• Title/Summary/Keyword: geotechnical behavior

Search Result 1,589, Processing Time 0.056 seconds

Analysis of Characteristics of Connected-pile Foundations for Transmission Tower according to Changes of Load and Connection Beam Conditions in Clay (점토지반에서 하중특성 및 연결보조건에 따른 송전철탑용 연결형 말뚝기초의 특성 분석)

  • Kyung, Doohyun;Lee, Junhwan;Paik, Kyuho;Kim, Youngjun;Kim, Daehong
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.10
    • /
    • pp.5-18
    • /
    • 2013
  • The differential settlement between the foundations causes the critical damage on the transmission tower constructed in soft ground. Connected-pile foundation for transmission tower structures is an option to prevent the differential settlement. It consists of main foundations and connection beams that are placed between the individual foundations at each corner of tower. In this study, 24 model pile load tests were conducted at a construction site in jeonlabuk-do to investigate the effects of the connection beams on transmission tower foundation. In model tests, various load conditions and connection beam conditions were considered. As the test results, the displacements of connected-pile foundation differed in accordance with load directions. The settlements of connected-pile foundation decreased with the increased stiffness of connection beams, lateral load capacity decreased in accordance with load height, and the lateral load capacity on the failure criteria was similar regardless of load direction.

The Analysis of Skin Friction on Small-scale Prebored and Precast Piles Considering Cement Milk Influence (시멘트풀의 영향을 고려한 축소모형 매입말뚝의 거동분석)

  • Park, Jong-Jeon;Jung, Gyung-Ja;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.1
    • /
    • pp.5-15
    • /
    • 2017
  • Skin friction may be one of the most critical factors in designing the prebored and precast pile. Special attention was given to the interface behavior of cement milk-surrounding soil during the installation of prebored and precast pile. Small-scale field model pile test was conducted for the case of single pile. The size and geometry of the small-scale field model piles were designed with pile length 1.3m, boring diameter 0.067 m. Quick maintain-load test was conducted for the cases of boring diameter 150, 125, 90, 86, 74 mm and water-cement ratio 90, 70, 60%. It was shown that the bearing capacity of the pile increased as the cement-water ratio and cement milk thickness increased. Considering the scale effect between the small-scale model test and the actual construction site, it was found that cement milk thickness of 0.1~0.4D (50~200 mm) was reasonable for the stability of the structure. Also, the proper cement paste water / cement ratio was about 70% when considering the results of this study and quality control.

Evaluation Method for Uplift Load-carrying Capacity of Inclined Group Micropiles in Dense Sand (조밀한 사질토지반에서 경사로 설치된 그룹 마이크로파일의 인발지지력 평가방법)

  • Kyung, Doohyun;Kim, Garam;Kim, Incheol;Lee, Junhwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.1
    • /
    • pp.67-77
    • /
    • 2017
  • In the present study, uplift load carrying behavior of micropiles with installation angle and pile spacing was investigated based on uplift load tests using single and group micropiles. In addition, evaluation methods of uplift load carrying capacity of group micropiles were proposed based on FHWA (2005) and Madhav (1987) and they were compared with test results to confirm the validity of proposed methods. From the test results, uplift load carrying capacities of single and group micropiles increased with the increase of the installation angle up to $30^{\circ}$, whose values also increased slightly with increasing pile spacing. For the proposed method based on FHWA (2005), the estimated values were similar to measured values up to $15^{\circ}$ of installation angle and 5D of pile spacing. For the proposed method based on Madhav (1987), on the other hand, it was observed that the estimated values were in good agreement with measured values in all installation conditions.

Relative Density and Stress-Dependent Failure Criteria of Marine Silty Sand Subjected to Cyclic Loading (반복하중을 받는 해양실트질 모래의 상대밀도에 따른 응력기반 파괴기준)

  • Ko, Min Jae;Son, Su Won;Kim, Jin Man
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.1
    • /
    • pp.79-91
    • /
    • 2017
  • An experimental study has been conducted by using the Cyclic Direct Simple Shear apparatus to evaluate the influence of average and cyclic shear stresses on the undrained shear failure behavior of marine silty sand considering various relative densities. The obtained results show that despite using different relative densities, similar trends were gained in the cyclic shear deformation. Moreover, the cyclic shear deformation is affected mainly by the average and cyclic shear stresses. The number of cyclic loads for failure is significantly affected by the cyclic shear stress ratio and relative density, and is less affected by the average shear stress ratio. The proposed three-dimensional stress-dependent failure contour can be used effectively to assess the soil shear strength considering various relative densities in the design of foundation used for offshore structures.

Behavior of Floating Top-Base Foundation on Soft Soils by Laboratory Model Tests (실내모형실험을 통한 연약지반에서 부양형 팽이기초의 거동)

  • Chung, Jin-Hyuck;Chung, Hye-Kwun;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.5-15
    • /
    • 2011
  • This research performed the laboratory model tests for Top-Base Foundation developed in Japan and Floating Top-Base Foundation developed in Korea on the typical clayey soft soils, namely, clay, clayey silt and clayey sand. The performances of the two types of top-base foundation were compared with each other and evaluated by measuring load-settlement, heaving of foundation side, ground stress distribution in this model tests. The change of settlement caused by the increase of top base width was also analyzed. As a result of the model tests, Floating Top-Base Foundation showed better performance in bearing capacity improvement, settlement decrease, stress dispersion effect and lateral confinement force. And settlement caused by the increase of top base width converged to a regular value from $5{\times}5$ layout of the width.

