A fault prevention diagnostic of power transformer using Frequency Response Analysis (주파수 응답 분석(FRA)을 이용한 전력용 변압기 고장예방 진단)

  • Cho, Yun-Haeng;Lim, Tae-Young;Kim, Jong-Seon;Kim, Gi-Il;Ahn, Kwang-Won;Lim, Seong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.463-464
    • /
    • 2011
  • Currently, different kinds of diagnosis and inspection technologies are applied to prevent the internal mechanical transformation of transformers. For example, examination of internal Partial Discharge of transformer, analysis of transformer oil gas, and measurement Frequency Response Analyzer(FRA) are used to diagnose defect. Especially, diagnosis technique through Frequency Response Analyzer(FRA) has been used and developed from 1960, when it was first introduced, till now to become an important tool to examine presence of defect and to prove quality of machines for the most electric machine producers electric power company in the world. However, diagnosis through FRA is still in introduction level in Korea and the application method for FRA is not established yet. For that reason, study about the application of domestic electric installation according to the FRA is needed. It is expected that the study play an important part in the prevention of defect due to the internal transformation of transformer by introducing measurement theory, providing measurement method, and analyzing application cases.

  • PDF

Hydrogen Gas Pick-Up of Al-alloy Melt During Lost Foam Casting (소실모형 주조시 알루미늄 합금 용탕의 수소 용해에 관한 연구)

  • Shin, Seung-Ryoul;Choi, Hyun-Jin;Lee, Kyong-Whoan;Lee, Zin-Hyoung
    • Journal of Korea Foundry Society
    • /
    • v.22 no.4
    • /
    • pp.167-173
    • /
    • 2002
  • The hydrogen gas pick-up problem that can occur during Lost Foam Casting was investigated by reduced pressure test and practical Lost Foam Casting. The proper test pressure of reduced pressure test was determined by experiments not to use polystyrene and gas contents of the melt were calculated from density measurement results. The results showed that the hydrogen pick-up increased with the increased amount of polystyrene that was replaced by melt. The hydrogen pick-up was larger in the case of no degassed melt than that of degassed melt. So the hydrogen pick-up depended on the initial hydrogen content of the melt and the contact time of the melt with the decomposed gas phase. The mold evacuation decreased the hydrogen pick-up and increased the flow length of melt during Lost Foam Casting. And the error of calculated hydrogen pick-up was calculated by numerical method.

Cure Characteristics, Physical Properties and Ozone Resistance of Butyl Rubber and EPDM Rubber Blends (Butyl고무와 EPDM고무 블렌드의 경화특성, 물리적 성질 및 내오존성)

  • Park, Chan-Young;Hwang, Young-Bea
    • Elastomers and Composites
    • /
    • v.46 no.4
    • /
    • pp.329-334
    • /
    • 2011
  • In general, butyl rubber(IIR : isobutylene isoprene rubber) has excellent gas permeability resistance and impact absorbance property as low resilience elastomer. In this experiment butyl rubber blends with EPDM(ethylene propylene diene monomer) were prepared by mechanical mixing method. Curing behavior, physical properties and ozone resistance etc. were subsequently examined. Measurement results of gas transmission rate test shows that butyl rubber contents above 50 wt% showed significant decrease in gas permeability resistant property. However, in butyl rubber/EPDM blend, EPDM contents above 25 wt% indicates no surface change due to improvement of ozone resistance under the condition of 50 pphm, $50^{\circ}C$, 120 hrs.

The analysis on TMA gas-sensing characteristics of ZnO thin film sensors (ZnO 막막 센서의 TMA 가스 검지 특성 분석)

