal of inverter is generated by comparing the reference signal with the induced feedback signal at the reference model of load. Design of controller is composed of microprocessor and analog circuit. MRA PWM technique used in the paper is able to compensate the degradation of voltage efficiency to be generated by the ratio of the output voltage to the DC supply voltage being low for using conventional sinusoidal PWM technique. When the trapezoidal signal is employed as the reference signal. the low order harmonics of line current can be reduced and the switching pattern is made by on-line computation using comparatively simple numerical analysis.

  • PDF

A study on the PWM(pulse witdh modulation) current source Inverter with utility (태양광발전 연계 시스템에 의한 PWM 전류형 인버어터에 관한 연구)

  • Hwang, Lak-Hoon;Choi, Ho-Kyu;Sin, Yang-Ho;Lee, Chun-Sang;Kim, Ju-Rae;Jo, Sang-Rou;Jo, Moon-Taeck
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1020-1022
    • /
    • 2001
  • because the output of solar cell is direct, it is necessary to install D/A converter system for A.C load, and in case of driving utility line system, it is possible to drive system relation when the system supplies sinusodal current ant voltage having unit power factor. As the characteristics of the soar cell output the is influenced by dailysunight charge, for more electric power it is essential to control the direction toward the san so that the driving point of solar cell can always operate near maximum output point. PWM modulation device among electric power converters must have stable modulation at anytime when it includes noise-factors such as noise-wave and noises on electric voltage wave, a synchronous signal system. In dealing with synchronous signal for control and control signal by microprocessor, it is necessary to compensate it because there is time difference between sample paint and carrier wave. On this papers, single phase PWM current type invertor controled the solar cell having typical voltage dropping character has optimun short current in short, reduces D.C reactance, composes controller for modulation and keeps lower harmonic and high power factor keeping maximum output of solar cell according daily sunlight charge variation.

  • PDF

A Novel Third-Order Cascaded Sigma-Delta Modulator using Switched-Capacitor (스위치형 커패시터를 이용한 새로운 형태의 3차 직렬 접속형 시그마-델타 변조기)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.197-204
    • /
    • 2010
  • This paper proposes a new body-effect compensated switch configuration for low voltage and low distortion switched-capacitor (SC) applications. The proposed circuit allows rail-to-rail switching operation for low voltage SC circuits and has better total harmonic distortion than the conventional bootstrapped circuit by 19 dB. A 2-1 cascaded sigma-delta modulator is provided for performing the high-resolution analog-to-digital conversion on audio codec in a communication transceiver. An experimental prototype for a single-stage folded-cascode operational amplifier (opamp) and a 2-1 cascaded sigma-delta modulator has been implemented m a 0.25 micron double-poly, triple-metal standard CMOS process with 2.7 V of supply voltage. The 1% settling time of the opamp is measured to be 560 ns with load capacitance of 16 pF. The experimental testing of the sigma-delta modulator with bit-stream inspection and analog spectrum analyzing plot is performed. The die size is $1.9{\times}1.5\;mm$.

Three Phase Embedded Z-Source Inverter (3상 임베디드 Z-소스 인버터)

  • Oh, Seung-Yeol;Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.486-494
    • /
    • 2012
  • In this paper, we proposes the three-phase embedded Z-source inverter consisting of the three embedded Z-source converters and it's the output voltage control method. Each embedded Z-source converter can produce the bipolar output capacitor voltages according to duty ratio D such as single-phase PWM inverter. The output AC voltage of the proposed system is obtained as the difference in the output capacitor voltages of each converter, and the L-C output filter is not required. Because the output AC voltage can be stepped up and down, the boost DC converter in the conventional two-stage inverter is unnecessary. To confirm the validity of the proposed system, PSIM simulation and a DSP based experiment were performed under the condition of the input DC voltage 38V, load $100{\Omega}$, and switching frequency 30kHz. Each converter is connected by Y-connection for three-phase loads. In case that the output phase voltage is the same $38V_{peak}$ as the input DC voltage and is the 1.5 times($57V_{peak}$), the simulation and experimental results ; capacitor voltages, output phase voltages, output line voltages, inductor currents, and switch voltages were verified and discussed.

