• Title/Summary/Keyword: gas insulation

Search Result 539, Processing Time 0.024 seconds

The Analysis of PD Signal using Neural Network (신경회로망을 이용한 부분방전 신호의 패턴분석)

  • 김종서;박용필;천민우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.567-571
    • /
    • 2004
  • Recently, GIS(Gas Insulated Switchgear) has been recognizing of importance on development of diagnosis technique which is happened problem on confidence for a long time use. Therefore, the measurement and analysis of PD with prior phenomenon of insulation breakdown is used many method of diagnosis for GIS. In this paper, we simulate trouble condition in DS and analysis trouble signal to use electrical and mechanical methods, interpretation of detected signal has analysed with to use ø-q-n pattern and neural network. For this analysis, we have used the induction and AE(acoustic emission) sensors. For the simulation experiment, we make DS for 170 KV GIS and analyze the classification and characteristics of detected signals with the application of neural network algorithm.

A Study on the PD Detection Using a UHF Method in GIS (GIS에 있어서 UHF법을 이용한 부분방전 검출에 대한 연구)

  • Yoon, J.Y.;Jung, K.J.;Choi, J.G.;Kim, K.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2063-2065
    • /
    • 1999
  • PD pulses have about one nanosecond rise time in the $SF_6$ gas insulation. These pulses propagate through GIS chamber to PD sensors in the form of the electromagnetic radiation. In this paper, we investigated the characteristics of disc sensors and monopole antenna, by putting high frequency signals into the test cell in $SF_6$ gas by means of a Ins rise time pulse generator and 60Hz power supply respectively. Also, we measured PD quantity from the needle electrode and the location effect of output terminal beneath the disk sensors.

  • PDF

Analysis of electron transport characteristic in He gas by MCS (MCS에 의한 Helium 기체 중의 전자수송특성 해석)

  • Song, Byoung-Doo;Ha, Sung-Chul;Seo, Sang-Hyoen;Moon, Ki-Seok;Yoo, Hoy-Young;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1752-1754
    • /
    • 1998
  • Recently the research about electron transport characteristic and energy distribute function in mixture gases within Helium, has been used and developed widely as industrial quality improvement of extinguish characteristic, electrical dielectric strength ability of application of each species high voltage apparatus, gas plasma etching progress of work to use manufacture of semiconductor, thin film molding by CVD, insulation film to use ultra LSI, etc. This paper analyze electron transport characteristic in the range E/N $1{\sim}60$[Td], pressure $0.1{\sim}6.0$[Torr] by MCS. It is necessary to seek electron drift velocity, diffusion coefficient, lonization coefficients, characteristic energy, mean energy and electron energy distribution function as electron transport characteristic.

  • PDF

A Study on the Fire Safety Performance of Interior Surface Materials in a Building (건축물의 실내건축 재료에 관한 화재안전성 연구)

  • Seo, Su-Eun;Shin, Seung-Woo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.275-290
    • /
    • 2013
  • The main cause of building fire fatalities occur in the combustible material heat, smoke and toxic gases are. Building interior decoration, etc., especially as much of the harmful substances generated during combustion, and, used in domestic architecture wallpaper, ceiling, and other plastics, built-in foam insulation also analyzed recognition of fire hazards approach to test the conkalrorimiteo test, choedaeyeolbangchulryul through, chongbal heat, mass loss rate, generates carbon monoxide gas hazard ratio tests, analysis and evaluation rigid foam index testing the toxicity of hazardous material generated by performing a gas clean up and assess the material test results, the minimum order to provide data to quantify the risk of fire. Ensure fire safety of building materials, composite materials in order to test the various risk factors could be considered organic to the introduction of testing and evaluation is needed urgently.

  • PDF

A INSULATING DESIGN OF $SF_6$ GAS SEALING END OF CONDENSER CONE TYPE USED FOR 345KV OF CABLE (콘덴서 콘 방식의 345KV OF 케이블용 $SF_6$ 가스중 종단접속함의 절연 설계)

  • Kim, H.J.;Lee, S.C.;Oh, O.J.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1553-1555
    • /
    • 1994
  • In this paper, we describes the research in condenser cone of $SF_6$ gas sealing end for 345KV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory ana FEM. As a results. we have been designed the condenser cone and the inner insulation part of $SF_6$ seating end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone.

