• Title/Summary/Keyword: group scanning

Search Result 1,265, Processing Time 0.029 seconds

Evaluation of retrievability using a new soft resin based root canal filling material (레진 계통의 근관 충전재의 제거 용이성에 대한 평가)

  • Shin Su-Jung;Lee Yoon;Park Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.323-329
    • /
    • 2006
  • The aim of this study was to evaluate the retrievability of Resilon as a root canal filling material Twenty-seven human single-rooted extracted teeth were instrumented utilizing a crown down technique with Gates-Glidden burs and ProFile system. In group1 (n = 12) canals were obturated with gutta percha and AH-26 plus sealer using a continuous wave technique and backfilled. In group 2 (n = 15) Resilon was used as a filling material. Then teeth were sealed and kept in $37^{\circ}C$ and 100% humidity for 7 days. For retreatment, the samples were re-accessed and filling material was removed using Gates-Glidden burs and ProFiles. Teeth were sectioned longitudinally to compare the general cleanliness and amount of debris $({\times}\;75)$ using SEM. Chi-square test was used $({\alpha}\;=\;0.05)$ to analyze the data. The total time required for removal of filling materials was expressed as mean ${\pm}SD$ (min) and analyzed by the Student t-test $({\alpha}\;=\;0.05)$, Required time for retreatment was $3.25\;{\pm}\;0.32$ minutes for gutta percha/ AH 26 plus sealer and $3.05\;{\pm}\;0.34$ minutes for Resilon. There was no statistically significant difference between the two experimental groups. There was no significant difference between the groups in the cleanliness of the root canal wall. This study showed that Resilon was effectively removed by Gates-Glidden burs and ProFiles.

Effect of Prostaglandin F2 Alpha on E-cadherin, N-cadherin and Cell Adhesion in Ovarian Luteal Theca Cells (난소의 황체협막세포에서 E-cadherin, N-cadherin과 세포부착에 미치는 Prostaglandin F2 Alpha의 영향)

  • Lee, Sang-Hee;Jung, Bae Dong;Lee, Seunghyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.3
    • /
    • pp.360-369
    • /
    • 2019
  • Cadherins are essential transmembrane proteins that promote cell-cell adhesion and maintain the corpus luteum structure in the ovary. This study examined the influence of prostaglandin F2 alpha ($PGF2{\alpha}$) on E-cadherin, N-cadherin, and adhesion in luteal theca cells (LTCs). The luteal cells were isolated from the mid-phase corpus luteum, and the LTCs were cultured separately from the luteal heterogeneous cells according to the morphology of the mesenchymal cells and to determine if steroidogenic and endothelial cells of LTCs, 3beta-hydroxysteroid dehydrogenase ($3{\beta}$-HSD), and vascular endothelial growth factor receptor 2 (VEGFR2) mRNA were used. The LTCs were then incubated in the culture medium supplemented with 0.01, 0.1, and 1.0 mM $PGF2{\alpha}$ for 24 h, and the E-cadherin and N-cadherin proteins in the LTCs were detected by confocal laser scanning microscopy. The results revealed $3{\beta}$-HSD mRNA expression in the LTC but no VEGF2R mRNA expression. The E-cadherin and N-cadherin proteins of the LTCs were damaged in the 0.01, 0.1, and 1.0 mM $PGF2{\alpha}$ treatment groups, and the expression of the N-cadherin protein was reduced significantly in 0.01 mM $PGF2{\alpha}$ compared to the 0 mM $PGF2{\alpha}$ treatment groups (P<0.05). In addition, the number of attached LTCs were significantly lower in the 0.01 mM $PGF2{\alpha}$ treatment group than in the 0 mM $PGF2{\alpha}$ treatment group (P<0.05). In conclusion, $PGF2{\alpha}$ affected the disruption of cadherin proteins and cell adhesion in LTCs. These results may help better understand the cadherin and adhesion mechanism during corpus luteum regression in the ovary.

Documentation of Intangible Cultural Heritage Using Motion Capture Technology Focusing on the documentation of Seungmu, Salpuri and Taepyeongmu (부록 3. 모션캡쳐를 이용한 무형문화재의 기록작성 - 국가지정 중요무형문화재 승무·살풀이·태평무를 중심으로 -)

