• 제목/요약/키워드: grid connected PWM inverter

검색결과 76건 처리시간 0.026초

순시직전류(瞬時直電流) 추종제어형(追從制御形) Inverter의 태양광발전(太陽光發電) 시스템에의 응용(應用) (Application of Instantaneous sinusoidal current tracking control inverter for photovoltaic system)

  • 유권종;정명웅;송진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.372-375
    • /
    • 1990
  • A sinusoidal PWM type inverter using 1GBT and a new instantaneous current tracking control stategy is described. Its utilization as an interface for a grid-connected photovoltaic system with maxmum power tracking capability is explaned, and competer simulation along with waveforms are discussed. Finally, experimental results are analysed by state space avarge method to actual grid-connected systems.

  • PDF

전력 이론을 이용한 계통연계 PWM 인버터 시스템의 성능 개선 (Performance Improvement of a Grid-connected PWM Inverter using a Power Theory)

  • 정해광;이교범;강신일;이현영;권오정;송승호
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.319-327
    • /
    • 2008
  • 3상의 PWM 인버터는 풍력발전설비에서 계통연계나 전력제어의 목적으로 그 수요가 급증하고 있다. 이러한 인버터는 스위칭에 의한 고조파를 저감하기 위하여 L-필터나 LCL-필터를 통하여 계통과 연결된다. LCL-필터는 L-필터에 비하여 낮은 스위칭 주파수의 고조파도 효율적으로 저감할 수 있으며 비교적 적은 인덕턴스로 만족할 만한 수준의 계통 전류를 생성한다. 하지만 LC의 추가로 인해 생기는 추가 극점이 시스템의 공진을 초래하여 안정성 문제에 영향을 미친다. 본 논문에서는 전력이론을 이용하여 설계된 LCL필터 시스템의 성능향상과 공진에 의한 안정성 문제의 개선기법을 제안한다. 시뮬레이션과 실험결과를 바탕으로 개선기법의 타당성을 보인다.

변조지수에 따른 공통모드 전압 저감 PWM 기법 성능 비교 (Performance Comparison of Common-Mode Voltage Reduction PWM Methods in Terms of Modulation Index)

  • 허건;박용순
    • 전력전자학회논문지
    • /
    • 제26권2호
    • /
    • pp.135-140
    • /
    • 2021
  • This study introduces a new pulse width modulation (PWM) method to reduce common-mode voltages (CMVs) and then compares its performance with other reduced CMV-PWM (RCMV-PWM) methods. CMVs should be reduced to ensure the electromagnetic compatibility and safety of grid-connected inverters. RCMV-PWM methods attempt to synthesize voltage references without zero vectors, which cause high CMV peaks. In these methods, the peak-to-peak magnitude of CMVs can be reduced by one-third of the conventional space-vector PWM. The introduced method splits every reference vector into two vectors to avoid the use of zero vectors. The performances of the RCMV-PWM methods are analyzed in accordance with the modulation index through simulation and experiment.

계통 연계형 3-레벨 인버터 시스템을 위한 LCL-필터 설계 방법 (Design of an LCL-Filter for Grid-Connected Three-Level Inverter System)

  • 박준영;김석민;서승규;박성수;이교범
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.105-114
    • /
    • 2017
  • 본 논문은 계통 연계형 3-레벨 인버터 시스템을 위한 LCL-필터 설계 방법을 제안한다. 최근 풍력 및 태양광과 같은 신재생에너지 발전 시스템을 위한 3상 PWM 인버터의 수요가 증가하고 있다. 이러한 PWM 인버터는 스위칭 동작에 의해 발생하는 고조파 성분을 제거하기 위하여 LCL-필터를 거쳐 계통과 연결된다. 필터 설계에 관한 다양한 연구가 진행되었지만 최소의 사이즈로 목표하는 고조파 제거 성능을 얻기 위해서는 해당 PWM 인버터의 스위칭 방법을 고려한 필터 설계 방법이 요구된다. 본 논문은 공간 전압벡터 변조기법(SVPWM)에 최적화된 LCL-필터 설계방법을 제시한다. 시뮬레이션과 실험 결과를 통해 제안하는 방법으로 설계된 LCL-필터의 성능을 검증한다.

Current Harmonics Rejection and Improvement of Inverter-Side Current Control for the LCL Filters in Grid-Connected Applications

  • Xu, Jinming;Xie, Shaojun;Zhang, Binfeng
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1672-1682
    • /
    • 2017
  • For grid-connected LCL-filtered inverters, the inverter-side current can be used as the control object with one current sensor for both LCL resonance damping and over-current protection, while the grid-voltage feedforward or harmonic resonant compensator is used for suppressing low-order grid current harmonics. However, it was found that the grid current harmonics were high and often beyond the standard limitations with this control. The limitations of the inverter-side current control in suppressing low-order grid current harmonics are analyzed through inverter output impedance modeling. No matter which compensator is used, the maximum magnitudes of the inverter output impedance at lower frequencies are closely related to the LCL parameters and are decreased by increasing the control delay. Then, to improve the grid current quality without complicating the control or design, this study proposes designing the filter capacitance considering the current harmonic constraint and using a PWM mode with a short control delay. Test results have confirmed the limitation and verified the performance of the improved approaches.

