• Title/Summary/Keyword: gymnasium

Search Result 92, Processing Time 0.029 seconds

An Analysis on the Relationship of Architectural Features and Composition Elements for Structure Planning in School Gymnasium (학교체육관의 구조계획을 위한 구조시스템 구성요소의 변화와 건축특성의 영향분석)

  • Lee, Juna
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.26 no.5
    • /
    • pp.25-36
    • /
    • 2019
  • School gymnasium is a multi-purpose large space building for various events and physical education activities, and is a facility that requires an approach to the desirable structural design, besides mechanical problems of structure against loads. For the integrated structure design concerning the architectural features, the major considerations of gymnasium planning that are the internal and external shape of the gymnasium, the space scale with structure members, the structural efficiency by members weight reduction and openness of the gymnasium space will have to take into account in the structural planning. From this point of view, the several cases of the school gymnasium were investigated and the parametric analyses were performed to the models using the various structural system. The parameters were the composition elements of structure system that are profile of structure, rigidity of member, connection and anchorage and stability. At the result, It was presented that the profile of structure member was the most influential factor to structural efficiency and the effect of the form and space of gymnasium. Also the design informations of structure design having the various feature of form and space were presented for the initial gymnasium planning.

Architectural Acoustic Performance Renovation of the Large Gymnasium using Acoustic Simulation (음향시뮬레이션을 이용한 대형 실내체육관의 건축음향성능 개선에 관한 연구)

  • Yun, Jae-Hyun;Kim, Jae-Soo
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.41-48
    • /
    • 2008
  • In this study, an analysis is carried out on the acoustic design for an indoor gymnasium scheduled to be built at Buan County, Chonbuk Province. By way of background, the study examines the case of a large-scale indoor gymnasium that has been constructed in the local area of Hangan-myeon. There are many examples whereby this gymnasium could be used not only as a sporting facility for the residents, but also as a multipurpose space for public performances such as leisure activities, lectures, assembling activities, theatre and concerts etc. In order to maximize the functional utilization of such an indoor gymnasium, it is important to simultaneously verify the acoustic capabilities of the space in terms of Definition of both Voice and Music. However, as a large-scaled athletic facility, the building was designed with a high ceiling-height to accommodate its functional characteristics. The space forms a Sound Focus whereby the sound is concentrated at a specific part, and because the vibration of sound is too loud due to its broad volume, acoustic defects arise such as a significant number of Echoes. Using this gymnasium as a precedent, this study proposes an acoustic design based on the drawings of the indoor gymnasium that is scheduled to be built at B County, Chonbuk Province. The gymnasium is equipped with an optimized acoustic condition passing through the Acoustic Simulation Phase. From the results of an Acoustic Simulation, we can design an indoor gymnasium that is equipped with a considerably satisfying and improved acoustic performance compared with the building before it was reformed. It is also considered that the use of such materials can fundamentally reduce construction costs and can improve acoustic performance, at the planning and design stages for similar sporting facilities in the future.

A Study on the Improvement of Architectural Acoustic Performance in the Large Gymnasium (대형(大形) 실내체육관(室內體育館)의 건축음향성능(建築音響性能) 개선(改選)에 관(關)한 연구(硏究))

  • Yun, Jae-Hyun;Kim, Jae-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.421-426
    • /
    • 2008
  • In case of the large-scaled indoor gymnasium that has been constructed in the local area, there are many instances for the use as multipurpose space where the public performances are possible such as leisure activity, lecture, assembling activity, drama, concert and so on for the resident together with the purpose of sporting facility. In order for utilization to the maximum of the function of such indoor gymnasium, the acoustic capabilities concerned with Definition of both Voice and Music are simultaneously required. However, in case of the large-scaled athletic facility, since it was designed with high ceiling-height in view of its characteristics, it forms a Sound Focus and then the sound is concentrating to the specific part, and because the vibration of sound is too loud due to its broad volume, the acoustic defects such as many Echoes are arising. On such viewpoint, based on the drawing of the indoor gymnasium that is scheduled to be built at B County, Chonbuk Province, this Study has proposed such indoor gymnasium equipped with the optimized acoustic condition passing through Acoustic Simulation Phase. As the result of Acoustic Simulation, we could design the indoor gymnasium that equipped with really satisfying acoustic performance 'after' reformation compared with 'before' reformation, and it is considering that such material could be utilized as the fundamental material that brings a curtailment effect of the construction cost and also enables us to improve the acoustic performance, at the stage of planning and designing for the similar sporting facility in the future.

  • PDF

A Study on the Subjective Response Evaluations of Acoustics Performance of the Large Gymnasium (대형 실내체육관 음향성능의 주관적 반응 평가에 관한 연구)

  • Yun, Hee-Kyoung;Kim, Jae-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.53-58
    • /
    • 2003
  • Now days, as the consideration of sound environment is getting important, method of physical measurement such as reverberation time and sound pressure level becomes common. However, such method cant include subjective sensation such as personal emotion and feeling, evaluation. So there is a limitation to make the most optimized sound environment. Therefore, in the present experiment, I improve big indoor gymnasium that has sound defect because of too long reverberation time. After that, I conduct the auditory sense evaluation of human psychological response. From the experiment, I will make research into sound satisfaction rate about the subject space and response of each item. As well as, I will present the result as basic database of sound environment improvement experiment of indoor gymnasium.

