• Title/Summary/Keyword: ground model test

Search Result 1,134, Processing Time 0.028 seconds

Prediction of Soil-water Characteristic Curve and Unsaturated Permeability Coefficient of Reclaimed Ground (불포화 준설매립 지반의 흙-수분 특성곡선 및 불포화 투수계수 예측)

  • 신은철;이학주;오영인
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.109-120
    • /
    • 2004
  • There has been outstanding research on the soil-water characteristic curves of unsaturated soils over the past several decades. Unfortunately, unsaturated soil mechanics has not been considered as an important factor in Korea. In this paper, laboratory test and numerical analysis(SoilVision Professional ver 3.04) were performed to investigate the prediction method of soil-water characteristic curve and unsaturated permeability coefficient in reclaimed ground. The pressure cell, desiccator, and tensiometor tests were conducted on three types of reclaimed soils(dredged soil, sand, weathered granite soil). Numerical analysis was executed to compare the results with the laboratory test results and also compared with the results of each prediction method. Based on the laboratory test, three different types of soils have shown different soil-water characteristic curves. The hysteresis fir these soils is clearly defined. As a result of numerical analysis, Fredlund & Xing's method and Fredlund & Wilson's model proved to worke out well for reclaimed ground soils in Korea. Also, predicting method based on the soil-water characteristic curves from the particle-size distributions is flirty reliable for estimating unsaturated permeability coefficient.

Verification and Mitigation of Seismic Failure in Concrete Piers under Near-field Earthquakes

  • Ikeda, Shoji;Hayashi, Kazuhiko;Naganuma, Toshihiko
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.1-11
    • /
    • 2007
  • This paper verifies the difference of the seismic behavior and seismic damage of the neighboring two reinforced concrete piers damaged by the 1995 Hyogoken Nanbu earthquake. The two piers were almost the same size, carrying slightly different dead load, and were provided with the same reinforcement arrangement except the amount of longitudinal reinforcement at the bottom portion of the piers. The pier with more reinforcement was completely collapsed due to this near field earthquake by shear failure at the longitudinal reinforcement cut-off while the other was only damaged at the bottom by flexure even though the longitudinal reinforcement cut-off was also existed at the mid height of the pier. According to the results of the pseudo dynamic test, the seismic damage was recognized to be greatly dependent on the ground motion characteristics even though the employed ground motions had the same peak acceleration. The severe damage was observed when the test employed the seismic wave that had strong influence to the longer period range compared to the initial natural period of the pier. On the other hand, based on the similar model experiment, the defect of gas-pressure welded splice of longitudinal reinforcement was revealed to save the piers against collapse due to the so-called fail-safe mechanism contrary to the intuitive opinion of some researchers. It was concluded that the primary cause of the collapse of the pier was the extremely strong intensity and peculiar characteristics of the earthquake motion according to both the site-specific and the structure-specific effects.

Seismic Performance of Steel Industrial Storage Racks Subjected to Korea Earthquakes (국내 발생지진에 의한 물류창고 강재 적재설비의 내진성능 평가)

  • Jeon, Jong-Su;Choi, Hyoungsuk;Seo, Youngdeuk;Kim, Chunggil;Heo, Gwanghee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.149-160
    • /
    • 2018
  • This study experimentally and analytically examines the seismic vulnerability of steel rack storage frames subjected to Korea earthquakes (2016 Gyeongju earthquake and 2017 Pohang earthquake). To achieve this aim, this study selects a three-story, one-bay steel rack frame with a typical configuration of rack frame in Korea. Firstly, the local behavior for frame components is examined by performing monotonic and/or cyclic load tests and the global response and dynamic characteristics of the subject rack frame are investigated by conducting a shaking table test. The analytical model of the rack frame is then created based on the experimental results and is used to perform nonlinear time history analyses with recorded Korea earthquakes. The seismic demand of the rack frame is considerably affected by the spectral acceleration response, instead of peak ground accelerations (peak floor accelerations). Moreover, the collapse fragility curve of the rack frame is developed using incremental dynamic analyses for the Gyeongju and Pohang earthquakes. Fragility results indicate that the ground motion characteristics of these earthquakes do not significantly affect the frame vulnerability at the collapse state.

