• 제목/요약/키워드: green globe

검색결과 25건 처리시간 0.029초

Role of tea catechins in prevention of aging and age-related disorders

  • Khanna, Arjun;Maurya, Pawan Kumar
    • 셀메드
    • /
    • 제2권1호
    • /
    • pp.2.1-2.11
    • /
    • 2012
  • Tea polyphenols especially catechins have long been studied for their antioxidant and radical scavenging properties. Scientists throughout the world have investigated the usefulness of the regular green tea consumption in several disease conditions. In-vitro and in-vivo experiments on catechins especially epigallocatechingallate have revealed a significant role in many ways. Reactive oxygen species have been increasingly implicated in the pathogenesis of many diseases and important biological processes. Toxic effects of these oxidants, commonly referred to as oxidative stress, can cause cellular damage by oxidizing nucleic acids, proteins, and membrane lipids. Oxidative stress has been related to aging and age related disorders. It is found that in a wide variety of pathological processes, including cancer, atherosclerosis, neurological degeneration, Alzheimer's disease, ageing and autoimmune disorders, oxidative stress has its implications. Catechins have been reported to be useful in combating aging and age related disorders like cancer, cardiovascular disorders and neurodegenerative diseases. In this mini review we will discuss such studies done across the globe.

바닥공조 시스템이 적용된 사무공간의 거주후 성능평가 (Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System)

  • 윤성훈;장향인;정해권;최선규;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

주거지역 종세분화에 따른 주거환경 개선에 관한 연구 - 바람길을 중심으로 - (A study of Improvement for Residential Environment according to Segementation of Residential Zoning)

  • 김대욱;정응호;류지원;차재규;이준영
    • 한국주거학회논문집
    • /
    • 제21권2호
    • /
    • pp.101-109
    • /
    • 2010
  • Various environmental problems due to rapid industrialization and urbanization have worsened to such an extent that they threaten the environmental restitution of the globe and become a critical international issue. Korean government has presented the concept of green growth as a new state vision for the next 60 years and is making efforts to solve these environmental problems. Daegu Metropolitan City has faced various environmental problems including overpopulation of the city, traffic pollution, household waste accumulation and the green zone problem because of the increase of urbanization over the last few decades. As such urbanization continues, the quality of residential environments is rapidly deteriorating and the intensive use of the land leads to an increase of building area, raising the temperatures of cities. There have therefore been demands for healthy, pleasant and satisfying residential environments and for the improvement of existing residential environments, and this demand has been fully recognized by society. Nevertheless, current residential complex developments concentrate only on raising the efficiency of land use. In related laws of the past (Daegu Metropolitan City, Urban Planning Municipal Ordinance as of October 10, 2003) an attempt was made to impose a standard to segmentalize the building-to-land ratio, floor area ratio and regulations of number of floors vertically. However, these laws have now been abolished and the regulations are being eased. The purpose of this study was to analyze the characteristics of the floating wind before and after the vertical segmentation of residential areas (Daegu Metropolitan City, Urban Planning Municipal Ordinance as of October 10, 2003) by using KLAM_21, a model that enables analysis and prediction of the flow and generation of cold wind. The purpose is also to present a plan to improve the quality of residential areas when developing a building lot and redeveloping housing areas.

주거지역 종세분화에 따른 바람환경 분석 (An Analysis of Wind environment on the Basis of reclassified Zoning)

  • 이준영;정응호;김대욱;차재규
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.109-112
    • /
    • 2009
  • Various environmental problems due to the rapid industralization and urbanization have been worsened as much as to threaten the environmental restitution of globe and become a critical international issue. Korean government presented the green growth as a new state vision for 60 years afterwards and is making efforts to solve the environmental problems. Daegu metropolitan city has faced various environmental problems including overpopulation of cities, traffic pollution, household wastes and green zone problem because of urbanization for the last decades. As such urbanism continues, the quality of residential environment is rapidly deteriorating and the intensive use of land leads to increase of building area raising the temperature of cities. Therefore there have been demands for the healthy, pleasant and satisfying residential environment and the improvement of residential environment and such recognition rises from society in full measure. Nevertheless the current residential complex concentrates only on raising the efficiency of land use. Related laws in the past(Daegu Metropolitan City, Urban Planning Municipal Ordinance as of October 10, 2003) tried to prepare a standard to segmentalize the building-to-land ratio, floor area ratio and regulations of number of floors vertically, but currently it is abolished and the regulations are becoming eased. The purpose of this study was to analyze the characteristics of the floating wind before and after the vertical segmentation of residential areas(Daegu Metropolitan City, Urban Planning Municipal Ordinance as of October 10, 2003) by using KLAM_21, a model that enables analysing and predicting the flow and generation of clod wind, and to present a plan to improve the quality of residential areas afterwards when developing building lot and re-developing housing areas.

