• Title/Summary/Keyword: gas-discharge

Search Result 1,514, Processing Time 0.028 seconds

Research and Development of High Performance 50-inch HD Plasma Display Panel

  • Choi, Kwang-Yeol;Min, Woong-Kee;Rhee, Byung-Joon;Ahn, Byung-Nam;Kim, Je-Seok;Moon, Won-Seok;Park, Min-Soo;Ryu, Byung-Gil;Kim, Sung-Tae;Ahn, Young-Joon;Yang, Sung-Soo;Kim, Kyung-Tae;Lee, Kyu-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1547-1550
    • /
    • 2008
  • We are suggesting a new index to represent the performance of PDP, such as Specific Performance Index (SPI) that includes luminous efficacy and panel reflectance. High Xe gas mixture and low panel capacitance are well known as key factors to improve luminous efficacy of PDP [1]. However, higher driving voltage and longer discharge time lag is an obstacle when applying these technologies. Modified cell design, new materials and driving waveform enable us to overcome these obstacles. High efficient phosphor is also a key material to improve luminous efficacy. Phosphors coated with pigment are used to reduce panel reflectance. High performance 50-inch HD PDP with luminous efficacy of 2.3 lm/W has been developed.

  • PDF

Characteristic evaluations and production of triode magnetron sputtering system (Triode magnetron sputtering system의 제작 및 특성평가)

  • Kim, H.H.;Lee, M.Y.;Kim, K.T.;Yoon, S.H.;Yoo, H.K.;Kim, J.M.;Park, C.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.787-790
    • /
    • 2003
  • A rf triode magnetron sputtering system is designed and installed its construction in vacuum chamber. In order to calibrate the rf triode magnetron sputtering for thin films deposition processes, the effects of different glow discharge conditions were investigated in terms of the deposition rate measurements. The basic parameters for calibrating experiment in this sputtering system are rf power input, gas pressure, plasma current, and target-to-substrate distance. Because a knowledge of the deposition rate is necessary to control film thickness and to evaluate optimal conditions which are an important consideration in preparing better thin films, the deposition rates of copper as a testing material under the various sputtering conditions are investigated. Furthermore, a triode sputtering system designed in our team is simulated by the SIMION program. As a result, it is sure that the simulation of electron trajectories in the sputtering system is confined directly above the target surface by the force of $E{\times}B$ field. Finally, some teats with the above 4 different sputtering conditions demonstrate that the deposition rate of rf triode magnetron sputtering is relatively higher than that of the conventional sputtering system. This means that the higher deposition rate is probably caused by a high ion density in the triode and magnetron system. The erosion area of target surface bombarded by Ar ion is sputtered widely on the whole target except on both magnet sides. Therefore, the designed rf triode magnetron sputtering is a powerful deposition system.

  • PDF

Fabrication and Characteristics of Photoconductive Amorphous Silicon Film for Facsimile (팩시밀리용 비정질 실리콘 광도전막의 제작 및 특성)

  • Kim, Jeong-Seob;Oh, Sang-Kwang;Kim, Ki-Wan;Lee, Wu-Il
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.6
    • /
    • pp.48-56
    • /
    • 1989
  • Contact-type linear image sensors for facsimile have been fabricated by means of rf glow discharge decomposition method of silane. The dependence of their electrical and optical properties on rf power, $SiH_4$ flow rate, ambient gas pressure, $H_2SiH_4$ ratio and substrate temperature are described. The a-Si:H monolayer demonstriated photosensitivity of 0.85 and $I_{ph}/I_d$ ratio of 100 unger 100 lux illumination. However, this monolayer has relatively high dark current due to carrier injection from both electrodes, resulting in low $I_{ph}/I_{dd}$ ratio. To suppress the dark current we have fabricated $SiO_2/i-a-Si:H/p-a-Si:H:B$ multilayer film with blocking structure. The photocurrent of this multilayer sensor with 6 V bias became saturated ar about 20nA under 10 lux illumination, while the dark current was less than 0.2 nA. Moreover, the spectral sensitivity of the multilayer film was enhanced for short wavelength visible region, compared with that of the a-Si:H monolayer. These results show that the fabricated photocon-ductive film can be used as the linear image sensor of the facsimile.

  • PDF

A Study on the Improvement Plans of Energy Performance in University Building through the Analysis of Energy (에너지 해석을 통한 대학건물의 에너지 성능개선 방안에 관한 연구)

  • Jung, Jae-Woong;Kim, Dong-Woo;Seok, Ho-Tae;Yang, Jeong-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.50-60
    • /
    • 2010
  • Today, the amount of energy consumption in the university campuses is huge. The effort for the energy consumption reduction in university campuses is certainly needed by the following reason; first, contribution to the greenhouse gas discharge reduction demand. Second, energy cost reduction in university campus. Third, contribution to the improvement of the social awareness as the maximum higher educational institutions. The energy consumption analysis of current situation has to be executed for the energy consumption reduction in university campus. The energy reduction possibility in which it exists in university campuses can be understood through the energy consumption analysis. And the application is possible as fundamental data of the policy establishment for the effective energy reduction in university campuses. Especially, the best way to reduce the energy consumption in university campuses that is the energy consumption reduction of buildings. Accordingly, this study derived the plans for improving the performance of energy in the university building by analyzing case study, so this study analyzed the performance of energy for the university building through VE, a program for the analysis of building energy. Based on this result, this study classified the plans improving the efficiency of energy in university building into the plan for passive control and active control respectively, and suggested some concrete plans, and finally evaluated the performance of decreasing energy consumption for each plan.

