DOI QR코드

DOI QR Code

Reference levels for patient Radiation Dose in interventional radiological procedures

중재적 방사선 시술 시 환자선량에 대한 참고 준위 비교

  • Park, Hyeok (Department of Diagnostic Radiology, Chonnam National University Hospital) ;
  • Kim, Yong-Wan (Department of Diagnostic Radiology, Chonnam National University Hospital) ;
  • Jeon, Ju-Seob (Department of Diagnostic Radiology, Chonnam National University Hospital)
  • 박혁 (전남대학교병원 영상의학과) ;
  • 김용완 (전남대학교병원 영상의학과) ;
  • 전주섭 (전남대학교병원 영상의학과)
  • Received : 2011.09.30
  • Accepted : 2012.02.21
  • Published : 2012.02.28

Abstract

The purpose of this study is to measure and evaluate radiation dose on patients in interventional radiological(IVR) procedures classified by each procedure, and aid as data for safety management. Fluroscopy time(F-time), dose area product(DAP) and number of acquired images from each kind of procedure was checked. Non-vascular procedures showed low value, and vascular procedure showed high value in all procedures except in IVC filter. F-time was longest in EVAR, which showed also the highest DAP value of all procedures. DAP-rate showed high value in TACE. By this result, we attempt to establish standard guideline of radiation dose on patients in IVR procedure.

중재적 방사선 시술 시 환자의 피폭선량을 시술별로 분류하여 측정 및 평가하여 안전관리 자료로 활용하고자 하였다. 검사는 시술별(TACE, EVAR, Iliac stent, Lower Limb, BAE, Embolization, PTBD, PTGBD, Abscess, Nephrostomy)로 투시시간, 면적선량, 영상획득이미지 수를 측정하였다. 시술별 분석결과 비혈관계 검사에서 전반적으로 낮은 값을 보였으며, 혈관계 검사에서는 IVC filter를 제외한 모든 검사에서 높은 값을 나타냈다. 투시시간은 EVAR가 24m30s로 가장 높았고, 면적선량 또한 EVAR가 236 $Gy/cm^2$로 가장 높았다. 면적선량률은 TACE가 22.8 $Gy/cm^2$로 높게 나타났다. 이 결과를 토대로 중재적 방사선시술시 환자피폭선량에 대한 기준선량을 제시하고자 한다.

Keywords

References

  1. UNSCEAR, "Effect and Risk of Ionizing Radiation", UNSCEAR Repf, 1998.
  2. Bushong, S. C., "Radiologic Science for Technologists: Physics, Biology, and Protection (6th ed.), 1993.
  3. 도영수, 김현범, 박흥석, 정환훈, 김창원, 강병철, 박광보, 홍광표, 강병삼, 고인범, 한영이, 하명진, "혈관조영X-선장치의 안전관리 기준 개발, 식품의약품안전청 용역연구개발사업, 2003.
  4. 식품의약품안전청, " 환자선량 측정 가이드라인", 방사선안전관리시리즈 No.14, 2007.
  5. 이광용, "진단방사선분야에서의 환자선량 평가 및 환자 방어", 대한인터벤션영상기술학회, pp.16-21, 2003.
  6. 정진욱, "중재적방사선분야에서의 환자피폭선량 평가", 식품의약품안전청연구보고서 제 11권, 2007.
  7. Bryk SG , Censullo ML , Wagner LK , Rossman LL , Cohen AM . Endovascular and interventional procedures in obese patients:a review of procedural technique modifi cations and radiation management . J Vasc Interv Radiol Vol. 17, No. 1, pp.27-33, 2006. https://doi.org/10.1097/01.RVI.0000186953.44651.19
  8. 김혁주,이정은,이현구,김병우, 정진백, 양현규,임천일, 차선희, 손혜경, 김지혜, "의료 방사선 안전 가이드라인 마련을 위한 연구", 식품의약품안전청 용역연구개발사업, 2010
  9. Gray, Archer Br, and P.F.Butler, "Reference values for diagnostic radiology : application and impact," Radiology, Vol.235, pp.354-358, 2005. https://doi.org/10.1148/radiol.2352020016
  10. http://sizekorea.kats.go.kr
  11. 한양대학교 방사선안전신기술연구센터, "중재적 의료절차에서 방사선 상해의 예방", 국제방사선방호위원회 간행물 85, http://www.icrp.org/docs/P085_Korean.pdf
  12. Wagner, L.K., Archer, B.R., "Minimising Risks from Fluoroscopic X Rays. A Credentialing Program. 2nd Edition. R.M. Partnership, 3 EWedgemere Circle, The Woodlands, TX, USA, 1998.
  13. Wagner, L.K., Archer, B.R., "Management of patient skin dose in fluoroscopically guided interventional procedures. J. Vasc. Intervent. Radiol. Vol. 11, pp.25-34, 2000. https://doi.org/10.1016/S1051-0443(07)61274-3
  14. BJ McParland, "A study of patient radiation doses in interventional radiological procedures The British Journal of Radiology", Vol. 71, pp. 175-185, 1998. https://doi.org/10.1259/bjr.71.842.9579182
  15. D Bor, T Sancak, T Olgar, Y Elcim,, A Adanali, U Sanldilek, S Akyar, "Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology", British Journal of Radiology Vol. 77, pp.315-322, 2004. https://doi.org/10.1259/bjr/29942833
  16. Ruiz Cruces R, GarcIa-Granados J, Diaz Romero FJ, Hernandez Armas J. Estimation of effective dose in some digital angiographic and interventional procedures. Br J Radiol, Vol. 71, pp.42-47, 1998. https://doi.org/10.1259/bjr.71.841.9534698
  17. Verdun FR, Aroua A, Trueb PR, Vock P,Valley JF. Diagnostic and interventional radiology: a strategy to introduce reference dose level taking into account the national practice. Radiat Prot Dosimetry, Vol. 114, pp.188-91, 2005. https://doi.org/10.1093/rpd/nch547
  18. Vano E, Sanchez R, Fernandez JM, et al. Patient dose reference levels for interventional radiology : a national approach. Cardiovasc Intervent Radiol, Vol. 32, pp.19-4, 2009. https://doi.org/10.1007/s00270-008-9439-9
  19. Vano E, Jarvinen H, Kosunen A, et al. Patient dose in interventional radiology: a European survey. Radiat Prot Dosimetry, Vol. 129, pp.39-5, 2008. https://doi.org/10.1093/rpd/ncn024
  20. Miller DL, Kwon D, Bonavia GH. Reference levels for patient radiation doses in intercentional radiology; proposed initial values for U.S. practice, Vol. 253, No. 3, pp. 753-764, 2009. https://doi.org/10.1148/radiol.2533090354
  21. E Vano, R Sanchez, JM Fernandez, JJ Gallego, JF Verdu, M Gonzalez, A Azpiazu, A Segarra, MT Hernandez, M Canis, F Diaz, F Moreno, J Palmero, "Patient Dose Reference Levels for Interventional Radiology:A National Approach, Cardiovasc Intervent Radiol Vol. 32, pp.19-24, 2009. https://doi.org/10.1007/s00270-008-9439-9
  22. A KAWABE, Y TAKEDA, Y NAKAGIRI, " Reduction in Patient skin dose during interventional radiology with the use of an air gap substitute", The British Journal of Radiology, 2008.

Cited by