• Title/Summary/Keyword: gap measurement

Search Result 701, Processing Time 0.03 seconds

Comparison the fit of three-unit metal framework fabricated by wax milling method and digital light projection method (왁스 밀링 방법 및 디지털 광 프로젝션 방법으로 제작된 3본 금속 구조물의 적합도 비교)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.9-19
    • /
    • 2019
  • Purpose: This study was conducted to comparative evaluate the marginal and internal gap of three-unit metal frameworks(Co-Cr) fabricated by wax milling method and digital light projection method of CAD/CAM systems. Methods: All the specimens were fabricated by three different fabrication methods: conventional wax up with casting(CWC), milled wax block with casting(MWC), digital light projection with casting(DLPC) (n=10 each). The marginal and internal fits of specimens were examined using a replica technique. The light-body silicone thickness was measured at 8 reference points(each abutment: 16 measurements). All measurements were conducted by a stereomicroscope. Digital photo were taken at $150{\times}$ magnification and then analyzed using a measurement software. The Mann-Whitney test was used for analyzing the results. Results: Statistically significant differences were found between the fabrication methods(p<0.001). The mean(SD) is ${\mu}m$ for fabrication methods, the mean marginal fit were recorded respectively, CWC 63(38), MWC group 50(33), DLPC 103(54) and the mean internal fit CWC 96(47), MWC group 116(41), DLPC 138(66). Conclusion : The marginal and internal fit were statistically different according to the fabrication methods(p<0.001). In all fabrication methods, the greatest misfit was found the occlusal area of all specimens.

Evaluation of Survey Data Quality Based on Interviewers' Assessments: An Example from Taiwan's Election and Democratization Study

  • Tsai, Chi-lin;Liu, Tsung-Wei;Chen, Yi-ju
    • Asian Journal for Public Opinion Research
    • /
    • v.7 no.1
    • /
    • pp.57-74
    • /
    • 2019
  • Researchers usually examine the quality of survey data by several conventional measures of reliability and validity. However, those measures are mainly designed to examine the quality of an individual measurement, rather than the quality of a data set as a whole. There is a relative lack of methods for evaluation of the overall data quality. This paper attempts to fill this gap. We propose using interviewers' assessments as one of criteria for evaluating the overall data quality. Interviewers are the ones who literally conduct and thus directly observe interviews. Taiwan's Election and Democratization Studies (TEDS) have required interviewers to assess how trustworthy the responses of each of their interviewees are, and to provide several descriptions about the process and environment of the interviews. We use this information to evaluate the data quality of TEDS surveys and compare it with the results from the conventional test-retest method. The findings are that the interviewer assessment is a fair indicator of the overall reliability of attitudinal questions but not a good indicator when factual questions are examined. Regarding the evaluation of data validity, more data is required to see whether or not interviewers' assessment is informative in terms of data quality.

A Probabilistic Analysis for Periodicity of Real-time Tasks

  • Delgado, Raimarius;Choi, Byoung Wook
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.134-142
    • /
    • 2021
  • This paper proposes a probabilistic method in analyzing timing measurements to determine the periodicity of real-time tasks. The proposed method fills a gap in existing techniques, which either concentrate on the estimation of worst-case execution times, or do not consider the stochastic behavior of the real-time scheduler. Our method is based on the Z-test statistical analysis which calculates the probability of the measured period to fall within a user-defined standard deviation limit. The distribution of the measured period should satisfy two conditions: its center (statistical mean) should be equal to the scheduled period of the real-time task, and that it should be symmetrical with most of the samples focused on the center. To ensure that these requirements are met, a data adjustment process, which omits any outliers in the expense of accuracy, is presented. Then, the Z-score of the distribution according to the user-defined deviation limit provides a probability which determines the periodicity of the real-time task. Experiments are conducted to analyze the timing measurements of real-time tasks based on real-time Linux extensions of Xenomai and RT-Preempt. The results indicate that the proposed method is able to provide easier interpretation of the periodicity of real-time tasks which are valuable especially in comparing the performance of various real-time systems.

Fabrication and Evaluation of Thin Film Filter Type 4-Channel Wavelength Division Multiplexing Device (박막필터형 4- 채널 파장분할 다중화 소자의 제작 및 평가)

  • Park, Kyung Hyun;Seo, Wan Seok;Chung, Young Man;Park, Hee Gap;Ma, Dong Sung;Kang, Min Ho
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.3
    • /
    • pp.400-407
    • /
    • 1987
  • Thin film filter type 4-channel wavelength division multiplexing(WDM) device was designed and fabricated for the application in optical subscriber loop system. It has multi-mode fiber pigtails and four wavelength division consisting of 0.81, 0.89, 1.2 and 1.3 um. The evaluated performances are 1-2d B of insertion loss(connector loss excluded)and 30-35d B of crosstalk attenuation for all channels. The performance of the fabricated device was tested in the wideband optical transmission experiment, where the SNR degradation due to the crosstalk of the device was found to be within a measurement error.

