• Title/Summary/Keyword: gap measurement

Search Result 701, Processing Time 0.026 seconds

An Operations Study on a Home Health Nursing Demonstration Program for the Patients Discharged with Chronic Residual Health Care Problems (추후관리가 필요한 만성질환 퇴원환자 가정간호 시범사업 운영 연구)

  • 홍여신;이은옥;이소우;김매자;홍경자;서문자;이영자;박정호;송미순
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.2
    • /
    • pp.227-248
    • /
    • 1990
  • The study was conceived in relation to a concern over the growing gap between the needs of chronic patients and the availability of care from the current health care system in Korea. Patients with agonizing chronic pain, discomfort, despair and disability are left with helplessly unprepared families with little help from the acute care oriented health care system after discharge from hospital. There is a great need for the development of an alternative means of quality care that is economically feasible and culturally adaptible to our society. Thus, the study was designed to demonstrate the effectiveness of home heath care as an alternative to bridge the existing gap between the patients' needs and the current practice of health care. The study specifically purports to test the effects of home care on health expenditure, readmission, job retention, compliance to health care regime, general conditions, complications, and self-care knowledge and practices. The study was guided by the operations research method advocated by the Primary Health Care Operations Research Institute(PRICOR) which constitutes 3 stages of research : namely, problem analysis solution development, and solution validation. The first step in the operations research was field preparation to develop the necessary consensus and cooperation. This was done through the formation of a consulting body at the hospital and a steering committee among the researchers. For the stage of problem analysis, the Annual Report of Seoul National University Hospital and the patients records for last 5 years were reviewed and selective patient interviews were conducted to find out the magnitude of chronic health problems and areas of unmect health care needs to finally decide on the kinds of health problems to study. On the basis of problem analysis, the solution development stage was devoted to home care program development asa solution alternative. Assessment tools, teaching guidelines and care protocols were developed and tested for their validity. The final stage was the stage of experimentation and evaluation. Patients with liver diseases, hemiplegic and diabetic conditions were selected as study samples. Discharge evaluation, follow up home care, measurement and evaluation were carried out according to the protocols of care and measurement plan for each patient for the period of 6 months after discharge. The study was carried out for the period from Jan. 1987 to Dec. 1989. The following are the results of the study presented according to the hypotheses set forth for the study ; 1. Total expenditures for the period of study were not reduced for the experimental group, however, since the cost per hospital visit is about 4 times as great as the cost per home visit, the effect of cost saving by home care will become a reality as home care replaces part of the hospital visits. 2. The effect on the rate of readmission and job retention was found to be statistically nonsignificant though the number of readmission was less among the experimental group receiving home care. 3. The effect on compliance to the health care regime was found to be statistically significant at the 5% level for hepatopathic and diabetic patients. 4. Education on diet, rest and excise, and medication through home care had an effect on improved liver function test scores, prevention of complications and self - care knowledge in hepatopathic patients at a statistically significant level. 5. In hemiplegic patient, home care had an effect on increased grasping power at a significant level. However. there was no significant difference between the experimental and control groups in the level of compliane, prevention of complications or in self-care practices. 6. In diabetic patients, there was no difference between the experimental and control groups in scores of laboratory tests, appearance of complications, and self-care knowledge or self -care practices. The above findings indicate that a home care program instituted for such short term as 6 months period could not totally demonstrate its effectiveness at a statistically significant level by quantitative analysis however, what was shown in part in this analysis, and in the continuous consultation sought by those who had been in the experimental group, is that home health care has a great potential in retarding or preventing pathological progress, facilitating rehabilitative and productive life, and improving quality of life by adding comfort, confidence and strength to patients and their families. For the further studies of this kind with chronic patients it is recommended that a sample of newly diagnosed patients be followed up for a longer period of time with more frequent observations to demonstrate a more dear- cut picture of the effectiveness of home care.