Bearing Capacity Study for Small-Scale Testing of Rotary Pile with Helix Plate (축소모형 로타리 파일의 나선날개에 따른 지지성능에 관한 연구)

  • Shin, Eun-Chul;Kim, Kyeong-Sig;Moon, Hyeong-Rok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.1
    • /
    • pp.37-46
    • /
    • 2016
  • Rotary pile consists a single or multiple helix plate and it is installed into the ground using the rotation of the helix plate. Rotary pile in soft ground is able to be supported by pile shaft and helix plate. When the pile is installed into hard layer relatively, the end bearing capacity is possible to be increased by the lower helix plate. In this paper, small-size rotary piles were manufactured with using steel pipe which is reduced to 1/5 size of the rotary pile on the construction field. Pile load test was carried out on the foundation soil which was formed by weathered soft soil. The bearing capacity of small-scale piles depends on the number of helix plate, the length of plate diameter, and an interval of plates, respectively. The bearing capacity of pile increases about 40% with 3 helix plate and it is also confirmed that the bearing capacity is improved about 10% as the increment of plate interval.

Behaviour of Foundation Ground with Marine Clay in Anisotropy (이방성을 갖는 해성점토 기초지반의 거동해석)

  • Kim, Myeon-Su;Lee, Kang-Il;Kim, Chan-Ki;Yun, Jung-Mann;Baek, Won-Jin
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.1
    • /
    • pp.11-21
    • /
    • 2015
  • This study aims at investigating of the behavioral characteristics of foundation ground subjected to a strip load in anisotropy. Using marine clays sampled at Shihwa area, a series of laboratory tests including triaxial compressive test, plane strain compressive and expansion tests that allows horizontal deformation only and zero strain (${\varepsilon}_2$) in the direction of intermediate stress (${\sigma}_2$) are conducted. In addition, a numerical analysis using parameters obtained from the tests is carried out. In the numerical analysis, Cam-clay model that simulates the behavior of natural deposited clay properly is adopted. The analysis results show that the vertical displacements of the plane strain compressive tests are relatively larger than those of triaxial compressive tests by 18-25%. Likewise, the horizontal displacements is 13-19% larger.

The Behavior and Resistance of Connected-pile Foundations for Transmission Tower from In-situ Lateral Load Tests (송전용 철탑기초의 현장수평재하시험을 통한 연결형 말뚝기초의 거동 및 지지력특성)

  • Kyung, Doo-Hyun;Lee, Jun-Hwan;Paik, Kyu-Ho;Kim, Dae-Hong;Kim, Dae-Hak
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.2
    • /
    • pp.57-70
    • /
    • 2012
  • For soft ground, a pile foundation is typically used as a substructure of transmission tower. However, differential settlement between the foundations can cause structural damage of transmission tower. The connected-pile foundation is a type of group foundation consisting of four foundations connected with beams, and it was suggested in USA and Japan. In this study, a series of 1/8 scale model pile tests were performed to investigate the effect of load direction and stiffness of connecting beam on the responses of connected-pile foundation. As a result, the load capacities of the connected-pile foundation were larger than those of the conventional group pile foundation. For example, under the given test conditions in this paper, the resistibility against differential settlement was improved significantly for connected-pile foundation and its efficiency was maximized when the stiffness of connecting beams is about 25% of the mat foundation.

A Sensitivity Analysis for the Geotechnical Parameters Estimation of a Ground around a Granular Compaction Pile (쇄석다짐말뚝 주변지반의 지반정수산정을 위한 민감도 분석)

  • Han, Yushik;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.12
    • /
    • pp.5-15
    • /
    • 2015
  • The GCP (Granular Compaction Pile) for the improvement objective of soft ground has been frequently studied. However, these studies were the results deduced on the basis of the numerical analysis and the laboratory model tests, and there was no study method to apply the effects of the bulging failure of a flexible pile. In this study, the sensitivity of the load-settlement curves of the uniform and the tapered GCP dependant on the geotechnical parameters estimated from N value of standard penetration test (SPT) was analyzed. It was estimated reasonably that, in the very soft clay soil (N=3 or less), elastic modulus was 700~2000 kPa and Poisson's ratio was 0.40~0.48.

