• Title/Summary/Keyword: gap measurement

Search Result 703, Processing Time 0.029 seconds

Optical and Electrical Properties of Al-doped ZnO Thin Films Fabricated by Sol-gel Method with Various Al Doping Concentrations and Annealing Temperatures (Sol-gel 법으로 제작한 Al-doped ZnO 박막의 도핑 농도 및 열처리 온도에 따른 광학적 및 전기적 특성)

  • Shin, Hyun-Ho;Kang, Seong-Jun;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.5
    • /
    • pp.1-7
    • /
    • 2007
  • AZO thin films have been fabricated on quartz substrate with various Al doping concentrations and annealing temperatures by sol-gel method. The bset condition of (002) orientation and smooth surface (rms = 1.082 nm) is obtained for the AZO thin film doped with 1 mol % Al and annealed at 550 $^{\circ}C$. The optical transmittance of AZO thin films is higher than 80 % in the visible region. We observe that the energy band gap extends with increasing the Al doping concentration. This phenomenon is due to the Burstein-Moss effect. Through the measurement of Hall effect, it is observed that the AZO thin film has larger carrier concentration and smaller electrical resistivity than the pure ZnO thin film. However, the AZO thin film shows the decrease of carrier concentration and the increase of resistivity with the increase of Al concentration, that is due to the segregation of Al at grain boundaries. The maximum carrier concentration of $1.80{\times}10^{19}\;cm^{-3}$ and the minimum resistivity of 0.84 ${\Omega}cm$ are obtained for the AZO thin film doped with 1 mol % Al and annealed at 550 $^{\circ}C$.

Reduction Gas and Chemical Additive Effects on the MOCVD Copper Films Deposited From (hfac)Cu(1,5-DMCOD) as a Precursor ((hfac)Cu(1,5-DMCOD) 전구체를 이용한 MOCVD Cu 증착 특성에 미치는 환원기체와 첨가제의 영향에 관한 연구)

  • Byeon, In-Jae;Seo, Beom-Seok;Yang, Hui-Jeong;Lee, Won-Hui;Lee, Jae-Gap
    • Korean Journal of Materials Research
    • /
    • v.11 no.1
    • /
    • pp.20-26
    • /
    • 2001
  • The deposition characteristics of MOCVO Cu using the (hfac)Cu(I) (1,5-DMCOD)(1,1,1,5,5,5-hexafluoro-2,4-pentanedionato Cu(I) 1,5-dimethyl-cyclooctadine) as a precursor have been investigated in terms of the effects of hydrogen and H(hfac) ligand addition with He carrier gas. MOCVD Cu using a Helium carrier gas showed a low deposition rate (20~$125{\AA}/min$) at the substrate temperature range of 180~$230^{\circ}C$. Moreover, the Cu film deposited at 19$0^{\circ}C$ was very thin (~$700{\AA}$) and showed the lowest resistivity value of $2.8{\mu}{\Omega}-cm$. The deposition rate of MOCVD Cu using $H_2$or H(hfac) addition was significantly enhanced especially at the low temperature region (180~$190^{\circ}C$). Furthermore, thinner Cu films (~$500{\AA}$) provided low resistivity (3.6~$2.86{\mu}{\Omega}-cm$). From surface reflectance measurement, very thin films deposited by using different gas system revealed good surface morphology comparable with sputtered Cu film ($300^{\circ}C$, vacuum-anneal). Hence, Cu film using (hfac)Cu(1,5-DMCOD) as a precursor is expected as a good seed layer in the electrochemical deposition process for Cu metallization.

  • PDF

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

The Growth of $MgO:LiNbO_3$ Single Crystal by Czochralski Method and its Density Measurement (Czochralski법에 의한 $MgO:LiNbO_3$단결정 성장과 밀도 측정)

  • Kim, Il-Won;Park, Bong-Chan;Kim, Gap-Jin
    • Korean Journal of Crystallography
    • /
    • v.4 no.2
    • /
    • pp.74-85
    • /
    • 1993
  • Single crystals of LiNbO3 have found extensive application in electro-optic and nonlinear optic devices. However, laser-induced refartive index inhomogeneities, which have been labeled opical damage impose limits on device optical damage in LiNbO3 is imporved if more than 4.5 rml% MgO is added to the melt The laser damage thrueshold increased as much as 100 times better then that of undoped crystals. The MgO doped cystal has thus been urterlsiv81y studied since then. In the study, Mgo:LiNbOs(MLA) single crystals dopsd with 0, 2.5, 5.0, 7.5, 10.0 mol% MgO have been grown by the czocrualski technique. The metls were prepared in the platinum crluible and 15∼20mm diameter crystals were grown with a length of 20∼30mm in a resitance heater. The growth rate was 2.5mm/hr, the rotation speed 15rpn. Before sawing MLN single crystals were annealed for 24 hours under atmosphere at a temperature of 1080℃. After sawing, we have found an annual ring cross section of MNA crystals only in the direction of perpendicilar to the c-axis. Nonuniform dispusion of MgO was pointed out that the cuties of the state of oxide were strongly affected by oxygen partial pressure in.