Design of a Dual Band High PAE Power Amplifier using Single FET and Class-F (Single FET와 Class-F급을 이용한 이중대역 고효율 전력증폭기 설계)

  • Kim, Seon-Sook;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.1
    • /
    • pp.110-114
    • /
    • 2008
  • In this paper, high efficient class F power amplifier with dual band has been realized. Dual band power amplifier have used modify stub matching for single FET, center frequency 2.14GHz and 5.2GHz respectively. Dual band amplifier is 32.65dBm output power, gain 11dB and PAE 36% at the 2.14GHz, 7dB gain at the 5.2GHz. Design of a dual band class F power amplifier using harmonic control circuit. The measured are 9.9dB gain, 30dBm output power and PAE 55% at the 2.14GHz, 11.7dB gain at the 5.2GHz. This paper is being used the load-pull method and it maximizes output power and it is using the only one transistor in the paper. As a result, this research will obtain a dual band high PAE power amplifier.

AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System (인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어)

  • Park, Gwi-Geun;Choi, Jae-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

Determination of the Coefficient of Variation of Shear Wave Velocity in Rock Filled Zone of CFRD (Concrete Faced Rock Filled Dam) for Reliability Based Analysis (신뢰성 기반 해석을 위한 국내 CFRD 사력존 재료의 전단파 속도 변동계수 결정)

  • Park, Hyung-Choon;Lim, Heui-Dae
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.4
    • /
    • pp.17-24
    • /
    • 2017
  • Shear wave velocity (or shear modulus) of rock filled zone of CFRD is very important factor in the evaluation of performance of CFRD under the load such as earthquake. A shear wave velocity profile can be determined by surface wave method but this profile has been uncertainty caused by spatial variation of material property in rock filled zone. This uncertainty in shear wave velocity profile could be evaluated by the reliability based analysis which uses a coefficient of variation of material property to consider uncertainty caused by spatial variation of material property. In this paper, the possible 600 shear wave velocity profiles in rock filled zone of CFRD were generated using the method based on harmonic wavelet transform and 8 shear wave velocity profiles by HWAW method in the field, and the coefficients of variation of shear wave velocity with depth were evaluated for the rock filled zone of CFRD in Korea.

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

Pressure loading, end- shortening and through- thickness shearing effects on geometrically nonlinear response of composite laminated plates using higher order finite strip method

  • Sherafat, Mohammad H.;Ghannadpour, Seyyed Amir M.;Ovesy, Hamid R.
    • Structural Engineering and Mechanics
    • /
    • v.45 no.5
    • /
    • pp.677-691
    • /
    • 2013
  • A semi-analytical finite strip method is developed for analyzing the post-buckling behavior of rectangular composite laminated plates of arbitrary lay-up subjected to progressive end-shortening in their plane and to normal pressure loading. In this method, all the displacements are postulated by the appropriate harmonic shape functions in the longitudinal direction and polynomial interpolation functions in the transverse direction. Thin or thick plates are assumed and correspondingly the Classical Plate Theory (CPT) or Higher Order Plate Theory (HOPT) is applied. The in-plane transverse deflection is allowed at the loaded ends of the plate, whilst the same deflection at the unloaded edges is either allowed to occur or completely restrained. Geometric non-linearity is introduced in the strain-displacement equations in the manner of the von-Karman assumptions. The formulations of the finite strip methods are based on the concept of the principle of the minimum potential energy. The Newton-Raphson method is used to solve the non-linear equilibrium equations. A number of applications involving isotropic plates, symmetric and unsymmetric cross-ply laminates are described to investigate the through-thickness shearing effects as well as the effect of pressure loading, end-shortening and boundary conditions. The study of the results has revealed that the response of the composite laminated plates is particularly influenced by the application of the Higher Order Plate Theory (HOPT) and normal pressure loading. In the relatively thick plates, the HOPT results have more accuracy than CPT.