• Title/Summary/Keyword: geothermal application

Search Result 107, Processing Time 0.029 seconds

Fuzzy Control Application Strategy for Energy Saving in HVAC System (공조시스템의 에너지절약을 위한 Fuzzy제어 적용방안 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.2
    • /
    • pp.31-37
    • /
    • 2007
  • The fuzzy control algorithm for HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with fuzzy control are supply air temperature, chilled water temperature and condenser temperature. This study has been done by using TRNSYS program in order to analyze the HVAC system response. As a result, the fuzzy control algorithm with PID algorithm shows good energy performance in comparison with conventional one.

  • PDF

A Continuous Sequential Decision Process Model for R&D Economic Feasibility Assessment of the GDHS in Chejoo Island and Its Application (제주도 GDHS의 R&D투자 타당성 분석을 위한 연속적 SDP모형의 개발 및 응용사례연구)

  • Yang, Moon-Hee;Chang, Kyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.24 no.1
    • /
    • pp.115-126
    • /
    • 1998
  • A GDHS(Geothermal District Heating System) is a heating system supplying a group of districts with heat extracted from geothermal sources. Due to various advantages of GDHS including the saving of fuel consumption as well as the reduction of air pollution, a world-wide trend is to replace central/individual heating systems with GDH systems. The basic point of this paper is that a crash program mentality leads to inappropriate decisions about policy issues in large-scale research and development like the development of GDHS, R&D funding should be viewed as a sequential decision, not a once-and-for-all choice. Hence we develop on economic feasibility assessment model based on a continuous sequential decision process for the Chejoo Island GDHS Project by modifying Roberts's model.

  • PDF

Monitoring and Control of Geothermal Apparatus Using Mobile Devices (모바일 PDA를 이용한 지열냉난방의 감시 및 제어)

  • Ji, Yang-Hwan;Jo, Yong-Byum;Choi, Seung-Dal;Nam, Boo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.331-333
    • /
    • 2005
  • In this paper, we implemented the monitoring and control of geothermal heating and cooling system using mobile devices. The main idea of this system is to provide the convenience if the system can be controled in remote place with monitoring using the mobile devices like PDA. Basically, the system consists of the Server-Client structure divided into two parts, one is PDA and PC, the other is PC and PLC(Programmable Logic Controller). The PDA, which is equipped with Windows CE as as, monitors the status of the devices (motors and sensors, etc) attached to PLC and controls them. This does the system to be controled by the commands, which we assume to control, with wireless transmission between PC and PLC. The PDA parts are responsible for monitoring and control the devices connected to the PLC, and the PC part which equipped with the application is to provide the relation between PDA and PLC. The Ladder Program is used to control the sequences of the PLC..

  • PDF

Demand Control Application Strategies for Saving Electric Power Price of Central Cooling System (중앙 냉방시스템의 전력량 요금절감을 위한 디맨드제어 적용방안 연구)

  • Hwang, Jin-Won;Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • In this study, computer simulation for demand control strategies to save the electric energy and power price in the building central cooling system is done. The demand control and outdoor reset control algorithms are applied by consideration the electric energy and power price according to the energy consumption characteristics. The suggested control methods show better responses in the power price and energy consumption in comparison with the conventional one.

The Performance Analysis for Low-Depth Unit-type Ground Heat Exchanger According to Grouting Materials (저심도 지중열교환기 개발을 위한 그라우트 재료에 따른 채열성능 검토 연구)

  • Oh, Jin-Hwan;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.2
    • /
    • pp.7-11
    • /
    • 2015
  • Recently, as the demand for sustainable energy sources is increasing, ground-source heat pump (GSHP) systems are receiving growing attention. However, the initial cost of GSHP system is higher than it of the conventional systems, especially, in small-size buildings. Therefore, for the application to the small-size building, it is necessary to develop small-size ground heat exchanger with small-size buildings. In this study, analysis of unit-type heat exchanger due to grouting materials. As a result, 1492.14 W of heat exchange rate was acquired in the condition of cement-silica sand-graphite materials.

The Field Test of bankfiltration(including alluvial and riverbed deposits) Source Heat Pump Cooling & Heating System (강변여과수(충적층 및 하상)를 이용한 열펌프 냉난방시스템의 실증연구)

  • Hwang, Ki-Sup;Jung, Woo-Sung;Ahn, Young-Sub
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1186-1190
    • /
    • 2006
  • Rising in important of alternative energy due to the recenfly high oil price and environment problem. Application of alternative energy has become higher than before. In this study, facility test of Geothermal energy to bankfiltration was examined appliying changwon pumping well. Initial installation cost was efficiently saved by connecting a heat pump system to pumping well in changwon bankfiltration site. A falling-off in efficiency of heat pump was free due to the bankfiltration that is rare for the temperature fluctuation. Therefore, Heat soure as bankfiltration system solve the existing facilities problems of geothermal heat pump system.