  • PDF

Effect of Visual Perception by Vision Therapy for Improvement of Visual Function (시각기능 개선을 위한 시기능훈련이 시지각에 미치는 영향)

  • Lee, Seung Wook;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.491-499
    • /
    • 2015
  • Purpose: This study was to examine how decline of visual function affects visual perception by assessing visual perception after improving visual function through visual training, and observing the change in the cognitive ability of visual perception. Methods: This study analyzes the visual perceptual evaluation (TVPS_R) of 23 children below age 13($8.75{\pm}1.66$) who have visual abnormalities, and improves visual function after conducting vision training (vision therapy) of the children. Results: Convergence increased from average $3.39{\pm}2.52{\Delta}$ (prism) to $13.87{\pm}6.04{\Delta}$ in the measurement of long-distance disparate points, and from average $5.48{\pm}3.42{\Delta}$ to $18.43{\pm}7.58{\Delta}$ in the measurement of short-distance disparate points. Short-distance diplopia points increased from $25.87{\pm}7.33cm$ to $7.48{\pm}2.87cm$, and as for accommodative insufficiency, short-distance blur points increased from $19.57{\pm}7.16cm$ to $7.09{\pm}1.88cm$. In the visual perceptual evaluation performed before and after improving visual function, 6 items except visual memory showed statistically significant improvement. By order of significant improvement, response gap was highest with $17.74{\pm}16.94$(p=0.000) in visual closure, followed by $15.65{\pm}17.11$(p=0.000) in visual sequential-memory, $13.65{\pm}16.63$(p=0.001) in visual figure-ground, $12.74{\pm}18.41$(p=0.003) in visual form-constancy, $6.48{\pm}10.07$ (p=0.005) in visual discrimination, and $4.17{\pm}9.33$(p=0.043) in visual spatial-relationship. In the visual perception quotient that added up these scores, the response gap was $15.22{\pm}8.66$(p=0.000), showing a more significant result. Conclusions: Vision training enables efficient visual processing and improves visual perceptual ability. It was confirmed that improvement of visual function through visual training not only improves abnormal visual function but also affects visual perception of children such as learning, perception and recognition.

Measurement of Verticality and Joint Gaps of a Near-surface Disposal Facility Vault Through a Mock-up Test for Fill-up Stages (표층처분시설 처분고의 목업테스트를 통한 채움단계별 수직도 및 이음부 벌어짐 측정)

  • Choi, Dong-Ho;Ann, Ki-Yong;Choi, In-Yong;Lee, Hyuk-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.537-544
    • /
    • 2021
  • In order to describe the fill-up stages of a near-surface disposal facility vault, a mock-up test is performed, and its behavior during the fil l -up stages is investigated. On an in-site concrete foundation with a l ength of 6600mm, a width of 6600mm and a thickness of 400mm, a reinforced concrete disposal vaul t is manufactured with 4 precast (PC) corner wal l s and 8 PC side wal l s. 36 wasted drums are pl aced on the 1st fl oor in 6 by 6, and then the empty space is fil l ed with grout fil l er. These processes are repeated up to the 5th floor, and the verticality and the joint gaps are measured for each fill-up stage. The verticality is measured using a level at 6 positions on each side wall (3 positions on the left and right sides, respectivel y), i.e. a total of 24 positions on the 4 side wal l s. The joint gaps are measured at 9 positions on each side wal l (3 positions on the left, center and right sides, respectively), I.e. a total 36 positions on the 4 side walls. To measure the joint gaps, crack tips are installed on the left and right sides of every joint gap, and vernier calipers are used. The measured verticality obtained through the mock-up test was found to be ±0.1° based on the initial stage (ST0), and the result of the joint gap was up to 0.38mm. This appears to have a negligible effect on the structure.

