• 제목/요약/키워드: gold film

검색결과 277건 처리시간 0.034초

영화에 나타난 그리스 신화의 신들의 의상 연구 (Study on Costumes of Greek Mythology Gods in Films)

  • 류수현
    • 복식
    • /
    • 제63권6호
    • /
    • pp.69-83
    • /
    • 2013
  • This research is to analyze costumes of Greek Mythology Gods in films using Morris' semiotics. In film "Clash of The Titans", Zeus' costume of shining gold armored body suit and long manteaux expressed the limitless sublime. The definite form contouring body shape of his costume also demonstrated classical beauty. Hades' costume of dark colored armor, long manteaux, and transformation via smoke also described the limitless sublime. The unbalanced and irregular shaped armor showed ugliness. In "Percy Jackson & The Olympians: The Lightening Thief", the armor and long manteaux of Zeus showed the limitless sublime. The beauty of his body and his sophisticated business wear indicated classical beauty. These features were also present in Poseidon's costume as well. The limitless sublime and ugliness are implied in Hades' look by portraying him as having a monster body with horns and wings, and his costume of punk look. In "Immortals", gods of Olympus wore clothing that was reminiscent of Egyptian times, which represented a time of strong royal authority, in order to expose the limitless sublime. Classical beauty was shown in the beauty of their body. Titans' costumes and look of non-human being were composed of black and red to present ugliness. The inherent meanings of Gods' costumes are death of god, patriarchy, and the good triumphing over the evil. The Greek gods are not held in the same reverence in the contemporary society. However mythology inspires lots of visual creations. The results help to accumulate a creative design database for fashion.

메모리소자 응용을 위한 초박막의 제작 및 특성 평가 (Evaluation of the fabrications and properties of ultra-thin film for memory device application)

  • 정상현;최행철;김재현;박상진;김광호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.169-170
    • /
    • 2006
  • In this study, ultra thin films of ferroelectric vinylidene fluoride-trifluoroethylene (VF2-TrFE) copolymer were fabricated on degenerated Si (n+, $0.002\;{\Omega}{\cdot}cm$) using by spin coating method. A 1~5 wt% diluted solution of purified vinylidene fluoride-trifluoroethylene (VF2:TrFE=70:30) in a dimethylformamide (DMF) solvent were prepared and deposited on silicon wafers at a spin rate of 2000~5000rpm for 30 seconds. After annealing in a vacuum ambient at $200^{\circ}C$ for 60 min, upper gold electrodes were deposited by vacuum evaporation for electrical measurement. X-ray diffraction results showed that the VF2-TrFE films on Si substrates had $\beta$-phase of copolymer structures. The capacitance on $n^+$-Si(100) wafer showed hysteresis behavior like a butterfly shape and this result indicates clearly that the dielectric films have ferroelectric properties. The typical measured remnant polarization (2Pr) and coercive filed (EC) values measured using a computer controlled a RT-66A standardized ferroelectric test system (Radiant Technologies) were about $0.54\;C/cm^2$ and 172 kV/cm, respectively, in an applied electric field of ${\pm}0.75\;MV/cm$.

  • PDF

Electrochemistry and Electrokinetics of Prussian Blue Modified Electrodes Obtained Using Fe(III) Complex

  • 문성배;문정대
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권9호
    • /
    • pp.819-823
    • /
    • 1995
  • Thin films of two kinds of Prussian Blue (PB)-modified, using iron(Ⅲ) complex instead of conventional FeCl3, were prepared on a gold substrate and these films were able to be electrochemically reduced in potassium nitrate solution. In case of PB-modified films prepared from Fe(Ⅲ)-ethylenediamine-N,N'-diacetic acid (FeEN3+)/K3Fe(CN)6 solution, the mid-peak potential was 0.156 V in 0.1 M KNO3 and it was found that potassium ion migrates into or out of the film during the electrolysis. These films were shown to be electrochromic. These films exhibited smaller peak separation than those formed from Fe(Ⅲ)-tartaric acid (FeTA3+)/K3Fe(CN)6 system. The diffusion coefficient of Fe(CN)63-/4- redox couple, evaluated using the fabricated Au rotating disc electrode(rde) previously reported, was in good agreement with the existing data. Two experimental procedures, including the voltammetry at relatively low scan rates and the rde study, have been used in order to characterize the electrode kinetics. The electrode kinetics of some redox couples (FeEN2+-FeEN3+ and FeTA2+-FeTA3+) on both PB-modified thin films and bare Au electrode were studied using a Au rde. In all cases the rate constants of electron transfer obtained with the PB-modified film electrodes were only slightly less than those obtained for the same reaction on bare Au disc electrodes. The conductivities, as determined from the slopes of the i-V curves for a ca. 1 mm sample for dried PB-modified potassium-rich and deficient bulk samples pressed between graphite electrodes, were 6.21 × 10-7 and 2.03 × 10-7(Ω·cm)-1, respectively.

