• Title/Summary/Keyword: groundwater conservative area

Search Result 8, Processing Time 0.036 seconds

하수처리장 방류수에 용존된 무기화학종의 연속계측자료를 이용한 하천유량, 유속 및 방류량 추적

  • Kim, Gang-Ju;Han, Chan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.3-6
    • /
    • 2001
  • Various Parameters such as stream velocities, discharges, and dispersion coefficients of dissolved solutes were estimated by fitting 1-D nonreactive solute transport model to the time-series chemistry data. This study was done for the reaches of Mankyung River lower than the Jeonju Wastewater Treatment Plant (Jeonju WTP). Korea. Concentrations of inorganic chemicals in the stream waters are strongly influenced by mixing with the chemically distinct effluent from Jeonju WTP. Sulfate, EC. and the total major cation were proved to be nearly conservative in the study area front their relationships with chloride, the conservative chemical species. The solute transport model was constrained to the time-series concentrations for these 4 conservative species. The variations of concentration and discharge of Jeonju WTP were used as input parameters, and the stream velocities, dispersion coefficients, and concentrations and discharges of some inflows were optimized. The differences between the observed arid simulated values for alkalinities and nitrates are inversely correlated and show diurnal fluctuations, indicating the photosynthesis. The parameters obtained front this mode] range from 550 to 774 kcmd (stream discharge at the outlet of the study area), from 0.06 to 0.10 m/sec (flow velocity), and from 0.7 to 6.4 m$^2$/sec (dispersion coefficient). The history of Jeonju WTP discharge was well predicted when optimized, indicating the validity of the model results.

  • PDF

Consideration of the Groundwater Recharge Based on Environmental Isotopic Characteristics of the Small Basin in the Yeosu Area (환경동위원소를 이용한 여수지역 소유역에서의 지하수함양특성 고찰)

  • 고용권;배대석;김천수;김경수;정형재;김성용
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.93-106
    • /
    • 2001
  • The processes and rates of groundwater recharge were studied by long-term monitoring of groundwater level and isotopic compositions of precipitation, surface water and groundwater in the Yeosu area. The isotopic compositions of surface water and groundwater were directly related to the precipitation event. It is also shown that the minimum amount of precipitation for infiltration to groundwater is about 20mm. The isotopic variations of groundwater shows that the Isotopic composition of groundwater changed by each precipitation event between June and Sep. 2000 is gradually changed without input of precipitation again. It indicates that the groundwater recharged from the upper part is mixed with the groundwater in reservoir. The infiltration rate of first precipitation event after a dry season is estimated to be 16.5% using isotopic mixing equations. It is expected that the groundwater recharge rate could be estimated more quantitavely, if the isotopic method is combined with the conservative methods.

  • PDF

Effects of Site-scale Anisotropy of an Aquifer on Groundwater Remediation (지하수 오염복원에서 현장규모 이방성의 효과)

  • Lee, Jae-Min;Lee, Byung-Sun;Woo, Nam-Chil
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.17-28
    • /
    • 2010
  • As a preliminary survey to improve efficiency of well-based permeable reactive barrier system for groundwater remediation, this site-scale study was carried to identify the flowpaths and controlling factors of plume at a remediation site in Suwon City, Korea. A total of 22 monitoring wells were installed as a grid system in the $4m{\times}4m$ square area by 1-m interval. For the groundwater characterization, various tests were performed including water-level monitoring, water sampling & analysis, pumping and slug tests, and tracer tests. The aquifer appeared to be unconfined with hydraulic conductivities (K) ranging from $2.6{\times}10^{-4}cm/s$ to $9.5{\times}10^{-3}cm/s$. The average linear velocity of groundwater was estimated to be $2.94{\times}10^{-6}m/s$, and the longitudinal dispersivity of a conservative tracer to be $5.94{\times}10^{-7}m^2/s$. Groundwater plume moves preferentially through the high-K zones, and the relatively high ion concentrations along the low-K zones implying deterred groundwater flow. Consequently, the spatial variation of hydraulic conductivity caused by aquifer heterogeneity and anisotropy appears to be the most important factor to maximize the effect of plume treatment system for application of in-situ groundwater remediation techniques.

MODFLOW or FEFLOW: A Case Study of Groundwater Model Selection for the Upper Waikato Catchment, New Zealand

  • Weir, Julian;Moore, Dr Catherine;Hadfield, John
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.14-14
    • /
    • 2011
  • Groundwater in the Waikatoregion is a valuable resource for agriculture, water supply, forestry and industries. The 434,000 ha study area comprises the upper Waikato River catchment from the outflow of Lake Taupo (New Zealand's largest lake) through to Lake Karapiro (a man-made hydro lake with high recreational value) (Figure 1). Water quality in the area is naturally high. However, there are indications that this quality is deteriorating as a result of land use intensification and deforestation. Compounding this concern for decision makers is the lag time between land use changes and the realisation of effects on groundwater and surface water quality. It is expected that the effects of land use changes have not yet fully manifested, and additional intensification may take decadesto fully develop, further compounding the deterioration. Consequently, Environment Waikato (EW) have proposed a programme of work to develop a groundwater model to assist managing water quality and appropriate policy development within the catchment. One of the most important and critical decisions of any modelling exercise is the choice of the modelling platform to be used. It must not inhibit future decision making and scenario exploration and needs to allow as accurate representation of reality as feasible. With this in mind, EW requested that two modelling platforms, MODFLOW/MT3DMS and FEFLOW, be assessed for their ability to deliver the long-term modelling objectives for this project. The two platforms were compared alongside various selection criteria including complexity of model set-up and development, computational burden, ease and accuracy of representing surface water-groundwater interactions, precision in predictive scenarios and ease with which the model input and output files could be interrogated. This latter criteria is essential for the thorough assessment of predictive uncertainty with third-party software, such as PEST. This paper will focus on the attributes of each modelling platform and the comparison of the two approaches against the key criteria in the selection process. Primarily due to the ease of handling and developing input files and interrogating output files, MODFLOW/MT3DMS was selected as the preferred platform. Other advantages and disadvantages of the two modelling platforms were somewhat balanced. A preliminary regional groundwater numerical model of the study area was subsequently constructed. The model simulates steady state groundwater and surface water flows using MODFLOW and transient contaminant transport with MT3DMS, focussing on nitrate nitrogen (as a conservative solute). Geological information for this project was provided by GNS Science. Professional peer review was completed by Dr. Vince Bidwell (of Lincoln Environmental).

