• 제목/요약/키워드: hair surface

검색결과 148건 처리시간 0.023초

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

Experimental Results of New Ion Source for Performance Test

  • 김태성;정승호;장두희;이광원;인상열
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF

개량형 열회수 시스템의 열교환 성능 (Heat Exchange Performance of Improved Heat Recovery System)

  • 서원명;윤용철;권진근
    • 생물환경조절학회지
    • /
    • 제12권3호
    • /
    • pp.107-113
    • /
    • 2003
  • 본 연구에서는 온실의 온풍식 난방시스템 연통에 장착할 수 있는 폐열 회수기의 성능 개선을 목적으로 기 설계된 세 가지 열교환 장치와 기존의 장치에서 열교환 면적과 파이프의 두께 및 공기흐름 방향을 개량한 새 열교환 장치에 대해 열회수 성능을 실험적으로 비교 분석하였다. 그 결과 기존의 열 교환장치인 A형, B형 및 C형의 열회수 성능은 동일 송풍전입에서 각각 42.2%, 40.6% 및 54.4% 정도였으나 , 새로 개량된 D형은 69.2%로써 가장 현저히 높게 나타났다. 그러나 열회수용 공기의 흐름방향 변화에 따른 열회수 성능 개선효과 (A형 대비 B형)는 없는 것으로 나타나 적정 송풍기 용량이라면 직선형이 공기의 흐름방향 180${\circ}C$ 굴절시키는 헤어핀형보다 효과적인 것으로 판단된다. 결국 열회수 성능은 열회수 시스템의 열교환 면적과 열교환 파이프의 두께 및 풍속에 크게 좌우되는 것으로 나타났다. 따라서, 열교환 파이프의 내구성 등 을 고려하여 기능한 한 범위 내에서 열 교환면적을 증대시키거나 열교환 파이프의 두께를 앓게 하고 풍속을 증대시키는 것이 열회수 성능 개선효과와 직결됨을 알 수 있었다. 그리고 송풍기 용량이 필요이상으로 큰 경우, 소비전력이 많게 되는 등의 문제가 있기 때문에 적정용량 및 제품의 안정성을 고려하여 선택해야 할 것으로 판단되었다.

한국산(韓國産) 다수(茶樹)의 엽수병방제(葉銹病防除)에 관(關)한 연구(硏究) (Studies on the Prevention of Gleosporium Thea sinensis on the Tea Plant in Korea)

  • 김재생;최재식
    • 한국산림과학회지
    • /
    • 제76권4호
    • /
    • pp.357-360
    • /
    • 1987
  • 1) 다(茶)나무 엽수병(葉銹病)의 침입경로(侵入經路)는 다엽(茶葉)의 이면(裏面)에 있는 모용세포(毛茸細胞)임이 확인(確認)되었다. 2) 다(茶)나무중(中) 엽수병(葉銹病)이 가장 많이 발병(發病)되는 부위(部位)는 신초부위(新梢部位)로부터 1~5엽(葉) 범위(範圍)에 있는 유엽(幼葉) 부위(部位)였다. 3) 다(茶)나무잎에 포자(胞子)가 발아(發芽)되는 가장 적당(適當)한 온도(溫度)는 $25^{\circ}C{\sim}27^{\circ}C$일 때였으며, 수분(水分)이 12시간(時間) 젖어 있을 때였다. 4) 따라서 다(茶)나무 엽수병(葉銹病)의 예방(豫防) 방제(防除) 약제(藥劑)의 살포시기(撒布時期)는 이 시기(時期)에 살포(撒布)하는 것이 가장 효과적(效果的)일 것이며 또한 모초(毛茸)의 수량(數量)이 적은 다(茶)내무의 품종(品種)을 선발증식(選拔增植)하는 것이 가장 좋은 방법(方法)이라고 생각한다. 5) 분생포자(分生胞子)의 형성(形成)에 대(對)한 볼드액(液)의 조지효과(阻止效果)는 무살포구(無撒布區)에 비(比)하여 살포구(撒布區)에서 48.3%의 효과(效果)가 있었다. 6) 볼드액살포(液撒布)에 의(依)한 효과(效果)의 지속성(持續性)은 접종당시(接種當時)에는 28.5%였던 것이 접종(接種) 7일(日) 이후(以後)에는 22.0%로 감소(減少)되었다.

