• 제목/요약/키워드: guideline value

검색결과 463건 처리시간 0.026초

열교부위를 고려한 커튼월 사무소 건물의 열성능 해석에 관한 연구 (A Study on the Thermal Performance Analysis of Curtain Wall Office Building Considering the Thermal Bridges)

  • 신우철;김승철;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.95-100
    • /
    • 2011
  • Currently, office buildings in Korea tend to adopt as their outer wall the curtain wall structure which can be easily constructed and has beautiful external appearance as well. However, the problem is that the curtain wall structure does not have a uniform composition unlike the wall of existing reinforced concrete structures and has a frame made of metal with high heat conduction. Therefore, it is expected that the structure will be highly influenced by the thermal bridge. Thereupon, this study analyzes how to set up the composition of the wall system and heat transmission rate in consideration of the thermal characteristics of the curtain wall structure and applies it in practice by simulation in order to propose a guideline for the energy simulation method of the curtain wall structure and analyze its differences from existing simulation methods.

NATM 산악터널의 숏크리트 투입율에 관한 연구 (A study on Actual Quantity of Shotcrete Sprayed in a NATM tunnel)

  • 이철주;김성윤;김동건;유남재
    • 산업기술연구
    • /
    • 제29권B호
    • /
    • pp.57-64
    • /
    • 2009
  • This study has analysed actual overbreak, shotcrete rebound and the ratio between the actual quantity of shotcrete to designed shotcrete measured during a NATM tunnel construction. The measured shotcrete rebound was about 7.2% in average which was about half the allowable rebound (15%), showing shotcrete spraying was performed well. Based on the measurement of excavated tunnel shape, average overbreak was about 28.5cm after tunnel excavation by drill and blasting method. This was about 260% of allowable overbreak. In addition, due to the rebound and overbreak actual amount of shotcrete used in the tunnelling work was about 116.5 % of the designed value. According to the field measurement the ratio of actual shotcrete to designed value showed some relation with standard support pattern, but the size of overbreak did not show the correlation with standard support pattern. Hence current design specifications stating the size of overbreak based entirely on standard support pattern should perhaps be reestablished. The insight into the design guideline regarding overbreak and shotcrete.

  • PDF

Actiwatch 를 이용한 철도소음에 의한 수면방해의 정량적 평가 (Assessment of Sleep Disturbance on Night-time Instantaneous Railway Noise by using Actiwatch)

  • 홍지영;김재환;임창우;김규태;성동원;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.759-763
    • /
    • 2006
  • The World Health Organization(WHO) has recommended population of sleep disturbance as one of the environmental health indicators. But the percentage of respondents who felt highly sleep disturbed, that is, %HSD can???thave application to sleep disturbance from instantaneous noise. Therefore, this study has been carried out to present the technique for assessing sleep disturbance on instantaneous noise quantitatively. The study of sleep disturbance on night time instantaneous railway noise has been undertaken. Noise monitor has been in operation from 22 hours to 7 hours during 6 nights at 12 locations. To assess instantaneous noise induced sleep disturbance, it was decided to measure body movement by actiwatch. %motility was used as indicators of sleep disturbance. %motility is the expected value of probability of motility value during 7 epochs (105s) of any noise event. The measures of instantaneous motility have been related to measures of instantaneous railway noise events. The relationship shows that %motility is a good predictor for assessing sleep disturbance and Korean is more sensitive to noise than European although the railway noise have been considered in this study. This study can be extended to assessing long-term sleep disturbance and give a guideline far policy decision.