Exploring A Research Trend on Entrepreneurial Ecosystem in the 40 Years of the Asia Pacific Journal of Small Business for the Development of Ecosystem Measurement Framework (「중소기업연구」 40년 동안의 창업생태계 연구 동향 고찰 및 측정모형 개발을 위한 탐색적 연구)

  • Seo, Ribin;Choi, Kyung Cheol;Byun, Youngjo
    • Korean small business review
    • /
    • v.42 no.4
    • /
    • pp.69-102
    • /
    • 2020
  • Shedding new light on the research trend on entrepreneurial ecosystems in the 40-year history of the Asia Pacific Journal of Small Business, this study aims at exploring a potential measurement framework of ecological inputs and outputs in an entrepreneurial ecosystem that promotes entrepreneurship at geographical and spatial levels. As a result of the analysis of research on the entrepreneurial ecosystem in the journal, we found that prior studies emphasized the managerial importance of various ecological factors on the premise of possible causalities between the factors and entrepreneurship. However, empirical research to verify the premised causality has been underexplored yet. This literature gap may lead to unbalanced development of conceptual and case studies that identify requirements for successful entrepreneurial ecosystems based on experiential facts, thereby hindering the generalization of the research results for practical implications. In that there is a growing interest in creating and operating productive entrepreneurial ecosystems as an innovation engine that drives national and regional economic growth, it is necessary to explore and develop the measurement framework for ecological factors that can be used in future empirical research. Hereupon, we apply a conceptual model of 'input-output-outcome-impact' to categorize individual environmental factors identified in prior studies. Based on the model. We operationalize ecological input factors as the financial, intellectual, institutional, and social capitals, and ecological output factors as the establishment-based, innovation-based, and performance-based entrepreneurship. Also, we propose several longitudinal databases that future empirical research can use in analyzing the potential causality between the ecological input and output factors. The proposed framework of entrepreneurial ecosystems, which focuses on measuring ecological input and output factors, has a high application value for future research that analyzes the causality.

Study on Glomerular Filtration Rate comparison according to renal depth measurement of kidney donors (신 공여자에서 신장 깊이 측정에 따른 사구체여과율의 비교에 관한 고찰)

  • Lee, Han Wool;Park, Min Soo;Kang, Chun Goo;Cho, Seok Won;Kim, Joo Yeon;Kwon, O Jun;Lim, Han Sang;Kim, Jae Sam;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.48-56
    • /
    • 2014
  • Purpose $^{99m}Tc$-DTPA renal scintigraphy serves as a key indicator to measure a kidney donor's Glomerular Filtration Rate (GFR) and determine the possibility of kidney transplant. The Gates method utilized to measure GFR considers 3 variables of renal depth, injection dose, and net kidney counts. In this research, we seek to compare changes in kidney donors' GFR according to renal depth measurement methods of the 3 variables. Materials and Methods We investigated 32 kidney donors who had visited the hospital from October, 2013 to March, 2014 and received abdominal CT and $^{99m}Tc$-DTPA GFR examination. With the cross-section image of the CT and the lateral image from a gamma camera, we measured the renal depth and compared with renal depth calculation equations-Tonnesen, Taylor, and Itoh methods. Renal depth-specific GFR was calculated by using Xeleris Ver. 2.1220 of GE. Then the results were compared with MDRD (Modification of Diet Renal Disease) GFRs based on serum creatinine level. Results The renal depths measured based on the CT and gamma camera images showed high correlation. Tonessen equation gave the lowest GFR value while the value calculated by using the renal depth of CT image was the highest with a 16.62% gap. MDRD GFR showed no statistically significant difference among values calculated through Taylor, Itoh, CT and gamma camera renal depth application (P>0.05), but exhibited a statistically significant change in the value based on Tonnesen equation (P<0.05). Conclusion This research has found that, in GFR evaluation in kidney donors by utilizing $^{99m}Tc$-DTPA, Tonnesen equation-based Gates method underestimated the value than the MDRD GFR. Therefore, if a MDRD GFR value shows a huge difference from the actual examination value, using an image-based renal depth measurement, instead of Tonnesen equation applied to Gates method, is expected to give an accurate GFR value to kidney donors.