  • Park, Weonmo;Go, Jungil;Kim, Yongsuk
    • Korean Journal of Heritage: History & Science
    • /
    • v.39
    • /
    • pp.351-378
    • /
    • 2006
  • With the development of media, the methods for the documentation of intangible cultural heritage have been also developed and diversified. As well as the previous analogue ways of documentation, the have been recently applying new multi-media technologies focusing on digital pictures, sound sources, movies, etc. Among the new technologies, the documentation of intangible cultural heritage using the method of 'Motion Capture' has proved itself prominent especially in the fields that require three-dimensional documentation such as dances and performances. Motion Capture refers to the documentation technology which records the signals of the time varing positions derived from the sensors equipped on the surface of an object. It converts the signals from the sensors into digital data which can be plotted as points on the virtual coordinates of the computer and records the movement of the points during a certain period of time, as the object moves. It produces scientific data for the preservation of intangible cultural heritage, by displaying digital data which represents the virtual motion of a holder of an intangible cultural heritage. National Research Institute of Cultural Properties (NRICP) has been working on for the development of new documentation method for the Important Intangible Cultural Heritage designated by Korean government. This is to be done using 'motion capture' equipments which are also widely used for the computer graphics in movie or game industries. This project is designed to apply the motion capture technology for 3 years- from 2005 to 2007 - for 11 performances from 7 traditional dances of which body gestures have considerable values among the Important Intangible Cultural Heritage performances. This is to be supported by lottery funds. In 2005, the first year of the project, accumulated were data of single dances, such as Seungmu (monk's dance), Salpuri(a solo dance for spiritual cleansing dance), Taepyeongmu (dance of peace), which are relatively easy in terms of performing skills. In 2006, group dances, such as Jinju Geommu (Jinju sword dance), Seungjeonmu (dance for victory), Cheoyongmu (dance of Lord Cheoyong), etc., will be documented. In the last year of the project, 2007, education programme for comparative studies, analysis and transmission of intangible cultural heritage and three-dimensional contents for public service will be devised, based on the accumulated data, as well as the documentation of Hakyeonhwadae Habseolmu (crane dance combined with the lotus blossom dance). By describing the processes and results of motion capture documentation of Salpuri dance (Lee Mae-bang), Taepyeongmu (Kang seon-young) and Seungmu (Lee Mae-bang, Lee Ae-ju and Jung Jae-man) conducted in 2005, this report introduces a new approach for the documentation of intangible cultural heritage. During the first year of the project, two questions have been raised. First, how can we capture motions of a holder (dancer) without cutoffs during quite a long performance? After many times of tests, the motion capture system proved itself stable with continuous results. Second, how can we reproduce the accurate motion without the re-targeting process? The project re-created the most accurate motion of the dancer's gestures, applying the new technology to drew out the shape of the dancers's body digital data before the motion capture process for the first time in Korea. The accurate three-dimensional body models for four holders obtained by the body scanning enhanced the accuracy of the motion capture of the dance.

EFFECTS OF ACID ETCHING TIMES ON ENAMEL SURFACE MORPHOLOGY AND SHEAR BOND STRENGTH OF ORTHODONTIC ATTACHMENT TO ENAMEL (산부식시간이 법랑질 표면 부식형태와 교정장치의 전단접착강도에 미치는 영향에 관한 연구)

  • Nahm, Dong-Seok;Suhr, Cheong-Hoon;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.771-779
    • /
    • 1997
  • The purpose of this in vitro study was to evaluate the effects of different acid etching times on the enamel surface morphology, shear bond strength and debonding failure mode of orthodontic attachment. Ninety six extracted human mandibular premolars were divided into eight groups of twelve teeth. The buccal surfaces were etched with $37\%$, phosphoric acid for 5, 10, 15, 30, 45, 60, 90 and 120 seconds, respectively. Two teeth from each group were used for scanning electron microscope examination. On the etched buccal surfaces of remaining teeth, orthodontic attachments(lingual buttons) were bonded with light cured orthodontic adhesive. Twenty foot hours after bonding, a Instron universal testing machine was used to determine shear bond strength of orthodontic attachment to enamel. After debonding, bases of orthodontic attachments and enamel surfaces were examined under stereoscopic microscope to determine failure mode. Statistical analysis of the data was carried out with one nay ANOVA and Duncan's multiple range test The results were as follows; 1. There was no statistically significant difference in shear bond strengths between the various etching times(p<0.05). 2. The failure modes of orthodontic attachments had some differences. In 5, 10 and 15 seconds etching groups, the percentage of adhesive/enamel interface failure was higher than that of adhesive/attachment interface failure. On the contrary, in 30, 45, 60, 90 and 120 seconds etching groups, the results were reversed. 3. The etching patterns of enamel surfaces had a great variation. So, we could not find any correlation between etching pattern and bond strength. 4. The findings in this study indicate that in vitro reduction of the etching me to 5 seconds maintains clinically acceptable bond strength. However, further study is required to determine the cause of failure mode in 5, 10 and 15 seconds groups.