  • PDF

Development and Assessment of a Downdraft Gasifier for Biomass Gasification (하향식 바이오매스 가스화장치의 개발 및 평가)

  • Hong, Seong-Gu;Shim, Jae-Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.4
    • /
    • pp.89-97
    • /
    • 2008
  • A downdraft gasifier was manufactured for biomass gasification. The gasifier was designed based on the principles of gasification presented in previous studies. The pipes of 25mm diameter were used for both supplying air and discharging producer gas. Wood charcoals were mostly used for fuels. The concentration of CO ranged from 25 to 35%, comparable to the values presented in other studies. The temperature outside wall of the gasifier was measured up to $400^{\circ}C$, indicating a great heat loss. When glass wool was cover over the wall, some parts of wire mesh located in the bottom of the reactor were molten down. There were several modifications that should be made in order to improve its efficiency and obtain more stable continuous gasification, including insulation, reduction in pressure loss, durable bottom meshes, the optimum length of reaction part, and safety.

난연성 변압기기의 대용량화 현황

  • 허창수
    • 전기의세계
    • /
    • v.42 no.9
    • /
    • pp.28-37
    • /
    • 1993
  • 현재 기존 변압기의 문제점 해결과 도시공간의 이용 및 전력수요의 증가에 대처하기 위하여 난연성 변압기로서 SF$_{6}$gas변압기 및 액냉식 대용량 변압기의 개발 필요성이 크게 대두되고 있으나 중전기기 제작기술이 외국에 크게 의존하고 있으며 또한 연구개발비가 매우 크게 의존하고 있으며 또한 연구개발비가 매우 크게 소요되므로 일반기업체의 단독 개발은 매우 어려운 상태이다. 본 기술은 보유 및 연구를 하고 있는 외국회사는 5개사 정도이며, 현재 건식 변압기가 사용되는 장소의 전력소요가 증가하고 또한 변전소의 CGI(compressed gas insulation)화가 추진됨에 따라 수요는 상당히 증가할 것으로 생각되며 신규설치 및 기존변압기의 대체를 고려할 때 세계시장은 성장성 및 연속성이 있을 것으로 추정된다. 이 변압기는 아직 외국에서도 특수한 경우를 제외하고는 일반적으로 상품화까지 연구가 완료된 상태가 아니므로 기술도입이 어려웁고 또한 지금부터 같이 연구를 하면 기술격차를 줄일 수 있다고 생각되 기본설계, 제작 연구를 통하여 자체기술의 지속적 연구가 필요하다고 하겠다.

  • PDF

A Study of the Preventive Diagnostic Algorithm of Gas in Oil for Power Transformer (가스분석을 이용한 변압기의 이상진단 알고리즘 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;You, Y.P.;Sun, J.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1903-1905
    • /
    • 2000
  • Power transformers have a tendency of ultra-high voltage capacity as power demand increases day after day KEPCO also will have plan to supply transmission power from 345KV to 765KV in the early of 2000. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important in power transformers because of economic loss and its spreading effect. This study presents the algorithm for transformer oil analysis used KEPCO code, IEC code, gas pattern method and Dornenburg & Roger Ratio method. We also describe the MMI display of expert system programmed by Element Expert Tool(Neuron Data Inc.).

  • PDF

The study of insulation-characteristic in a mixture gas includes $SF_6$ ($SF_6$를 포함하는 혼합가스의 절연특성에 관한 연구)

  • 박명진;김대연;전병훈;하성철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.165-168
    • /
    • 1999
  • The electron transport coefficients in mixture gas includes SF/sub 6/ is analysed in range of E/N values from 60∼800(Td) by the Boltzmann method that using a set of electron collision crass sections determined by the researchers. Swarm parameters in the Boltzmann method simulation such as electron drift velocity, ionization and electron attachment coefficients is in nearly agreement with the respective experimental and theoretical for a range of E/N.

  • PDF

The Study of the insulation Charateristic in $SF_6$+$N_2$ mixture gas ($SF_6$+$N_2$ 혼합기체의 절연특성에 관한 연구)

  • 박명진;전병훈;하성철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.592-595
    • /
    • 2000
  • The electron transport coefficients in $SF_6$+$N_2$ gas is analyzed in range of E/P values from 70~240(V/cm $Torr^{-1}$) at 2$0^{\circ}C$ by Boltzmann method that using set of electron collision cross sections determined by authors. The result of this Boltzmann simulation such as ionisation coefficient, attachment coefficient, effective ionisation coefficient and breakdown voltage are in nearly agreement with the respective experimental and theoretical for a range of E/P.

  • PDF