  • PDF

가토모델에서 배양 구강상피를 이용한 근-점막 피판의 형성에 관한 연구 (FABRICATION OF MYOMUCOSAL FLAP USING CULTURED ORAL EPITHELIUM IN RABBIT MODEL)

  • 신영민;정헌종;안강민;박희정;성미애;김성민;황순정;김명진;장정원;김성포;양은경;송계영;이종호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권3호
    • /
    • pp.226-237
    • /
    • 2005
  • Purpose : Extensive defect of oral and maxillofacial area is usually reconstructed with composite flap including skin paddle. However, if the defects are lined with only skin components, the mucosa's role in mastication and texture are not restored. Furthermore, stiffness and hair-growing prevent denture rehabilitation and good oral hygiene. This study was performed to overcome the disadvantages of composite soft tissue flaps including the skin and to make a model for myo-mucosal flaps. Materials and methods : Buccal mucosa sized $0.5\times1.0\;cm^2$ from New Zealand rabbit (around 1.5kg) was harvested and cultivated by the modification of Rheinwald and Green's keratinocyte culture method. Cultured mucosa was grafted on the fascia of latismus dorsi as form of mucosal sheet. After 7, 10, 14 days, the myomucosal flap was excised and evaluated under light microscope with H & E and immunohistochemical staining. As control group, harvested buccal mucosa from rabbit was transplanted to gracilis muscle(n=6). Results : From 7 days after prelamination, the basal layer of the grafted mucosa resembled that of normal mucosa. As control group, transplanted mucosa had original shape but there's slight inflammatory reaction. Prelaminated mucosa has 19.8$\pm$4.59 cell layers and some samples have more than 20 layers. The expression rate of PCNA was relatively strong (42.9%$\pm$14.1) at the basal layer of grafted mucosa and the laminin was found at the basal layer. On the contrary, prelaminated mucosa at 10 days showed moderate expression rate of PCNA(32.4%$\pm$4.62). We found the mucosal layer was somehow disappeared and there is strong inflammatory reaction. After 14 days prelamination, the grafted oral keratinocytes were almost disappeared and expression of PCNA was not observed. Conclusion : We can make 75 fold large mucosal($3850mm^2$) sheet from small samples of mucosa $(50mm^2)$. Epithelial sheet that grafted on the fascia of muscle underwent differentiation and proliferation. But after 10, 14 days, there was strong inflammatory reaction and the grafted mucosa was destroyed from surface layer. In rabbit model, transfer of fascio-mucosal flap should be done from 7 to 10 days after prelamination.

착유우의 톱밥발효우사 이용연구 제 1 보 : 낙농가의 톱밥발효우사 형태별 이용효과 비교 (Study on the Utilization of Sawdust Bedding Barn for Dairy Cows)

  • 권두중;권응기;기광석;이기종;한정대;정석찬;강승원;강상열;정형섭;장학주
    • 한국축산시설환경학회지
    • /
    • 제1권1호
    • /
    • pp.9-19
    • /
    • 1995
  • This study was carried out to investigate the effect of sawdust bedding barn on manure handing, management labour and physiological aspect of dairy cows, and then to establish the criteria on the optimum utilization method of sawdust bedding barn. 46 tie stall barns and 49 sawdust bedding barns were surveyed to cmopare the milk productivity between two different barns, and also 5 tie stall barns, 15 sawdust bedding barns and 1 rice hull bedding barn were selected to study the utilization situation of sawdust barn in Kyung-Ki province area. The major results obtained were as follows; 1. The roof material of sawdust barn were consisted of 66% vinyl house, 23% PVC light and 11% slate and galvanum coated tin. Most of the floor structure was earth ground with the rate of the approximately 82%. 2. The average occupied area of sawdust bed per cow was 15.2 $m^2$, depth that 30 cm and the utilization period was 12 months. 3. Milk Yield was significantly higher at sawdust barn than at tie stall barn(P<0.01). Bacterial and somatic cell count in raw milk were less at the sawdust barn than in tie stall barn. However, there was not significance difference between two barns. 4. The labour hour needed to cow management in the sawdust barn was approximately 48% of that of tie stall barn. 5. The temperature and moisture content measured in sawdust bed were closely affected by seasonal ambient temperature. The skin and hair of cow were much cleaner at the PVC light roofed sawdust barn than any other roof materials. 6. The additives used for improving of fermentation did not show any effect on temperature and moisture content in sawdust bed. When the ambient temperature was $30.4^{\circ}C$, the surface temperature of measured 1 cm above the sawdust bed was $12.2^{\circ}C$ lower and the temperature of 100 cm above the sawdust bed was $2.4^{\circ}C lower under shading net facility than that of vinyl roofed one.7. The hoof length of miking cow was 7.95 cm in tie stall and 9.19 cm in sawdust barn with high significance (P<0.01). And disease occurence such as mastitis and foot-rot tended to decrease in the sawdust barn. 8. The number of total bacteria and coliform bacteria were less in the sawdust bed compared with earth ground resting area. And a parasite strongyloides papillosus was detected but without any infected cow. 9. The nitrate($NO_3N$) content in non-roofed earth ground resting area and earth ground under the sawdust bed was likely to pollute the ground water. 10. In economic point of view, rice hull bedding barn was the cheapest among different systems. And in the sawdust bedding barn PVC light + slate roofed barn was most desirable, and vinyl roofed one the least.