  • PDF

대퇴절단환자의 고관절 등속성근력비율에 관한 연구 (A Study on Isokinetic Strength Ratios of Hip joints in Above-knee Amputees)

  • 송창호;이완희
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.74-82
    • /
    • 2003
  • The purpose of this study is to provide guideline of muscle strengthening exercise for preparing ambulation by presenting suitable ratio of muscle power of agonist & antagonist, and that of concentric & eccentric contraction on behalf of amputee's normal ambulation training and it's strenthening as well. 7 Subjects who have femur amputee for experimental group were able to ambulate naturally without inconvenience and 20 adult subjects of comparison group for comparison were considered to be free from disturbance of ambulation. The method of study was to measure the muscle power of hip pint, was to figure out the ratio of agonist & antagonist, concentric contraction & eccentric contraction, and was to find out mean and standard deviation of each measurement. Every numerical value of comparison was tested by Mann-whitney and comparison group's comparison between left & right value was done with t-test. Results are as followings : 1) Extension force was stronger than flexor force and had no remarkable difference(p<0.05) 2) For normal adults, adduction farce was stronger than abduction force and for amputees, abduction force was stronger while adduction force was the same as the normal without showing remarkable difference(p<0.05) According the result above, I make an assumption that maintaining a proper ratio of muscle power on strengthening exercise for amputee's ambulation training & rehabilitation and finally bring out an improvement of transfer and ambulation.

  • PDF

1차원 지반응답해석을 통한 사면의 증폭특성 규명 (Estimation of amplification of slope via 1-D site response analysis)

  • 윤세웅;박두희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.620-625
    • /
    • 2009
  • The seismic slope stability is most often evaluated by the pseudo-static limit analysis, in which the earthquake loading is simplified as static inertial loads acting in horizontal and/or vertical directions. The transient loading is represented by constant acceleration via the pseudostatic coefficients. The result of a pseudostatic analysis is governed by the selection of the value of the pseudostatic coefficient. However, selection of the value is very difficult and often done in an ad hoc manner without a sound physical reasoning. In addition, the maximum acceleration is commonly estimated from the design guideline, which cannot accurately estimate the dynamic response of a slope. There is a need to perform a 2D dynamic analysis to properly define the dynamic response characteristics. This paper develops the modified one-dimensional seismic site response analysis. The modified site response analysis adjusts the density of the layers to simulate the change in mass and weight of the layers of the slope with depth. Multiple analyses are performed at various locations within the slope to estimate the change in seismic response of the slope. The calculated peak acceleration profiles with depth from the developed procedure are compared to those by the two-dimensional analyses. Comparisons show that the two methods result in remarkable match.

  • PDF

유한고장 NHPP 어랑분포의 형상모수 변화에 따른 소프트웨어 신뢰성 모형의 속성 분석에 관한 연구 (A Study on the Property Analysis of Software Reliability Model with Shape Parameter Change of Finite Fault NHPP Erlang Distribution)

  • 민경일
    • Journal of Information Technology Applications and Management
    • /
    • 제25권4호
    • /
    • pp.115-122
    • /
    • 2018
  • Software reliability has the greatest impact on computer system reliability and software quality. For this software reliability analysis, In this study, we compare and analyze the trends of the properties affecting the reliability according to the shape parameters of Erlang distribution based on the finite fault NHPP. Software failure time data were used to analyze software failure phenomena, the maximum likelihood estimation method was used for parameter estimation. As a result, it can be seen that the intensity function is effective because it shows a tendency to decrease with time when the shape parameters a = 1 and a = 3. However, the pattern of the mean value function showed an underestimation pattern for the true values when the shape parameters a = 1 and a = 2, but it was found to be more efficient when a = 3 because the error width from the true value was small. Also, in the reliability evaluation of the future mission time, the stable and high trend was shown when the shape parameters a = 1 and a = 3, but on the contrary, when a = 2, the reliability decreased with the failure time. Through this study, the property of finite fault NHPP Erlang model according to the change of shape parameter without existing research case was newly analyzed, and new research information that software developers can use as basic guideline was presented.