  • PDF

Updating BIM: Reflecting Thermographic Sensing in BIM-based Building Energy Analysis

  • Ham, Youngjib;Golparvar-Fard, Mani
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.532-536
    • /
    • 2015
  • This paper presents an automated computer vision-based system to update BIM data by leveraging multi-modal visual data collected from existing buildings under inspection. Currently, visual inspections are conducted for building envelopes or mechanical systems, and auditors analyze energy-related contextual information to examine if their performance is maintained as expected by the design. By translating 3D surface thermal profiles into energy performance metrics such as actual R-values at point-level and by mapping such properties to the associated BIM elements using XML Document Object Model (DOM), the proposed method shortens the energy performance modeling gap between the architectural information in the as-designed BIM and the as-is building condition, which improve the reliability of building energy analysis. The experimental results on existing buildings show that (1) the point-level thermography-based thermal resistance measurement can be automatically matched with the associated BIM elements; and (2) their corresponding thermal properties are automatically updated in gbXML schema. This paper provides practitioners with insight to uncover the fundamentals of how multi-modal visual data can be used to improve the accuracy of building energy modeling for retrofit analysis. Open research challenges and lessons learned from real-world case studies are discussed in detail.

  • PDF

Measuring Hotel Service Quality Using Social Media Analytics: The Moderating Effects of Brand of Origin

  • Byounggu Choi;Shin-Hyeok Kang
    • Asia pacific journal of information systems
    • /
    • v.33 no.3
    • /
    • pp.677-701
    • /
    • 2023
  • With the rapid advancement of social media analytics and artificial intelligence, many studies have used online customer reviews as an important source to measure service quality in many industries, including the hotel industry. However, these studies have failed to identify the relative importance of different dimensions of service quality and their role in customer satisfaction. To fill this research gap, this study aims to identify the effects of service quality on hotel customer satisfaction from the multidimensional perspectives using sentiment analysis with self-training on online reviews. Additionally, the moderating role of the brand of origin for each service quality dimension is also investigated. Drawing on the SERVQUAL model and brand of origin concept, this study develops 12 hypotheses and empirically tests them using 30,070 online customer hotel reviews collected from TripAdvisor.com. The results indicated that overall service quality and each dimension of SERVQUAL significantly influenced customer satisfaction of hotels. The results also confirmed the moderating effects of brand of origin on overall service quality. However, the moderating effects of brand of origin for the tangible, reliability, and empathy dimensions of service quality were significant, whereas the effects for responsiveness and assurance were not. This study sheds new light on service quality measurement by analyzing the multidimensional features of service quality and the role of brand of origin in the hotel service context.

An improved crystal rotation method for simultaneous measurement of pretilt angle and thickness of a liquid crystal layer (액정셀의 선경사각과 액정층의 두께를 함께 재는 개선된 결정회전법)

  • Son, Gong-Sook;Park, Chan;Park, Hee-Gap;Kim, Jin-Seung;Rho, Bong-Gyu;Lee, Hyong-Jong;Kim, Jae-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.213-218
    • /
    • 1996
  • An improved crystal rotation method with increased accuracy and range is proposed and experimentally verified for simultaneous measurement of molecular tilt angle and thickness of LC (liquid crystal) layer of an LC cell. The improvement is brought about by direct determination of difference between phases instead of intensities of two components of orthogonal linear polarization of the light passing through an LC cell filled with uniformly oriented molecules. By comparing the experimental data with theoretical result the thickness and pretilt angle are determined more precisely. Further improvement is brought about by use of a liquid gate filled with an index matching liquid in which the LC cell is immersed. Because of the index matching liquid reflection of light at the surfaces of an LC cell almost completely disappears and the range of angle of refraction in the LC layer increases significantly, which gives rise to increased signal to noise ration as well as decreased statistical error. With this improvement precise measurement for either very thin (<10 ${\mu}{\textrm}{m}$) and/or higher pretilt angle($\geq$10$^{\circ}$) LC cells become possible.

