• 제목/요약/키워드: gold crown

Search Result 137, Processing Time 0.023 seconds

Roentgenologic Studies on the Periodontal Ligaments and Alveolar Bone Changes in Various Prosthesis (보철물(補綴物) 장착시(裝着時) 치근막(齒根膜)과 치조골(齒槽骨)의 변화(變化)에 관(關)한 X선학적(線學的) 연구(硏究))

  • Lee, Jae-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.17-22
    • /
    • 1969
  • Intra-oral films of 155 patients were taken on the areas of Gold Crown-Bridges, S. P. Bridges and Partial Dentures. And the author observed periodontal ligaments widening rates, the presence of periapical lesions and the alveolar bone patterns on the Partial Denture Saddle portions. The results were as follows : 1. Periodontal ligaments a) Periodontal ligaments widening rate increased obviously with the duration of wearing those prosthetic appliances. b) Periodontal ligaments widening rate was the highest in partial denture wearing patients, and then that of S. P. Crown Bridge patients, Gold Crown Bridge wearing females, Gold Crown Bridge males were the sequences. 2. Periapical lesions a) Periapical lesions increased with the wearing duration of those prosthetic appliances. But they did not increase in proportion to the duration. Periapical lesions were about the same in the teeth with those appliances showing relatively higher rate in Partial Denture abutment teeth and the lowest in Gold-Bridge abutment teeth. 3. Alveolar bone of Partial Denture saddle portion One third of all(32%) were normal with their smooth and compact bone pattern so that they were considered to perform normal function.

  • PDF

Causes of failed implant attachments and application of double crown implant overdenture in one patient (한 환자에서 실패한 임플란트 부착장치들의 원인과 이중관 임플란트 피개 의치의 적용)

  • Kwon, Jae-Uk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.368-374
    • /
    • 2018
  • In this case, the patient was restored with gold Hader bar mandibular implant overdenture using two implants about 10 years ago, and the retentive force was lost due to severe wear of the bar due to 3.5 years use. The overdenture was repaired using a Locator attachment, but the male part was completely worn after 6.5 years use. Finally, we used a hybrid telescopic double crown with a friction pin to fabricate a new implant overdenture, which was observed for 2 years and showed excellent prognosis. So, we describe the cause of failure of each attachment (Gold Hader bar, Locator) in two implant overdentures and report on the advantages and disadvantages of double crown implant overdenture and the conditions for success.

Changes in the Standardized Uptake Value According to the Type of Metal of Dental Prosthesis in PET-CT Fusion Image (PET-CT 융합 영상에서 치과보철물의 금속 종류에 따른 표준섭취계수 값의 변화)

  • Han, Sang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.117-122
    • /
    • 2018
  • In this study, HU(hounsfield unit) value of CT generated by dental prosthesis was measured according to the type of metal when PET-CT was performed, and the degree of distortion and standard deviation of SUV(standard uptake value) and to propose a method to reduce errors in image reading. PET-CT was performed using actual teeth, metal crown, gold crown, titanium, and zirconia dental prosthesis. Compared with general teeth, the SUV value increased with increasing HU value. The SUV value of metal crown, titanium, and zirconia was increased by 37% and the gold crown increased by 45.4%. In addition, image distortions were small in general teeth, metal crown, titanium, and zirconia, but hard curing of the gold crown occurred and image distortion occurred. Therefore, since the metal type of the dental prosthesis affects the SUV value, the NAC(non attenuation correction) PET image of the dental prosthesis can be helpful in the diagnosis of the patient using the gold material.

A Study on All Ceramic Crown Manufactured Using Gold Plating Upon Refractory Cast Die (매몰재 Die 위에 금도금을 이용한 전부 도재관 제작에 관한 연구)

  • Shin, Moo-Hak;Kim, Yeoun-Soo;Chung, Hee-Sun
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.49-55
    • /
    • 2000
  • In manufacturing the all-ceramic crown whick look close to natural teeth, the effectiveness of the improved technique is expectected the technique of the heat treatment of gold plating coating die was experimented of a refractory cast model. The following results were obtainde 1. An advantage of build up on east die with out manufacturing veneer, crown, core, or masking(reduction of technical process, and retrenchment of time and money) 2. Esthetically more close to natural teeth than other technique 3. Easy to remove a refractors cast die 4. In manufacturing ceramo-metal crown the enomous effectiveness was obtainde on applying in the areas of cervical margin, the metal surface, and in the treatment of pinhole.

  • PDF

Comparison of retention forces with various fabrication methods and materials in double crowns

  • Guven, Melahat Celik;Tuna, Meral;Bozdag, Ergun;Ozturk, Gizem Nur;Bayraktar, Gulsen
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.308-314
    • /
    • 2017
  • PURPOSE. The purpose of this study was to analyze the retention force changes and wear behaviours of double-crown systems over long-term use. MATERIALS AND METHODS. Ten groups, each consisting of six samples, were evaluated. Specifically, casting gold alloy primary crown - casting gold alloy secondary crown (AA), laser sintering primary crown - laser sintering secondary crown (LL), casting Cr alloy primary crown - casting Cr alloy secondary crown, (CC) zirconia primary crown - electroformed secondary crown (ZA), and CAD/CAM titanium alloy primary crown - CAD/CAM titanium alloy secondary crown (TT) groups were evaluated at cone angles of $4^{\circ}$ and $6^{\circ}$. The samples were subjected to 5,000 insertion-separation cycles in artificial saliva, and the retention forces were measured every 500 cycles. The wear levels were analyzed via SEM at the beginning and end of the 5,000 cycles. RESULTS. In all samples, the retention forces increased when the conus angle decreased. The highest initial and final retention force values were found in the $LL-4^{\circ}$ group (32.89 N-32.65 N), and the lowest retention force values were found in the $ZA6^{\circ}$ group (5.41 N-6.27 N). The ZA groups' samples showed the least change in the retention force, and no wear was observed. In the other groups, wear was observed mostly in the primary crowns. CONCLUSION. More predictable, clinically relevant, and less excursive retention forces can be observed in the ZA groups. The retention force values of the LL groups were statically similar to those of the other groups, except the ZA groups.

