• Title/Summary/Keyword: gas storage

Search Result 1,424, Processing Time 0.035 seconds

Structural Analysis on A Steel Roof LNG Storage Tank (강재 지붕형 LNG 저장탱크 구조안전성평가)

  • Lee, Seung-Rim;Park, Jang-Sik;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.40-44
    • /
    • 2009
  • This is a comparative structural analysis for a steel roof LNG storage tank that has some advantages relatively in designing larger scale tanks and construction cost, etc. compared with a conventional concrete roof LNG storage tank as the capacity of LNG storage tanks is bigger. Structural analysis was performed on a 200,000$k{\ell}$ steel roof LNG storage tank and a concrete of the same capacity in condition of three critical load combination cases, a normal operation, a LNG spillage and seismic case by using finite element method. And comparative structural safety evaluation was carried out by using strength ratio in places of concrete wall, foundation and roof with a quantitative method.

  • PDF

Program Development on the Thermofluidodynamic Analysis of LNG Storage Tanks (LNG 저장탱크의 종합 열유동 해석프로그램 개발)

  • Kim Hoyeon;Choi Sunghee;Bak Young;Lee Junghwan;Yoon Ikkeun;Kim Donghyuk;Ha Jongmann;Joo Sangwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.52-61
    • /
    • 2001
  • Cryogenic LNG(Liquefied Natural Gas) which is stored in the cylindrical storage tanks of $100,000m^3$ has very complex flow phenomena and the changes of thermal properties with exterior conditions and operation modes. These complex thermofluid behaviors are affected by the storage, exterior conditions of LNG, design specifications and heat transfer characteristics of tanks. Also, those have influence on the stable storage and supply of LNG in the storage tanks. Thus this study peformed the analysis on the 2-D heat transfer of the tank with exterior conditions, on the Cool Down Process in order to cool down the LNG Storage Tank at the initial normal state, and on the Filling Process considered for incoming and rising of LNG. The analysis on the Mixing LNG Storage was studied too. At last, the visualized program on the complex thermofluidodynamic analysis was developed on the basis of the above analyses. The development of this program becomes to be used to the basic design of the commercial tanks as well as to assure technical skill of the analysis on the thermal stability of the stored LNG in the LNG Storage Tank.

  • PDF

Evaluation of Structural Safety and Leak Test for Hydrogen Fuel Cell-Based Truck Storage Systems (수소트럭 수소저장시스템에 대한 구조안전성 및 기밀성능평가)

  • Kim, Da-Eun;Yeom, Ji-Woong;Choi, Sung-Joon;Kim, Young-Kyu;Cho, Sung-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.11
    • /
    • pp.1-7
    • /
    • 2020
  • Recently, hydrogen has gained considerable attention as an eco-friendly fuel, which helps in reducing carbon dioxide content. Specifically, there is a growing interest in vehicles powered by a hydrogen fuel cell, which is spotlighted as an environmental-friendly alternative. A hydrogen transport system, fuel cell system, fuel supply system, power management system, and hydrogen storage system are key parts of a hydrogen fuel cell truck. In this study, a hydrogen storage system is built and analyzed. The expansion length of the storage vessel at maximum operating pressure (87.5 MPa) was calculated with ABAQUS, and then the optimized system was designed and built. The leak and bubble tests were performed on the built storage system. The leakage of the system was measured to be under 5 cc/hr. Hence, it can be used as a research test for the safety evaluation of leading systems of hydrogen fuel-powered commercial vehicles.

The Optimal Design of Explosion Prevention for LPG Storage Tank (폭발방지를 고려한 LPG 저장탱크 최적설계)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Son, Seok-Woo;Lim, Jae-Ki
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.949-952
    • /
    • 2010
  • The utilization of LPG(Liquefied Petroleum Gas) is increasing as an environmental-friendly fuel in all countries making green growth new paradigm, and use of gas is spread fast as motor fuels to decrease air pollution. Loss of lives by explosion and fire is happening every year as gas use increases, and gas accident in large scale storage property is causing serious problems socially. To minimize this problem, underground containment type storage tank is being presented as an alternative recently. In this study, to minimize explosion occurrence in underground containment type storage tank, the suitable storage tank is designed to consider explosion prevention that makes exposure surface area minimize in confined contents volume and flame to construct storage tank by the most suitable condition in the underground containment room. As a result of the design of storage tank having the most suitable condition by this research, underground containment space was minimized on diameter 3m, length 4.83m in 20 tons storage tank and its safety was improved as exposure surface area in flame decreased by 89.4%, compared with the existent storage tank.