병렬연결을 이용한 계통연계형 태양광 전류형 인버터에 관한 연구 (A Study on Grid-connected Photovoltaic Current-Source Inverter using Parallel Connection)

  • 임정민;정의현;문채주;장영학;김의선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1222-1223
    • /
    • 2007
  • This paper suggests a 6-pulse-shift converter with PWM current-source inverter based on buck-boost configuration to improve the efficiency and to reduce the switching frequency of inverter for photovoltaic generation system, the device can be operated as interface system between solar module system and power system grid without energy storage cell. the circuit has six current-source buck-boost converter which operate chopper part has one full bridge inverter which make a decision the polarity of AC output. Therefore, the proposed PWM power inverter has advantages such as the reduction of witching loss and realization of unity power factor operation. the theoretical backgrounds are discussed and the input-output characteristics for the implemented prototype inverter using TMS320F2812 are verified experimentally in this paper.

  • PDF

고주파링크방식을 이용한 PV용 PCS의 고찰 (High-Frequency DC Link Inverter for Grid-Connected Photovoltaic System)

  • 정영석;유권종;정명웅;최재호;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1313-1315
    • /
    • 2002
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency inverter bridge, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter bridge, and an AD filter. The high frequency inverter bridge switching at 20kHz is used to generate bipolar PWM pulse, which is subsequently rectified by diode bridge rectifiers to result in a full-wave rectified sine wave. Finally, it is unfolded by a low frequency inverter bridge to result in a 60Hz sine wave power output. In this paper, the control algorithm for synchronous current feedback control method and a maximum power point tracking (MPPT) method using DSP are described. And, the simulation and experimental results are shown to verify the validity of the proposed system.

  • PDF

LCL 필터를 사용하는 계통연계형 인버터의 동기좌표계 PI 전류제어 안정도 해석 (Analysis of Current Control Stability using PI Control in Synchronous Reference Frame for Grid-Connected Inverter with LCL Filter)

  • 조종민;이태진;윤동현;차한주
    • 전력전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.168-174
    • /
    • 2016
  • In this paper, current control using PI controller in the synchronous reference frame is analyzed through the relationship among bandwidth, resonance frequency, and sampling frequency in the grid-connected inverter with LCL filter. Stability is investigated by using bode plot in frequency domain and root locus in discrete domain. The feedback variable is the grid current, which is regulated by the PI controller in the synchronous reference frame. System delay is modeled as 1.5Ts, which contains computational and PWM modulator delay. Two resonance frequencies are given at 815 Hz and 3.16 kHz from LCL filter parameters. Sufficient phase and gain margins can be obtained to guarantee stable current control, in case that resonance frequency is above one-sixth of the sampling frequency. Unstable current control is performed when resonance frequency is below one-sixth of the sampling frequency. Analysis results of stability from frequency response and discrete response is the same regardless of resonance frequency. Finally, stability of current control based on theoretical analysis is clearly verified through simulation and experiment in grid-connected inverters with LCL filter.

계통연계 태양광발전시스템의 제어기법 및 연계운전특성 (A control method and test results of utility interactive photovoltaic power generation systems)

  • 안교상;임희천;황인호;주형준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.549-553
    • /
    • 1999
  • This paper describes a design method of grid-connected photovoltaic power generation systems with three phase inverter. A 3-phase 50kW photovoltaic power generation system including a DC/AC inverter is designed and made in order to investigate the system performance for grid connection. Also the control scheme of a three phase current-controlled PWM inverter is presented by using d-q transformation. The experimental waveforms show that the proposed system has stable behavior with an unit power factor in utility-interactive operation.

  • PDF

계통연계 태양광발전시스템의 제어기법 및 연계운전특성 (A Control Method and Test Results of Utility-Interactive Photovoltaic Power Generation Systems)

  • 황인호;안교상;임희천;김신섭
    • 전력전자학회논문지
    • /
    • 제5권2호
    • /
    • pp.123-129
    • /
    • 2000
  • 본 논문은 실용화 보급단계에 있는 대표적인 대체에너지 전원으로서, 태양전지, 직·교류(DC/AC) 인버터, 전력계통으로 구성되는 계통연계형 태양광발전시스템의 설계 및 시험결과에 대하여 기술하고자 한다. 계통연계를 위한 시스템 특성을 검증하기 위해 3상 직·교류 인버터를 포함한 50kW 계통연계 태양광발전시스템이 설계 제작되었다. 또한 d-q 변환을 이용한 PI 제어기를 갖는 전류제어방식의 3상 PWM 인버터 제어기법이 제시되었다. 실험결과들은 제안된 시스템이 계통연계 동작에 있어서 단위 역율로 안정하게 동작함을 보여준다.

  • PDF