• Title/Summary/Keyword: ground building

Search Result 1,643, Processing Time 0.029 seconds

Analysis of Ground Subsidence Influencing Factors Using Underground Facility Property Information (지하매설물 속성정보를 활용한 지반함몰 영향인자 분석)

  • Jaemo Kang;Sungyeol Lee;Jinyoung Kim;Myeongsik Kong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.1
    • /
    • pp.5-11
    • /
    • 2024
  • Ground subsidence mainly occurs in urban areas with high population density, so it is necessary to clearly identify the cause of occurrence and prepare in advance. The main cause of ground subsidence is reported to be the creation of cavities in the ground due to damage to underground pipes, but the property information and influencing factors of underground pipes to predict and prepare for ground subsidence are not properly established. Therefore, in this study, factors showing a significant correlation with the occurrence of ground subsidence were selected among the underground facility property information and a regression equation was proposed through logistic regression analysis. For this purpose, data on underground structures and ground subsidence history information in the target area were collected, and the target area was divided into girds of 100m x 100m in size using QGIS. The underground facility attribute information and ground subsidence history information contained within the gird were extracted. Then, preprocessing was performed to construct a dataset and correlation analysis was performed. As a result, factors excluding the year of sewer pipes and communication pipes and the average depth of communication pipes, heat pipes, and gas pipes were found to have a significant correlation with ground subsidence. In addition, a regression equation for whether ground subsidence occurred in the target area is proposed through logistic regression analysis.

Peak seismic response of a symmetric base-isolated steel building: near vs. far fault excitations and varying incident angle

  • Pavlidou, Constantina;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • v.18 no.3
    • /
    • pp.349-365
    • /
    • 2020
  • Since the peak seismic response of a base-isolated building strongly depends on the characteristics of the imposed seismic ground motion, the behavior of a base-isolated building under different seismic ground motions is studied, in order to better assess their effects on its peak seismic response. Specifically, the behavior of a typical steel building is examined as base-isolated with elastomeric bearings, while the effect of near-fault ground motions is studied by imposing 7 pairs of near- and 7 pairs of far-fault seismic records, from the same 7 earthquake events, to the building, under 3 different loading combinations, through three-dimensional (3D) nonlinear dynamic analyses, conducted with SAP2000. The results indicate that near-fault seismic components are more likely to increase the building's peak seismic response than the corresponding far-fault components. Furthermore, the direction of the imposed earthquake excitations is also varied by rotating the imposed pairs of seismic records from 0◦ to 360◦, with respect to the major construction axes. It is observed that the peak seismic responses along the critical incident angles, which in general differ from the major horizontal construction axes of the building, are significantly higher. Moreover, the influence of 5% and 10% accidental mass eccentricities is also studied, revealing that when considering accidental mass eccentricities the peak relative displacements of the base isolated building at the isolation level are substantially increased, while the peak floor accelerations and interstory drifts of its superstructure are only slightly affected.

Tunneling-induced Building Damage Risk Assessment System (터널굴착에 따른 인접건물 손상위험도 평가시스템)

  • Park, Yong-Won;Yoon, Hyo-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2002
  • This paper deals with development of a damage risk assessment system for adjacent buildings to under-passing tunnel face considering 3D-ground movement. The system consists of building and ground information module, monitoring data module, settlement evaluation module, and building damage risk assessment module. The major modules, settlement evaluation module and building damage assessment module, are based on settlement estimation model suggested by Attewell et al (1982) and the building damage assessment method by Mair et al. (1996). After estimating 3D-ground movements due to tunneling with settlement evaluation module, damage assessment far buildings is performed using building damage risk assessment module. The developed system has two major functions; 1) calculation of 3D-settlement with ground loss ($V_{s}$)or maximum settlement ($w_{max}$) and inflection point (i) using various empirical formulae, monitoring data, numerical results, and so on; 2) assessment of damage risk for adjacent buildings of arbitrary section with position change of tunnel face. The field data given by Boscadin and Cording (1989) leer the case of two-storied masonry building near the Metro tunnel in Washington D.C. was simulated to verify the applicability of the developed system.

Duration Effect of the Ground Motion on Structures (지반거동의 지속시간이 건물에 미치는 영향)

  • 김희철
    • Computational Structural Engineering
    • /
    • v.5 no.1
    • /
    • pp.91-96
    • /
    • 1992
  • Earthquake resistant design is evolutionary, and, although great progress has been made since seismic design was made mandatory by building codes, it is still not completely understood. In this paper, a 10 story steel building is analyzed and its results are compared by applying two different actual ground motions to the structure. 12 sets of Loma Prieta, California, earthquake data which occurred in 1989, and recorded 7.1 on the Richter scale and 9 sets of Valparaiso, Chile, earthquake data which occurred in 1985, and recorded 7.8 on the Richter scale were scaled to zone 2B level of UBC-88. By applying earthquake ground motions which had similar Richter scale magnitude, it was found that the Chile earthquake which had long duration of ground motion affected about twice bigger than that of California earthquake which had relatively short duration of ground motion. In addition to the peak ground motion, the duration of the ground motion is a very important factor in structural design.

  • PDF

The Risk Evaluation of Ground Subsidence based on GIS Analysis Method (GIS 분석기법을 활용한 지반침하 위험도 평가)

  • Choi, Byoung Il;Kim, Jong Hoon;Park, Won Joo;Choi, Chang Ho;Kim, Jin Young
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.104-109
    • /
    • 2017
  • As the ground subsidence occurred at the center of Seoul area in 2014, the ground subsidence phenomenon was emerged as a social issue in Korea. Even so far, national and local governments and related experts have been making a lot of efforts to prevent ground subsidence phenomenon, but it is still happening all over the country. In this study, we chose 9 influence factors on which ground subsidence and derived weights using AHP(Analytic Hierarchy Process) method for ground subsidence risk analysis. And we analyze the risk of subsidence in ${\bigcirc}{\bigcirc}$city using GIS(Geographic Information System) analysis method and evaluate the potential risk.