  • PDF

A Development of Condition Evaluation Standard Considering Structural Characteristic for Members of LNG Outer Storage Tanks (LNG 외조 저장탱크의 구조적 특성을 고려한 상태평가 기준 개발)

  • Choi, Kyoung-Jae;Seo, Chang-Joo;Kim, Young-Gu;Jo, Young-Do;Kim, Jung-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.64-69
    • /
    • 2017
  • South Korea is the world's second-largest importer of LNG and possess about 70 tanks which are in operation by 2017. Thirty years as the design warranty period have exceeded since LNG storage tanks as the core facility of LNG industry were constructed in 1986. The LNG storage tank is under precision safety diagnosis from 2014 due to urban gas business act amendment. There is no criteria of condition evaluation for outer tank of LNG storage tank at the time of precision safety diagnosis. Through analysis of structural characteristic of LNG storage tank and civil structure condition evaluation standards, the criteria of condition evaluation for main members was developed. The criteria of objective condition evaluation can improve safety and reliability of LNG storage tank and suggest matenance criteria.

Effects of Gas-absorbent on the Storage of Kimchi (김치 저장성에 미치는 가스 흡수제의 영향)

  • 윤경영;강미정;신승렬;윤광섭;김순동;김광수
    • Food Science and Preservation
    • /
    • v.5 no.4
    • /
    • pp.363-367
    • /
    • 1998
  • Kimchi attached gas-absorbent and unattached one were stored at 20$^{\circ}C$, examined for the storage effects by measuring changes of pH, acidity, CO$_2$ contents, total microbe and lactic acid bacteria. pH of kimchi attached KOH is higher than that of the others during storage. Acidity of kimchi attached KOH is lower than that of the others during storage. The CO$_2$ contents of kimchi used KOH as Bas-absorbent is 1.5 mg% at 6 days, after it's value is constant during storage. And the CO$_2$ content of kimchi attached gas-absorbent is lower than that of kimchi unattached gas-absorbent. Total microbe number of kimchi unattached gas-absorbent, treated Ca(OH)$_2$ and treated KOH are the highest value at 6, 6 and 8 days, respectively. Lactic acid bacteria number of kimchi is increased during storage and that of kimchi attached gas-absorbent is higher than that of kimchi unattached gas-absorbent.

  • PDF

A Numerical Study on Operating Characteristics of a Miniature Joule-Thomson Refrigerator

  • Hong, Yong-Ju;Park, Seong-Je;Choi, Young-Don
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.41-45
    • /
    • 2010
  • Miniature Joule-Thomson refrigerators have been widely used for rapid cooling of infrared detectors, optoelectronic device, and integrated circuits of micro electronics. The typical J-T refrigerator consists of the recuperative heat exchanger with the double helical tube and fin configuration, J-T nozzle, a mandrel, Dewar and a compressed gas storage bottle. In this study, to predict the thermodynamic behaviors of the refrigerator with a compressed gas storage bottle during the cool-down time, numerical study of transient characteristics for a J-T refrigerator was developed. A simplified transient one.dimensional model of the momentum and energy equations was simultaneously solved to consider the thermal interactions of the each component of the refrigerator. To account for effects of the thermal mass of the solid, the heat capacities of the tube, fins, mandrel and Dewar are considered. The results show the charged gas pressure of the gas storage bottle has significant effects on the performance of the J-T refrigerator. At the elevated gas pressure of the gas storage bottle, the large capacity of the compressed gas storage does not need to get the fast cool-down performance of the J-T refrigerator in the cool-down stage.

