• 제목/요약/키워드: grid analysis

검색결과 2,826건 처리시간 0.032초

중첩 격자 기법을 이용한 지면 효과를 받는 RAE 101 익형의 공력 해석 (AERODYNAMICS OF THE RAE 101 AIRFOIL IN GROUND EFFECT WITH THE OVERLAPPED GRID)

  • 이재은;김윤식;김유진;권장혁
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.193-198
    • /
    • 2006
  • It takes a lot of time and effort to generate grids for numerical analysis of problems with ground effect because the relative attitude and height of airfoil should be maintained to the ground as well as the inflow. A low Mach number preconditioned turbulent flow solver using the overlap grid technique has been developed and applied to the ground effect simulation. It has been validated that the present method using the multi-block grid gives us highly accurate solutions comparing with the experimental data of the RAE 101 airfoil in an unbounded condition. Present numerical method has been extended to simulate ground effect problems by using the overlapped grid system to avoid tedious work in generating multi-block grid system. An extended method using the overlapped grid has been verified and validated by comparing with results of multi-block method and experimental data as well. Consequently, the overlapped grid method can provide not only sufficiently accurate solutions but also the efficiency to simulate ground effect problems. It is shown that the pressure and aerodynamic centers move backward by the ground effect as the airfoil approaches to the ground.

  • PDF

An Optimization Method for the Calculation of SCADA Main Grid's Theoretical Line Loss Based on DBSCAN

  • Cao, Hongyi;Ren, Qiaomu;Zou, Xiuguo;Zhang, Shuaitang;Qian, Yan
    • Journal of Information Processing Systems
    • /
    • 제15권5호
    • /
    • pp.1156-1170
    • /
    • 2019
  • In recent years, the problem of data drifted of the smart grid due to manual operation has been widely studied by researchers in the related domain areas. It has become an important research topic to effectively and reliably find the reasonable data needed in the Supervisory Control and Data Acquisition (SCADA) system has become an important research topic. This paper analyzes the data composition of the smart grid, and explains the power model in two smart grid applications, followed by an analysis on the application of each parameter in density-based spatial clustering of applications with noise (DBSCAN) algorithm. Then a comparison is carried out for the processing effects of the boxplot method, probability weight analysis method and DBSCAN clustering algorithm on the big data driven power grid. According to the comparison results, the performance of the DBSCAN algorithm outperforming other methods in processing effect. The experimental verification shows that the DBSCAN clustering algorithm can effectively screen the power grid data, thereby significantly improving the accuracy and reliability of the calculation result of the main grid's theoretical line loss.

터보기계 익렬유동해석을 위한 다중블록 격자형성법 (Multiblock Grid Generation for Turbomachinery Cascade-Flow Analysis)

  • 정희택
    • 한국전산유체공학회지
    • /
    • 제1권1호
    • /
    • pp.19-25
    • /
    • 1996
  • A multiblock grid generation has been developed to be reliably used for a Navier-Stokes simulation of the turbomachinery flow-fields A multiblock structure simplifies the creation of structured H-grids about complex turbomachinery geometries and facilitate the creation of a grid in the tip flow region. The numerical algorithm adopts the combination of the algebraic and elliptic method to create the internal grids efficiently and quickly. The grid refinement process is enhanced by developing strategies to utilized Bezier curves and splines along with weighted transfinite interpolation technique and by formulating the grid-imbedding method for the viscous boundary-layer meshes. For purposes of illustration, the grid generator is applied to the high turning turbine rotor blades. Two different types of computational grids are provided to be compared with respect to the grid adaptation to the flow simulations. Extension to three-dimensions was done to show the possibility of its application to the tip-flow simulations. The grid quality of the multiblock structure is good in the passages, with gloval orthogonality and adequate smoothness.