Heating Performance of Geothermal Heat Pump System Applied in Cold Climate Region(Mongolia) (한랭지(몽골) 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu;Choi, Jae Ho;Min, Kyung Chon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Geothermal heat pump (GHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. These systems use the ground as a heat source in heating mode operation and a heat sink in cooling mode operation. The aim of this study is to evaluate the heating performance of the GHP system for a residential building ($420m^2$) in Ulaanbaatar, Mongolia. In order to demonstrate the feasibility of a sustainable performance of this system, we installed the water-to-water geothermal heat pump with ten vertical ground heat exchangers and measured operation parameters from October 19, 2013 to March 26, 2014. The results showed that the entering source temperature of brine from the ground heat exchangers was in a range of the design target temperature of $-10^{\circ}C$ for heating. For total values of the representative results, the ground heat exchangers extracted heat of 53.51 MWh from the ground. In addition, the GHP system supplied heat of 83.55 MWh to the building and consumed power of 30.27 MWh. Consequently, the average heating seasonal performance factor ($SPF_h$) of the overall system was evaluated to be 2.76 during the measurement period of the heating season.

Structural Design and Construction of High-rise Building to Feature the High-performance Oil Dampers for Vibration Control - Hibiya Mitsui Tower -

  • Kato, Takashi;Hara, Kenji;Tanaka, Hiroyuki
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.229-234
    • /
    • 2019
  • This report introduces the structural design of Hibiya Mitsui Tower built in Tokyo Midtown Hibiya. The upper part of this tower is used for offices and the lower portion is for commercial facilities and a cinema complex which need the large open spaces. The 192m-high building has 35 floors above ground and 4 below ground. The structure is a steel frame using CFT columns to feature the high-performance oil dampers and the buckling restrained braces for vibration control. First, an outline of the structural design of this building is presented. Second, we introduce the transfer frame adopted to realize the large open spaces in the lower part, and the long column supporting the corner part of the high-rise building to avoid making a shade on the adjacent Hibiya Park, which are the feature of this building. Finally, we present an outline of the latest highly efficient semi-active oil dampers adopted in this building, and the vibration responses of this tower.

A shake table investigation on interaction between buildings in a row

  • Khatiwada, Sushil;Chouw, Nawawi
    • Coupled systems mechanics
    • /
    • v.2 no.2
    • /
    • pp.175-190
    • /
    • 2013
  • Pounding damage has been observed frequently in major earthquakes in the form of aesthetic, minor or major structural cracks and collapse of buildings. Studies have identified a building located at one end of a row of buildings as very vulnerable to pounding damage, while buildings in the interior of the same row are assumed to be safer. This study presents the results of a shake table investigation of pounding between two and three buildings in a row. Two steel portal frames, one stiffer and another more flexible, were subjected to pounding against a frame with eight other configurations. Three pounding arrangements were considered, i.e., the reference frame (1) on the right of the second frame, (2) in the middle of two identical frames, and (3) on the right of two identical frames. Zero seismic gap was adopted for all tests. Five different ground motions are applied from both directions (right to left and left to right). The amplification of the maximum deflection due to pounding was calculated for each configuration. The results showed that, for the stiffer building in a row, row building pounding is more hazardous than pounding between only two buildings. The location of the stiffer frame, whether at the end or the middle of the row, did not have much effect on the degree of amplification observed. Additionally, for all cases considered, pounding caused less amplification for stronger ground motions, i.e., the ground motions that produced higher maximum deflection without pounding than other ground motions.

Cooling Performance of Cooling Tower-Assisted Ground-Coupled Heat Pump (GCHP) System Applied in Hospital Building (병원 건물에 설치된 냉각탑 병용 지열 히트펌프 시스템의 냉방 성능)

  • Sohn, Byonghu;Lee, Doo-Young;Min, Kyung-Chon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • This paper presents the measurement and analysis results for the cooling performance of ground-coupled heat pump (GCHP) system using a cooling tower as a supplemental heat rejector. In order to demonstrate the performance of the hybrid approach, we installed the monitoring equipments including sensors for measuring temperature and power consumption, and measured operation parameters from May 1 to October 30, 2014. The results showed that the entering source temperature of brine returning from the ground heat exchanger was in a range of design target temperature. Leaving load temperatures to building showed an average value of $11.4^{\circ}C$ for cooling season. From the analysis, the daily performance factor (PF) of geothermal heat pumps ranged from 4.4 to 5.2, while the daily PF of hybrid GCHP system varied from 3.0 to 4.0 over the entire cooling season.

Heating Performance Analysis of Building Integrated Geothermal System With Radiant Floor Heating (복사패널이 적용된 건물일체형 지열원 시스템의 난방성능 분석)

  • Jin, Shangzhen;Lee, Jin-Uk;Kim, Taeyeon;Leigh, Seung-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.25-30
    • /
    • 2012
  • Ground source heat pumps(GSHPs) are among the most efficient and comfortable heating and cooling technologies currently available, because they use the earth's natural heat to provide heating, cooling, and often, water heating. And Building Integrated Geothermal System(BIGS) is one of GSHPs which install ground heat exchanger(GHE) in energy pile without borehole to save the investment cost. Therefore, the experiment is to evaluate the heating performance of BIGS in Korea. The experimental results indicate that the average heat pump COP and overall system's COP values are approximately 4.4 and 3.0 in one week. This study shows that the BIGS could be used for heating in Korea.