  • PDF

Solar Detoxification of Trichloroethylene in Waste Water with Slurry Batchtype Photoreactor (Slurry batch형 광화학 반응기를 이용한 폐수 내의 Trichlroethylene의 분해)

  • Lee, Tai-K.;Kim, Dong-H.;Cho, Sug-H.;Auh, Chung-Moo
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.10-20
    • /
    • 1992
  • In this experiment, photochemical reaction has been applied to destroy TCE in water phase. The main target of this work is to investigate the technical feasibility of large scale of solar detoxification reactor for water treatment. The results have revealed that solar detoxification utilizing photon energy from the sun is the most attractive process to decompose organic toxins in water phase at room temperature. The detailed results from this work are as follows; (1) The highest conversion ratio of TCE was obtained by using $TiO_2$, annatase as a photocatalyst among $TiO_2$ anatase, $TiO_2$ rutile and $V_2O_5$ under the same experimental condition. The anatase crystal structure was confirmed with XRD analysis, and its surface area was 7.748 $m^2/g$ from the BET-$N_2$ measurement (2) 0.1 wt% of $TiO_2$ anatase has been adopted as optimal quantity for batch slurry reactor at this experimental conditions. (3) The effect of hydrogen peroxide on the conversion of TCE was investigated. Its optimal quantity was 0.06 vol. % under this experimental conditions. (4) The effect of oxygen on the conversion of TCE also was studied by controlling the head space in photoreactor. Results indicated that sufficient amount of oxygen should be supplied to accomplish the highest conversion rate of TCE in water phase.

  • PDF

Effect of Al Precursor Addition Time on Catalytic Characteristic of Cu/ZnO/Al2O3 Catalyst for Water Gas Shift Reaction (Water Gas Shift 반응을 위한 Cu/ZnO/Al2O3 촉매에서 Al 전구체 투입시간에 따른 촉매 특성 연구)

  • BAEK, JEONG HUN;JEONG, JEONG MIN;PARK, JI HYE;YI, KWANG BOK;RHEE, YOUNG WOO
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.5
    • /
    • pp.423-430
    • /
    • 2015
  • $Cu/ZnO/Al_2O_3$ catalysts for water gas shift (WGS) reaction were synthesized by co-precipitation method with the fixed molar ratio of Cu/Zn/Al precursors as 45/45/10. Copper and zinc precursor were added into sodium carbonate solution for precipitation and aged for 24h. During the aging period, aluminum precursor was added into the aging solution with different time gap from the precipitation starting point: 6h, 12h, and 18h. The resulting catalysts were characterized with SEM, XRD, BET surface measurement, $N_2O$ chemisorption, TPR, and $NH_3$-TPD analysis. The catalytic activity tests were carried out at a GHSV of $27,986h^{-1}$ and a temperature range of 200 to $400^{\circ}C$. The catalyst morphology and crystalline structures were not affected by aluminum precursor addition time. The Cu dispersion degree, surface area, and pore diameter depended on the aging time of Cu-Zn precipitate without the presence of $Al_2O_3$ precursor. Also, the interaction between the active substance and $Al_2O_3$ became more stronger as aging duration, with Al precursor presented in the solution, increased. Therefore, it was confirmed that aluminum precursor addition time affected the catalytic characteristics and their catalytic activities.

Degradation of Sulfonamide Antibiotic Substances by Ozonation: An Experimental and Computational Approach (설폰아미드계 항생물질의 오존산화분해에 대한 계산화학적 해석 및 실험적 검증)

  • Won, Jung Sik;Lim, Dong Hee;Seo, Gyu Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.442-450
    • /
    • 2014
  • Concern has grown over a presence of micropollutants in natural water since sulfonamide antibiotic substances such as sulfamethazine, sulfamethoxazole, sulfathiazole have been frequently detected in Nakdong River, Korea. The current work investigates the degradation of the three sulfonamide substances by using quantum chemistry calculations of density functional theory (DFT) and experimental measurement techniques of Fourier transform infrared spectroscopy (FT-IR) and ultraviolet-visible spectrophotometer (UV-VIS). DFT calculations demonstrate that the lowest energy gap between the highest occupied molecular orbital (HOMO) and the lowest unoccupied molecular orbitals (LUMO) lies in sulfanilamide functional group of sulfonamide, implying that the sulfanilamide functional group would be the most active site for ozone oxidation. Also, UV-VIS spectra and FT-IR analysis reveal that 260 nm band originated from sulfanilamide group was absent after ozone oxidation, indicating that a functional group of amine (N-H) was removed from sulfanilamide. Both theoretical and experimental observations agree well with each other, demonstrating the DFT calculation tool can be an alternative tool for the prediction of chemical reactions in purification treatment processes.

