• Title/Summary/Keyword: group scanning

Search Result 1,252, Processing Time 0.028 seconds

QoS-Aware Group Scan Scheduling in WiMAX Networks (WiMAX 네트워크에서 QoS 기반의 그룹 스캔 스케쥴링 기법)

  • Choi, Jae-Kark;Yoo, Sang-Jo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2A
    • /
    • pp.186-195
    • /
    • 2010
  • For the fast target base station channel decision in WiMAX networks, fast group scanning scheme was suggested, in which mobile stations in proximity of each other form a group and scan the candidate channels dispersively. However, the previous group scanning scheme does not consider the different QoS requirements of each MS in a group. In this paper we propose the enhanced group scanning scheme, so-called QoS-aware group scan scheduling scheme, that makes mobile stations in a group scan the candidate channels without deteriorating the QoS requirements. We introduce the QoS-aware channel scanning concept of a individual mobile station and show the different scanning latencies due to the different QoS requirements. With the help of the efficient channel allocation by the serving BS, in the proposed scanning scheme, a mobile station with relatively higher QoS in a group scans less amount of candidate channels than the others with relatively lower QoS, while the mobile stations in a group still guarantees the fast target base station decision. The performance results show that our proposed scanning scheme results in the fast target base station decision while considering the QoS requirements of each MS.

3D Scanning Data Coordination and As-Built-BIM Construction Process Optimization - Utilization of Point Cloud Data for Structural Analysis

  • Kim, Tae Hyuk;Woo, Woontaek;Chung, Kwangryang
    • Architectural research
    • /
    • v.21 no.4
    • /
    • pp.111-116
    • /
    • 2019
  • The premise of this research is the recent advancement of Building Information Modeling(BIM) Technology and Laser Scanning Technology(3D Scanning). The purpose of the paper is to amplify the potential offered by the combination of BIM and Point Cloud Data (PCD) for structural analysis. Today, enormous amounts of construction site data can be potentially categorized and quantified through BIM software. One of the extraordinary strengths of BIM software comes from its collaborative feature, which can combine different sources of data and knowledge. There are vastly different ways to obtain multiple construction site data, and 3D scanning is one of the effective ways to collect close-to-reality construction site data. The objective of this paper is to emphasize the prospects of pre-scanning and post-scanning automation algorithms. The research aims to stimulate the recent development of 3D scanning and BIM technology to develop Scan-to-BIM. The paper will review the current issues of Scan-to-BIM tasks to achieve As-Built BIM and suggest how it can be improved. This paper will propose a method of coordinating and utilizing PCD for construction and structural analysis during construction.

Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods (서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성)

  • Cho, Young Beom;Chae, Heon Chung;Kim, Hee Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.366-376
    • /
    • 2013
  • The purpose of this study is to evaluate the marginal and internal fit of coping made by CAD/CAM using different scanning methods. Zirconia coping was made by each CAD/CAM system followed by intra-oral scanning, model optical scanning and model contact scanning. It was embedded into Epoxy Resin and was cut by buccal to lingual. AMD (Absolute marginal discrepancy), MG (Marginal gap), GA (Gap of axial), GL (Gap of line angle) and GO (Gap of occlusal) of each sample were measured. The result is as followed; 1. The mean value of AMD in Group 1, Group 2, Group 3 are $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$. The averages of MG in Group 1, Group 2, Group 3 are $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$. Statistically there is no difference in AMD and MG among the three Groups (Anova, P>0.05). 2. GA of Group 2 revealed statistically difference compared with Group 1 and Group 3 (Anova, P<0.05). 3. GL and GO of Group 1 showed statistically significant differences compared with Group 2 and Group 3 (Mann-whitney test (P<0.05). Zirconia copings made by 3 ways of scanning methods have no difference with conventional ceramics in AMD and MG which are known as the most important factors.

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.

Fast Group Scanning Scheme in IEEE 802.16e Networks (IEEE 802.16e에서 그룹 기반의 빠른 스캐닝 기법)

  • Choi, Jae-Kark;Yoo, Sang-Jo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.6A
    • /
    • pp.624-634
    • /
    • 2008
  • The mobile station which is about to do handover in IEEE 802.16e networks scans its neighboring base station channels to decide its next target base station. However, due to the lack of location information of its subscribers, the serving base station cannot provide any reliable candidate channel which is actually attachable by the scanning mobile stations, which makes the mobile station suffer from the long scanning time. Sometimes, long scanning time may cause the degradation of quality of service due to repeatable scan-duration or failure to start the handover procedure in time. To overcome these problems, in this paper, we propose a new protocol so called fast group scanning scheme, in which multiple mobile stations form a group to scan their neighboring base station channels simultaneously. Main contribution of this proposal is to find and decide a reliable target base station within a short scanning time. The fast group scanning scheme can be deployed to the cell network of the serving base station with a dynamic neighboring base station list management.

An Efficient Scanning Group and Order Decision Method Using Neighbor Network Information in Wireless LAN (WLAN에서 이웃 네트워크 정보를 이용한 효율적인 스캐닝 그룹 및 순서 결정 방법)

  • Kang, Dong-Wan;Choi, Jae-Kark;Yoo, Sang-Jo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2A
    • /
    • pp.142-152
    • /
    • 2010
  • When a mobile station(MS) performs a handover, in the IEEE 802.11 WLAN, MS's channel scanning for discovering new available APs is the dominating factor in handover latency, accounting 90% of overall latency. In order to reduce such a scanning latency, we focus on the method for reducing the number of channels for the MS in handover process to scan. With the help of IEEE 802.21 information server(IS), a proper order of groups of channels to be scanned is offered by the current AP depending on the information of neighbor APs in terms of the distance from serving AP, traffic load and network topology. By using this scanning order, the passive scanning of a MS in normal operation enables the MS to filter out the unavailable channels, and thus to classify the candidate channels of neighbor APs into three groups. Then, a handover-imminent MS can perform the active scanning from the most reliable group of channels. Simulation results show that the proposed scanning scheme reduce the scanning latency in comparison with the conventional scheme.

