• Title/Summary/Keyword: gas insulation

Search Result 539, Processing Time 0.034 seconds

A Study of the Insulation Characteristic in $CF_4$ Gas (시뮬레이션에 의한 $CF_4$ 기체의 전자수송특성)

  • Kim, Sang-Nam;Hwang, Cheong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.468-469
    • /
    • 2007
  • In this paper, the electron transport characteristics in $CF_4$ has been analysed over the E/N range 1~300[Td] by a two-tenn approximation Boltzmann equation method and by a Monte Carlo simulation. The motion has been calculated to give swarm parameters for the electron drift velocity, longitudinal diffusion coefficient, the ratio of the diffusion coefficient to the mobility, electron ionization and attachment coefficients, effective ionization coefficient, mean energy, collision frequency and the electron energy distribution function. The swarm parameter from the swarm study are expected to serve as a critical test of current theories of low energy electron scattering by atoms and molecules, in particular, as well as crucial information for quantitative simulations of weakly ionized plasmas.

  • PDF

The presumption that breakdown characteristics of Dry-Air used to the Neural Network (인공신경망을 이용한 Dry-Air 절연파괴 전압 추정)

  • Choi, Eun-Hyeok;Kim, Tae-Eun;Choi, Sang-Tae;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1428-1429
    • /
    • 2007
  • The paper used to the Neral Netwok for a forecasting conservation system. A neural network is a powerful data modeling tool that is able to capture and represent complex input/output relationships. The motivation for the development of neural network technology stemmed from the desire to develop an artificial system that could perform "intelligent" tasks similar to those performed by the human brain. The true power and advantage of neural network lies in their ability to represent both linear and non-linear relationships and in their ability to learn these relationships directly from the data being modeled. Form results of this study, the Neral Netwok is will play an important role for insulation diagnosis system of real site GIS and power equipment using Dry-Air gas.

  • PDF

A Result and Pattern of Dissolved Gases Analysis in Kepco (전력용 변압기 유중가스분석 결과와 동향)

  • Cho, Sung-Min;Kim, Jae-Chul;Kweon, Dong-Jin;Koo, Kyo-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.95-96
    • /
    • 2007
  • Dissolved gas analysis (DGA) is one of the most widely used diagnostic tools for detecting and evaluating faults in electrical equipment. However, interpretation of DGA results is often complex and should always be done with care, involving experienced insulation maintenance personnel. KEPCO (Korea Electric Power Cooperation) has been using DGA technique since KEPCO established the criteria of DGA in 1985. In this paper, we introduce the DGA criteria of KEPCO and analyze the result of DGA. Also we sort pattern in result of DGA. Then, relation between pattern and inner inspection was studied. 67 DGA data was used for analyzing pattern. Some patterns have something to do with cause of incipient fault.

  • PDF

Assessment of Insulation Condition for Generator Rotor Windings (발전기 회전자 권선의 건전성 평가)

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.59-60
    • /
    • 2006
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line shorted-turn diagnosis system. The permanent flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

Fluid Structure Interaction Analysis of Membrane Type LNG CCS Experiencing the Sloshing Impact by Impinging Jet Model (멤브레인형 LNG 화물창의 강도평가를 위해 적용된 분사모델을 이용한 유체구조 연성해석에 관한 연구)

  • Hwang, Se Yun;Lee, Jang Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.71-78
    • /
    • 2015
  • The reliable sloshing assessment methods for LNG CCS(cargo containment system) are important to satisfy the structural strength of the systems. Multiphase fluid flow of LNG and Gas Compressibility may have a large effect on excited pressures and structural response. Impinging jet model has been introduced to simulate the impact of the LNG sloshing and analyze structural response of LNG CCS as a practical FSI(fluid structure interaction) method. The practical method based on fluid structure interaction analysis is employed in order to evaluate the structural strength in actual scale for Mark III CCS. The numerical model is based on an Euler model that employs the CVFEM(control volume based finite element method). It includes the particle motion of gas to simulate not only the interphase interaction between LNG liquid and gas and the impact load on the LNG insulation box. The analysis results by proposed method are evaluated and discussed for an effectiveness of FSI analysis method.

Study of Fire Examples for Electrical Wire Short and Insulated Coating Melting by Heating Including Automotive Engine Room (자동차 엔진룸 관련 전기 배선의 단락 및 열에 의한 절연피복 용융에 대한 화재사례 연구)

  • Lee, Il Kwon;Kim, Young Gyu;Youm, Kwang Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.15-19
    • /
    • 2013
  • This paper is to analyze and study the cause of fire examples produced because of short phenomenon by electric connecting damage and contacting engine over-heating with combustible materials in engine room of vehicle. In the first example, it knew the fact that the fire produced by contacting with body of vehicle because of loosed of bracket bolt for wire fixing that installed on the transmission case the battery power cable supply the power from battery of engine room to starting motor. In the second example, it certified the fire by short phenomenon because of insulation tape melting wound wiring lined from battery to starting motor. In the third example, it sought for fire's cause that melting phenomenon the wire coating by overheated engine as the wire disconnected with connector by the vibration. Therefore, the fire of system including engine electric made in the danger the people in the car by failure of engine and other system. And than, the car's driver must manage and examine a vehicle conscientiously.