  • PDF

분포형 유출모형을 이용한 홍수유출해석 (Flood Runoff Analysis using a Distributed Rainfall Runoff Model)

  • 조홍제;조인률
    • 한국수자원학회논문집
    • /
    • 제31권2호
    • /
    • pp.199-208
    • /
    • 1998
  • 유역의 지형특성에 근거를 두고 유출기여면적의 변화를 고려한 분포형 모형인 TOPMODEL을 이용하여 홍수유출해석에 대한 적용성을 연구하였다. 건설교통부에서 설치운영중인 위천대표시험유역의 소유역인 동곡 및 고로지점을 분석대상유역으로 선정하였으며, 1/25,000 지형도를 이용하여 수치고도지도를 작성하였고 지형인자분석은 지리정보 시스템 도구인 Arc/Info를 이용하였다. 두 소유역의 지형상수가 서로 비슷하였고 각 연도별 동일호우사상에 대한 모형매개변수도 서로 유사한 특성을 나타내었다. TOPMODEL을 이용한 홍수유출에 대한 첨두유량의 모의 결과는 관측치와 비교할 때 그 재현성이 매우 우수하였다. 격자의 크기별로 유역을 분할하고 그에 따른 첨두유량과 발생시각의 변화를 동곡소유역은 100,120,240m, 고로유역은 120,200,360m 격자로서 분석한 결과 두 유역 모두 격자 크기의 증가에 따라 첨두유량은 증가하고 발생시각은 격자의 크기와 관계없이 일정한 것으로 나타났다.

  • PDF

Resonance Characteristics Analysis of Grid-connected Inverter Systems based on Sensitivity Theory

  • Wu, Jian;Han, Wanqin;Chen, Tao;Zhao, Jiaqi;Li, Binbin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.746-756
    • /
    • 2018
  • Harmonic resonance exists in grid-connected inverter systems. In order to determine the network components that contribute to harmonic resonance and the composition of the resonant circuit, sensitivity theory is applied to the resonance characteristic analysis. Based on the modal analysis, the theory of sensitivity is applied to derive a formula for determining the sensitivities of each network component parameter under a resonance circumstance that reflects the participation of the network component. The solving formula is derived for both parallel harmonic resonance and series harmonic resonance. This formula is adopted to a 4-node grid-connected test system. The analysis results reveal that for a certain frequency, the participation of parallel resonance and series resonance are not the same. Finally, experimental results demonstrate that the solving formula for sensitivity is feasible for grid-connected systems.

New Backstepping-DSOGI hybrid control applied to a Smart-Grid Photovoltaic System

  • Nebili, Salim;Benabdallah, Ibrahim;Adnene, Cherif
    • International Journal of Computer Science & Network Security
    • /
    • 제22권4호
    • /
    • pp.1-12
    • /
    • 2022
  • In order to overcome the power fluctuation issues in photovoltaic (PV) smart grid-connected systems and the inverter nonlinearity model problem, an adaptive backstepping command-filter and a double second order generalized Integrators (DSOGI) controller are designed in order to tune the AC current and the DC-link voltage from the DC side. Firstly, we propose to present the filter mathematical model throughout the PV system, at that juncture the backstepping control law is applied in order to control it, Moreover the command filter is bounded to the controller aiming to exclude the backstepping controller differential increase. Additionally, The adaptive law uses Lyapunov stability criterion. Its task is to estimate the uncertain parameters in the smart grid-connected inverter. A DSOGI is added to stabilize the grid currents and eliminate undesirable harmonics meanwhile feeding maximum power generated from PV to the point of common coupling (PCC). Then, guaranteeing a dynamic effective response even under very unbalanced loads and/or intermittent climate changes. Finally, the simulation results will be established using MATLAB/SIMULINK proving that the presented approach can control surely the smart grid-connected system.