  • PDF

Prediction of Leachate Migration from Waste Disposal Site to Underground LPG Storage Facility and Review of Contamination Control Method by Numerical Simulations (수치모의를 통한 지하 LPG 저장시설에 인접한 폐기물매립지에서의 침출수이동 예측 및 제어공법 검토)

  • 한일영;서일원;오경택
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.2
    • /
    • pp.51-59
    • /
    • 1996
  • In case waste disposal site is to be constructed close to the underground facilities such as LPG storage cavern which is completely maintained by groundwater pressure, it is generally requested that the possibility on leachate contamination of cavern area be reviewed and the countermeasure, if it is estimated cavern area is severely affected by leachate, be taken into consideration. Prediction was performed and leachate control plan was made using by analytical and the numerical analysis on the leachate migration which is likely to happen at the area between the proposed waste disposal site and the underground LPG storage cavern located at the U petrochemical complex. Analytical solutions were obtained by the conservative mass advection-diffusion equation and the effect of advection and dispersion factor on the leachate migration was reviewed through peclet number calculation and the functional relationship between the factors and leachate transport velocity was established, which leads to enable us to predict the leachate transport velocity without difficulties when different parameters (factors) are used for analytical solution. Numerical solutions were obtained by FEM using AQUA2D which is for the simulation of groundwater flow and contaminant transport. 3-D discrete fracture models were simulated and fracture flow analysis was performed and feasibility study on the water-curtain system was conducted through the fracture connectivity analysis in rock mass. As results of those analyses, it was interpreted that the leachate would trespass on the LPG storage cavern area in 30 years from the proposed wate disposal site and the vertical water-curtain system was effective mathod for the prevention of leachate's migration further into the cavern area.

  • PDF

Applicability examinations of induced drainage system for reduction of uplift pressure in underpass structures: Numerical study (지하차도 부력저감을 위한 유도배수공법의 적용성 검토: 수치해석적 연구)

  • Jo, Seon-Ah;Jin, Gyu-Nam;Sim, Young-Jong;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.2
    • /
    • pp.123-134
    • /
    • 2013
  • Urban underground structures at low ground elevations (i.e. shallow substructures) unlike typical tunnel structures are subjected to low overburden and high water pressures. This often causes the underground structures to become damaged. Various conventional methods for the urban underpass structures such as dead weight increasement, round anchors, and tension piles, are significantly conservative and provok concerns about the costly, time-consuming installation process. Recently, permanent drainage system becomes to widely use for supplementing the conventional method's shortcomings, but, it is applied without the considerations for ground conditions and water table. In this study, therefore, numerical analyses are performed with various parameters such as groundwater level, wall height, and ground conditions in order to establish design guidelines for induced drainage system which is a kind of the permanent drainage method constructed at the Y-area. According to the numerical results, the induced drainage system is very effective in reducing the uplift pressure that acts on the base of underpass structures.

Prediction of Potential Risk Posed by a Military Gunnery Range after Flood Control Reservoir Construction (홍수조절지 건설 후 사격장 주변지역의 위해성예측 사례연구)

  • Ryu, Hye-Rim;Han, Joon-Kyoung;Nam, Kyoung-Phile;Bae, Bum-Han
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.1
    • /
    • pp.87-96
    • /
    • 2007
  • Risk assessment was carried out in order to improve the remediation and management strategy on a contaminated gunnery site, where a flood control reservoir is under construction nearby. Six chemicals, including explosive chemicals and heavy metals, which were suspected to possess risk to humans by leaching events from the site were the target pollutants for the assessment. A site-specific conceptual site model was constructed based on effective, reasonable exposure pathways to avoid any overestimation of the risk. Also, conservative default values were adapted to prevent underestimation of the risk when site-specific values were not available. The risks of the six contaminants were calculated by API's Decision Support System for Exposure and Risk Assessment with several assumptions. In the crater-formed-area(Ac), the non-carcinogenic risks(i.e., HI values) of TNT(Tri-Nitro-Toluene) and Cd were slightly larger than 1, and for RDX(Royal Demolition Explosives), over 50. The total non-carcinogenic risk of the whole gunnery range calculated to a significantly high value of 62.5. Carcinogenicity of Cd was estimated to be about $10^{-3}$, while that of Pb was about $5\;{\times}\;10^{-4}$, which greatly exceeded the generally acceptable carcinogenic risk level of $10^{-4}{\sim}10^{-6}$. The risk assessment results suggest that an immediate remediation practice for both carcinogens and non-carcinogens are required before the reservoir construction. However, for more accurate risk assessment, more specific estimations on condition shifts due to the construction of the reservoir are required, and more over, the effects of the pollutants to the ecosystem is also necessary to be evaluated.