A study on the Scythian Bracelets

  • Kim, Moon-Ja
    • Journal of Fashion Business
    • /
    • v.8 no.3
    • /
    • pp.1-9
    • /
    • 2004
  • Scythians kept herds of horses, cattle, and sheep, lived in tent-covered wagons, and fought with bows and arrows on horseback. They developed a rich culture characterized by opulent tombs, fine metalwork, and a brilliant art style. The excavations of royal burials have provided the most complete record of the jewelry of the Scythians. Typical art objects were in the form of stags or other animals, hammered or stamped out of gold and often inlaid with colored stones or glass. The Bracelet consisted of two of distinct technique : One made from heavy forged gold bars, terminated with more delicate spiraled finals. Another technique used beaten gold foil, perhaps as thick as a piece of paper with fabulous designs repousse and chased (impressed in relief into the gold with small hammers and chisels) into the metal. They also used stones and clay dies to form gold foil into people repeated also motifs for use in torques and belts. The Scythian Bracelet were divided into 4 styles according to the shape, Bracelets with ends shaped like beasts style, Spiral style, Layers style, Crown with openwork style. Scythian Bracelet in the Black Sea region had completely degenerated, stifled by motifs and shapes of Greek origin, retaining its representational realism and its full emotional vitality.

MECHANICAL PROPERTIES OF QUARTZ FIBER POST (Quartz fiber post의 물리적 특성에 관한 연구)

  • Lee Young-Soo;Kang Ik-Je
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.68-78
    • /
    • 2002
  • The post core system has been used for reconstructon of severely damaged crown by caries or trauma. But problems such as crown exfoliation, post core fracture and root fracture have been reported. Ideal mechanical properies of the post require high fracture strength, high elastic limit and high resistance against fatigue and corrosion Modulus of elasticity of the post should be similar with that of dentine. Low hardness is also required for the convenience of post removal in failure. Furthermore, the post itself must be translucent for the esthetical purpose. Several types of the post have been developed to satisfy the criteria above mentioned. The purpose of this study was to find out the mechanical properties of quartz fiber post by comparing with those of gold post and zirconia post. The results of this study were as follows : 1. Maximal fracture strength and stiffness of quartz fiber post were similar with those of gold post and zirconia post. 2. Young's modulus and hardness of quartz fiber post were lower than those of gold post and zirconia post. Mechanical property of quartz fiber post against post fracture was similar with that of gold post and zirconia post. Mechanical property of quartz fiber post against root fracture was higher than that of gold post and zirconia post. Quartz fiber post could be removed easily due to low hardness.

THE STRESS ANALYSIS OF SUPPORTING TISSUE AND IMPLANT ACCORDING TO CROWN RESTORATIVE MATERIALS AND TYPE OF IMPLANT (수복재료와 임플랜트 종류에 따른 임플랜트 및 지지조직의 응력분포)

  • Choi Chang-Hwan;Oh Jong-Suk;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.53-67
    • /
    • 2002
  • This study was aimed to analyze the stress distribution of implant and supporting tissue in single tooth implant restoration using Branemark $system^{(R)}$(Nobel Biocare, Gothenberg, Sweden) and Bicon system(Bicon Dental Implants, Boston, MA). Two dimensional finite element analysis model was made at mandibular first premolar area As a crown materials porcelain, ceromer, ADA type III gold alloy were used. Tests have been performed at 25Kgf vertical load on central fossa of crown portion and at 10Kgf load with $45^{\circ}$ lateral direction on cusp inclination. The displacement and stresses of implant and supporting structures were analyzed to investigate the influence of the crown material and the type of implant systems by finite element analysis. The results were obtained as follows : 1. The type of crown material influenced the stress distribution of superstructure, but did not influence that of the supporting alveolar bone. 2. The stress distribution of ceromer and type III gold alloy and porcelain is similar. 3. Stress under lateral load was about twice higher than that of vertical load in all occlusal restorative materials. 4. In Bicon system, stress concentration is similar in supporting bone area but CerOne system generated about 1.5times eater stress more in superstructure material. 5. In Branemark models, if severe occlusal overload is loaded in superstvucture. gold screw or abutment will be fractured or loosened to buffer the occlusal overload but in Bicon models such buffering effect is not expected, so in Bicon model, load can be concentrated in alveolar bone area.

CONSERVATION TREATMENT OF GOLD CROWN EXCAVATED FROM IMDANG-DONG TOMB (임당동 고분출토 금동관의 보존처리)

  • Lee, Oh-Hee
    • 보존과학연구
    • /
    • s.7
    • /
    • pp.48-55
    • /
    • 1986
  • The gold crown unearthed from the ancient tombs at Imdang-dong, Kyongsan-gun, Kyongsangbuk-do was in a state of severe corrosion that its original pattern couldn't be identified. Therefore, for the conservation of the relics, the following methods are employed :1. With 10% formic acid are used for the elimination of the bronze-rust and then plated them with gold.2. As a rust-proof treatment, 1% Benzotriazole is used for stem corrosion as well3. For protection and reinforcement of the surface of the relics, 30% incralac agentsare used.4. Pieces of fragments are bonded together by cyanoacrylate and on the backside are coated partially with Araldite for the reinforcement of the glass-wool.5. Silica-gels are kept into the acryl box for perfect maintenance.

  • PDF