Earth Pressure on a Rigid wall due to Loads Condition and Distance (상재하중의 크기와 이격거리에 따른 강성벽체의 토압분포)

  • Oh, Bun-Jin;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.51-60
    • /
    • 2010
  • Earth pressure due to gravity generally increases linearly with the depth, but the distribution of earth pressure due to surface load depends on the loading condition, the ground condition, and the boundary condition. In this study, the earth pressure on a rigid wall due to the vertical surface load was measured in experiments. Rigid wall was built in the model test box, and it was filled with homogeneous sandy ground (width 30 cm, height 88 cm, length 110 cm). Rigid wall was composed of 8 segments, which were tested on the two load cells. In the tests, we observed the distribution of the earth pressure on the rigid wall depending on the vertical surface load and it's location. According to the test results, the lateral earth pressure due to the vertical surface load showed its maximum value at a constant depth and decreased with the depth, to the negligible value at the critical depth. The critical depth and the depth at which lateral earth pressure reaches its maximum were not decided by the magnitude of the vertical surface load. They were dependant on the distance from the rigid wall.

TBM mechanical characteristics for NFGM in mechanized tunnelling

  • Pill-Bae Hwang;Beom-Ju kim;Seok-Won Lee
    • Geomechanics and Engineering
    • /
    • v.38 no.5
    • /
    • pp.477-486
    • /
    • 2024
  • The process of inspecting and replacing cutting tools in a shield tunnel boring machine (TBM) is called cutterhead intervention (CHI) (Farrokh and Kim 2018). Since CHI is performed by a worker who enters the chamber in TBM, the worker is directly exposed to high water pressure and huge water inflow, especially in areas with high ground water levels, causing health problems for the worker and shortening of available working hours (Kindwall 1990). Ham et al. (2022) proposed a method of reducing the water pressure and water inflow by injecting a grout solution into the ground through the shield TBM chamber, and named it the new face grouting method (NFGM). In this study, the TBM mechanical characteristics including the injection pressure of the grout solution and the cutterhead rotation speed were determined for the best performance of the NFGM. To find the appropriate injection pressure, the water inflow volume according to the injection pressure change was measured by using a water inflow test apparatus. A model torque test apparatus was manufactured to find the appropriate cutterhead rotation speed by investigating the change in the status of the grout solution according to the rotation speed change. In addition, to prove the validity of this study, comprehensive water inflow tests were carried out. The results of the tests showed that the injection pressure equal to overburden pressure + (0.10 ~ 0.15) MPa and the cutterhead rotation speed of 0.8 to 1.0 RPM are the most appropriate. In the actual construction site, it is recommended to select an appropriate value within the proposed range while considering the economic feasibility and workability.

Experimental Study on Visco-Plastic Characteristics of Silicate-Grouted Soil (물유리계 약액고결토의 점.소성특성에 관한 실험적 연구)

  • 정형식;유재일
    • Geotechnical Engineering
    • /
    • v.4 no.3
    • /
    • pp.53-62
    • /
    • 1988
  • When a ground soil is under the constant continuous stress less than the failure strength of that soil, its deformation, in some cases, will increase continuously as time goes on due to creep phenomena. Deformation of soil caused by creep behavior will appear in various types depending on the elastic, plastic, viscous properties of soil. Therefore in this study, visco-plastic characteristics of grouted soil was studied by analysing the result of uniaxial creep test on the grouted soil. As a result of this research, it was found that the rheological model of grouted soil can be decided as Vyalov model and the visco-plastic properties of grouted soil is influenced by the content of silicate in grout.

  • PDF