• Title/Summary/Keyword: granular discharge

Search Result 25, Processing Time 0.031 seconds

Control of Blue Phosphor Layer Cross-section and Its Improved Discharge Characteristics

  • Jeon, Byung-Soo;Choi, Seo-Young;Moon, Cheol-Hee;Heo, Eun-Gi;Lee, Kwang-Sik;Whang, Ki-Woong;Bae, Chul-Han
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.583-585
    • /
    • 2002
  • The effects of phosphor properties such as the granular sizes and shape on the crosssectional shape of phosphor layer and plasma discharge characteristics for improving the luminance and luminous efficiency in ac PDP have been investigated. As the granular size decreases, the thickness of vertical side of barrier rib in blue cell decreases, and wheras the thickness of bottom side increases due to increased dispersibility. In addition, the phosphor with round granular shape showing good dispersibility shows better voltage margin and higher luminous efficiency due to their improved discharge volume and packing density.

  • PDF

FLUID-GRANULE MIXED FLOIW DOWNSTREAM OF SCOUR HOLE AT OUTLET OF HYDRAULIC STRUCTURE

  • Kim, Jin-Hong;Shim, Myung-Pil;Kim, Kyung-Sub
    • Water Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.155-162
    • /
    • 2002
  • This study presents the theoretical approach for volume concentration, velocity profile, and granular discharge on the fluid-granule mixed flow downstream of the scour hole at the outlet of the hydraulic structure. Concept of dilatant model was applied for the stress-strain relationships of fluid-granule mixed flow since the flow downstream of the scour hole corresponds to debris flow, where momentum transfers through particle collisions. Mathematical formulations were derived using momentum equation and stress-strain relation of the fluid-granule mixture. Velocity profile under the assumption of uniform concentration over flowing layer showed the downward convex type. Deposition angle of downstream hump was found to be a function of an upstream slope angle, a dynamic friction angle and a volume concentration irrespective of flow itself, Granular discharge and the overflow depth were obtained with given values of inflow rates. Experimental results showed relatively good agreements with theoretical ones.

  • PDF

A study on Development of a Pneumatic Granular Applicator for Paddy Field (I) - Granular Discharge Rate, Diffuser and Optimal Application Conditions - (수도작용 송풍식 입제살포기 재발에 관한 연구 (I) - 입제 배출량, 분두 및 적정살포조건 -)

  • 정창주;정선옥;장영창;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • v.22 no.2
    • /
    • pp.127-136
    • /
    • 1997
  • This study was accomplished to develop a pneumatic granular applicator that can be attached to the conventional ride-on rice transplanter. Operating conditions of a metering device for the applicator were determined so as to obtain the required discharge rate of granules for field application. The shape and size of diffuser was selected for the applicator and the spacing between diffusers on a boom and the boom height were determined as an optimal application condition for uniform distribution. The diffuser spacing of 1m for the fertilizer and the diffuser spacing of 0.8m for the pesticide at the boom height over 0.8m were acceptable.

  • PDF

Temperature Characteristics of the Modified GAC by Microwave Irradiation and Benzene Adsorption (마이크로파 조사에 따른 개질화 활성탄의 온도특성 및 벤젠흡착)

  • Choi Sung-Woo;Kim Yoon-Kab
    • Journal of Environmental Science International
    • /
    • v.15 no.6
    • /
    • pp.579-586
    • /
    • 2006
  • The purposes of this paper were to monitor the temperature rising courses and spark discharge of the modified granular activated carbon (GAC) by microwave (MW) irradiation and to evaluate absorption of benzene. The GAC coated on $SiO_2$, boron, talc, ferrite was named as the modified GAC. Thermal and spark discharge measurement of virgin GAC and modifed GAC has been carried out using a MW device operating at 2450 MHz under various energy conditions. The results of this paper as follows. First, the modified GAC is more efficient than the virgin GAC in temperature control. Temperature gradient of the modified GAC is more lower than that of virgin GAC. The temperature gradient of GAC was observed in the following order : virgin GAC, Mn-Zn ferrite/GAC, Ni-Zn ferrite,/GAC, $SiO_2/GAC$, Boron/GAC, Talc/GAC. Second, the spark discharge of the modified GAC was diminished, compared with that of virgin GAC. Because of its excellent electrical insulating properties, the coating material prevents the spark discharge. Finally, the benzene adsorption capacity of the modified GAC decreased due to diminishing of adsorption site by the coating material. Considering the temperature gradient and spark discharge of GAC, the GAC coated $SiO_2$ would be appropriate absorbent under irradiation of MW.

Development of a Controller for Variable-rate Application of Granular Fertilizer (입제 비료의 변량 살포를 위한 제어기 개발)

  • Yu J.H.;Kim Y.J.;Ryu K.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.2 s.115
    • /
    • pp.108-114
    • /
    • 2006
  • This study was conducted to design and fabricate a controller for variable-rate application of granular fertilizer based on physical and chemical information, to analyze the performance of the controller and characteristics of a discharger. The result of the study are summarized as follows: 1. The charge ratios of discharger by accumulation heights of fertilizer in hopper were examined, and the variations in charge ratio were $72.58{\sim}93.33%$ and $63.14{\sim}94.42%$ for the fertilizers Super 21 and Sinsedae, respectively. The charge ratio also decreased as the rotational speed of discharger increased. 2. The coefficient of variation of discharge amount by rotational speed and discharge time of discharger were in the range of $2.94{\sim}11.23%$ and $2.82{\sim}10.80%$ for the fertilizer of Super 21 and Sinsedae. Except the rotational speed of 12 rpm, the coefficient of variation for discharge amount were relatively small with 4% more or less 3. In order to evaluate the rotational speed of discharger, the control signal in the range of $0{\sim}5V$ was subdivided into the 50 steps by 0.1V. The regression equation for the rotational speed of discharger was Y=55.984X-79.174(X: input voltage, V, Y: discharger speed, RPM) and the $R^2$ was 0.99. 4. In order to evaluate the performance of the controller for variable-rate application of granular fertilizer, settling time to unit step input was examined. The settling time varied from 0.8sec to 1.4 sec.