Sample size determination for conducting a pilot study to assess reliability of a questionnaire

  • Mohamad Adam Bujang;Evi Diana Omar;Diana Hui Ping Foo ;Yoon Khee Hon
    • Restorative Dentistry and Endodontics
    • /
    • 제49권1호
    • /
    • pp.3.1-3.8
    • /
    • 2024
  • This article is a narrative review that discusses the recommended sample size requirements to design a pilot study to assess the reliability of a questionnaire. A list of various sample size tables that are based on the kappa agreement test, intra-class correlation test and Cronbach's alpha test has been compiled together. For all calculations, type I error (alpha) was set at a maximum value of 0.05, and power was set at a minimum value of 80.0%. For the kappa agreement test, intra-class correlation test, and Cronbach's alpha test, the recommended minimum sample size requirement based on the ideal effect sizes shall be at least 15, 22, and 24 subjects respectively. By making allowances for a non-response rate of 20.0%, a minimum sample size of 30 respondents will be sufficient to assess the reliability of the questionnaire. The clear guideline of minimum sample size requirement for the pilot study to assess the reliability of a questionnaire is discussed and this will ease researchers in preparation for the pilot study. This study provides justification for a minimum requirement of a sample size of 30 respondents specifically to test the reliability of a questionnaire.

웹기반 지능형 기술가치평가 시스템에 관한 연구 (A Study on Web-based Technology Valuation System)

  • 성태응;전승표;김상국;박현우
    • 지능정보연구
    • /
    • 제23권1호
    • /
    • pp.23-46
    • /
    • 2017
  • 2000년대 이전부터 북미 유럽의 선진국을 중심으로 특정 기업이나 사업(프로젝트)에 관한 가치를 평가하는 사례는 있어 왔으나, 개별 기술(특허)의 경제적 가치를 산정하는 체계나 방법론은 국내를 중심으로 최근 들어 활성화되어 왔다. 이러한 기술가치평가 분야는 기술이전(거래), 현물출자, 사업타당성 분석, 투자유치, 세무/소송 등의 다양한 용도로 활용되고 있다. 물론 기술보증기금의 KTRS, 발명진흥회의 SMART 3.1과 같이, 평가대상기술에 대한 기술력(등급) 평가 혹은 특허등급평가를 정성적으로 수행하는 온라인 시스템은 존재해 왔으나, 대상기술의 정량적인 가치금액까지 산출해 주는 웹기반 지능형 기술가치평가 시스템은 한국과학기술정보연구원(KISTI)에 의해 유일하게 개발 및 공식 오픈되어 확산 활용되고 있다. 본 고에서는 KISTI에서 개발 운영중인 웹기반 'STAR-Value' 시스템을 중심으로, 탑재된 방법론 및 평가모델의 유형, 이를 지원하는 참조정보 및 데이터베이스(D/B)가 어떻게 연계 활용되는지를 소개한다. 특히 미래에 발생할 경제적 수익을 추정하여 현재가치화하는 소득접근법 기반의 대표 모델인 현금흐름할인(DCF) 모델과 특정 로열티율을 기반으로 로열티수입료의 현재가치를 기술료 대가로 산정하는 로열티절감모델을 포함한 6개 모델, 그리고 관련 지원정보(기술수명, 기업(업종)재무정보, 할인율, 산업기술요소 등)의 데이터 기반 연계 방식에 대해 살펴본다. STAR-Value 시스템은 평가대상기술에 대한 국제특허분류(IPC) 혹은 한국표준산업분류(KSIC) 등의 분류 정보로부터 기술순환주기(TCT) 지수, 유사업종(혹은 유사기업)의 매출액 성장률 및 수익성 데이터, 업종별 가중평균자본비용(WACC) 및 산업기술요소 지수 등 메타데이터값을 자동적으로 불러오고 여기에 조정요인을 반영하여 기술가치의 산출결과가 높은 신뢰성 및 객관성을 가지도록 한다. 나아가 대상기술의 잠재적 시장규모와 해당 사업화주체의 시장점유율에 대한 정보까지 보유 재무데이터 기반으로 참조값을 제시하거나 기존에 완료된 평가사례 축적 기반으로 업종별 유사 기술의 가치범위값을 제시해 준다면, 본 시스템이 보다 지능형으로 지원 모듈을 연계 활용하고 실시간으로 손쉽게 고(高)정확도의 기술가치범위를 제시해 줄 수 있을 것으로 기대된다. 본 고에서는 웹기반 STAR-Value 시스템이 참조데이터 기반으로 지능형 연계를 수행하도록 해주는 모형선택 가이드라인 지원기능, 기술가치범위 추론 지원기능, 유사기업 선정 기반의 시장점유율 산정 지원기능의 내부 로직 구성을 설명한다. 상기 지원기능을 통해 비전문가(또는 초보자) 수준에서 최적의 평가모형 선택, 기술가치 범위 추론, 유사기업 선택 및 시장점유율 산정에 대한 정보지원이 데이터 사이언스 및 기계학습 기반으로 수행될 수 있다. 본 연구는 기술가치평가 분야의 이론적 타당성을 평가실무에서 활용할 수 있는 평가모델 및 지원정보를 실제 탑재한 웹기반 시스템의 소개에 의미가 있으며, 추가적으로 보다 객관적이고 손쉬운 지능형 지원시스템의 활용성을 높임으로써, 앞으로 기술사업화의 제 분야에서 다양하게 활용할 수 있을 것으로 기대된다.