  • PDF

글루코코티코이드에 의해서 유발된 개 피부의 장벽기능이상과 위축에 대한 지질 혼합물의 효과 (Effects of a Lipid Mixture on Glucocorticoid-induced Barrier Impairment and Epidermal Atrophy in the Canine Skin)

  • 진여원;안미지;구세광;박현정;이근우;오태호
    • 한국임상수의학회지
    • /
    • 제27권5호
    • /
    • pp.522-532
    • /
    • 2010
  • 본 연구의 목적은 정상적인 개의 피부에 스테로이드제 적용후 손상된 피부에 대한 지질 혼합물(콜레스테롤, 세라마이드, 자유지방산 함유)의 효과를 알아보는데 있다. 5두의 실험견을 대상으로 각각의 스테로이드제를 하루에 두 번씩 총 28일간 피부에 적용한 후, 지질 혼합물을 14일간 적용하였으며 실험기간 동안 표피경유수분손실(TEWL), 피부 수화도, 피부 산도를 측정하였고, 조직학적 분석을 실시하였다. 스테로이드 제제를 적용한 결과, 표피경유수분손실는 유의적으로 증가하였으며 28일 째 되는 날 가장 높은 수치를 나타냈다 (p < 0.01). 또한 피부 산도는 유의적으로 감소하여 28일 째 되는 날 가장 낮은 수치를 나타냈다 (p < 0.01). 피부 수화도는 3일 째 유의적으로 증가하였지만 그 후에는 점차 감소해서 기본 수치에 도달하였다. 조직학적 분석에서는 스테로이드 제제를 적용함에 따라서 각질층의 케라틴 감소, 진피 상부의 부종, 그리고 상피 및 각질층의 두께가 얇아진 것을 확인할 수 있었다. 게다가 대조군과 비교하였을 때 모낭의 숫자가 현저하게 감소하였고 상피와 모낭에서 caspase-3면역반응세포와 PARP면역반응세포의 숫자가 상당히 증가하였는데 (p < 0.01), 이것은 스테로이드 제제의 적용에 의해 피부의 위축현상이 나타났음을 의미한다. 하지만 지질 혼합물을 적용한 결과 이러한 피부위축현상이 상당히 억제되었고, 피부의 생리학적인 지표들이 기본 수치로 회복되었다. 이런 결과는 글루코코티코스테로이드 제제의 국소적인 적용이 피부장벽의 기능이상을 야기했다는 것을 의미하며, 지질 혼합물이 손상된 개의 피부를 치료하는데 효과적으로 사용될 수 있다는 가정을 입증한다. 그러므로 본 연구에서 사용된 지질 혼합물은 스테로이드 제제에 의해서 발생된 개의 피부 손상을 치료할 수 있을 것으로 기대된다.