Associations between Early Hyperoxia and Long Term Neurologic Outcome in Acute Carbon Monoxide Poisoning (급성 일산화탄소 중독환자에서 병원 전 고산소혈증이 장기 신경학적 예후에 미치는 영향)

  • Kim, Ju Chan;Chun, Byeong Jo;Moon, Jeong Mi;Cho, Young Soo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.18 no.1
    • /
    • pp.18-25
    • /
    • 2020
  • Purpose: We studied the impact of arterial oxygen tension (PaO2) on the long term neurologic outcome in patients with acute carbon monoxide poisoning. Methods: The study population included 311 patients who presented to emergency department with acute CO poisoning from January 2015 to January 2018. These patients underwent arterial blood gas testing at the time of presentation. The baseline demographic, clinical, laboratory, and clinical outcome data were recorded. The primary outcome of interest was the long term neurologic status. Results: The normoxia group was significantly older and it had a higher incidence of diffusion weighted MRI abnormality, and this group needed multiple HBO sessions compared to the group with moderate or severe hyperoxia. Also, the incidence of altered mentality at discharge was higher in the normoxia group than that of the moderate hyperoxia group. The incidence of a poor long term neurologic outcome was 11.3%. The incidence of a poor long term neurologic outcome decreased as the PaO2 increased. The PaO2 was significantly lower in patients with a poor long term neurologic outcome than that of the patients with a good outcome 198 (165.2 to 231.1) mmHg in the good outcome group vs. 154 (119-162) mmHg in poor outcome, p<0.001). In multivariate logistic regression analysis, PaO2 was selected as an independent factor of the poor long-term neurologic outcome (OR 0.981 (95% CI: 0.968 to 0.995)) Conclusion: Higher PaO2 was independently associated with a lower incidence of a poor long-term neurologic outcome.

Congenital Esophageal Atresia and Tracheoesophageal Fistula: Report of Two Cases (선천성 식도폐쇄 및 기관식도루: 2례 보고)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.6 no.1
    • /
    • pp.89-94
    • /
    • 1973
  • Esophagel atresia and tracheoesophageal fistula may occur as separate entities but usually occur in combination. First described by Durston in 1670, esophageal atresia was not successfully treated until 1939 when Ladd in Boston and Leven in St. Paul obtained the first survivors utilizing the methods of gastrostomy, esophagostomy and extrapleural ligation of the tracheoesophageal fistula as multiple operations which required months of hospitalization. Two years later Cameron Haight performed the first successful primary repair and afterward about 2000 cases of esophageal atresia with distal tracheoesophageal fistula reported in the world. In Korea, there appeared about 27 cases in the literature and 8 successful repaired cases noted in these year. Anther report two cases of esophageal atresia, of which one case was successfully treated with Haight`s method. Case 1.: Normal full term delivered boy with chief complaints of respiratory difficulty and persistent drooling with chocking, 3. lkg, was admitted with emergency 5 hours after delivery. Physical findings revealed no specific abnormal signs except distended abdomen and grunting respiration. Esophagograrn and bronchogram revealed proximal esophageal atresia and distal tracheoesophageal fistula proximal to the carina. Parent refused operative therapy and patient died 24 hours after discharge. Case 2. :3. lkg. normal full term delivered girl was admitted 4 days after delivery with chief complaints of regurgitation after feeding, chocking, cyanotic spell and fever since the day after delivery. Physical examination revealed persistent drooling, grunting respiration, and fever with moderate dehydration. Tracheoesophageal suction and fluid therapy with antibiotics improved her condition and subsided ]pneumonic condition. Esophagogram revealed markedly dilated proximal esophagus as blind loop and stomach distended with gas, and repairing operation as Haight`s method was performed on the 7th day after delivery. Patient tolerated all the operative procedure well and recovered uneventfully. Esophagogram on the 7th postoperative day showed passage of the lipiodol through the anastomotic side with moderate stricture,and feeding permitted. Patient tolerated all the feeding amount well and discharged on the 11th postoperative day. Followup revealed intermittent regurgitation after feeding and corrected with bougination.