분로저항을 가진 저항형 초전도 한류기의 전기적 특성 (Electrical properties of a resistive SFCL with shunt resistor)

  • 최효상;현옥배;김혜림;황시돌;김상준
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.343-347
    • /
    • 1999
  • YBCO film을 이용한 meander 형태의 저항형 한류기에서 고장이 발생하였을 때 초기의 과도상태에서 볼수 있는 첨두전류를 억제하기 위하여 shunt 저항을 병렬로 취부한 경우의 전기적특성을 살펴보았다. 인가전압을 16.5 V$_{peak}$로 가하고 R$_0$는 1 ${\omega}$,R$_L$을 7.7 ${\omega}$으로 하고 shunt 저항을 5 ${\omega}$으로 하였을 때 약 12.2 A$_{peak}$의 전류값에서 최초quench가 발생하였으며 초전도 한류소자에 quench 발생으로 인한 저항이 발생함과 동시에 I$_1$으로 흐르던 사고전류의 일부가 shunt 저항이있는 I$_2$으로 서서히 분로하여 첨두전류가 거의 발생하지 않았다. 이때 초전도 한류기를 적용하지 않은 경우 최대 사고전류는 약 16.5 A$_{peak}$이었으며 초전도 한류기를 적용한 경우는 최대 한류전류값이 9 A$_{peak}$에서 4주기후에는 5.8 A$_{peak}$이었다. 인가전압 V$_0$=113 V$_{peak}$이고 표준저항 R$_0$는 1${\omega}$, 그리고 R$_L$을 7.7 ${\omega}$으로 하고 shunt 저항을 5 ${\omega}$으로 하였을 때 사고각 0 $^{\circ}$에서 사고전류값이 최고 23.0 A$_{peak}$까지 상승하고 이후 일정한 값을 유지하였다. 일반적으로 사고발생 직후에는 전류변화율에 의하여 전류값의 급격한 상승을 보이지만 shunt 저항이 전류분류의 역할을 수행하여 첨두전류는 거의 발생하지 않았다. 또한 상온의 gold층의 저항을 감안했을 때 사고발생후 약 36msec 후에 상온에 도달하였으며 shunt 저항이 없는 경우의 11 msec에 비하여 약 3배이상 길어졌다. 사고각 45 $^{\circ}$와 90 $^{\circ}$인 경우는 반복실험에 의한 시편의 특성저하(degradation)에 의하여 정상상태에서 초전도체에 흐르는 전류가 약간 발생하였다. 계통의 신뢰성이 중요한 요소로 작용하는 실제운전에서는 시편의 특성저하에 의한 quench전류의 감소를 감안하여 적절한 운전조건을 도출하여야 한다. 이상에서 앞으로는 장기간의 실제운전 조건을 고려하여 시편의 특성저하(degradation)와 가혹조건에 대한 전기적 특성에 대한 연구를 병행하고자 한다.

  • PDF

Development of Surface Plasmon Resonance Immunosensor through Metal Ion Affinity and Mixed Self-Assembled Monolayer

  • Lee, Si-Ra;Sim, Sang-Jun;Park, Chul-Hwan;Gu, Man-Bock;Hwang, Un-Yeon;Yi, Jong-Heop;Oh, Byung-Keun;Lee, Jin-Won
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권10호
    • /
    • pp.1695-1700
    • /
    • 2008
  • An immunosensor based on surface plasmon resonance (SPR) with enhanced performance was developed through a mixed self-assembled monolayer. A mixture of 16-mercaptohexadecanic acid (16-MHA) and 1-undecanethiol with various molar ratios was self-assembled on gold (Au) surface and the carboxylic acid groups of 16-MHA were then coordinated to Zn ions by exposing the substrate to an ethanolic solution of $Zn(NO_3)_2\cdot 6H_2O$. The antibody was immobilized on the SPR surface by exposing the functionalized substrate to the desired solution of antibody in phosphate-buffered saline (PBS) molecules. The film formation in series was confirmed by SPR and atomic force microscopy (AFM). The functionalized surface was applied to develop an SPR immunosensor for detecting human serum albumin (HSA) and the estimated detection limit (DL) was 4.27 nM. The limit value concentration can be well measured between ill and healthy conditions.

