• 제목/요약/키워드: ground building

검색결과 1,653건 처리시간 0.023초

순환골재 세척수를 혼입한 고로슬래그 콘크리트의 압축강도 특성에 관한 실험적 연구 (An Experimental Study on the Compressive Strength Property of Concrete with Ground granulated Blast Furnace Slag Using Wash Water from Recycled Aggregates)

  • 정상경;신상엽;김영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.34-35
    • /
    • 2015
  • The purpose of this study is to investigate the compressive strength property of concrete with Ground granulated blast furnace slag(GBFS) using wash water from recycled aggregate. When GBFS is reacted with water, it doesn't happen to hydraulic reaction but GBFS becomes latent hydraulic property in alkaline environment. For this reason, if it is possible to use wash water from recycled coarse aggregate as mixture water, GBFS have the advantage of early strength due to effect of activation. We investigated the compressive strength properties of GBFS concrete using wash water from recycled aggregate. According to the experimentation result, ICP-OES showed wash water from recycled coarse aggregate has a high alkali value of pH of 12. Also, compressive strength in early age using wash water can be improved as an activation.

  • PDF

도심지 변전소 지락사고시 인근 저항성간섭 영향 해석 (Analysis of Conductive Interference Around Substation Exclusively Fed by Cables Under Ground Fault Condition)

  • 최종기;이동일;김재준;유연표;정창수;김경철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권12호
    • /
    • pp.592-596
    • /
    • 2005
  • Recently, substations have been constructed in GIS (Gas Insulated Switchgear) and indoor type because of the increasing difficulties of securing locations. In case of urban substations, it is also common that the substations are exclusively fed by underground cables. Sometimes, the infrastructures in urban area, such as communication facilities, are located near substations to be constructed. In this paper, we examined such a case that a branch office building of KT(Korea Telecom) was located near 154 kV underground GIS substation under construction with about 100 meters of the lateral distance between two facilities. GPR (Ground Potential Rise) at the substation and the transferred earth potential at the KT building through the earth in SLG (Single-Line-to- Ground) fault condition were investigated based on a series of computer simulations. The calculated earth potential at a distance of 100 m from the substation was below 120 V which satisfying the limit value of 650 V.

국제 표준(IEC)에 의한 접지 설계 및 이에 대한 안전성 분석·평가 (Design and A Safety Analysis and Assessment of a Grounding System according to International Standards)

  • 김두웅;조만형;김한수;신대성;류기환;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.54-59
    • /
    • 2015
  • In this paper, we evaluate safety of grounding system which is designed according to IEC standards. Safety assessment of construction site and grounding system of building is needed before construction for the safety of human in building. Until now, in case of domestic field, design of grounding system is proceeded based on methods which are proposed in IEEE Std. 80. In other words, it is not in the situation that grounding system is designed based on IEC standards. Therefore, we propose a method which designs grounding system and evaluates safety of it according to IEC standards. We measure ground resistance of construction site using measuring equipment of ground resistance. Using this value, soil structure and ground resistivity are obtained through program analysis. CDEGS program of SES company is used for simulation analysis.

지반굴착에 소요되는 전기식모터의 전류저항값 변화에 관한 연구 (A Study of Change in Current Resistance Value of Electric Motor Requied for Ground Dilling)

  • 서동남;정상훈;이상현;신진섭;최상호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.385-386
    • /
    • 2023
  • In this application study, field pilot tests were performed to evaluate the validity of a proposed formula between the exerted electrical energy and SPT N-value based on the result of the basic study. Measurement sensors and recording system were developed to obtain exerted motor current and drilling depth in a field. By using the correlation formula proposed in the basic study, the measured motor current and boring speed were applied to predict SPT N-value and the predicted N-values were compared to SPT N-value of site exploration. From the comparisons it is verified that the exerted electrical energy to bore ground might be used to predict SPT N-value and pile tip location.

  • PDF

철근콘크리트 대용접지극에 관한 기초 연구 (Foundation Research for Reinforced Concrete Substitution Grounding Electrode)

  • 김성삼;이충식;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.305-308
    • /
    • 2004
  • There are ground facility of maintenance in house electric facility of infra maintenance electric home appliances having used multifariousness in house, that use electric energy of common source for equipment. The body of building such as the reinforced concrete construction is structurally united, and the electric resistance is also small. It is possible that those foundations have contacted the ground at large surface area and that it substitutes the building construction body for the earth electrode. This is called "the structure earthing". This method has been defined at electrical facilities technical standards and KS in our country, and it has been used in various quarters practically. However, in our country, there is no example of using the foundation of the house as substitution earth electrode practically, and the means of the evaluation as electrode has not been established either. Then, in this paper, basic research for utilizing foundation of the house as substitution earth electrode is carried out.

