Evaluation of the FSA Hand Force Measurement System

손 힘 사용 측정 FSA 시스템의 성능 평가

  • 정기효 (포항공과대학교 기계산업공학부 제품생산기술연구소) ;
  • 유희천 (포항공과대학교 기계산업공학부 제품생산기술연구소) ;
  • 권오채 (포항공과대학교 기계산업공학부 제품생산기술연구소)
  • Published : 2005.05.31

Abstract

The FSA(Force Sensitive Application) system measures hand force by using force resistance sensors. Compared to conventional hand force measurement systems such as Lafayette hand dynamometer and Jamar hydraulic hand dynamometer, the FSA system can be applied to analyze use of hand forces while the hand is manipulating objects for a task, However, the measurement performance of the FSA system has not been objectively evaluated. The present study tested the FSA system in terms of stability, repeatability, accuracy, and linearity. It is shown that the FSA system has good stability (CV$\leq$0.02) and linearity($R^2$=0.82), but has low repeatability(CV=$0.11{\sim}0.19$) and accuracy(22% of underevaluation on average). This performance result indicates that measurements from the FSA system should be used for relative comparison rather than for absolute comparison.

Keywords

References

  1. Ayoub, M. A., Ergonomic deficiencies: I. Pain at work. Journal of Occupational Medicine, 32(1), 52-57, 1990 https://doi.org/10.1097/00043764-199001000-00014
  2. AboutTime, Introduction about AboutTime. Retrived April 1, 2004 from http://www.arachnoid.com/abouttime/, 2004
  3. Kessler, G. D., Hodges, L. F. and Walker, N., Evaluation of the cyberglove as a whole-hand input device. ACM Transactions on Computer-Human Interface, 2(4), 263-283, 1995 https://doi.org/10.1145/212430.212431
  4. National Institute for Occupational Safety and Health (NIOSH), Musculoskeletal Disorders (MSDs) and Workplace Factors: A Critical Review of Epidemiologic Evidence for Work-Related Musculoskeletal Disorders of the Neck, Upper Extremity, and Low Back (2nd printing). Cincinnati, OH: U.S. Department of Health and Human Services (DHHS), 1997
  5. NexGen, FSA glove pressure mapping system. Retrieved April 1, 2004 from http://www.nexgenergo.com/ergonomics/fsaglove.html, 2004
  6. NK BioTechnical Corporation, NK Dynamometer User's Manual, 2003
  7. Putz-Anderson, V., Cumulative Trauma Disorders: A Manual for Musculoskeletal Diseases of the Upper Limbs. Taylor & Francis: New York, 1988
  8. Quam, D., Williams, G., Agnew, J. and Browne, P., An experimental determination of human hand accuracy with a dataglove. In Proceedings of the Human Factors Society 33rd Annual Meeting. Human Factors Society, Santa Monica, Calif., 315-319, 1989
  9. Wise, S., Gardner, W., Sabelman, E., Valainis, E., Wong, Y., Glass, K., Drace, J. and Rosen, J., Evaluation of a fiber optic glove for semi-automated goniometric measurements. J. Rehab. Res. Devel., 27(4), 411-424, 1990 https://doi.org/10.1682/JRRD.1990.10.0411
  10. Yun, M. H., A Hand Posture Measurement System for the Analysis of Manual Tool Handling Tasks. Unpublished doctoral dissertation, Pennsylvania State University, Pennsylvania, 1994