• Title/Summary/Keyword: group scanning

Search Result 1,257, Processing Time 0.029 seconds

SCANNING ELECTRON-MICROSCOPIC STUDY OF THE EFFECT OF CITRIC ACID AND TETRACYCLINE HCL CONDITIONING ON DISEASED ROOT SURFACE (구연산과 염산트라싸이클린이 치근면 탈회에 미치는 효과에 대한 주사전자현미경적 연구)

  • Kim, Young;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.24-34
    • /
    • 1995
  • The purpose of this study was to compare effects of demineralization of citric acid and tetracycline HCI on periodontally involved root surface. Twelve periodontally involved single rooted teeth were used. After scaling and root planing, root conditioning with citric acid and tetracycline HCI were carried and the teeth were processed scanning electron microscopic observation.The results were as follows: The scaled root surface was covered by much debris and calculus. The effect of demineralization of citric acid and tetracycline HCI was more reduced on scaling group than root planing group, because of hypermineralization of cementum surface and demineralization effect on root surface of tetracycline HCI showed tendency to reduction. The root planed group displayed more smooth root surface than scaling group, the surface was covered by smear layer, thus no exposure of dentinal tubule opening and collagen fiber, especially after root planing, citric acid and tetracycline HCl treated group showed exposure of dentinal tubule and collagen fiber, thus it was thought that new connective tissue attachment could be acquired.

  • PDF

Behavioral Changes of Rats following Cingulate or Other Cortical Damages (대상회전 기타 피질이 손상된 흰쥐들의 행동 변화)

  • Kim, Chung-Chin;Kim, Jong-Kyu;Kim, Myung-Suk
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.83-92
    • /
    • 1968
  • A study was planned to evaluate the effects of removal of the cingulate cortex upon the occurrence of any behavior commonly displayed by the rat, and to compare the effects of cingulectomy with those of removal of the parietal, parieto-occipital, or occipital regions. The subjects were 54 male albino rats (Holtzman strain, body weight $200{\sim}330\;gm$) including 14 rats in which the cingulate gyri between splenium and genu of the corpus callosum were bilaterally ablated by suction (cingulate group), 9 animals which had their parietal cortices (chiefly area 7) partially removed (parietal group), 9 rats whose parietal and occipital regions (chiefly areae 7 & 17), 13 animals in which the occipital cortices (chiefly area 17) were removed bilaterally (occipital group), and 9 normal rats (normal control group). Eighteen observation cages, each of which housed a subject and was provided with food and water ad lib., were arranged in 6 rows on a rack and the behavior of each subject was scanned by an observer at a distance of 1.5 m from the rack. The observer scanned the first and second rows 6 times in 1 min, then proceeded to the 3rd and 4th rows, scanning for another 1 min, and finally to the 5th and 6th rows. The speed of scanning was such that behavioral observations of all of the 18 rats were completed in 3 min, each subject receiving 6 observations. The scanning was repeated every 3 min for 18 min, which constituted one observation session and was followed by a 72 minutes' recess. The whole procedure was repeated through 24 hours so that a total of 576 behavioral observations were made on each subject in 16 observation sessions. Behaviors checked were sleeping, lying, lying and sniffing, standing, standing and sniffing, exploring, eating, drinking, grooming (included were washing, licking, and scratching), and others. Results obtained were as follows: 1. The cingulate group ate significantly more often than the normal control, the parietal, and the parieto-occipital groups. 2. Exploration was significantly less frequent in the cingulate group than in the normal control, the parietal, and the occipital groups. There was, in the case of the cingulate group, a significant negative correlation between the occurrence of eating and the exploratory activity. 3. The general activity, as judged from the value obtained by adding the occurrence of exploration, eating, drinking, grooming, and standing and sniffing, was significantly increased in the cingulate group compared with those of any other groups including the normal control. 4. Though statistically insignificant, the cingulate group slept least often among all the animal groups tested. 5. The parieto-occipital group tended to groom less, and the parietal group to eat less often than the normal control group did, but the difference was not significant. There were no significant differences among all the groups except the cingulate group as regards other behaviors analyzed. Based on the above results, it was inferred that the cingulate cortex exerts an inhibitory influence upon the occurrence of eating and general activity, while it tends to facilitate the occurrence of sleep.

  • PDF

Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change (진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향)

  • Choi, Kwanyong;Lim, Hyun Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

Effects of different surface treatments on the shear bond strength of veneering ceramic materials to zirconia