북한강상류수계(北漢江上流水系)의 호수단지주변삼림(湖水団地周辺森林)의 풍경적시업(風景的施業)에 관(関)한 연구(硏究) (A Study on Forestation for Landscaping around the Lakes in the Upper Watersheds of North Han River)

  • 호을영
    • 한국산림과학회지
    • /
    • 제54권1호
    • /
    • pp.1-24
    • /
    • 1981
  • 강원도(江原道)는 관광자원(觀光資源)이 풍부(豊富)하며 태백산맥(太白山脈)을 중심(中心)으로한 산악관광권(山岳觀光圈), 동해안(東海岸)의 해안관광권(海岸觀光圈), 내륙(內陸)의 호수관광권(湖水觀光圈)으로 구분(區分)하고 있다. 동해(東海)의 절경(絶景)을 배경(背景)으로 설악산(雪岳山)과 오태산(五台山)의 국립공원(國立公園)이 있다. 그리고 치악산(雉岳山)의 도립공원(道立公園)이 있다. 북한강상류수계(北漢江上流水系)에는 발전용(發電用)댐건설(建設)로 만수(滿水)된 인공호수(人工湖水)가 연좌(連坐)하고 있어 호수관광권(湖水觀光圈)으로 각광(脚光)을 받고 있다. 본(本) 논문(論文)에서도 강원도행정수도(江原道行政首都)이며 호반(湖畔)의 도시(都市)인 춘천(春川)을 중심(中心)으로 북한강상류수계(北漢江上流水系)에 연좌(連坐)하고 있는 호수단지주변(湖水團地周邊)의 관광자원(觀光資源)을 배경(背景)으로 하여 삼림(森林)의 풍경적시업방안(風景的施業方案)을 모색하고 있다. 본(本) 호수단지(湖水團地)는 하류(下流)로부터 상류(上流)로 향(向)하여 의암호(衣岩湖), 소양호(昭陽湖), 춘천호(春川湖), 파려호(破慮湖)가 자리잡고 있으며 이들 4개(個) 호수(湖水)의 면적(面積)은 $140.4km^2$ 총저수량(總貯水量)은 4,155백만(百萬)$m^3$이다. 그리고 발전량(發電量)은 41만(萬)KW의 시설(施設)을 갖추고 있다. 이들 호수(湖水)를 위적(囲績)하고 있는 삼림면적(森林面積)은 $1,208km^2$에 달(達)한다. 삼림(森林)은 행정적(行政的)으로 시업림(施業林)$745km^2$와 시업제한림(施業制限林) $463km^2$로 구분(區分)하고 있으며 시업제한림(施業制限林)은 개발제한구역(開發制限區域)과 자연환경보전지구내(自然環境保全地區內)에 있는 삼림(森林)과 보안림(保安林)으로 되어 있다. 개발제한구역내(開發制限區域內)에 있는 삼림(森林)은 춘천(春川)을 중심(中心)으로 반경(半徑) 10km이내(以內)에 있는 의암호주변삼림(衣岩湖周邊森林)이며 그 면적(面積)은 $177km^2$이다. 자연환경보전지구내(自然環境保全地區內)의 삼림(森林)은 소양호연안(昭陽湖沿岸)에서 2km의 가시권내(可視圈內)에 설정(設定)되어 있으며 그 면적(面積)은 $165km^2$이다. 보안림(保安林)은 각(各) 호수연안삼림(湖水沿岸森林)에 설정(設定)되어 있으며 입지적여건상(立地的與件上) 수원함양림(水源函養林)이 주종(主宗)이며 그 면적(面積)은 $121km^2$이다. 본(本) 호수단지권내(湖水團地圈內)에는 많은 각승지(各勝地)와 유원지(遊園地) 그리고 문화재(文化財)와 유적지(遺蹟地)가 있어 호수(湖水)와 삼림(森林)과 같이 귀중(貴重)한 관광자원(觀光資源)으로 부상(浮上)되고 있다. 본(本) 호수단지주변삼림(湖水團地周邊森林)은 I~II영급(令級)의 유령림(幼令林)이 전체삼림(全體森林)의 70%를 점(點)하고 있어 ha당(當)축적(蓄積)은 $15m^3$로 탐약(貪弱)하다. 