• 제목/요약/키워드: grounding system

검색결과 467건 처리시간 0.03초

접지그리드의 접지임피던스 측정 기법 (Measurement method of ground impedance for the grounding grid)

  • 이복희;최종혁;최영철;유재덕;백영환;김동성;신희경;유양우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1487_1488
    • /
    • 2009
  • In these days, the common grounding systems are adapted in most large structures. In order to evaluate the performance of grounding system, it is needed to measure ground impedance. Measuring methods of ground impedance for a large scale grounding systems have not been yet presented in detail. In this paper, we analyze earth mutual resistance and mutual coupling of $15{\times}15m$ grounding grid in different arrangements of auxiliary electrode. As a results, the auxiliary electrodes are installed where the error rate due to earth mutual resistance is less than 5%. Also, the potential lead is installed at obtuse angle from the current lead and the overlapped length between potential lead and grounding grid are minimized.

  • PDF

접지시스템의 설계를 위한 대지저항률의 합리적인 측정방법 고찰 (Examinations on the Reasonable Measuring Methods of the Soil Resistivity for Design of Grounding System)

  • 이복희;김기복;이승훈;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.35-41
    • /
    • 2011
  • In order to design effectively the grounding system, it is very important to determine the optimum soil resistivity at the desired location of the connection to earth. This paper deals with the reasonable methods of measuring the soil resistivity where grounding electrodes are buried. The soil resistivity at three test sites with different resistivity of soil were measured as functions of the spacing between the test probes in the Wenner's four-point method and the length of test ground rod in the three-point method. In the case of the three-point method, the length of test ground rod of 2-10[m] in length was appropriate in two-layered soil structure. In the length range of 2-10[m], the results measured by the three-point method using the test ground rod with the length corresponding to the spacing between the test probes of the Wenner's four-point method are in good agreement with the data obtained from the Wenner's four-point method.

임펄스전압에 의한 동심원통형 전극계에서 토양 이온화특성 분석 (Analysis of Soil lonization Characteristics in Concentric Cylindrical Electrode System under Impulse Voltages)

  • 김회구;박건훈;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.32-39
    • /
    • 2008
  • 본 논문은 뇌임펄스전압에 의한 토양의 이온화 현상과 모델접지시스템의 과도적 특성에 관련된 파라미터에 관한 것으로 건조 모래와 습한 모래에 대한 이온화 특성을 치수가 다른 동심원통형 전극계의 실험 용기를 이용하여 연구하였다. 결과로써, 높은 임펄스전압이 인가된 모래의 비선형 전기적 특성은 이온화 과정에 의해 발생하였다. 모래의 과도임피던스는 수분의 함유량과 인가임펄스전압의 크기에 의존하며, 수분의 함유량과 인가전압의 크기의 증가에 따라 접지임피던스는 감소하였다. 본 연구결과는 뇌서지에 대하여 우수한 성능을 가지는 접지시스템의 설계에 유용한 정보가 될 것이다

방식층 보호장치의 설치에 따른 지중송전케이블 시스 유기전압 해석 (Analysis of Sheath Induced Voltage in Transmission Power Cable Connected with CCPU)

  • 이준성;이종범;김영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권1호
    • /
    • pp.19-25
    • /
    • 2000
  • This paper describes the sheath induced voltage in underground transmission cable system which will be operated with cable cover protection unit(CCPU). Simulation was carried out to analyze the sheath induced voltage in the real cable system which was installed by 154㎸ CV cable in the case with and without CCPU. The sheath induced voltage will be also analyzed according to the change of grounding method, fault resistance and fault angle. Simulation was performed using EMTP and ATP Draw, the simulation results show whether the CCPU in necessary or not in underground transmission power cable system.

  • PDF

전류 및 전위 보조전극을 수직으로 배치하는 전위강하법을 이용한 접지저항의 측정 (Measurement of the Ground Resistance using the Fall-of-Potential Method with the Vertically-placed Current and Potential Auxiliary Electrodes)

  • 이복희;김기복;김유하
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.53-60
    • /
    • 2012
  • The fall-of-potential method is commonly used in measuring the ground resistance of large-scaled grounding system and the current and potential auxiliary electrodes are horizontally arranged. Because the distances between the ground grid to be tested and auxiliary electrodes are limited in downtown areas, it is very difficult to measure accurately the ground resistance of large-scaled grounding system. In this paper, the fall-of-potential method of measuring the ground resistance with the vertically-placed current and potential auxiliary electrodes was examined and discussed. The validity and good accuracy of the proposed method of measuring the ground resistance were confirmed through various simulations and actual tests carried out in uniform and two-layer soil structures.

22.9kV 수전설비 Mesh 접지설계의 안전성 평가 사례 (A Safety Assessment of a Mesh Grounding System for 22.9kV Substations)

  • 박상교;최창규
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.54-60
    • /
    • 2013
  • There is increasing demand for practical groundings for small-area substations because of the recent revision of Korea's Electrotechnical Regulations, which necessitates the method of evaluating their safety. This paper proposes a practical mesh grounding system for 22.9kV substations and studies how to evaluate its safety. The proposed grounding system is proved to obey the safety criteria of ANSI/IEEE Std. 80 via ANSI/IEEE Std. 80 method and computer simulation.

정보화 건측물을 위한 접지감시시스템 개발 (Development of the grounding monitoring system for intelligent buildings)

  • 조성철;이태형;엄주홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.196-197
    • /
    • 2006
  • An effective method is described for monitoring the ground impedance of intelligent building and power system. Most of grounding system of buildings are interconnected to extensive grounding network of power line, signal and control line, telecommunication line, and etc. Therefore, the residual voltages of power frequency and its harmonics may have an significant influence on the accurate measurement of ground impedance. For eliminating the influence of residual voltage, we developed a test power source for generating the 110[Hz] square wave and used digital filtering method in this research.

  • PDF

Towards Designing Human Interactions for Learning Support System using Virtual Reality Technology

  • Iwane, Noriyuki
    • International journal of advanced smart convergence
    • /
    • 제3권1호
    • /
    • pp.11-14
    • /
    • 2014
  • We have been designing human interactions for some learning support system or education system. The design is based on a symbol grounding model. The model is applicable to many learning domains using virtual reality technology. The design policy is simple and compact. In order to realize the policy we use/reuse some devices from the viewpoint of virtual reality. This paper introduces basic ideas and explains several example cases based on the idea.

방식층 보호장치 결선방식의 혼용에 따른 영향분석 (The Effects of Multi-Bonding Methods for Cable Covering Protection Unit)

  • 김정년;하체웅;이수길
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권10호
    • /
    • pp.489-492
    • /
    • 2001
  • The connection method of CCPU has been changed from connection between sheath and grounding to connection between sheaths without grounding since 1997. In domestic, there is so many cases that cables circuits were installed before 1997, added in same route after that, operated as multi-connecting systems of CCPU in same route. This paper examine the problem of multi-connecting system by EMTP simulation, and presents methods to improve the system characteristics.

  • PDF

배전용 접지전극의 전극별.공중별 특성시험에 관한 연구 (A study on the characteristic test of the grounding electrodes used in distribution lines)

  • 박상만;박재덕;강문호;최종기;박영근;심건보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.54-56
    • /
    • 2005
  • On the overhead distribution lines, we generally use a copper rod as a grounding electrode. It is a economical metallic structure. Recently, many new electrodes have been developed and used in the distribution system of KEPCO. Before using new grounding electrode. we need to measure the performance of each electrode for comparative analysis. This report describes the characteristic test of the grounding electrodes used in KEPCO.

  • PDF