  • PDF

Seismic fragility evaluation of piping system installed in critical structures

  • Ju, Bu Seog;Jung, Woo Young;Ryu, Yong Hee
    • Structural Engineering and Mechanics
    • /
    • 제46권3호
    • /
    • pp.337-352
    • /
    • 2013
  • Seismic performance of critical facilities has been focused on the structural components over the past decade. However, most earthquake damages were observed to the nonstructural components during and after the earthquakes. The primary objective of this research was to develop the seismic fragility of the piping system incorporating the nonlinear Tee-joint finite element model in the full scale piping configuration installed in critical facilities. The procedure for evaluating fragility curves corresponding to the first damage state was considered the effects of the top floor acceleration sensitivities for 5, 10, 15, and 20 story linear RC and steel building systems subjected to 22 selected ground motions as a function of ground motion uncertainties. The result of this study revealed that the conditional probability of failure of the piping system on the top floor in critical facilities did not increase with increased level of story height and in fact, story level in buildings can tune the fragilities between the building and the piping system.

철골세우기의 현장생산성 측정 및 영향요인 분석 (Productivity Measurement and Analysis on Factors in Steel Erection)

  • 이지용;허영기;안방률
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.123-127
    • /
    • 2008
  • As buildings becoming higher and more enormous the portion of steel works has been increased, which makes the schedule planning and management more significant. However, in actual construction sites, management is more based on a manager's construction experience than productivity data accumulated in previous projects. Moreover, most of the existing studies also featured a theoretical approach rather than an analysis of data straightforwardly collected in sites. In this study, a steel-erection site was visited to collect productivity data. The study found that there were significant disparities between aboveground work productivity and underground work. However, the productivities of 'first node on ground' and 'second node on ground' were estimated similar. The productivity data collected and factors affecting the productivity will help managers to plan and control their similar steel-erection works. This study will also be beneficial for those performing related studies.

  • PDF

저유동성 몰탈형 주입재에 의한 건물기초보강 (Reinforcement of Building Foundation by the Low Slump Mortar Grout)

  • 천병식;고용일;권형석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.71-76
    • /
    • 2000
  • In generally, grouting consists of injecting a suspension or solution into the voids of soils. The low slump mortar grout has been used in America since 1950's. The Compaction Grouting, the injection of a very stiff under relatively high pressure, form a cylinderical grout support pile. The grout generally does not enter soil pores but remains in homogeneous mass that gives controlled displacement either to compact loose soils, or for lifting of structures, or both. In this paper, on the case of the reinforcement construction of 00 plant that the foundation's bearing capacity is insufficient and is to reinforce the foundation, a study has been peformed to analyze the effectiveness of the ground improvement. The bearing capacity of the Compaction Pile has been verified by the S.P.T and the settlement of the improved ground has been monitored rising the magnetic extensometer.

  • PDF

대형 건설프로젝트 현장관리를 위한 복합센서의 필수기능 분석 (Analysis of Essential Function of Composite Sensor for the Ground Work of a Large Construction Project)

  • 조남석;김창원;조대구;조훈희;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.39-40
    • /
    • 2012
  • Construction IT convergency proposes advanced management abilities of a construction project. Sensing data provided by various sensor technologies can be utilized for diverse management areas. This study analyzes required functions of sensors for implementing time, cost, safety and quality management, focusing on the ground works including excavation, pipe installation, retaining wall etc. Therefore, this study first generates essential management areas, analyzes cutting-edge sensor technologies appropriated for the areas, and finally proposes a matrix system that represents relationships between the management areas and sensor technologies, The proposed system is expected to reinforce construction management abilities by integrating sensor technologies.

  • PDF

Investigation of blast-induced ground vibration effects on rural buildings

  • Oncu, Mehmet Emin;Yon, Burak;Akkoyun, Ozgur;Taskiran, Taha
    • Structural Engineering and Mechanics
    • /
    • 제54권3호
    • /
    • pp.545-560
    • /
    • 2015
  • In this paper, blast-induced vibration effects on buildings located in rural areas were investigated. Damages to reinforced concrete, adobe and masonry buildings were evaluated in Çatakk$\ddot{o}pr\ddot{u}$ and Susuz villages in Silvan district of Diyarbakir, Turkey. Blasting of stiff rocks to construct highway at vicinity of the villages damaged the buildings seriously. The most important reason of the damages is lack of engineering services and improper constructed buildings according to the current building design codes. Also, it is determined that, inappropriate blast method and soft soil class increased the damages to the buildings. The study focuses on four points: Blast effect on buildings, soil conditions in villages, building damages and evaluation of damage reasons according to the current Turkish Earthquake Code (TEC).