경사도 분석에 적용하는 단위격자크기가 골프장의 입지 평가에 미치는 영향 분석(환경적 측면에서) (Analysis of the Effect on the Location Evaluation of Golf Course according to the Unit Grid Size applied in the Slope Analysis(In flank of Environment))

  • 엄대용;이병수
    • 한국측량학회지
    • /
    • 제30권5호
    • /
    • pp.467-475
    • /
    • 2012
  • 본 연구에서는 골프장 건설사업에 대한 사전환경성 검토과정에서 입지 및 환경 영향성을 평가하기 위해 실시하는 지형의 경사도 분석에 적용되는 단위 격자크기에 따라 상이한 입지평가 결과가 도출되는 문제점에 대하여 조사 분석하였다. 이를 위해 환경성 사전 협의를 통과하여 현재 공사가 진행 중이거나 협의가 진행 중인 12개 골프장을 대상으로 단위격자 크기의 변화에 따른 경사도 비율의 변화를 분석함으로써 실제 지형을 정확히 반영할 수 있는 단위 격자크기를 분석하였다. 그리고 연구대상 골프장 사업지에 대하여 도출된 단위 격자크기를 적용하여 환경성 평가의 협의 가능 여부를 재검증하였다. 연구결과, 경사도의 분석을 위해 설정한 단위 격자크기가 커질수록 경사도가 높은 구역의 경사도 비율이 저평가됨을 확인할 수 있었으며, 본 연구의 설정 중 $5m{\times}5m$의 격자크기를 적용하였을 경우가 실제 지형에 가장 근접하는 분석결과를 도출할 수 있었으므로 이를 환경부에 건의하여 경사도 분석을 위한 단위 격자크기의 기준을 $5m{\times}5m$로 개정할 수 있도록 하였다. 더불어 본 연구에서 제안한 단위격자 크기를 적용하여 연구대상 골프장에 대한 경사도 비율을 재분석할 경우, 4개소의 골프장이 관련 규정의 협의기준을 초과하는 것으로 분석되어 환경적 측면에서 골프장 입지로서 부적절한 입지임을 입증할 수 있었다.

Comparative Analysis of Centralized Vs. Distributed Locality-based Repository over IoT-Enabled Big Data in Smart Grid Environment

  • Siddiqui, Isma Farah;Abbas, Asad;Lee, Scott Uk-Jin
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2017년도 제55차 동계학술대회논문집 25권1호
    • /
    • pp.75-78
    • /
    • 2017
  • This paper compares operational and network analysis of centralized and distributed repository for big data solutions in the IoT enabled Smart Grid environment. The comparative analysis clearly depicts that centralize repository consumes less memory consumption while distributed locality-based repository reduce network complexity issues than centralize repository in state-of-the-art Big Data Solution.

  • PDF

계통연계형 PMSG 풍력발전시스템의 LVRT 동작 분석을 위한 하드웨어 시뮬레이터 (Hardware Simulator for LVRT Operation Analysis of Grid-Tied PMSG Wind Power System)

  • 이재욱;김재혁;최영도;한병문;윤영두
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1219-1226
    • /
    • 2014
  • This paper introduces a hardware simulator for the LVRT operation analysis of the grid-tied PMSG wind power system with a power dissipation circuit. The power dissipation circuit, which is composed of chopper and resistor, suppresses the sudden increase of DC-link voltage in the back-to-back converter of the grid-tied PMSG wind power system. The LVRT operation was first analyzed using computer simulations with PSCAD/EMTDC. A wind power simulator including the power dissipation circuit and the fault simulator composed of variac and IGBT were built to analyze the LVRT operation. Various experiments were conducted to verify the effectiveness of the power dissipation circuit for the LVRT operation. The developed hardware simulator can be extensively utilized for the analysis of various LVRT operations of the grid-tied wind power system.

계통연계형 직렬운전 소형풍력발전시스템의 해석 및 운전방안 연구 (The Analysis and Study on Operation Strategy of Grid-connected Series Small Wind Turbine System)

  • 김창하;구현근;손영득;김장목
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.59-64
    • /
    • 2015
  • This paper proposes an analysis and operation strategy of a grid-connected wind turbine system using a diode rectifier. The currents of generators are the same as that of a small wind turbine system. Therefore, the analysis of generator torque is required as opposed to an analysis of blade speed. In this paper, the appropriate MPPT control method is proposed to control generator torque. Usefulness of the proposed operation strategy is verified by simulations and experiments.