  • Abdullah, Adil Othman;Hui, Yu;Sun, Xudong;Pollington, Sarah;Muhammed, Fenik Kaml;Liu, Yi
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.65-74
    • /
    • 2019
  • PURPOSE. To evaluate and compare the effect of different materials and techniques on the shear bond strength of veneering ceramic materials to zirconia. MATERIALS AND METHODS. 136 sintered zirconia cubes were prepared and randomly divided into four study groups according to corresponding methods of surface treatment and materials: GLN (grinding followed by laser scanning using Noritake Cerabien ZR), SLN (sandblasting followed by laser scanning using Noritake Cerabien ZR), GLV (grinding followed by laser scanning using VITA VM 9), and SLV (sandblasting followed by laser scanning using VITA VM 9). Spraying technique was performed to coat the core. Profilometer, SEM, XRD, EDS, universal testing machine, and stereomicroscope were used to record surface roughness Ra, surface morphology, phase transformation, elemental compositions, shear bond strength SBS values, and failure types, respectively. Specimens were investigated in unaged (not immersed in artificial saliva) and aged (stored in artificial saliva for a month) conditions to evaluate SBS values. RESULTS. Grinding and GLN as first and second surface treatments provided satisfactory Ra values in both conditions ($1.05{\pm}0.24{\mu}m$, $1.30{\pm}0.21{\mu}m$) compared to sandblasting and other groups (P<.05). The group GLN showed the highest SBS values in both conditions ($30.97{\pm}3.12MPa$, $29.09{\pm}4.17MPa$), while group SLV recorded the lowest ($23.96{\pm}3.60MPa$, $22.95{\pm}3.68Mpa$) (P<.05). Sandblasting showed phase transformation from t-m. Mixed failure type was the commonest among all groups. CONCLUSION. GLN showed to be a reliable method which provided satisfactory bond strength between the veneer ceramic and zirconia. This method might preserve the integrity of fixed dental crowns.

A SCANNING ELECTRON MICROSCOPIC STUDY ON THE MARGINAL ADAPTIBILITY IN APPLYING THE CAVITY VARNISH AND DENTIN BONDING AGENT IN AMALGAM RESTORATIONS (아말감 수복시(修復時) Cavity varnish와 Bonding agent 도포(塗布)에 따른 접합성(接合性)에 관(關)한 주사전자현미경적(走査電子顯微鏡的) 연구(硏究))

  • Kim, Seok-Hoon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.107-119
    • /
    • 1990
  • The purpose of this study was to evaluate the marginal adaptability of the amalgam restorations in applying the cavity varnish (Copalite$^{(R)}$) and dentin bonding agent (Scotchbond 2$^{(R)}$) under the scanning electron microscope. For this study, eighteen sound extracted human molars were selected. Class I cavities in 12 teeth and class V cavities in 6 teeth were prepared using an air turbine with No. 701 tungsten carbide bur and finished using a low speed handpiece with No. 557 fissure bur. The prepared specimens were then divided into three groups including 4 class I cavities and 2 class V cavities in each group and restored as follows ; Group I. All the prepared cavities were restored with amalgam only (Control). Group II. Two layers of Copalite$^{(R)}$ cavity varnish were applied to the cavities with a gentle stream of air after each application and cavities were restored with amalgam. Group III. The enamel cavity margins were etched with 37% phosphoric acid gel for 60 sec., rinsed for 30 sec. and dried. One layer of visible lightcured Scotchbond Dental Adhesive$^{(R)}$ was applied and immediately cured for 20 seconds with visible light-cure unit and cavities were restored with amalgam. All the specimens were cut at the neck of the teeth and the occlusal halves of specimens were sectioned buccolingually in the longitudinal axis centering the amalgam restorations, using the disk. The cut specimens were ground with sandpapers (400, 600, 800, 1000 grit), and cleaned for 5 minutes in the ultrasonic cleaner (Brason Co. U.S.A.). In the cut surfaces, the amalgam - tooth interfaces were examined under the scanning electron microscope (JSM, 35C type, JEOL). The obtained results were as follows ; 1. The amalgam-tooth interfaces were reduced more significantly in the Copalite$^{(R)}$ and Scotchbond 2$^{(R)}$ application group than in the control group. 2. In the class I cavities, the Scotchbond 2$^{(R)}$ application group showed the findings similar to the Copalite$^{(R)}$ application group in the cavity floor, and the marginal adaptability was better in the side wall than in the cavity floor. 3. In the class I cavities, the Scotchbond 2$^{(R)}$ application group showed better marginal adaptability in the occlusal margin than in the gingival margin. 4. The marginal adaptability was in the order of the Scothbond 2$^{(R)}$ application group, the Copalite$^{(R)}$ application group and the control group.

  • PDF

A SEM STUDY OF RADIATION EFFECTS ON THE RAT MOLAR ENAMEL FORMATION (방사선조사가 백서 구치 법랑질형성에 미치는 영향에 관한 주사전자현미경적 연구)

  • Lee Kyung-Ho;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.409-422
    • /
    • 1995
  • The purpose of this study was to investigate the effects of radiation on the formation of rat molar enamel at the developmental stage. The experimental animals were divided into five groups and were irradiated single dose of 396cGy ; 1 st group on 14th day of gestation, 2nd group on 19th day of gestation, 3rd group on 3 days after birth, 4th group on 8 days after birth, 5th group on 28 days after birth. The control and 1, 2, 3, and 4th experimental groups were sacrificed on 2, 4, and 6 weeks and the 5th groups were sacrificed on 1 day and 2 weeks after irradiation. Distal 1/2 and occlusal 1/3 enamel surface of lingual side of lingual cusp, and fractured surface of lingual side of lingual cusp in a longitudinal direction of the mandibular first molar were examined using scanning electron microscope. The following results were obtained. 1. The roughness of enamel surface and enamel hypoplasia were increased in a sequence of 4th, 1st, 2nd, and 3rd experimental group, and the enamel cracks were increased in the 1st and 2nd experimental group. 2. The pattern of enamel hypoplasia had a network form on the 1st and 2nd experimental group, and appeared a linear shape on the 3rd experimental group, and then the crator-like enamel defects were observed in all experimental groups (especially 1st and 2nd experimental group) except 5th. 3. Dentinoenamel junction showed the clear-cut and straight appearance except 5th experimental group. 4. There was no significant difference between 5th experimental and control group.