  • PDF

The change of validity of blood zinc protoporphyrin test by different cut-off level in lead workers (연취급 근로자들의 혈중 ZPP 농도 선별기준에 따른 정확도의 변화)

  • Kim, Yong-Bae;Ahn, Hyun-Cheol;HwangBo, Young;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.741-751
    • /
    • 1997
  • Measurement of blood lead (PbB) and blood zinc protoporphyrin (ZPP) are most common biological indices to identify the individual at risk for excess or the health sequences by lead exposure. Because PbB is known most important and reliable index of lead exposure, PbB is often regarded as a gold standard to detect lead exposure. But in Korea PbB is a secondary test item of detailed health check-up with positive finding of screening test in most occasion. Our lead standard requires all lead workers to take annual heath-check twice a year for investigation of their health effect due to lead exposure. Blood ZPP is one of most important index to detect high lead absorption in lead workers as a screening test. Measurement of blood ZPP is known ,well to correlate with PbB in steady state of exposure in most lead workers and is often used as a primary screening test to detect high lead absorption of lead workers with the advantage of simplicity, easiness, portability and low cost. The current cut-off criteria of blood ZPP for further detailed health check-up is $100{\mu}g/d\ell$ which is supposed to match the level of $40{\mu}g/d\ell$ of PbB according to our standard. Authors tried to investigate the validity of current criteria of cut-off level $(100{\mu}g/d\ell)$ of blood ZPP and possible another better cut-off level of it to detect the lead workers whose PbB level over $40{\mu}g/d\ell$. The subjects in our study were 212 male workers in three small scale storage battery industries. Blood ZPP, PbB and hemoglobin (Hb) were selected as the indices of lead exposure. The results were as follows. 1. The mean of blood ZPP, PbB and Hb in lead workers were $79.5{\pm}46.7{\mu}g/d\ell,\;38.7{\pm}15.1{\mu}g/d\ell,\;and\;14.8{\pm}1.2g/d\ell$, respectively. There were significant differences in blood ZPP, PbB and Hb by industry (P<0.01). 2. The percents of lead workers whose blood ZPP were above $100{\mu}g/d\ell$ in the group of work duration below 1, 1-4, 5-9 and above 10 years were 8.6%, 17.2%, 47.6%, and 50.0%, respectively. The percents of lead workers whose PbB were above $40{\mu}g/d\ell$ in those were 31.4%, 40.4%, 71.4%, and 86.4%, respectively. 3. The percents of lead workers whose PbB were below $40{\mu}g/d\ell$, $40-59{\mu}g/d\ell$ and above $60{\mu}g/d\ell$ were 54.7%, 34.9% and 10.4%, respectively. Those of lead workers whose blood ZPP were below $100{\mu}g/d\ell$, $100-149{\mu}g/d\ell$ and above $150{\mu}g/d\ell$ were 79.2%, 13.7% and 7.1%, respectively. 4. Simple linear regression of PbB on blood ZPP was statistically significant (P<0.01) and as PbB was $40{\mu}g/d\ell$, blood ZPP was $82.1{\mu}g/d\ell$. 5. While the highest sensitivity and specificity of blood ZPP test to detect lead workers with PbB eve. $40{\mu}g/d\ell$ were observed in the cut-off level of $50{\mu}g/d\ell$ and $100{\mu}g/d\ell$ of blood ZPP, respectively, the highest validity (sensitivity+specificity) of blood ZPP to detect lead workers with PbB over $40{\mu}g/d\ell$ was observed in the cut-off level of around $70{\mu}g/d\ell$ of blood ZPP. But even with optimal cut-off level of around $70{\mu}g/d\ell$ of blood ZPP, still 25.0% of false negative and 20.7% false positive lead workers were found. As the result of this study, it was suggested that reconsideration of current blood ZPP cut-off of our lead standard from $100{\mu}g/d\ell$ to somewhat lower level such as around $70{\mu}g/d\ell$ and the inclusion of PbB measurement as a primary screening test for lead workers was highly recommended for the effective prevention of lead workers.