직접 간호활동 분석을 기초로 한 환자분류체계의 기준 설정을 위한 연구 (A Study for Formulating Criteria of Patient Classification System Based OR the Analysis of Direct Nursing Activities)

  • 김조자;박지원
    • 대한간호학회지
    • /
    • 제17권1호
    • /
    • pp.9-23
    • /
    • 1987
  • Nursing service, as the largest user of labor resources, has become concerned about appropriate allocation of staffing resources. Therefore, this project was designed to measure quantitatively the direct nursing care provided to patients and to develop a new patient classification system based on the direct nursing care activities. The initial step in the development of the classification instrument was to identify the content of direct nursing activities. The frequency with which these activities were carried out, the total time spent in carrying them out and the average time for one performance of each of the nursing activities was calculated. The next step was to select the items for the classification instrument taking into account these direct nursing activities. A list of 40 items was prepared. These items were then classified into 8 major categories: personal hygiene, moving & exercise, nutrition & elimination, observation, medication, treatment, collecting specimens and other care activities for severity ill patients. Each item was assigned a value unit based on the average time required by the nursing staff to complete the specific item. The third step was to determine the practicality of the items and value units, so an attempt was made to establish content validity for these items and units by obtaing a consensus from 8 head nurses, representing eight different departments. The 4th step was to conducted a pilot study to establish the score range for the classification boundaries. For this purpose an instrument was designed using the list of items and value units and a prepared classification criteria as a guideline to validate the patient classification. A judgment group consisting of 52 supervisory nurses and head nurses were asked to select the proper patient to fit each classification criteria and to fill out the instrument for each patient. The total value unit and the frequency for each classification group was calculated. According to the frequency distribution, the score range for the classification group was determined as follows : 0~15 for groupI, 16~30 for group II, 31~50 for group III, and above 51 for group IV. Finally a patient classification form was developed.

  • PDF

중재적 방사선 시술 시 환자선량에 대한 참고 준위 비교 (Reference levels for patient Radiation Dose in interventional radiological procedures)

  • 박혁;김용완;전주섭
    • 한국방사선학회논문지
    • /
    • 제6권1호
    • /
    • pp.11-17
    • /
    • 2012
  • 중재적 방사선 시술 시 환자의 피폭선량을 시술별로 분류하여 측정 및 평가하여 안전관리 자료로 활용하고자 하였다. 검사는 시술별(TACE, EVAR, Iliac stent, Lower Limb, BAE, Embolization, PTBD, PTGBD, Abscess, Nephrostomy)로 투시시간, 면적선량, 영상획득이미지 수를 측정하였다. 시술별 분석결과 비혈관계 검사에서 전반적으로 낮은 값을 보였으며, 혈관계 검사에서는 IVC filter를 제외한 모든 검사에서 높은 값을 나타냈다. 투시시간은 EVAR가 24m30s로 가장 높았고, 면적선량 또한 EVAR가 236 $Gy/cm^2$로 가장 높았다. 면적선량률은 TACE가 22.8 $Gy/cm^2$로 높게 나타났다. 이 결과를 토대로 중재적 방사선시술시 환자피폭선량에 대한 기준선량을 제시하고자 한다.