  • PDF

The Relationship between Gymnasium Selection and Training Adherence of Security Martial Arts Trainees (경호무도 수련생의 도장선택과 수련지속의 관계)

  • Song, Gyu-Geun;Lee, Ki-Se;Min, Jae-Ki
    • Korean Security Journal
    • /
    • no.27
    • /
    • pp.107-128
    • /
    • 2011
  • The purpose of this study was to determine the relationship between gymnasium selection and training adherence of security martial arts trainees. To this aim, this study selected 8 gymnasiums in Gyounggi and Incheon province and sampled 220 people above the fourth grade in elementary school. Out of these, 14 cases were dropped due to insufficient answers or incomplete answers, and 206 qualified cases were finally adopted for this study. Data were analyzed using exploratory factor analysis, reliability analysis and frequency analysis, MANOVA, correlation analysis and multiple regression analysis with SPSS 18.0. The results of this study were as follows. First, there were significant differences in gymnasium selection factors(instructor background, training program, public relations) depending upon the trainee's sex. Second, there were significant differences in gymnasium selection factors(training program, main others, public relations) depending upon the trainee's school grade. Third, there were no significant differences in training adherence factors depending upon the trainee's sex and school grade. Fourth, there were positive correlations between instructor background, training program and public relations-factors among gymnasium selection and management program, external and social relations-factors among training adherence. Fifth, the partial sub-factors of gymnasium selection have influenced training adherence. Consequently, security martial arts managers and instructors need to establish marketing strategies suitable for sex and school grade to recruit new security martial arts trainees. It may be considered that security martial arts instructors should construct the differentiated management system for trainees and the specialized training program for lasting training of new or existing security martial arts trainees.

  • PDF

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.4
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

Survey on the Gymnasium and Multi -use facilities of the Schools in Chungbuk Area (충북 지역 학교 체육관 겸 강당 시설에 대한 실태조사 및 활용방안)

  • Choi, Younggi;Cho, Seongwoon;Han, Kyuyoung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.2 no.2
    • /
    • pp.35-46
    • /
    • 2000
  • The school space has been recognized only as the space for the education and training of children. However, since most of the school is located in the center of the regional community, the school space must be not only the space of the education and training of children, but the space for the regional inhabitants' community in the future. The present study is aiming to investigate the architectural background and to utilize the multi-use facilities of schools which are taken a role of facilities of gymnasium and auditorium.

  • PDF

Analysis of the Room Acoustic Characteristics depending on the Sound Sources for a Multi-purpose Gymnasium finished with Absorbers on Walls and Ceiling (벽 및 천장이 흡음재로 마감된 다목적 체육관에서 음원종류에 따른 실내음향특성의 분석)

  • Park, Hyeon-Ku;Jeon, Ji-Hyun;Song, Hyuk;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.2 no.1
    • /
    • pp.41-48
    • /
    • 2002
  • This study aims to investigate and evaluate the room acoustic designs of a multi purpose gymnasiums which do not use adjustable treatments in order to change the acoustical characteristics. Considering the main uses of gymnasium and auditorium, experiments were carried out using both nondirectional speakers on the stage and loudspeaker installed on the ceiling. The result from the study are as follows; Measured RT under unoccupied condition was a little longer than the expected value, therefore, in the case of occupied condition RT would be close to the optimum value. However, parameters that evaluate intelligibility and speech transmission property appeared to be low and have large differences depending on the measuring points, therefore, more effective sound reflecting surfaces and sound reinforcement systems should be considered.

A Study on the Room Acoustic Characteristics according to the Layout System of Speakers in the School Gymnasium (학교체육관에서 스피커 배치방식에 따른 실내음향특성에 관한 연구)

  • Lee, Ju-Yeob;Kim, Jong-Bin;Park, Hyeon-Ku;Choi, Hyung-Wook;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.462-467
    • /
    • 2000
  • The aim of this study is to provide fundamental data for acoustic design by analyzing the room acoustic characteristics according to the PA system used in the school gymnasium. The measurements were carried out accordance with the ISO 3382. The sources used in this study were four types; omni-directional, centralized, distribution, the combination of centralized and distribution sound source system. Omni-directional system is recommended by ISO for the acoustic test and the others are installed on the wall, column and ceiling in the school gymnasium for sound reinforcement.

  • PDF

Combustible Gas and Visible Distance by Sprinkler Head for Safety of Gymnasium Workers

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.232-244
    • /
    • 2021
  • This study analyzed the changes in carbon monoxide, carbon dioxide, oxygen and visual distance by presence of sprinkler heads and their types in the event of a fire in an indoor gymnasium. Based on carbon monoxide and visual distance that affects human bodies enormously, first, if there is no sprinkler head, carbon monoxide will reach 0.4% within five seconds and visual distance rapidly shrank within five seconds. Seconds, in the event of standard sprinkler heads, carbon monoxide gradually increased from 30 seconds onwards and visual distance rapidly shrank after five seconds. Second, Third, if there are special sprinkler heads, carbon monoxide fluctuated after opening the head and visual distance became 5m or below from 15 seconds. Finally, in the event of early response sprinkler heads, carbon monoxide fluctuated up and down at 3 seconds due to falling water drops. Visual distance shrank up to 5m or below at 6 seconds. In the future, time for operation of each sprinkler head shall be analyzed.