  • 류지열;박성현;최혁환;김진섭;이명교;권태하
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.12
    • /
    • pp.46-53
    • /
    • 1997
  • The TMA gas sensors are fabricated with the ZnO-based thin films grown by a RF magnetron sputtering method. The hall effect measurement and AES analysis are carried out to investigate the effects of the sputtering gases and dopants which effect on the electrical resistivity and sensitivity to TMA gas. We measure the cfhanges of the surface carrier concentration, haall electron mobility, electrical resistivity, surface condition, and depth profile of the films. The ZnO-based thin film sensors sputtered in oxygen, or added with dopants showed a high sruface carrier concentration, film sensors sputtered in oxygen and doped with 4.0 wt.% $Al_{2}$O$_{3}$, 1.0 wt.% TiO$_{2}$, and 0.2 wt% v$_{2}$O$_{5}$ showed the highest surface carrier concentration of 5.952 * 10$^{20}$ cm$^{-3}$ , hall electron mobility of 176.7 cm$^{2}$/V.s, lowest electrical resistivity of 6*10$^{-5}$ .ohm.cm and highest sensitivity of 12. These results were measured at a working temperature of 300.deg. C to 8 ppm TMA gas.

  • PDF

Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System (조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..

Design of Gas Identification System with Hierarchical Rule base using Genetic Algorithms and Rough Sets (유전 알고리즘과 러프 집합을 이용한 계층적 식별 규칙을 갖는 가스 식별 시스템의 설계)

  • Bang, Yonug-Keun;Byun, Hyung-Gi;Lee, Chul-Heui
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1164-1171
    • /
    • 2012
  • Recently, machine olfactory systems as an artificial substitute of the human olfactory system are being studied actively because they can scent dangerous gases and identify the type of gases in contamination areas instead of the human. In this paper, we present an effective design method for the gas identification system. Even though dimensionality reduction is the very important part, in pattern analysis, We handled effectively the dimensionality reduction by grouping the sensors of which the measured patterns are similar each other, where genetic algorithms were used for combination optimization. To identify the gas type, we constructed the hierarchical rule base with two frames by using rough set theory. The first frame is to accept measurement characteristics of each sensor and the other one is to reflect the identification patterns of each group. Thus, the proposed methods was able to accomplish effectively dimensionality reduction as well as accurate gas identification. In simulation, we demonstrated the effectiveness of the proposed methods by identifying five types of gases.

A Study on the Quantitative and Evaluation Weights of National Greenhouse Gas Emission Factors in the Mineral Industry (광물산업의 국가온실가스배출계수 정량·평가항목 가중치에 관한 연구)

  • Yoon, Yoongjoong;Cho, Changsang;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.9 no.1
    • /
    • pp.81-90
    • /
    • 2018
  • "The Framework Act on Low-Carbon Green Growth" specifies the requirements for the development and verification of emission factors for establishing reliable national greenhouse gas statistics. The scope of the regulations covers the development and validation of energy, industrial processes, solvents and other product use, agriculture, land use, land use change and emission and absorption coefficients of the forestry and waste sector as defined in the 1996 IPCC Guideline and GPG 2000, The minerals sector to be covered in this study belongs to industrial processes. As a representative method for quantifying and evaluating GHG emission factors, there are emission grade quality grading and DARS (Data Rating Rating System) in the 'Procedures for Preparing Emission Factor Documents (1997)' reported by US-EPA. However, the above two methods are not specific and comprehensive, and lack the details for accurate emission factor verification. Therefore, there is a need for a method for verifying and quantifying certified greenhouse gas emission factors that reflects characteristics of each industry sector in Korea and accord with IPCC G/L and GHG target management. In this study, we conducted a weighted study on quantitative and evaluation lists of emission factor using questionnaires to develop a more accurate methodology for quantifying national greenhouse gas emission factors in the mineral sector. Quantification and evaluation of emission factor are classified into essential verification and quality evaluation. The essential verifications are : administrative compatibility, method of determining emission factors, emission characteristics, sampling methods and analysis methods, representativeness of data. The quality evaluations consisted of the quality control of the data, the accuracy of the measurement and analysis, the level of uncertainty, not directly affect the emission factor, but consisted of factors that determine data quality.