침엽수림(針葉樹林), 활엽수림(濶葉樹林), 혼효림(混淆林)의 면적비율(面積比率)은 35:37:28로 활엽수림(濶葉樹林)의 면적(面積)이 약천(若千) 우위(優位)를 점(點)하고 있다. 소유형태(所有形態)는 국유림(國有林), 도유림(道有林), 군유림(郡有林), 사유림(私有林)으로 되어 있으며 그 비율(比率)은 36:14:5:45로 사유림(私有林)이 약절반(約切半)을 점(點)하고 다음이 국유림(國有林), 도유림(道有林), 군유림(郡有林)의 순(順)으로 되어 있다. 지질(地質)은 모암(母岩)이 화강암(花岡岩) 또는 편마암계(片麻岩系)로서 풍화성(風化性)이 강(强)하고 표토층(表土層)이 척박(瘠薄)함으로 임지비배문제(林地肥培問題)를 염두(念頭)에 두어야 한다. 이상(以上)의 여건(與件)을 토태(土台)로 삼림(森林)의 풍경적시업(風景的施業)의 기본방향(基本方向)을 제시(提示)하면 다음과 같다. 1) 현재(現在) 임분(林分)은 유령림(幼令林)이 대부분(大部分)이고 임지(林地)가 척박(瘠薄)함으로 임지비배(林地肥培)와 임목무육(林木撫育)에 주력(注力)하여 장령림(壯令林)의 경지(境地)로 유도(誘導)할 것. 2) 황폐성미립목지(荒廢性未立木地)와 임간라지(林間裸地)에는 속성수(速成樹)인 리기다소나무, 오리나무 등(等)은 식재(植栽)하여 조속(早速)히 피복녹화(被覆綠化) 시킬 것. 3)계곡부(溪谷部)로서 습윤(濕潤)하고 지미(地味)가 비교적(比較的) 양호(良好)한 라지(裸地)에는 잣나무, 낙엽송, 전나무 등(等)을 식재(植栽)하여 교림(喬林)으로 육성(育成)할 것. 4) 현재(現在) 사유림(私有林)의 침엽수림(針葉樹林)은 적송(赤松)이 주체(主體)가 되어 있다. 적송(赤松)은 양수(陽樹)로서 수원함양기능(水源函養機能)이 적은 위에 현재(現在) 솔잎혹파리의 피해(被害)를 입고 있어 수종갱신(樹種更新)이 불가피(不可避)하다. 그러므로 계곡부(溪谷部)부터 잣나무, 전나무, 가문비나무, 솔송나무 등(等)을 식재(植栽)하에 점차(漸次) 음성(陰性) 침엽수림(針葉樹林)으로 대체(代替)케 할 것. 5) 현재(現在) 활엽수림(濶葉樹林)은 재질면(材質面)에 있어서나 풍치면(風致面)에 있어서 가치성(價値性)이 저렬(低劣)한 잡목(雜木), 관목(灌木) 등(等)이 많으므로 점차(漸次) 이를 제거(除去)하고 참나무, 단풍나무, 물푸레나무, 자작나무, 가래나무등(等)으로 대체(代替)케 할 것. 6) 주변(周邊) 산록부(山麓部)에는 벚나무, 수양버들, 은사시나무, 후박나무, 은행나무, 향나무, 밤나무, 살구나무, 등(等)의 관상수(觀賞樹)를 조화(調和)있게 식재(殖財)할 것. 7) 활엽수림(濶葉樹林)의 갱신(更新)을 중림형(中林型)으로 유도(誘導)하여 상하이단(上下二段)의 임관형(林冠型)의 미(美)를 조성(造成)하는 구역(區域)과 왜림형(矮林型)을 조리(調利)있게 배열(配列)하는 방안(方案)을 모색할 것. 8) 침엽수림(針葉樹林)의 갱신(更新)은 택벌작업(擇伐作業) 또는 산벌작업(傘伐作業)에 의(依)해 풍치보전(風致保全)을 기(期)할 것. 9) 혼효림(混淆林)은 상목(上木)은 침엽수(針葉樹)를 하목(下木)은 활엽수(濶葉樹)로 하는 중림형(中林型)의 풍치(風致)를 보존(保存)토록 할 것. 요(要)컨대 호수(湖水)의 우아(優雅)한 여성미(女性美)와 삼림(森林)의 호장웅대(豪壯雄大)한 남성미(男性美)가 조화(調和)되어 자연(自然)의 심오(深奧)한 신비성(神秘性)을 간직하는데 역점(力點)을 두어 궁극적(窮極的)으로는 삼림(森林)을 배경(背景)으로한 호수관광권(湖水觀光圈)의 면모(面貌)를 갖추는데 초점(焦點)을 둘 것이다.

  • PDF