154kV 전력계통 가스차단기 고장 분석 (Fault Analysis of a Gas Circuit Breaker in the 154kV Power Line)

  • 김영규;고영환;정이식;이상일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.342-344
    • /
    • 2008
  • This paper describes fault analysis of a $SF_6$ gas circuit breaker of a transformer in a hydro power plant which is connected to the 154kV line. The fault is a single-line-to-ground fault, so that it gives power generation halt and economical loss. The analysis has been done in aspects of the status of the breaker, insulation degradation, surge invasion and earthing resistance of the switchyard.

  • PDF

구동방법에 따른 세라믹 메탈 할라이드 램프의 전기적 및 방전특성 분석 (Electrical and Discharge Charcteristics Analysis of Ceramic Metal Halide Lamp with Operating Method)

  • 장혁진;양종경;김남군;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1623_1624
    • /
    • 2009
  • The use of arc tubes made of ceramic material further enhanced some of the metal halide lamp’s properties. These properties translate into higher efficacy with better color rendering, stable color through lamp long life. Recently, due to an increase in the application of the ceramic metal-halide lamp, the study for the property etc. according to Ballast's driving scheme and the study for arc tube material, optimization of gas and so on are being proceeded to improve the property of the lamp. Especially, to control ceramic metal-halide lamp, the vigorous study and practical use with respect to Electronic Ballast, which has been improved in the disadvantages of the conventional Magnetic Ballast are made. In this paper, Electrical characteristics and gas insulation destroy time are analyzed by comparing magnetic ballast with electronic ballast.

  • PDF

절연성능 향상을 위한 가스절연 개폐장치에서의 경사 기능성 재료 스페이서 및 전극 형상 연구 (A Study on Functionally Graded Material Spacer and Electrodes Shape in Gas Insulated Switchgear for the Improvement of Insulation Performance)

  • 주흥진;김봉석;고광철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1358_1359
    • /
    • 2009
  • 가스 절연 개폐장치(Gas Insulated Switchgear : GIS)의 고체 스페이서에 경사기능성 재료(Functionally Graded Material : FGM)를 적용할 때, 전계의 완화를 예상할 수 있다. 특히, 균일 유전율 분포를 가지는 스페이서에서 양극 근처에 집중된 높은 전계가 FGM 스페이서를 사용할 때, 스페이서와 $SF_6$ 가스의 접촉부로 옮겨지며, 그 크기가 완화됨을 확인할 수 있었다[1]. 본 연구에서는 상용 고체 스페이서의 양극 부근에서의 전계 집중을 감소시키기 위해 전극 형상의 최적화를 수행하였다. 최적화 기법으로는 완전계승계획법(Full Factorial Design : FFD)과 결합된 반응표면법(Response Surface Method : RSM)을 이용하였으며, 균일 유전율 스페이서에서 양극 형상을 최적화하였다. 또한 타원형 유전율 분포를 가지는 FGM 스페이서를 이용함으로써, 상용 GIS 모델에 비해 최대 전계가 크게 완화될 수 있음을 확인하였으며, 상용 GIS의 외함부의 크기를 줄여 실제 소형화 가능 여부를 확인하였다.

  • PDF

GIS에 있어서 전기적 절연진단법에 대한 연구[1] (A Study on the Electrical Diagnostic Methods In GIS)

  • 최재구;김영배;김익수;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.904-906
    • /
    • 1998
  • PD pulses have about one nanosecond rise time in the $SF_6$ gas insulation. These pulses propagate in the apparatus to PD sensors in the form of the voltage oscillation, high frequency current and the electromagnetic radiation. In this paper, we investigated the characteristics of two types of PD sensors, by putting high frequency signals in the form of sine waves and pulse into the test apparatus in air. Also, we measured PD quantity from the needle electrode and the sensitivity of the sensors. We found that PD of 70pC could be detected with this method and the study in $SF_6$ gas should be carried out for application to $SF_6$ GIS.

  • PDF

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

O.F. Cable에 연결된 154kV GIS의 뇌보호 (Lightning protection in an 154kV GIS connected by oil-filled cables)

  • 정태호
    • 전기의세계
    • /
    • 제29권5호
    • /
    • pp.315-320
    • /
    • 1980
  • It has been appeared and widely used today SF6 Gas Insulated Substation(Hereafter called GIS) for the power supply to the densely populated area due to the superior insulation withstand ability of SF6 Gas. And to maximize the compact effect of this substation, it is normal practice to connect underground cables. If it is possible to elieminate the redundant lightning arresters using the physical characterestics of travelling waves in underground cables, economical advantages can be obtained together with easy maintenances. It is presented in this paper the possiblity of eliminating the transformer protection lightning arresters under some conditions for the 154kV GIS's (BIL:750kV) which Korea Electric Co. plans to construct using the general purpose digital computer program.

  • PDF

부분방전시 방사전자파의 시간지연특성 (Time Delay Characteristics of Radiated Electromagnetic Wave with Partial Discharge)

  • 김해준;박광서;이현동;김기채;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1774-1776
    • /
    • 2001
  • The most of faults in gas insulation of power facilities are caused by partial discharge. Therefore we simulated partial discharge and measured the radiated electromagnetic wave emitted from partial discharge in the $SF_6$ gas by biconical antenna. This paper describes time delay characteristics of radiated electromagnetic waves with distance between antenna and discharge source.

  • PDF

가스절연 개폐장치에서 유전율 구배를 갖는 고체 절연물의 형상 최적화 (Shape Optimization of a Permittivity Graded Solid Insulator in a Gas Insulated Switchgear)

  • 주흥진;김동규;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제25권6호
    • /
    • pp.467-473
    • /
    • 2012
  • A functionally graded material (FGM) spacer, which the distribution of dielectric permittivity inside an insulator changes spatially, can considerably reduce the electric field concentration around a high-voltage electrode and along the gas-insulator interface when compared to a conventional spacer with a uniform permittivity distribution. In this research, we propose the FGM spacer with an elliptical permittivity distribution instead of that with a distribution of dielectric permittivity varying along a radial direction only in order to improve efficiently the insulation capability. The optimal design of the elliptical FGM spacer configuration is performed by using the response surface methodology (RSM) combined with the steepest descent method (SDM).

OF 케이블 절연유 가스분석을 통한 고장예방 (The prevention of Fault by Analyzing the Gas in Oil of Oil-Filled Cable System)

  • 김두진;김재승;윤종건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.444-445
    • /
    • 2008
  • This paper reviews the known techniques for diagnosing the condition of OF cable system and improving the service reliability. These tests are periodically achieved and intended to provide indications that the insulation system has deteriorated. One of these tests is analyzing the gas in oil on Oil-filled cable that is well known and widely accepted method. In this paper, this method of analysis and the relevant measurement standards overview and the concrete example of preventing fault incidence by performing this test is introduced.

  • PDF

The Lightning Current Parameters that Impact on the Surge Analysis of the EHV Gas Insulated Substation by EMTP

  • Shim Eung-Bo;Han Sang-Ok
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권1호
    • /
    • pp.1-7
    • /
    • 2005
  • This paper describes the lightning surge analysis model of extra high voltage GIS using EMTP. Various lightning current parameters were investigated in order to confirm the impact on the lightning surge analysis such as lightning current amplitude, waveform, size of GIS, tower footing resistance and surge arresters. The multi-story tower model and EMTP/TACS model were introduced for the simulation of dynamic arc characteristics. The margin between the maximum overvoltage and BIL of the GIS was about 10 percent and the margin between the maximum overvoltage and BIL of the transformer was 21 percent.