• 제목/요약/키워드: hand measurement

검색결과 1,076건 처리시간 0.033초

Automatic Hand Measurement System from 2D Hand Image for Customized Glove Production

  • Han, Hyun Sook;Park, Chang Kyu
    • 한국의류산업학회지
    • /
    • 제18권4호
    • /
    • pp.468-476
    • /
    • 2016
  • Recent advancements in optics technology enable us to realize fast scans of hands using two-dimensional (2D) image scanners. In this paper, we propose an automatic hand measurement system using 2D image scanners for customized glove production. To develop the automatic hand measurement system, firstly hand scanning devices has been constructed. The devices are designed to block external lights and have user interface to guide hand posture during scanning. After hands are scanned, hand contour is extracted using binary image processing, noise elimination and outline tracing. And then, 19 hand landmarks are automatically detected using an automatic hand landmark detection algorithm based on geometric feature analysis. Then, automatic hand measurement program is executed based on the automatically extracted landmarks and measurement algorithms. The automatic hand measurement algorithms have been developed for 18 hand measurements required for custom-made glove pattern making. The program has been coded using the C++ programming language. We have implemented experiments to demonstrate the validity of the system using 11 subjects (8 males, 3 females) by comparing automatic 2D scan measurements with manual measurements. The result shows that the automatic 2D scan measurements are acceptable in the customized glove making industry. Our evaluation results confirm its effectiveness and robustness.

Anslysis of tool grip tasks using a glove-based hand posture measurement system

  • Yun, Myung Hwan;Freivalds, Andris;Lee, Myun W.
    • 대한인간공학회지
    • /
    • 제14권1호
    • /
    • pp.69-81
    • /
    • 1995
  • Few studies on the biomechanical analysis of hand postures and tool handling tasks exist because of the lack of appropriate measurement techniques for hand force. A measurement system for the finger forces and joint angles for the analysis of manual tool handling tasks was developed in this study. The measurement system consists of a force sensing glove made from twelve Force Sensitive Resistors and an angle-measuring glove (Cyberglove$^{TM}$, Virtual technologies) with eighteem joint angle sensors. A biomechanical model of the hand using the data from the measurement system was also developed. Systems of computerized procedures were implemented inte- grating the hand posture measurement system, biomechanical analysis system, and the task analysis system for manual tool handling tasks. The measurement system was useful in providing the hand force data needed for an existing task analysis system used in CTD risk evaluation. It is expected that the hand posture measurement developed in this study will provide an efficient and cost-effective solution to task analysis of manual tool handling tasks.s.

  • PDF

손 치수 측정을 위한 3차원 반자동 측정 방법 개발 (Development of a 3D Semi-Automatic Measurement Protocol for Hand Anthropometric Measurement)

  • 이원섭;윤성혜;유희천
    • 산업공학
    • /
    • 제24권2호
    • /
    • pp.105-111
    • /
    • 2011
  • Measurement protocols for hand anthropometry have been studied for ergonomic product design. The present study developed a 3D semi-automatic measurement protocol (3D-SAMP) which semi-automatically measures various hand dimensions using a 3D scanner. The 3D-SAMP was compared with the conventional direct measurement method (DMM) to examine its effectiveness. The 3D-SAMP consists of (1) fabricating a plaster cast of the hand, (2) placing landmarks on the plaster hand, (3) scanning the plaster hand with a 3D scanner, (4) identifying automatically the positions of the landmarks on the digital hand, and (5) extracting automatically hand anthropometric measurements (lengths, widths, thicknesses, and circumferences). An evaluation experiment conducted in the study found the 3D-SAMP preferred to the DMM in terms of reliability (the number of dimensions exceeding the variability criteria SD=2 mm and CV=5% : 3D-SAMP =2 and DMM=24) and ease of measurement (3D-SAMP=5.2 and DMM=4.3 out of 7). The 3D-SAMP can be applied to ergonomic design of a hand-held product.

초소형 3축 가속도계를 이용한 수전달 진동 측정에 관한 연구 (Measurement of the hand-transmitted vibration using a miniature 3-axes accelerometer)

  • 송치문;장한기;김승한;채장범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1043-1047
    • /
    • 2003
  • Most of the measurement and the evaluation of hand-transmitted vibration have been performed by using a small size single axis accelerometer between the handle and the hand palm or a three axis accelerometer attached on an adapter outside the hand(indirect measurement). It is most desirable for the correct evaluation of hand-transmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm in the three axis(direct measurement) as recommended in ISO 5349-1. In the study three axes acceleration measurement device was developed of which the thickness was less than 7mm so that it can be placed between the handle and the palm without any inconvenience during the measurement. To verify the performance of the developed device, measured acceleration by the two methods, direct and indirect, were compared in the study.

  • PDF

Analysis of tool grip tasks using a glove-based hand posture measurement system

  • Yun, Myung-Hwan;Freivalds, Andris;Lee, Myun-W.
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1994년도 춘계공동학술대회논문집; 창원대학교; 08월 09일 Apr. 1994
    • /
    • pp.596-605
    • /
    • 1994
  • An efficient measurement and evaluation system for hand tool tasks will provide a practical solution to the problem of designing and evaluating manual tool tasks in the workplace. Few studies on the biomechanical analysis of hand postures and tool handling tasks exist because of the lack of appropriate measurement techniques for hand force. A measurement system for the finger forces and joint angles for analysis of manual tool handling tasks was developed in this study. The measurement system consists of a force sensing glove made from twelve Force Sensitive Resistors and an angle-measuring glove (Cyberglove$\^$TM/, Virtual technologies) with eighteen joint angle sensors. A biomechanical model of the hand using the data from the measurement system was also developed. Systems of computerized procedures were implemented integrating the hand posture measurement system, biomechanical analysis system, and the task analysis system for manual tool handling tasks. The measurement system was useful in providing the hand force data needed for an existing task analysis system used in CTD risk evaluation. It is expected that the hand posture measurement developed in this study will provide an, efficient and cost-effective solution to task analysis of manual tool handling tasks. These tasks are becoming increasingly important areas of occupational health and safety of the country.