  • PDF

Error Analysis of Image Velocimetry According to the Variation of the Interrogation Area (상관영역 크기 변화에 따른 영상유속계의 오차 분석)

  • Kim, Seojun;Yu, Kwonkyu;Yoon, Byungman
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.8
    • /
    • pp.821-831
    • /
    • 2013
  • Recently image velocimetries, including particle image velocimetry (PIV) and surface image velocimetry (SIV), are often used to measure flow velocities in laboratories and rivers. The most difficult point in using image velocimetries may be how to determine the sizes of the interrogation areas and the measurement uncertainties. Especially, it is a little hard for unskilled users to use these instruments, since any standardized measuring techniques or measurement uncertainties are not well evaluated. Sometimes the user's skill and understanding on the instruments may make a wide gap between velocity measurement results. The present study aims to evaluate image velocimetry's uncertainties due to the changes in the sizes of interrogation areas and searching areas with the error analyses. For the purpose, we generated 12 series of artificial images with known velocity fields and various numbers and sizes of particles. The analysis results showed that the accuracy of velocity measurements of the image velocimetry was significantly affected by the change of the size of interrogation area. Generally speaking, the error was reduced as the size of interrogation areas became small. For the same sizes of interrogation areas, the larger particle sizes and the larger number of particles resulted smaller errors. Especially, the errors of the image velocimetries were more affected by the number of particles rather than the sizes of them. As the sizes of interrogation areas were increased, the differences between the maximum and the minimum errors seemed to be reduced. For the size of the interrogation area whose average errors were less than 5%, the differences between the maximum and the minimum errors seemed a little large. For the case, in other words, the uncertainty of the velocity measurements of the image velocimetry was large. In the viewpoint of the particle density, the size of the interrogation area was small for large particle density cases. For the cases of large number of particle and small particle density, however, the minimum size of interrogation area became smaller.

Adaptability of zirconia core fabricated by cold isostatic pressing (냉간 정수압 성형법으로 제작된 지르코니아 코어의 적합도에 관한 연구)

  • Seo, Yoon-Jeong;Yun, Kwi-Dug;Kim, Hyun-Seung;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.143-150
    • /
    • 2010
  • Purpose: The purpose of this study is to fabricate the new zirconia block (CNU block) and to evaluate fit of core and porcelain veneered zirconia crown. Material and methods: The experimental blocks were fabricated from the commercial ytrria-stabilized zirconia powder (KZ-3YE Type A). The powder was uniaxial pressing and the green bodies were conducted using the Cold Isostatic Pressing. The zirconia blocks were presintered at $1040^{\circ}C$ and the final sintering was performed at $1450^{\circ}C$. The Kavo Everest ZS $blank{(R)}$ (KaVo, Biberach/ $Ri{\beta}$.) was used as a control group. The linear shrinkage of CNU block and Kavo block were compared. Twenty-one cores for porcelain veneered crowns were fabricated with CAD/CAM system ($Everest{(R)}$, Biberach/ $Ri{\beta}$.). Group I; seven cores fabricated from Kavo blocks, Group II; seven cores fabricated from CNU blocks, Group III; seven cores from CNU blocks and porcelain veneering for crowns. All specimens were cemented and sectioned into two planes; diagonal and bucco-lingual. The measurement of the marginal, internal, and occlusal fit was carried out using SEM ($S-4800^{(R)}$) at $30{\times}$. The results were analyzed by one-way ANOVA test. Results: The linear shrinkage of the CNU block and the KaVo block was 19.00% and 20.09%. The marginal gap of cores ($29.67{\pm}6.58{\mu}m$) fabricated from CNU blocks showed significantly smaller than that of the cores of Kavo blocks ($36.84{\pm}7.18{\mu}m$) (P < .05). The internal gaps of the porcelain veneered crowns ($32.23{\pm}6.33{\mu}m$) were larger than those of the other two groups ($37.57{\pm}6.81{\mu}m$ and $38.14{\pm}6.81{\mu}m$). Conclusion: No statistically significant difference was found in between experimental groups and control group. The experimental groups in marginal gap showed significantly smaller than the control group.

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM (CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구)

  • Seo-Rahng Kim;Myung-Joo Kim;Ji-Man Park;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Purpose. The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods. Materials and methods. Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150. Results. Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 ㎛ for deep chamfer margin and 6.3 ± 3.5 ㎛ for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 ㎛ for deep chamfer margin and 33 ± 20.5 ㎛ for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion. Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.