Determination of trace impurities of HFC-134a by gas chromatograph with atomic emission detector (GC/AED) (GC/AED를 이용한 HFC-134a의 미량 불순물 분석)

  • Kim, Myeongja;Lim, Jeongsik;Lee, Jinbok;Lee, Jeongsoon
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.240-251
    • /
    • 2017
  • 1,1,1,2-Tetrafluoroethane (HFC-134a), which is used as refrigerant in air conditioners, has been recently regulated as a greenhouse gas and is recommended for reuse by refining. It is very important to quantitatively analyze trace impurities present in the refrigerant to evaluate the criteria for reuse. In this study, trace impurities including C, H, Cl, and F, which are difficult to quantify because there are no reference materials, were quantitatively analyzed by a gas chromatograph-atomic emission detector (GC/AED); for this analysis, this was preceded by a qualitative analysis with a GC-mass selective detector (GC/MSD). In addition, the AED response was investigated using a hydrocarbon mixed reference material, which was proportional to the number of atoms in the component. Fifteen refrigerant components were detected as trace impurities in HFC-134a by qualitative analysis of trace impurities including C, H, Cl, and F in the samples. Based on the results of the qualitative analysis, quantitative analysis of trace impurities using AED showed that the highest mole fractions were for the $CHClF_2$ component ($45438.38{\mu}mol/mol$) in one sample and for the $C_2H_2ClF_3$ component ($1311.47{\mu}mol/mol$) in another sample. From this study, it has been shown that it is possible for this analytical method to be applied to the qualitative and quantitative analysis of trace compounds in refrigerants, which are difficult to quantify because of the absence of reference materials.

A Study on the Quantitative Recovery of Dissolved Inorganic Carbonates in Ground Water for Radiocarbon Measurement (방사성탄소 측정을 위한 지하수 중에 용존된 무기탄소 화합물의 정량적 회수 연구)

  • Chun, Sang-Ki;Woo, Hyung-Joo;Cho, Soo-Young;Kim, Nak-Bae;Lee, Jong-Dae
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.284-289
    • /
    • 1999
  • Dissolved inorganic carbonates in ground water were quantitatively recovered by using gas evolution method. Gas evolution method was found to be less time-consuming, less susceptible to the contamination fromatmospheric $CO_2$ and little affected by the sulfate ions in comparison to the direct precipitation method. Extraction efficiency of nearly 99% could be achieved by gas evolution method in two hours using recirculated gas at a sweeping rate of 4 liter per minute. Samples for carbon isotope fractionation study were collected in three fractions with collection times. The evolution time for the first fraction was one hours, and then second and third fractions were collected at intervals of 30 minutes, respectively. A small portion of each fraction was analyzed to evaluate ${\delta}^{13}C$ values, which were measured to be -7.9‰, -3.0‰ and +0,4‰ for the each fraction. The result clearly indicated that gas evolution method generates isotopically lighter carbon at the beginning of the purging process and heavier isotopes at the end. However, this isotope fractionation effect could be neglected by the almost complete recovery of carbonates.

  • PDF

A Study on the Developments of Emission Correction Formula and Emission Characteristics of Greenhouse Gas by 5-Cycle Mode (5-cycle 모드 특성에 따른 온실가스 배출특성 및 배출량 보정식 개발 연구)

  • Park, Jin-Sung;Lim, Jae-Hyuk;Lee, Min-Ho;Kim, Ki-Ho
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.94-100
    • /
    • 2017
  • Due to the environmental problems caused by the greenhouse effect, regulation of $CO_2$ emissions is getting stronger day by day. In paricular, regulations of automobiles $CO_2$ emissions are being strengthen. However, existing $CO_2$ measurement methods do not reflect the environment and operating conditions on actual roads. Emissions of $CO_2$ can be increased by various conditions such as environmental condition(temperature and humidity) and driver's tendency(aggressive and passive). Therefore it is necessary to reflect the conditions of various actual roads such as 5-cycle test method on behalf of the existing $CO_2$ emission measurement method. The 5-cycle measurement method has five test modes; FTP-75, HWFET, US06, SC03, Cold FTP-75. The method reflects the following three environments and operating conditions as compared to conventional method; Using heater at low temperature, Aggressive driving such as rapid acceleration or deceleration, Using air conditioner at high temperature. Because of these various conditions of each test cycle, the 5-cycle method can reflect actual environments and operating conditions. This paper attempt to analyze $CO_2$ emission characteristics based on the results measured through the 5-cycle mode and develop the correction formula that can derive the results of the 5-cycle test method using existing test methods. As a result, the developed correction formula is expected to reduce $CO_2$ emissions and cut down expense for testing 5-cycle mode.