  • PDF

A Experimental Study on the Application of GRNN for On-Off Control in Floor Radiant Heating System (바닥복사 난방시스템의 개폐식 제어에 대한 GRNN 적용에 관한 실험적 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.16-23
    • /
    • 2020
  • In this study, the control characteristics and effects of control methods on heating performance and energy consumption for the hot water floor radiant heating control system of a residential apartment were research by experiment. As a control method, On-Off control and outdoor reset control methods with GRNN(General Regression Neural Network) and without GRNN are considered. Also, the control performances with regard to improvement of indoor thermal environment and reduction of energy consumption are compared, respectively. Experiment results show that the performance of the control method with GRNN is better than that of conventional on-off control method without GRNN in the responses of room set temperature and energy saving.

Numerical Study on Indoor Air Quality Based on Age of Air for the Underfloor Air Distribution System (수치해석을 이용한 바닥공조 시스템의 공기환경 평가)

  • Pang, Seung-Ki;Ahn, Hye-Rin;Lee, Won-Keun;Moon, Ki-Sun;Kim, Jongryul;Lee, Kwang-ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.40-46
    • /
    • 2016
  • In order to improve air quality of indoor environment, studies of the underfloor air distribution (UFAD) system for application in buildings are actively in progress based on temperature and air flow distribution. However, although the age of air is the major evaluation parameter, there has been very little study on this parameter for the UFAD system. In this study, we investigated the age of air to reach the air diffuser, which is installed at the bottom of the interior by the UFAD system. Computational fluid dynamics simulations showed no regular pattern to the maximum value of the age of air in accordance with air flow rate and the velocity at air diffuser. These factors can be deduced from air movement by considering that air emitted from air conditioners was rotated according to the bottom shape of the floor, and then, the age of air in the rotation center was increased. The average age of air of internal interior was reduced considerably as the flow velocity at the underfloor air diffuser was increased from 0.5 m/s to 1.0 m/s However, the age of air was not substantially affected with change in the air volume. Moreover, when the flow velocity at the underfloor air diffuser was higher than 1.0 m/s, the age of air showed no significant difference with change in air volume or height of measurement. These results imply that indoor air quality is more substantially influenced by flow velocity than air volume, and the appropriate flow velocity is 1 m/s or more.

Impact of Design Parameters on Length and Application Effect of Surface Water Heat Exchanger(SWHE) (지표수 열교환기의 용량과 적용 효과에 대한 설계 인자의 영향)

  • Sohn, Byonghu;Min, Kyong-Chon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Commercial buildings are generally cooling-dominated and therefore reject more heat to a vertical ground heat exchanger(GHE) than they extract over the annual cycle. Shallow ponds can provide a cost-effective means to balance the thermal loads to the ground and to reduce the length of GHE. The objective of this work has been to develop a design tool for surface water heat exchanger(SWHE) submerged in shallow pond. This paper presents the analysis results of the impact of design parameters on the length of SWHE and its application effect on geothermal heat pump(GHP) system using vertical GHE. In order to analysis, We applied ${\epsilon}-NTU$ method on designing the length of SWHE. Analysis results show that the required pipe length of SWHE was decreased with the increase of approach temperature difference and with the decrease of pipe wall thickness. In addition, when the SWHE was applied to the GHP system, the temperature of vertical GHE was more stable than that of standalone GHE system.

Analysis of Design Parameters for Power Plant Breakwater Channels Using Geotextile Containment (지오텍스타일 컨테인먼트를 활용한 발전소 방파수로 설계인자 분석)

  • Kim, Sung-Hwan;Oh, Young-In
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.3
    • /
    • pp.1-7
    • /
    • 2008
  • The geotextile tube shall be sewen with geotextile longitudinally in the shape of hose and it shall be filled hydraulically through filling ports at the proper intervals to construct structure. Geotextile container shall be sewen after spreading of geotextile on the split barge and sealed shut after the filling soil, and then moved and positioned at the required position. And the geotextile container passes through the bottom of barge by opening split barge and drops to the seabed to form structure. This structure for the ${\bigcirc}{\bigcirc}$ project, UAE and we would propose that geotextile containment for core material of power plant breakwater to be constructed for lower bunds with containers up to -4.0m and do upper parts with the structures of tube up to 0.0m. For the application of proposed geotextile containment, review on stability of breakwaters and design consideration were adopted. The evaluation on stability of geotextile containment was classified by 3 items, internal design consideration for material selection, reviews on stability for individual and global structure. In this research, the geothermal analysis was performed to estimate the geothermal behavior of central breakwater. Central breakwater is located boundary of intake and outfall channel, it is mean that the central breakwater is thermal boundary of intake low temperature sea water and outfall high temperature sea water. Therefore, it is required to be designed a low permeability to ensure no mix of intake and outfall waters.

  • PDF