  • PDF

The effects of tetracycline-HCI on SLA implant surface structure (염산 테트라싸이클린이 SLA 임플란트의 표면 구조에 미치는 영향)

  • Sea, Mi-Ran;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.251-263
    • /
    • 2007
  • The present study was performed to evaluate the effects of Tetracycline-HCI on the microstructure change of SLA implant surface according to application time. In the Tetracycline-HCI group, 6 implants were rubbed with sponges soaked $50mg/m{\ell}$ Tetracycline-HCI solution for O.5min., lmin., 1. 5min., 2min., 2.5min. and 3min. In the saline group. another 6 implants conditioned with sponges soaked saline using same methods. One implant wasn't conditioned anything. Then, the changes of surface roughness values were evaluated by optical interferometer & specimens were processed for scanning electron microscopic observation. The results of this study were as follows: 1. In both Tetracycline-HCI group & saline group, there are no significant differences between surface roughness values before & after surface detoxification. And in scanning electron microscopic observation. there are slightly changes of implant surface structures but this changes were not significant by comparison with no treatment implant surface. 2. In the changes of surface roughness values & the scanning electron microscopic observation, there were no significant differences between saline & Tetracycline-HCI groups. In conclusion, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI within 3 minutes can be applied for treatment of peri-implantitis in SLA surface implants. without surface microstructure changes.

THE ETCHING EFFECTS AND MICROTENSILE BOND STRENGTH OF TOTAL ETCHING AND SELF-ETCHING ADHESIVE SYSTEM ON UNGROUND ENAMEL (법랑질에 대한 total etching과 self-etching 접착제의 산부식 효과와 미세인장결합강도)

  • Oh, Sun-Kyong;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.273-280
    • /
    • 2004
  • The purpose of this study was to evaluate the etching effects and bond strength of total etching and self-etching adhesive system on unground enamel using scanning electron microscopy and microtensile bond strength test. The buccal coronal unground enamel from human extracted molars were prepared using low-speed diamond saw. Scotchbond Multi-Purpose (group SM). Clearfil SE Bond (group SE), or Adper Prompt L-Pop (group LP) were applied to the prepared teeth. and the blocks of resin composite (Filtek Z250) were built up incrementally. Resin tag formation was evaluated by scanning electron microscopy. after removal of enamel surface by acid dissolution and dehydration. For microtensile bond strength test. resin-bonded teeth were sectioned to give a bonded surface area of $1\textrm{mm}^2$. Microtensile bond strength test was perfomed. The results of this study were as follows. 1. A definite etching pattern was observed in Scotchbond Multi-Purpose group. 2. Self-etching groups were characterized as shallow and irregular etching patterns. 3. The results (mean) of microtensile bond strength were SM: 26.55 MPa, SE: 18.15 MPa, LP: 15.57 MPa. SM had significantly higher microtensile bond strength than 8E and PL (p < 0.05). but there was no significant differance between SE and PL.

INTERFACIAL MORPHOLOGY BETWEEN DENTIN AND ADHESIVES ACCORDING TO TREATMENT OF DENTIN SURFACE OF CERVICAL ABRASION LESION (치경부 마모병소의 상아질 표면처리 방식에 따른 상아질과 접착제 간의 계면 양상)

  • Lee, Yong-Hee;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.51-63
    • /
    • 2001
  • In order to know the effect of dentin bonding agents on the restoration of cervical abrasion, Scotchbond Multipurpose Single Bond and Clearfil Liner Bond 2 were used in 51 teeth with abrasion lesion and normal teeth. The surface structure and dentinal tubules of acid etched dentin and resin replica were examined using scanning electron microscopy. The interfacial morphology between dentin and adhesives was investigated by confocal laser scanning microscopy. Following results were obtained. 1. The hybrid layer and resin tag of the dentin showing cross-sectional surface of dentinal tubules are thicker and longer than those of dentin showing oblique surface of dentinal tubules. 2. The sclerotic cast was frequently observed in dentinal tubule, and the cast looked like cuboidal or rhomboidal-shaped crystals clumped from outer side to inner side. 3. The formation of hybrid layer and resin tag was the most prominent in Scotchbond Multipurpose group, whereas Clearfil Liner Bond 2 group showed very poor formation. The formation of hybrid layer and resin tag in Single Bond group was less than Scotchbond Multipurpose group.

  • PDF

Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization (광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.