Investigation of the Coil Deforamtion of the Gas Turbine Generator Rotor Using Finite Element Analysis (유한요소해석을 이용한 가스터빈 발전기 로터의 계자권선 변형 해석)

  • Yun, W.N.;Park, H.K.;Kang, M.S.;Kim, J.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.95-101
    • /
    • 2009
  • The generator for gas turbine power generation consists of the rotor which generates magnetic field, the winding coil which is the path for the field current and the wedge and retaining ring which prevents the radial movement of the coil. Relatively severe deformation was observed at the coil end section during the inspection of the generator for peaking-load operation, and the thermal-electricity and the centrifugal force were evaluated by the simple modeling of the windings to find the cause. But the simulation stress was not sufficient to induce the coil plastic deformation. The analysis result seems to be applicable to the base-load generators which runs continuously without shut down up to a year, but there had been more deformation than simulated for the generator which is started up and shut down frequently. The cause of the coil deformation was the restriction of the expansion and shrinkage. The restriction occurs when the winding coil shrinks, and the stress overwhelms the yield stress and cause the plastic deformation. The deformation is accumulated during the start-ups and shut-downs and the thermal growth occurs. The factors which induce the coil restriction during the expansion and shrinkage should be reduced to prevent the unallowable deformation. The resolutions are cutting off the field current earlier during the generator shut-down, modifying the coil end section to remove the stress concentration and making the insulation plate inserted between the coil end section and the retaining ring have the constant thickness.

  • PDF

Fabrication of oxide semiconductor thin film gas sensor array (산화물 반도체 박막 가스센서 어레이의 제조)

  • 이규정;김석환;허창우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.3
    • /
    • pp.705-711
    • /
    • 2000
  • A thin film oxide semiconductor micro gas sensor array which shows only 60 mW of power consumption at an operating temperature of $300^{\circ}C$ has been fabricated using microfabrication and micromachining techniques. Excellent thermal insulation of the membrane is achieved by the use of a double-layer structure of $0.1\mum\; thick\; Si_3N_4 \;and\; 1 \mum$ thick phosphosilicate glass (PSG) prepared by low-pressure chemical-vapor deposition (LPCVD) and atmospheric-pressure chemical-vapor deposition (APCVD), respectively. The sensor array consists of such thin film oxide semiconductor sensing materials as 1 wt.% Pd-doped $SnO_2,\; 6 wt.% A1_2O_3-doped\; ZnO,\; WO_3$/ and ZnO. Baseline resistances of the four sensing materials were found to be stable after the aging for three days at $300^{\circ}C$. The thin film oxide semiconductor micro gas sensor array exhibited resistance changes usable for subsequent data processing upon exposure to various gases and the sensitivity strongly depended on the sensing layer materials.

  • PDF

Fabrication and yield improvement of oxide semiconductor thin film gas sensor array (산화물 반도체 박막 가스센서 어레이의 제조 및 수율 개선)

  • 이규정;류광렬;허창우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.2
    • /
    • pp.315-322
    • /
    • 2002
  • A thin film oxide semiconductor micro gas sensor array which shows only 60㎽ of power consumption at an operating temperature of 30$0^{\circ}C$ has been fabricated using microfabrication and rnicrornachining techniques. Excellent thermal insulation of the membrane is achieved by the use of a double la! or structure of 0.1${\mu}{\textrm}{m}$ thick Si$_3$N$_4$ and 1${\mu}{\textrm}{m}$ thick phosphosilicate glass(PSG) prepared by low pressure chemical vapor deposition(LPCVD) and atmospheric-pressure chemical-vapor deposition(APCVD), respectively. The sensor way consists of such thin film oxide semiconductor sensing materials as 1wt.% Pd-doped SnO$_2$, 6wt.% AI$_2$O$_3$-doped ZnO, WO$_3$ and ZnO. The thin film oxide semiconductor micro gas sensor array exhibited resistance changes usable for subsequent data processing upon exposure to various gases and the sensitivity strongly depended on the sensing layer materials. Heater Part of the sensor structure has been modified in order to improve the process yield of the sensor, and as a result of modified heater structure improved process yield has been achieved.

Analysis of Partial Discharge Characteristics in SF6 Gas Insulation (SF6 가스절연에서 부분방전의 특성분석)

  • Kim, Sun-Jae;Wang, Guoming;Park, Seo-Jun;Kil, Gyung-Suk;An, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.