  • PDF

도시의 기온 분석을 통한 지역별 열 환경 특성 해석과 동·하절기 계절 간 비교연구 (Comparison Study on Thermal Environment Characteristics in Each Region and the Seasons of Summer and Winter Through Air Temperature Analysis in Urban Areas)

  • 최동호;이부용
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.83-93
    • /
    • 2012
  • This study is to perform the effect of urbanization in urban and suburban districts, and to identify regional characters of climate according to the analysis of slope at rise, and descent of temperature and globe temperature, correlation between seasonal temperature analysis, and calculation of degree hour. According to this study, the result is summarized as follows. (1) The average temperature, rated from high to low, consists of residential area, Daegu weather station, intracity, green belt, water-front green belt, and suburban. (2) At the rise and descent of temperature, the result of the slope change of in each point may be one of the useful indexes to be able to perform the regional unique thermal characteristic, including the seasonal urbanization. (3) Although there is a difference between the surface of the earth and ambient environment. The result of the correlation of temperature between summer and winter is that temperature slope in urban districts was higher than in suburban districts, and the difference of slope was unvaried among the four observations in the same city region. (4) To show objectively, regional thermal characteristics in urban and suburban districts, the exponentiation of winter degree hour and summer degree hours were checked. The result of the exponentiation is that the more artificial a region, the lower index.

유역 평가 기준 개발을 위한 그린빌딩 평가 시스템의 물관리 관련 항목 비교 연구 (Comparing Water Management Categories of Green Building Rating Systems for Development of Evaluation Criteria of Watersheds)

  • 무하마드 빌랄 이드리스;이진영;안재현;김태웅
    • 대한토목학회논문집
    • /
    • 제38권6호
    • /
    • pp.1013-1020
    • /
    • 2018
  • 급속한 산업화와 인구증가에 따라 많은 사람들이 도시에서 살기 위해 이동하고 있다. 이러한 도시화는 건설 및 개발 활동에 따라 도심지내 불투수성 면적을 증가시키며, 이로 인해 지하수위가 낮아지고 유역내 첨두홍수량이 커지며 토양유실이 증가한다. 토양과 수자원을 보전하기 위해서 전세계적으로 유역 관리 사업이 시행되고 있다. 따라서 토양 및 수자원의 보전기술을 활용하여 전체 유역에 대하여 평가하는 것이 바람직하다. 본 연구에서는 한국, 대만 및 필리핀의 녹색건물인증제도(GBRS)의 물관리 관련 항목에 대하여 논의하였다. 또한 G-SEED(한국), BERDE(필리핀), EEWH(대만)의 용수관리 기술의 평가기준을 적용하고 비교하였다. 본 연구의 결과는 포괄적인 유역평가 시스템 개발에 활용될 것으로 기대된다. 정량적인 유역평가기준은 미래의 수자원 관련 잠재적 위험도를 파악하고 보다 효율적이고 효과적으로 대응할 수 있을 것으로 판단된다.

고체전해질을 사용한 $CO_2$가스센서의 응답기구 (Characteristics of Solid Electrolyte $CO_2$ Gas Sensors)

  • 김귀열;박용필;이성일;이원재;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.562-564
    • /
    • 2002
  • In recent years, environments of our globe has been getting worse as a result of rapid growth of socioeconomic activities. The global environmental issues of acid rain, green house effect and ozone depletion are caused by various chemical pollutants, emitted from industries, automobiles and home. Most of these pollutants are produced by combustion processes. CO2 as a chief criminal of the greenhouse effect is a main combustion product of fossil fuels. Development of solid-state electrochemical devices for detecting CO2 is demonstrated based on various combination of solid electrolytes and auxiliary sensing materials. The object of this research is to develop various sensor performance for solid electrolyte gas sensor, and to test gas sensor performance manufactured. So we try to present a guidance for developing potential type gas sensor. We concentrated on development of manufacturing process and performance test.