Research on jacket-fit satisfaction among men in their 20s and 30s using 3D body scanning (3D 바디 스캐닝을 활용한 20~30대 남성의 자켓 맞음새 만족도)

  • Lee, Sojung;Sohn, Jaemin;Kim, Dong-Eun
    • The Research Journal of the Costume Culture
    • /
    • v.26 no.1
    • /
    • pp.30-44
    • /
    • 2018
  • The study purpose was to investigate the jacket-fit satisfaction level of men in their 20s and 30s, using body-scanning data and a questionnaire. Thirty-five men were scanned using a 3D body scanner. The participants were divided into three groups (Small, Medium, and Large) based on their chest-circumference measurement. Their levels of satisfaction with the fit of their tailored jacket were compared by group. Chest, waist, and hip circumferences increased substantially as group size increased. The M-group was mostly satisfied with all body-site views. The S-group was especially dissatisfied with height, back width, waist circumference, and upper-arm circumference. The L-group was especially dissatisfied with waist circumference and hip circumference. The majority of the participants preferred the jacket closely fitted to their body. More than half of the participants thought finding a jacket of suitable size was difficult. When purchasing ready-to-wear jackets, the S-group and the M-group considered shoulder width important, while the L-group considered chest circumference the most important area. When evaluating the fit of ready-to-wear jackets, the L-group evaluated chest circumference, back width, and waist circumference as poor fits. The M-group evaluated sleeve length and shoulder width as poor fits, and the S-group agreed with respect to sleeve length. Body-satisfaction levels and matching jacket-satisfaction levels differed by body-size group, as did areas that need improvement. The conclusion is that size-group analysis using 3D body scanning can be utilized effectively for jacket-fit analysis. The findings of the current study can be applied to improving jacket fit among young male consumers.

Comparison of Scanning Electron Microscopic Specimens Dried with Different Methods (건조기법을 달리한 SEM 시료상의 비교검토)

  • Park, Chang-Hyun;Jang, Byung-Joon;Cho, Kang-Yong
    • Applied Microscopy
    • /
    • v.25 no.3
    • /
    • pp.33-39
    • /
    • 1995
  • To compare the quality of ultrastructural preservation of Scanning Electron Microscopic specimens dried with different methods; pure air-drying, air-drying with using Tetramethylsilane(TMS), four kind of air-drying using Hexamethyldisilazane(HMDS) and critical point drying(CPD), we conducted scanning electron microscopic observation on liver, skeletal muscle and intestinal tissues from laboratory rat treated with each method. In pure air drying group, severe distortion of tissue surface was observed, and in HMDS treated group, only liver tissue showed slight distortion. But in TMS treated group, each tissue showed a good presentation comparable to CPD group. The results suggest that the method of air-drying using TMS may be the former is less expensive and simple be and also time-saving.

  • PDF

A Study on the Communication Strategy to Risk Management of Agri-marine Products Distribution Policy (농수산물 유통정책의 위기관리에 따른 커뮤니케이션전략에 관한 연구 - 유통정책 갈등해소에 대한 스캐닝, 모니터링을 중심으로)

  • Kim, Man-Ki
    • Journal of Digital Convergence
    • /
    • v.6 no.1
    • /
    • pp.63-73
    • /
    • 2008
  • The present study attempted to explore effective scanning and monitoring in process of risk management on agri-marine products distribution policy. The interest public's group interests clash in accordance with theme for issue on marking policy. For executing a better systematic scanning and monitoring on actual affairs of marketing, selecting information personnel, gathering and analysing information, issue and risk management and their valuation with ongoing and simultaneously. Especially, In order to explore effective scanning and monitoring as a model of risk management, the study attempted to analyze within and without environment of marketing, to analyze issue management strategy, to evaluate issue activity for likelihood and impact, risk cycle analysis, interest public's group concerned, grade of interest public's group threatened(power, legitimacy, willingness), rapport(staying close, credibility, meeting expectation). And the study make an ongoing observation progress of subjects, and the serious subjects need have made an close observation. The study suggested to establish friendly relationship between organization and interest public's group, and to regularly accomplish two-way symmetric communication.

  • PDF

Evaluation of marginal and internal gap of wax coping fabricated by CAD/CAM system using intraoral scanner (구강 내 스캐너를 사용하여 CAD/CAM으로 제작된 왁스 코핑의 적합도 평가)

  • Kim, Dong-Yeon;Jung, Il-Do;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of wax copings fabricated from extraoral scanning with intraoral scanning. Methods: Fifteen study models(abutment of teeth 16) were made by PMMA. STL files of thirty abutment were prepared by intraoral scanning with extraoral scanning. Wax copings of thirty fabricated using CAD/CAM system. Marginal and internal gap of wax copings of thirty were measured by silicone replica technique and digital microscope(${\times}140$). Date were analyzed by using independent samples t-test. Results: Mean (SD) of two group were measured $55.61(27.42){\mu}m$ for totally gap of ES group and $60.67(33.14){\mu}m$ for totally gap of IS group. But marginal and internal gap of two group were not differences statistically significant(p>0.05). Conclusion: Evaluation of marginal and internal gap of two group showed that no differences statistically significant and clinically acceptable results.