Glucose Oxidation on Gold-modified Copper Electrode

  • Lim, Ji-Eun;Ahn, Sang Hyun;Pyo, Sung Gyu;Son, Hyungbin;Jang, Jong Hyun;Kim, Soo-Kil
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2685-2690
    • /
    • 2013
  • The activities of Au-modified Cu electrodes toward glucose oxidation are evaluated according to their fabrication conditions and physico-chemical properties. The Au-modified Cu electrodes are fabricated by the galvanic displacement of Au on a Cu substrate and the characteristics of the Au particles are controlled by adjusting the displacement time. From the glucose oxidation tests, it is found that the Au modified Cu has superior activity to the pure Au or Cu film, which is evidenced by the negative shift in the oxidation potential and enhanced current density during the electrochemical oxidation. Though the activity of the Au nanoparticles is a contributing factor, the enhanced activity of the Au-modified Cu electrode is due to the increased oxidation number of Cu through the electron transfer from Cu to more electronegative Au. The depletion of electron in Cu facilitates the oxidation of glucose. The stability of the Au-modified Cu electrode was also studied by chronoamperometry.

반응성이 있는 메타크릴레이트 공중합체를 이용한 정전용량형 습도센서 (Capacitive Humidity Sensor Using Reactive Methacrylate Copolymers)

  • 공명선;이임렬
    • 마이크로전자및패키징학회지
    • /
    • 제10권4호
    • /
    • pp.21-27
    • /
    • 2003
  • 정전 용량형 고분자막 감습재료로 사용하기 위하여 서로 반응성이 있는 공중합체들 methyl methacrylate (MMA), ethyl methacrylate (EMA), acrylic acid (MA) 와 hydroxyethyl methacrylate (HEMA)의 공중합체들을 합성하였다. 정전 용량형 습도센서는 가교화된 폴리메타크릴레이트 공중합체 막의 양면에 금 전극을 형성시켜 제조하였다. 공중합체에서의 HEMA양이 증가할수록 상대습도에 따른 정전 용량은 증가하였다. MMA/MA/HEMA=40/10/10의 경우, 상대습도가 30%RH, 60%RH 및 90%RH에서의 정전 용량은 각 102, 134와 165 pF이었다. 또한 히스테리시스, 온도 사이클 그리고 장기안정성 결과를 측정하여 정전용량형 습도센서로서의 특성을 평가하였다.

  • PDF

비정질 셀레늄의 박막 제조공정에 따른 미세구조와 IV특성 (The X-ray Detection and morphology Characteristics on Evaporation Temperature of amorphous Selenium based digital X-ray detector)

  • 공현기;차병열;이규홍;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.51-54
    • /
    • 2002
  • Recently, due to its better photosensitivity in X-ray, the amorphous selenium based photoreceptor is used on digital direct method conversion material. Compared to other photoconductive material, amorphous selenium has good X-ray response characteristic and low leakage current. It has many parameters of detecting X-ray response on selenium. Among of them, it is well known that manufacture of a-Se is the most basic element. In this paper, we fabricated two types of amorphous selenium sample which had time variable. The one was fabricated continuous deposition sample and the other was step by step sample. Thickness of sample was $300{\mu}m$ and top electrode was evaporated gold. We investigated the leakage current and photo current of them and analysed their electrical characteristics. For analyzing morphology of samples, SEM and surface was pictured. We found that step by step deposition method could be applied for novel fabricating amorphous selenium film.

  • PDF

Non-invasive Transcutaneous pCO2 Gas Monitoring System for Arterial Blood Gas Analysis

  • Bang, Hyang-Yi;Kang, Byoung-Ho;Eum, Nyeon-Sik;Kang, Shin-Won
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.311-316
    • /
    • 2011
  • Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide($pCO_2$) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 ${\mu}m$ in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis($TcpCO_2$) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.

Color Tunable Nanostructures by Polarization Control for Display Applications

  • Cho, Eun-Byurl;Ko, Yeong-Il;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.567-567
    • /
    • 2013
  • Surface plasmon resonance is the enhancement of electromagnetic wave caused by oscillation on the metal and dielectric interfaces. Surface plasmons with nanohole arrays provides an enhancedresonance for the specific wavelengths of interests. Asymmetric array of nanoscale structures can enable orientation dependent shift of resonance wavelengths when combined with the control of polarization for incident visible light, thus providing color tunability. Appropriate lattice constants along the direction of polarization in rectangular nanohole arrays can determine the resonance condition generating red (R), green (G), and blue (B) colors and potentially be applied to display applications. In ourprevious report, we have optimized the ion beam nanomachining conditions to fabricate the nanostructures on the metal film. We apply the fabrication conditions to make nanoscale hole arrays using 100 nm thick gold layer on the glass substrate with the optimal design of periodicities along x, y, and diagonal directions of a=440 nm, b=520 nm, c=682 nm, and the hole diameter of d=200 nm. Using the reflective light in dark field mode of optical microscope, we can observe different colors. When the polarizer is paralleled along a, b, or c direction, the represented color is changed to R, G, and B, respectively. We further map the color using i1 to correlate the conditions of the nanohole arrays with their characteristic color.

  • PDF