손 힘 사용 측정 FSA 시스템의 성능 평가 (Evaluation of the FSA Hand Force Measurement System)

  • 정기효;유희천;권오채
    • 대한인간공학회지
    • /
    • 제24권2호
    • /
    • pp.45-49
    • /
    • 2005
  • The FSA(Force Sensitive Application) system measures hand force by using force resistance sensors. Compared to conventional hand force measurement systems such as Lafayette hand dynamometer and Jamar hydraulic hand dynamometer, the FSA system can be applied to analyze use of hand forces while the hand is manipulating objects for a task, However, the measurement performance of the FSA system has not been objectively evaluated. The present study tested the FSA system in terms of stability, repeatability, accuracy, and linearity. It is shown that the FSA system has good stability (CV$\leq$0.02) and linearity($R^2$=0.82), but has low repeatability(CV=$0.11{\sim}0.19$) and accuracy(22% of underevaluation on average). This performance result indicates that measurements from the FSA system should be used for relative comparison rather than for absolute comparison.

양손 임피던스법에 의한 SV 측정의 정확도 향상을 위한 연구 (A Study on Improvement of the Accuracy of SV Measurement obtained by Hand to Hand Impedance.)

  • 윤찬솔;염호준
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1251-1255
    • /
    • 2015
  • The purpose of this study is to measurement the cardiac output using hand to hand impedance method to provide convenience to user when measuring SV(stroke volume) with the use of ICG(Impedance Cardiography). We suggest the optimized modified formula, which can be applied when using impedance with the use of hand to hand Impedance. To verify this formula, a SV from transthoracic approach and hand to hand approach are compared for the 36 subjects, respectively. The acquired data was analyzed by using LabVIEW 8.6, analysis was implemented by SPSS 12.0. Fine difference was shown by individual. We showed that as a result of analyzing the ICG measurement value on thoracic and hand to hand, the correlation with SV was r=0.716, thereby having indicated the results of regression model in relatively high correlation.

시뮬레이션 환경에서 사진측량기법을 이용한 손 치수 측정 방법에 대한 연구 (An Approach to Measure Anthropometric Data of Simulated Human Hand Using Photogrammetry)

  • 장지홍
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권5호
    • /
    • pp.511-517
    • /
    • 2016
  • 손 부위의 인체측정자료는 시용자중심 설계의 관점에서 수부와 관련된 다양한 제품의 설계에 중요한 요소이다. 전통적인 인체치수조사에서 측정자를 사용하는 직접측정법은 측정 시간의 누적, 원천 자료 미확보, 측정자간 신뢰도 등에 대한 단점을 가지고 있다. 이를 보완하기 위한 3D 스캐너는 고비용, 이동성 제한 등의 단점을 가지고 있다. 이러한 단점들을 보완할 수 있는 사진측량법에 의한 손 부위 인체측정자료의 효율적인 수집에 관한 연구를 수행하였다. 직/간접 측정 결과의 비교 과정에서 발생할 수 있는 오차를 최소화하기 위하여 시뮬레이션 환경에서 직/간접 측정을 실시하였다. 사진측량법을 이용한 손 부위 인체치수의 측정 가능성을 확인하였다.

A Measurement System for 3D Hand-Drawn Gesture with a PHANToMTM Device

  • Ko, Seong-Young;Bang, Won-Chul;Kim, Sang-Youn
    • Journal of Information Processing Systems
    • /
    • 제6권3호
    • /
    • pp.347-358
    • /
    • 2010
  • This paper presents a measurement system for 3D hand-drawn gesture motion. Many pen-type input devices with Inertial Measurement Units (IMU) have been developed to estimate 3D hand-drawn gesture using the measured acceleration and/or the angular velocity of the device. The crucial procedure in developing these devices is to measure and to analyze their motion or trajectory. In order to verify the trajectory estimated by an IMU-based input device, it is necessary to compare the estimated trajectory to the real trajectory. For measuring the real trajectory of the pen-type device, a PHANToMTM haptic device is utilized because it allows us to measure the 3D motion of the object in real-time. Even though the PHANToMTM measures the position of the hand gesture well, poor initialization may produce a large amount of error. Therefore, this paper proposes a calibration method which can minimize measurement errors.

한국 성인 여성의 손 계측연구 -장갑의 치수 설정을 중심으로- (A Study on the Measurement of Korean Women′s Hand -Focusing on Glove Size-)

  • 류경옥;서미아
    • 복식문화연구
    • /
    • 제12권2호
    • /
    • pp.262-278
    • /
    • 2004
  • The purpose of this study was to develop the sizing system fur women's glove. The combination of anthropometric and engineering aspects of glove pattern-making is difficult problem in engineering clothing. And the traditional measurements is not enough for glove. Therefore, to develop the hand measurement method and dimension for glove, a comprehensive list of candidate measurements was reviewed and the manufacturers (Their career was over the 15years.) were interviewed on the method of glove pattern-making. This study was conducted traditional and creative 88 two-dimensional anthropometric measurements and 4 photometric measurements for glove pattern-making. In addition, 16 creative measurements were instrumented using a special hand measuring board for measuring of landmark locations on the hand. The subjects were 260 women's right hand in the age group of 18 to 35 years old in Korea.

  • PDF