  • PDF

기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구 (Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change)

  • 윤용한;권기욱
    • 한국환경과학회지
    • /
    • 제27권12호
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.

Mechanical behavior of HPFRCC using limestone calcined clay cement (LC3) and oxygen plasma treated PP fibers

  • Sajjad Mirzamohammadi;Masoud Soltani
    • Structural Engineering and Mechanics
    • /
    • 제89권4호
    • /
    • pp.349-362
    • /
    • 2024
  • High-performance fiber-reinforced cement composites (HPFRCC) are new materials created and used to repair, strengthen, and improve the performance of different structural parts. When exposed to tensile tension, these materials show acceptable strain-hardening. All of the countries of the globe currently seem to have a need for these building materials. This study aims to create a low-carbon HPFRCC (high ductility) that is made from materials that are readily available locally which has the right mechanical qualities, especially an increase in tensile strain capacity and environmental compatibility. In order to do this, the effects of fiber volume percent (0%, 0.5%, 1%, and 2%), and determining the appropriate level, filler type (limestone powder and silica sand), cement type (ordinary Portland cement, and limestone calcined clay cement or LC3), matrix hardness, and fiber type (ordinary and oxygen plasma treated polypropylene fiber) were explored. Fibers were subjected to oxygen plasma treatment at several powers and periods (50 W and 200 W, 30, 120, and 300 seconds). The influence of the above listed factors on the samples' three-point bending and direct tensile strength test results has been examined. The results showed that replacing ordinary Portland cement (OPC) with limestone calcined clay cement (LC3) in mixtures reduces the compressive strength, and increases the tensile strain capacity of the samples. Furthermore, using oxygen plasma treatment method (power 200 W and time 300 seconds) enhances the bonding of fibers with the matrix surface; thus, the tensile strain capacity of samples increased on average up to 70%.

도심재생하천 내 수리적 특성이 열환경 변화에 미치는 영향 평가: 청계천을 대상으로 (Impact Assessment on the Change of Thermal Environment, According to the Hydraulic Characteristic Urban Regeneration Stream: Cheonggyecheon Case Study)

  • 김정호;이주승;윤용한
    • 환경정책연구
    • /
    • 제14권2호
    • /
    • pp.3-25
    • /
    • 2015
  • 도심재생하천 내부의 수리적 특성이 열환경 변화에 미치는 영향을 알아보고자 하천의 물리적 구조와 수리적 특성, 기상요소, 온열환경을 분석하였다. 연구 대상지는 복원된 도시하천으로서 큰 의의를 가지는 청계천을 선정하였다. 유형은 물리적 구조별 녹피율의 차이에 따라 유형 I(0.0%)과 유형 II(20.2%)로 구분하였다. 여울이 끝나는 Ba지점에서 수온은 $0.2^{\circ}C$ 감소, 유속은 0.7~0.9m/s 증가, 용존산소량은 0.5~0.6mg/L 증가하였으며, 기온은 평균 $1.1{\sim}1.4^{\circ}C$ 감소, 상대습도는 평균 6.6~8.7% 증가, 풍속은 불규칙한 변화를 보였다. 습구흑구온도지수 분석결과, 유형에 따른 상류부의 하천 내부와 수면 외부의 값의 차이는 미비하였으나, 유형 I의 하류부에서 감소폭은 $0.3{\sim}0.6^{\circ}C$, 유형 II는 $0.8^{\circ}C$ 등이었다. 기온저감의 효과는 수직높이로 유형 I의 경우 120cm, 유형 II는 140cm까지 영향이 있었으며, 거리별 기온저감의 효과는 유형 I의 경우 여울이 끝나는 Ba지점 이후로 증가하였고, 유형 II의 경우 지속해서 감소하였다.

  • PDF