  • PDF

Effect of Growth Factors in Doping Concentration of MBE Grown GaAs for Tunnel Diode in Multijunction Solar Cell

  • Park, Gwang-Uk;Gang, Seok-Jin;Gwon, Ji-Hye;Kim, Jun-Beom;Yeo, Chan-Il;Lee, Yong-Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.308-309
    • /
    • 2012
  • One of the critical issues in the growth of multijunction solar cell is the formation of a highly doped Esaki interband tunnel diode which interconnects unit cells of different energy band gap. Small electrical and optical losses are the requirements of such tunnel diodes [1]. To satisfy these requirements, tens of nanometer thick gallium arsenide (GaAs) can be a proper candidate due to its high carrier concentration in low energy band gap. To obtain highly doped GaAs in molecular beam epitaxy, the temperatures of Si Knudsen cell (K-cell) for n-type GaAs and Be K-cell for p-type GaAs were controlled during GaAs epitaxial growth, and the growth rate is set to 1.75 A/s. As a result, the doping concentration of p-type and n-type GaAs increased up to $4.7{\times}10^{19}cm^{-3}$ and $6.2{\times}10^{18}cm^{-3}$, respectively. However, the obtained n-type doping concentration is not sufficient to form a properly operating tunnel diode which requires a doping concentration close to $1.0{\times}10^{19}cm^{-3}$ [2]. To enhance the n-type doping concentration, n-doped GaAs samples were grown with a lower growth rate ranging from 0.318 to 1.123 A/s at a Si K-cell temperature of $1,180^{\circ}C$. As shown in Fig. 1, the n-type doping concentration was increased to $7.7{\times}10^{18}cm^{-3}$ when the growth rate was decreased to 0.318 A/s. The p-type doping concentration also increased to $4.1{\times}10^{19}cm^{-3}$ with the decrease of growth rate to 0.318 A/s. Additionally, bulk resistance was also decreased in both the grown samples. However, a transmission line measurement performed on the n-type GaAs sample grown at the rate of 0.318 A/s showed an increased specific contact resistance of $6.62{\times}10^{-4}{\Omega}{\cdot}cm^{-2}$. This high value of contact resistance is not suitable for forming contacts and interfaces. The increased resistance is attributed to the excessively incorporated dopant during low growth rate. Further studies need to be carried out to evaluate the effect of excess dopants on the operation of tunnel diode.

  • PDF

The Anode Heel Effect caused by changing the Angle of X-Ray Tube (X-선관 각도 변경에 따른 Anode Heel Effect)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.435-442
    • /
    • 2016
  • This study was an investigation of the anode heel effect caused by changing the angle of the x-ray tube. We established the following conditions for experimental measurements: 70 kV, 30 mAs, focus-detector distance of 100cm, and a collimator setting of $35{\times}43cm^2$. The measurement points were set up at the center of the collimator and extended to each side in intervals of 3.5cm, with points A1, A2, A3, A4, A5, A6 on the anode side and points C1, C2, C3, C4, C5, C6 on the cathode side. We measured the entrance surface dose from point A6 to point C6 with each point perpendicular to an x-ray tube. And we did the same when measuring different angles of the x-ray tube from 15 to 30 degrees for every point on the anode and cathode sides. Using perpendicular x-ray tube, we found that the entrance surface dose of the A5 point was three times higher than that of the C5 point. Thus, we conclude that if the anode side is placed near highly radiosensitive organs, then there will be less radiation exposure when using a perpendicular x-ray tube. When imaging using x-ray tube angles, an angle to the cathode side can reduce the gap of the entrance surface dose on both the anode and cathode sides. When imaging areas where there are differences in thickness between the upper and lower sides, the angle to the cathode side that is closer to the thicker area can reduce the gap of the entrance surface dose and capture a higher quality image.

A Study of Limitation of Service Area by UWB Transmission Jamming in DMB System (DMB 시스템에서 UWB 전파가 서비스에 미치는 영향에 관한 연구)

  • Kim, Dong-Ok
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.4 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • In this paper, n system did research about effect that interference effect with neighborhood single equipment or group equipment gets in DMB service. For this, 2.6425 GHz SDMB(Satellite Digital Multimedia Broadcasting) that a special of electric wave interference is near frequency-band including interference of signal by unnecessary radiation level that is radiated in UWB system, and degree of 3.4125GHz broadcasting relay net that is In-band frequency-band and interference effect that get in service analyzed comparison ud, modulation of broadcasting relay net and interference measurement equipment used Impulse and OFDM methods. Impulse method was $BER=1{\times}10^4$ that broadcasting signal receiption is possible at 1.4m point because interference effect happens from 2m point in SDMB system, and it was $BER=1^{\times}10-4$ that OFDM method receives interference effect from 0.8m point and broadcasting signal receiption is possible at 0.5m point. Also, about gap-filler center frequency, in case of space interval more than 0.01m, there was no interference effect. Therefore, for the electric wave of W system that is small output applies to system without interference effect in DMB service, confirmed that UWB system of OFDM method is less interference effect than UWB system of impulse method.

  • PDF