Analysis of Saturation and Ground Water Level at Embankment by TDR Sensor (TDR센서를 이용한 제방의 포화도 및 지하수위 해석)

  • Kim, Ki-Young;Han, Heui-Soo;Lee, Jae-Ho;Park, Min-Cheol
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.63-72
    • /
    • 2011
  • The measured ground water behavior by TDR (time domain reflectometer) sensors were analyzed by the data filtering technique such as moving average method and Fourier transform, and the ground water level and unsaturated zone were tried to be determined numerically. At first, the variation of TDR data according to the saturation degree was measured by lab test, which is translated as a function of saturation degree. Then, changes of ground water level and lateral seepage in field conditions were simulated using acrylic pipe, and the measured data were analyzed to make calibration curve. Furthermore, TDR sensors were installed into the in-situ embankment to insure the field application. The saturation degree, unsaturated and dried zones were determined from the measured data.

Model Tests of Pile Groups in Sand (실내모형실험을 통한 군말뚝기초의 거동분석)

  • 정상훈;정상섬
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.193-205
    • /
    • 2001
  • In this study the behavior of pile groups is investigated experimentally. Special attention is given to the load transfer characteristics of pile groups and to the evaluation of the group effects under vertical and horizontal loadings. In the laboratory experiments, vertical and lateral loadings were imposed on model piles in sand. Model piles made of PVC embedded in Joomoonjin sand were used in this study. Pile arrangements($2\times2,\; 3\times3$) and pile spacings(2.5D, 5.OD, 7.5D) were considered. Load-transfer curves(t-z, q-z and p-y curves), load-deflection curves and group interaction factors were obtained from the experimental results. The group interaction factors under both vertical and horizontal loadings were proposed for the cases of $2\times2\; and\; 3\times3$ pile groups with varying ratios of pile spacings. p-multipliers in this study were found for the individual piles in $2\times2\; and\; 3\times3$ pile groups.

  • PDF

Behavior of Small-Scale Pile Group Under Vertical Loading (연직하중을 받는 소규모 무리말뚝의 거동)

  • 이영남;이승현;박영호
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.37-46
    • /
    • 2001
  • Pile load tests were carried out to investigate the contribution of the pile cap to the carrying capacity of a pile group and load transfer characteristics of piles in the group. A group of 24 piles$(4 \times6 array)$ of 92.5mm diameter steel pipe were installed to the depth of 3m fron the ground surface, the top of weathered rock. A maximum load of 320ton was applied to the pile cap, $1.5\times2.3m$, in contact with the ground surface. At the maximum load of 320ton, the pile cap has carried 22% of the total load. Average ultimate capacity of pile in the pile group was estimated to be 16.4ton, substantially higher than that of single pile, installed at the corner and tested before pile cap construction. For the same magnitude of settlement, the pile in the center carried less load than the pile at the perimeter due to strain superposition effect. Piles in the group showed almost constant contribution(approx. 60%) of side friction to the total capacity for all of the loading stages, while that of single pile decreased from 82% to 65%.

  • PDF

Characteristics of Pullout Behavior of Soil Improvement(SI) Anchor (지반개량(SI)앵커의 인발거동특성)

  • 임종철;홍석우;송무효;강낙안
    • Geotechnical Engineering
    • /
    • v.14 no.6
    • /
    • pp.139-151
    • /
    • 1998
  • SI anchor means the soil improvement anchor. The ground for supporting anchor is improved by JSP, and as a result, SI anchor body has about 80cm in diameter. SI anchor shows high pullout resistance by the frictional force between anchor body and ground, and the bearing capacity of anchor body. Especially the frictional force increases very much with increasing diameter of anchor body improved by JBP. In this study, model and field tests are made to analyse the mechanism of pullout resistance of SI anchor. Through model tests for the SI anchor in air dried sandy ground, strain fields of ground around SI anchor surface are analysed by a photo analysis method using the latex membrane on the wall of soil tank. The results of field tests are analysed by the strains measured by 10 strain gages attached on the inner wall of specially designed PVC pipe embedded in anchor body, and the strains of anchor body are also measured in the model tests.

  • PDF

Assessment of Shear Band Characteristics in Granular Soils Using Digital Image Analysis Technique for Plane Strain Tests (평면변형률 시험에서 이미지 해석을 통한 사질토의 전단면 특성 평가)

  • Jang, Eui-Ryong;Jung, Young-Hoon;Kim, Jun-Young;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.4
    • /
    • pp.51-65
    • /
    • 2011
  • Shear banding, the localization of deformation into thin zones, has a quite practical relevance, as stability and deformation characteristics of earth structures are controlled by the soil behavior within the shear band. In this study, for understanding occurrence and developed pattern of shear band, plane strain compression tests were performed on three soils with different particle-size distribution under various conditions. Digital images were captured during the experiments; then, deformation of a specimen was evaluated by digital image analysis technique. The characteristics of a shear band were evaluated from the state shortly after post-peak occurrence to critical state. Additionally, the statistical procedure was developed to determine the reasonable thickness of a shear band.