Effects of RF power on the Electrical and Optical Properties of GZO Thin Films Deposited on Flexible Substrate (RF 파워가 플렉시블 기판에 성장시킨 GZO 박막의 전기적 및 광학적 특성에 미치는 영향)

  • Joung, Yang-Hee;Kang, Seong-Jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2497-2502
    • /
    • 2014
  • The 5 wt.% Ga-doped zinc oxide (GZO) thin films were fabricated on PES substrates with various RF power 50~80 W by using RF magnetron sputtering in order to investigate the optical and electrical properties of GZO thin films. The XRD measurement showed that GZO thin films exhibit c-axis orientation. At a RF power of 70W, the GZO thin film showed the highest (002) diffraction peak with a Full-Width-Half-Maximum (FWHM) of $0.44^{\circ}$. AFM analysis showed that the lowest surface roughness (0.20 nm) was obtained for the GZO thin film fabricated at 70 W of RF power. The electrical property indicated that the minimum resistivity ($6.93{\times}10^{-4}{\Omega}{\cdot}cm$) and maximum carrier concentration ($7.04{\times}10^{20}cm^{-3}$) and hall mobility ($12.70cm^2/Vs$) were obtained in the GZO thin film fabricated at 70W of RF power. The optical transmittance in the visible region was higher than 80 %, regardless of RF power. The optical band-gap showed the slight blue-shift with increased in carrier concentration which can be explained by the Burstein-Moss effect.

Effects of Pd Addition Amount and Method on the Characteristics of SnO2 Semiconductor Thick Films for Alcohol Gas Sensors (Pd 첨가량 및 첨가방법이 알코올 센서용 SnO2 반도체 후막 특성에 미치는 영향 연구)

  • Kim, Jun-Hyung;Kim, Hyeong-Gwan;Lee, Ho-Nyun;Kim, Hyun-Jong;Lee, Hee-Chul
    • Journal of Surface Science and Engineering
    • /
    • v.50 no.5
    • /
    • pp.411-420
    • /
    • 2017
  • In this paper, two methods of making the Pd-added $SnO_2$ ($Pd-SnO_2$) powder with pure tetragonal phase by the hydrazine method were suggested and compared in terms of crystal structure, surface morphology, and alcohol gas response. One of the addition methods is to use $PdCl_2$ as a Pd source, the other is to use Pd-based organic with oleylamine (OAM). When Pd concentration was increased from 0 to 5 wt%, the average grain size of $Pd-SnO_2$ made with Pd-OAM were decreased from 32 to 12 nm. In the case of using with $PdCl_2$, grain size of the $PdCl_2$ fell to less than 10 nm. However, agglomerated and extruded surface morphology was observed for the films with Pd addition over 4 wt%. The crack-free $Pd-SnO_2$ thick films were able to successfully fill the $30{\mu}m$ gap of patterned Pt electrodes by optimized ink dropping method. Also, the 2 wt% $Pd-SnO_2$ thick film made with PdCl2 showed gas responses ($R_{air}/R_{gas}$) of 3.7, 5.7 and 9.0 at alcohol concentrations of 10, 50 and 100 ppm, respectively. On the other hand, the prepared 3 wt% $Pd-SnO_2$ thick film with Pd-OAM exhibited very excellent responses of 3.4, 6.8 and 12.2 at the equivalent measurement conditions, respectively. The 3 wt% $Pd-SnO_2$ thick film with Pd-OAM has a specific surface area of $31.39m^2/g$.

Properties of liquid crystal alignment layers exposued to ion-beam irradiation enemies (이온빔 에너지에 따른 액정배향막의 전기광학적 특성연구)

  • Oh, Byeong-Yun;Lee, Kang-Min;Park, Hong-Gyu;Kim, Byoung-Yong;Kang, Dong-Hun;Han, Jin-Woo;Kim, Young-Hwan;Han, Jeong-Min;Lee, Sang-Keuk;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.430-430
    • /
    • 2007
  • In general, polyimides (PIs) are used in liquid crystal displays (LCDs) as alignment layer of liquid crystals (LCs). Up to date, the rubbing alignment technique has been widely used to align liquid crystals on the PI surface, which is suitable for mass-production of LCDs because of its simple process and high productivity. However, this method has some disadvantages. Rubbed PI surfaces include the debris left by the cloth and the generation of electrostatic charges during rubbing process. Therefore, rubbing-free techniques for LC alignment are strongly required in LCD technology. In this experiment, PI was uniformly coated on indium-tin-oxide electrode substrates to form LC alignment layers using a spin-coating method and the PI layers were subsequently imidized at 433 K for 1 h. The thickness of the PI layer was set at 50 nm. The LC alignment layer surfaces were exposed to an $Ar^+$ ion-beam under various ion-beam energies. The antiparallel cells and twisted-nematic (TN) cells for the measurement of pretile angle and electro-optical characteristics were fabricated with the cell gap of 60 and $5\;{\mu}m$, respectively. The LC cells were filled with nematic LC (NLC, MJ001929, Merck) and were assembled. The NLC alignment capability on ion-beam-treated PI was observed using photomicroscope and the pretilt angle of the NLC was measured by the crystal-rotation method at room temperature. Voltage-transmittance (V-T) and response time characteristics of the ion-beam irradiated TN cell were measured by a LCD evaluation system.

  • PDF