Physico-Chemical and Microbiological Changes during Storage of Fresh Ginseng (수삼저장중 이화학적 및 기생물학적 변화)

  • 오훈일;노해원;도재호;김상달;홍순근
    • Journal of Ginseng Research
    • /
    • v.5 no.2
    • /
    • pp.99-107
    • /
    • 1981
  • Physical, chemical and microbiological changes were periodically studied during six-month storage of fresh ginseng under N2, CO2 gas or subatmospheric pressure condition. The results were summarized as follows. 1. The moisture contents of fresh ginseng gradually decreased during the first 2-month storage and thereafter generally reached at equillibrium. 2. There was no significant change in the reducing sugar content in 1-month storage, followed by$.$a decrease in between 2-and 3-month storage. Thereafter, the reducing sugar content increased at the end of 4-month storage. 3. The total sugar content increased significantly during the first 3-month storage. Under CO2 and Nr gas storage, the total sugar content gradually decreased after 3-month storage, while no significant change was observed in the samples stored under subatmospheric Pressure. Amylase activity gradually decreased as storage period increased 4. The content of saponin decreased as storage period increased, but ginsengoide Rf, Rd, Rc and Rb2 increased significantly in 1-month storage. 5. Regardless of storage methods, sprouting of ginseng and growth of microorganisms were inhibited in all samples during the first 4-month storage. However, growth of microorganisms was observed in the rhizome and injured areas of ginseng after 5-month storage in the N2 and CO2 gas atmosphere.

  • PDF

Quality Changes of Chicken Breast Meat by Slow-Released ClO2 Gas Gel-Pack during Storage (서방형 이산화염소 가스 젤팩을 이용한 닭가슴육 저장 중 품질 변화)

  • Lee, Kyung-Haeng;Yoon, Ye-Ji;Kwon, Hye-Won;Lee, Bom;Kim, Hong-Gil
    • The Korean Journal of Food And Nutrition
    • /
    • v.31 no.1
    • /
    • pp.127-134
    • /
    • 2018
  • To prolong the shelf-life of chicken breast meat, samples were treated with gel packs containing slow-released chlorine dioxide ($ClO_2$) gas at 7~15 ppm for eight days at $4^{\circ}C$. The microbial, physicochemical properties and sensory evaluation of the treated samples were investigated. The total number of bacteria in the control increased during storage and showed 6.78 log CFU/g on the 8th day of storage, but $ClO_2$ gas treatments showed 6.24~6.58 log CFU/g at the same time. The initial pH of chicken breast meat was 6.00 and gradually increased during storage. And $ClO_2$ gas treatments did not show any significant difference from the control during storage period, but maintained a generally lower pH than that of the control. The lightness, redness, and yellowness during storage were not significantly different between the control and the 7~10 ppm $ClO_2$ gas treatments. However, as the storage period was increased, the redness of 15 ppm $ClO_2$ gas treatment was reduced. The cooking loss and shear force were not different between the control and $ClO_2$ gas treatments during the storage period. Volatile basic nitrogen (VBN) increased in the control from the 6th day of storage and 23.80 mg% in the 8th day of storage. However, VBN of $ClO_2$ treatments showed lower than that of the control. In the change of sensory evaluation during storage, 10 ppm $ClO_2$ treatment showed the highest preference in odor, appearance and overall acceptance during storage period.

An Analysis of Relationship between Cushion Gas and Gas Withdrawal in Depleted Gas Reservoir as a Gas Storage (고갈가스전의 가스저장전 전환 시 쿠션가스와 가스재생산율과의 관계 분석)

  • Han, Jeongmin;Kim, Joohyung;Sung, Wonmo
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.9-20
    • /
    • 2013
  • Depleted gas reservoir has been already explored and its geologic data, along with its reservoir properties, are already known through seismic exploration and drilling. Therefore it would be less difficult to develope a gas storage from depleted gas reservoir. Cushion gas which remains in the reservoir to maintain pressure affects withdrawal rate of working gas in underground gas storage. In this study, we attempted to investigate the relationship between cushion gas and withdrawal rate using a commercial simulator. From the analyses of the results, it is found that the minimum limit for a cycle of 5-month injection and 5-month withdrawal is 10 wells with 50% cushion gas, and 12 wells with 60% cushion gas for a cycle of 7-month injection and 3-month withdrawal.