  • PDF

The study of bone density assessment on dental implant sites (임플란트 식립 부위의 골밀도 평가에 관한 연구)

  • Park, Su-Won;Jang, Soo-Mi;Choi, Byoung-Hwan;Son, Han-Na;Park, Bong-Chan;Kim, Chang-Hwan;Son, Jang-Ho;Sung, Iel-Yong;Lee, Ji-Ho; Cho, Yeong-Cheol
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.417-422
    • /
    • 2010
  • Introduction: Bone density is one of the important factors for the long term success of endosseous implants. The bone density varies from site to site and from patient to patient. A preoperative evaluation of the bone density is quite useful to oral surgeons for planning dental implantation. More accurate information on the bone density will help surgeons identify suitable implant sites, thereby increase the success rate of dental implantation. This study examined the correlation between the bone density measured preoperatively by computed tomography (CT) and the implant primary stability measured by resonance frequency analysis. Furthermore, the effects of the implant sites, gender, age and generalized systemic disorder patients on the bone density and primary implant stability were examined. Materials and Methods: One hundred and fourteen patients were selected. None of the patients had undergone a tooth extraction or bone graft history in the previous year. Preoperatively, the patients underwent CT scanning to evaluate the Hounsfield unit (HU), and resonance frequency analysis (RFA) was used to evaluate the implant primary stability at the time of implant installation. All implants were 4.0 mm diameter and 11.5 mm length US II. All patients were recorded and the HU and implant stability quotient (ISQ) value were evaluated according to the sites, gender and age. Results: The highest HU values were found in the mandibular anterior site ($827.6{\pm}151.4$), followed by the mandibular molar site ($797{\pm}135.1$), mandibular premolar site ($753.8{\pm}171.2$), maxillary anterior site ($726.3{\pm}154.4$), maxillary premolar site ($656.7{\pm}173.8$) and maxillary molar site ($621.5{\pm}164.9$). The ISQ value was the highest in the mandibular premolar site ($81.5{\pm}2.4$) followed by the mandibular molar site ($80.0{\pm}5.7$), maxillary anterior site ($77.4{\pm}4.1$), mandibular anterior site ($76.4{\pm}11.9$), maxillary premolar site ($74.2{\pm}14.3$) and maxillary molar site ($73.7{\pm}7.4$). The mean HU and ISQ value were similar in females and males. (HU: P=0.331, ISQ: P=0.595) No significant difference was also found in the age group respectively. However, the correlation coefficients between the variables showed a closed correlation between the HU and ISQ value. Conclusion: These results showed close correlation between the bone density (HU) and primary stability value (ISQ) at the time of implant installation (Correlation coefficients=0.497, P<0.01). These results strengthen the hypothesis that it might be possible to predict and quantify the initial implant stability and bone density from a presurgical CT diagnosis.

Clinical Study of Renal Cystic Diseases in Children (소아의 낭포성 신질환에 대한 임상적 고찰)

  • Kim, Ja Hyung;Kim, You Jeong;Lee, Byeong Seon;Ko, Tae Sung;Park, Young Seo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.232-239
    • /
    • 2002
  • Purpose : Renal cystic diseases comprise a mixed group of heritable, developmental and acquired disorders. Recently the use of imaging modalities such as ultrasonography and radionuclide scanning has increased the detection rate of renal cystic diseases. We studied to review the clinical features and treatment of renal cystic diseases in children. Methods : This study was performed in 95 children with renal cystic diseases in the Department of Pediatrics, Asan Medical Center from October 1989 to June 2001. Results : In 95 patients, there were 55 cases(58.0%) with multicystic dysplastic kidney(MCDK), 19 cases(20.0%) with simple renal cysts, 13 cases(13.7%) with hereditary polycystic kidney diseases( 7 with autosomal recessive type, 5 with autosomal dominant type, 1 with undetermined), 6 cases(6.3%) with renal cysts in tuberous sclerosis and 1 case(1.0%) with medullary cystic disease. All MCDK patients had no renal dysfunction and hypertension during the follow-up period. Three out of 13 with polycystic kidney diseases had progressed to end-stage renal disease during the follow-up period. One case with a simple cyst underwent laparoscopic malsupialization for decompression. Conclusion : Renal cystic diseases have diverse clinicopathologic features and variable prognosis. We emphasize that routine follow-up should be performed to prevent and to detect early treatable complication in renal cystic diseases. Therefore, their natural history and treatment need further investigation and long term follow-up is required.