A Study on the Characteristics of Activated Carbons Supported Metal by Microwave Irradiation (마이크로파 조사에 따른 금속이 담지 된 활성탄의 특성 연구)

  • Kim, Sung-Wook;Kim, Jung-Bae;Choi, Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.18 no.5
    • /
    • pp.501-508
    • /
    • 2009
  • In this study, the characteristics of granular activated carbon (GAC) supported metal was investigated in an area influenced by flame discharge and temperature variation during irradiating microwave. The modified GAC was formulated by impregnating metal hydroxides of nickel (Ni/GAC), barium (Ba/GAC), copper (Cu/GAC), zinc (Zn/GAC), cobalt (Co/GAC) and lanthanum (La/GAC). Ba/GAC was selected as it showed lack of spark discharge and temperature increasing aspects. Comparison of adsorption and desorption amount of GAC and Ba/GAC showed that adsorption and desorption rate of the GAC were higher than those of Ba/GAC. The results show that the presence of barium can decrease adsorption/desorption rate because of plugging pore of GAC. Toluene regeneration rate of Ba/GAC was better than that of GAC due to barium loading. Finally, GAC with barium can be controled a rapid increasing temperature and spark discharge, increased the regeneration rate of toluene during desorption by irradiating microwave.

Experiments on granular flow in a hexagonal silo: a design that minimizes dynamic stresses

  • Hernandez-Cordero, Juan;Zenit, R.;Geffroy, E.;Mena, B.;Huilgol, R.R.
    • Korea-Australia Rheology Journal
    • /
    • v.12 no.1
    • /
    • pp.55-67
    • /
    • 2000
  • In this paper, an experimental study of the rheological behavior of granular flow in a new type of storage silo is presented. The main characteristic of the new design is a hexagonal shape chosen with the objective of minimizing the stresses applied to the stored grains, and to reduce grain damage during the filling and emptying processes. Measurements of stress distribution and flow patterns are shown for a variety of granular materials. Because of the design of the silo, the granular material adopts its natural rest angle at all times eliminating collisional stresses and impacts between grains. A homogeneous, low friction flow is naturally achieved which provides a controlled stress distribution throughout the silo during filling and emptying. Secondary dynamic stresses, which are responsible for wall failure in conventional silos of the vertical type, are completely eliminated. A comparison between the two geometries is presented with data obtained for these silos and a number of granular materials. The discharge pattern inhibits powder formation in the silo and the filling system virtually eliminates unwanted material packing. Finally, notwithstanding the rheological advantages of this new design, the hexagonal cells that constitute the silo have many other advantages, such as the possible use of solar energy to control the humidity inside them. The cell type design allows for versatile storage capabilities and the elevation above the ground provides unlimited transportation facilities during emptying.

  • PDF

Case Studies on Shock Vibration at Coal Silo Structure of Power Plants (화력발전소 Coal Silo 구조물의 충격성 진동에 대한 사례 연구)

  • Im, Jung-Bin;Lee, Hong-Ki;Son, Sung-Wan;Park, Sang-Gon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.103-106
    • /
    • 2005
  • This paper reviews the dynamic load phenomenon referred to as 'silo quaking', caused shock vibration and loud noise, during gravity discharge in coal silos. Quaking in tall silo is examined using experimental data obtained from a Coal Power Plant and several experimental and numerical investigations available in the published literature. In the experiment, the acceleration was measured at various height on the silo column and floor and by doing so, not only could the variation of the amplitude of the quaking be observed, but also the propagation of waves could clearly be seen. Through an overview of recent research on this subject, it is shown that the current silo quaking is produced by slip-stick friction between the internal wall of silo and the granular material, i.e. coal.

  • PDF

Water Droplet Ejection Characteristics of a Wet Porous Point-Plate Airgap (다공성 수침-평판전극간의 수적 방출 특성)

  • Jung, Jae-Seung;Lee, Woo-Seok;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2005-2010
    • /
    • 2009
  • Water droplet ejection characteristics of a point-to-plate airgap, with a wet porous point as a corona electrode, has been investigated. And the water droplet traces, charge, mass and number were measured experimentally. More particles are observed with wet porous point than metal point because the corona-discharging wet porous point can eject a number of water droplets. The water droplets ejected from the positive-corona-discharging wet porous point showed very fine traces as compared with those from the negative-corona-discharging wet porous point. Moreover, the water droplets ejected from the AC-corona-discharging wet porous point showed granular-like larger traces. It was shown that the weak corona discharge can eject smaller water droplets with larger ratio of mass-to-charge than the intense corona discharge.