  • PDF

Thermal-Hydraulic Analysis of Pipeline Transport System for Marine Geological Storage of Carbon Dioxide (이산화탄소 해양지중저장 처리를 위한 파이프라인 수송시스템의 열-유동 해석)

  • Huh, Cheol;Kang, Seong-Gil;Hong, Sup;Choi, Jong-Su;Baek, Jong-Hwa
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.88-94
    • /
    • 2008
  • The concentration of atmospheric carbon dioxide (CO2), which is one of the major greenhouse gases, continues to rise with the increase in fossil fuel consumption. In order to mitigate global warming the amount of CO2 discharge to the atmosphere must be reduced. Carbon dioxide capture and storage (CCS) technology is now regarded as one of the most promising options. To complete the carbon cycle in a CCS system, a huge amount of captured CO2 from major point sources such as power plantsshould be transported for storage into the marine or ground geological structures. Since 2005, we have developed technologies for marine geological storage of CO2,including possible storage site surveys and basic design of CO2 transport and storage process. In this paper, the design parameters which will be useful to construct on-shore and off-shore CO2 transport systems are deduced and analyzed. To carry out this parametric study, we suggested variations in thedesign parameters such as flow rate, diameter, temperature and pressure, based on a hypothetical scenario. We also studied the fluid flow behavior and thermal characteristics in a pipeline transport system.

Inhalation Sedation with Nitrous Oxide in Dental Treatment (Nitrous Oxide를 이용한 흡입진정)

  • Yoon, Byung-Bae
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.2 no.1 s.2
    • /
    • pp.1-6
    • /
    • 2002
  • The usage of nitrous oxide is increased for the anxious patient to dental treatment. There are two methods to induce the sedation during dental treatment. One is sedation with drugs the other no need of drugs. We discussed here about sedation with drugs. The methods of drug administration are oral, intramuscular, intravenous, inhalation. The method of oral administration of drugs are convenient to patient and doctor but poor controllability. Intramuscular method is a parenteral technique that maintains several advantages over the enteral technique. However its pales in comparison to other parenteral technique. Intravenous method represents most effective method of ensuring predictable and adequate sedation in all patients. But it has inability to reverse the action of drugs after they have been injected except some drugs (e.g., narcotics and benzodiazepine). A variety of gaseous agents may be administered by inhalation to produce sedation. In dental practice, the inhalation administration of gas means use of nitrous oxide. There are many advantages of nitrous oxide administration. First, very short latent period and rapid onset of drug action which lead to possible titration of drug concentration. With nitrous oxide, clinical effects may become noticeable as quickly as 15 to 30 seconds after inhalation. Recovery from inhalation sedation is also quite rapid. In out patient dental practice rapid recovery is very important because it permit to discharge the patient without escort and the patient return to their ordinary life without limit. To success the conscious sedation with nitrous oxide, the administrator should be keep the mind that always titration of nitrous oxide concentration during induction and treatment. Careful observation need during treatment to prevent oversedation because the adequate nitrous oxide concentration to patients changed by environmental stress. Always begins with 100% oxygen and ends with 100% oxygen to prevent diffusion hypoxia which rare in clinical practice.

  • PDF

A Stduy on Model Development of Boiler Combustion System on Coal Fired Power Plant (석탄화력발전소 보일러 연소계통의 모델개발에 관한 연구)

  • Moon, Chae-Joo;Kim, Yong-Gu;Chung, Hwan-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.65-73
    • /
    • 2004
  • The bolier systems of coal fired power plants are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems, dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. The boiler system consists of air/gas system and water/steam system. Due to recent reinforcement of environmental regulation on pollutant discharge and requirements of design validation on properites of boiler, the commercial programs are used for the analysis of boiler system. This paper addressed to the development of model using MMS(Modular Modeling System) developed by EPRI(Electric Power Research Institute) as the simulation tool. The developed model using MMS is tested for the design and local data on boiler combustion system of korea standard coal fired power plant boiler. The simulation results show that the developed model well reproduces responses of the combustion system with less than ${\pm}$5% error under steady state and transient state conditions. The developed model for analysis of the combustion system in this paper is general and applicable to any type of coal fired power plant.

An experimental study on development of water mist fire-fighting systems for Ro-Ro spaces (Ro-Ro 구역용 미분무 소화설비의 개발을 위한 실험적 연구)

  • Kwark, Ji-Hyun;Kim, Young-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.946-952
    • /
    • 2013
  • Large scale fire tests were conducted to develop water mist nozzles as a component of fixed water- based fire fighting systems for Ro-Ro spaces and special category spaces. Fire scenarios for this system consist of two cases which are for cargo fire in a simulated truck and for passenger vehicle fire, and each case has 3 different tests according to the position between fixed water mist nozzles and fire source. Every experiment proceeded for 30 minutes and acceptance criteria were based on gas temperature, fuel package's damage and ignition of targets. This study primarily dealt with the experimental results of cargo fire and focused on fire suppression capability in accordance with discharge pressure, flow rate and flow characteristics like swirl and penetration of the developed water mist nozzles. It appeared that low pressure water mist nozzles with about 40 L/min were able to control fire occurred in Ro-Ro spaces.