Effects of the Enamel Erosion Caused by Certain Antipyretic and Analgesic Medicines for Children (일부 어린이 해열·진통제의 유치 법랑질 부식효과)

  • Cheun, Su-Kyung;Jeong, Moon-Jin;Ahn, Yong-Soon;Lee, Ye-Jin;Ko, Mi-Kyung;Jeong, Soon-Jeong;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.16 no.3
    • /
    • pp.235-241
    • /
    • 2016
  • This study was conducted to provide basic understanding regarding possible enamel erosion by three kinds of fist-aid antipyretic and analgesic medicines over a period of time, with comparison and analysis of the resulting deciduous teeth surface and microhardness changes. The analysis was performed using energy dispersive X-ray spectroscopy (EDX) and scanning electron microscope (SEM) to examine the surface erosion and changes. The Kruskal-Wallis test show differences in surface erosion and changes after 3, 5 and 8 days of treatment as well as before and after the treatment in each group. According to the results, there was no significant difference in the early deciduous teeth enamel surface microhardness (p>0.01). However there were signigicant changes after 3, 5, and 8 days (p<0.01). Calcim (Ca) and phosphorous (P) analysis using EDX showed significant differences in the enamel characteristics according to each tissue area after 8 days (p<0.05), but there was no significant difference in any of the areas for P content (p>0.05). In the surface observation with the SEM treatment with Children's Tylenol$^{(R)}$ tablet, which has the lowest pH, looked the roughest, followed by Brufen syrup for children and Children's Tylenol$^{(R)}$ suspension. Based on these results, it should be considered that antipyretic and analgesic medicines for children, which have lower pH values, may cause tooth erosion. Hence, it is necessary to give special attention to oral hygiene in young children or infants by brushing their teeth after such drugs are administered.

Characterization of New Bacillus thuringiensis Isolated with Bioactivities to Tobacco Cutworm, Spodoptera litura (Lepidoptera: Noctuidae) (담배거세미나방에 살충효과를 나타내는 새로운 Bacillus thuringiensis 균주의 특성)

  • Kim, Da-A;Kim, Jin-Su;Kil, Mi-Ra;Paek, Seung-Kyoung;Choi, Su-Yeon;Jin, Da-Yong;Youn, Young-Nam;Hwang, In-Cheon;Yu, Yong-Man
    • Korean journal of applied entomology
    • /
    • v.47 no.1
    • /
    • pp.87-93
    • /
    • 2008
  • Bacillus thuringiensis with selected high toxicities against tobacco cutworm, Spodoptera litura were isolated from domestic soils. When being observed under a phase-contrast microscope, the insecticidal crystal proteins were showed a bipyramidal crystal types. New CAB 109 isolate was identified to B. thuringiensis subsp. aizawai in the H serotype. As a results of insecticidal activities between CAB 109 isolate and 3 existing ready-made products against 3rd larva of S. litura, CAB 109 isolate showed 100% mortality with spore concentration $(1.3{\times}10^7cfu/ml)$. It was a very high insecticidal activity compared with a existing ready-made B. t. products. $LD_{50}$ values of CAB 109 isolate was $9.78{\times}10^5,\;6.87{\times}10^6\;and\;1.83{\times}10^7cfu/ml$ spore concentration against 2nd, 3rd and 4th larva of S. litura, respectively. Unlike Plutella xylostella, S. litura was slowly died after application up to 7 days. The weight of S. litura larva applied with CAB 109 isolate were 6-7 times less than controlled group. Even though it didn't die, it did not grow into next larva. The result observed with scanning electron microscope was that CAB 109 isolate of B. t. aizawai formed a typical bipyramidal crystal protein type. Otherwise, when CAB 109 isolate was examined with SDS-PAGE and with trypsin, there was no difference between CAB 109 strain and ready-made products of B. thuringiensis.

Streptococcus Mutans Biofilm Inhibition Effect of Indocyanine Green and Near Infrared Diode Laser (Indocyanine Green과 근적외선 다이오드 레이저의 Streptococcus mutans 세균막에 대한 억제 효과)

  • Kim, Yeowon;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.4
    • /
    • pp.446-453
    • /
    • 2020
  • The purpose of this study was to evaluate the effect of Indocyanine Green (ICG) and near-infrared (NIR) diode laser on Streptococcus mutans biofilms depending on ICG concentrations. S. mutans biofilms were formed on a Hydroxyapatite disk, and 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solutions dissolved in sterile distilled water and a NIR diode laser having a power of 300 mW and a wavelength of 808 nm were applied to the biofilms. The temperature changes of the biofilm surface according to the concentrations of the ICG solution were measured using a 1-channel thermocouple thermometer. Compared to the control group, in the groups with only the 3.0, 4.0, 5.0 mg/mL ICG solution application, and in the groups with the 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solution application and light irradiation, a statistically significant decrease in the bacterial counts were observed. The temperature increase according to the concentration of the ICG solutions was 9.53℃, 10.43℃, 11.40℃, 12.10℃, 12.67℃, and 13.63℃ in ICG solutions of 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mg/mL respectively. This study presents the potential for clinical application of ICG and NIR diode lasers as a new method for preventing dental caries.

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.