• Title/Summary/Keyword: gap measurement

Search Result 701, Processing Time 0.033 seconds

Measurement of Voltage Transfer Curve in AC PDP (AC-PDP특성평가를 위한 전압전달곡선 계측에 관한 연구)

  • 손진부;이성현;김동현;김영대;조정수;박정후
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.395-398
    • /
    • 1999
  • In ac PDP(plasma Display Panel), the discharge characteristics is very important to display clear images. In this paper, we have studied the measurement of voltage transfer curves which show the discharge characteristics in AC PDP. The change of the effective wall capacitance during a discharge is also studied. These depend on lateral spreading of charge distribution and the strength of the discharge. As a parameter of the frequency, we observed the effects of the frequency in voltage transfer curves and in effective wall capacitance changes. As frequency increases, minimum sustain voltage and firing voltage decrease. In upper region of gap voltage the chance of the effective wall capacitance is independent of frequency.

  • PDF

Distance measurement technique using a mobile camera for object recognition (객체 인식을 위한 이동형 카메라를 이용한 거리 측정 기법)

  • Hwang, Chi-gon;Lee, Hae-Jun;Yoon, Chang-Pyo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.352-354
    • /
    • 2022
  • Position measurement using a camera has been studied for a long time. This is being studied for distance recognition or object recognition in autonomous vehicles, and it is being studied in the field of indoor navigation, which is a limited space where GPS is difficult to apply. In general, in a method of measuring the distance using a camera, the distance is measured using a distance between the cameras using two stereo cameras and a value measured through a captured image or photo. In this paper, we propose a method of measuring the distance of an object using a single camera. The proposed method measures the distance by using the distance between cameras, such as a stereo camera, and the value measured by the photographed picture through the gap of the photographing time and the distance between photographing.

  • PDF

A Study on the Cause and Improvement of Crack in the Installing Structure of the Bulkhead of Aircraft (항공기 Bulkhead 체결구조의 균열 원인 및 개선에 관한 연구)

  • Choi, Hyoung Jun;Park, Sung Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.448-454
    • /
    • 2020
  • This study aims to determine the cause of structural defects occurring during aircraft operations and to verify the structural integrity of the improved features. The fracture plane was analyzed to verify the characteristics of the cracks and the fatigue failure leading to the final fracture was determined by the progress of the cracks by the repeated load. During aircraft operations, the comparative analysis of the load measurement data at the cracks with the aircraft design load determined that the measured load was not at the level of 30% of the design to be capable of being damaged. A gap analysis resulted in a significant stress of approximately 32 ksi at the crack site. Pre-Load testing also confirmed that the M.S. was reduced by more than 50% from +0.71 to +0.43, resulting in a sharp increase in aircraft load and the possibility of cracking when combined. Thus, structural reinforcement and the removal of the gap for aircraft cracking sites improved the defect. Based on the structural strength analysis of the improvement features, the bulkhead has a margin of about +0.88 and the fitting feature is about +0.48 versus allowable stress. In addition, the life analysis results revealed an improvement of approximately 84000 hours.

Influence of lossy ground on impulse propagation in time domain for impulse ground penetrating radar (초광대역 임펄스 지반탐사레이더에서 지면의 영향에 따른 임펄스 전파 특성 연구)

  • Kim, Kwan-Ho;Park, Young-Jin;Yoon, Young-Joong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.11
    • /
    • pp.42-47
    • /
    • 2007
  • In this paper, influence of lossy ground and gap variation between lossy ground and UWB antenna on impulse propagation in time domain for impulse ground penetrating radar (GPR) is numerically and experimentally investigated. For this study, a novel planar UWB fat dipole antenna is developed. First, influence of lossy ground and gap variation between lossy ground and UWB antenna is simulated. For verification, a test field of sand and wet clay soil is built and using the developed dipole antenna, transmission behavior is investigated at the test field. With an aid of IDFT (inverse discrete Fourier transform), time domain impulse response for transmission coefficient measured and simulated in frequency domain is obtained. Measurement and simulation show that the frequency of maximum transmission coefficient and transmission coefficient are increased with higher dielectric constant and larger gap distance. In time domain, it is shown that for higher dielectric constant, the amplitude of the received signal in time domain is higher and reflected signals are seriously modified. Also, it is found that variation of gap between antenna and ground surface makes timing of peak value changed.

IN VITRO MARGINAL FIT OF THE COMPUTERAIDED MILLED CERCON CROWNS

  • Chang, Jae-Yoon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.306-313
    • /
    • 2005
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But most of statistical inferences are not definite because of sample size, measurement number, measuring , instruments, etc. And there have been few studies about the marginal fit of Computer-aided Cercon crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made using computer-aided milled Cercon crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and methods. The in vitro marginal discrepancies of computer-aided milled Cercon crowns and control groups (metal ceramic crowns) were evaluated and compared. The crowns were made from one extracted maxillary central incisor prepared by milling machine. 30 crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Results. The means and standard deviations of the marginal fit were 85$\pm$22$\mu$m for the control group and 91$\pm$15$\mu$m for the Cercon crowns. The t-test of the marginal discrepancies between Cercon crowns and metal-ceramic crowns were performed. Significant differences were not found between groups (P=0.230>.05). Based on the criterion of 120$\mu$m as the limit of clinical acceptability, the mean marginal fits of Cercon crowns and metal-ceramic crowns were acceptable. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were 85$\pm$22$\mu$m for the control (metal-ceramic crowns), 91$\pm$15$\mu$m for Cercon crowns. 2. The Cercon crowns showed slightly larger marginal gap discrepancy than the control but marginal gap between Computer-aided milled Cercon crowns and metal ceramic crowns did not showed significant difference (P>.05). 3. The Cercon crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.

Measurement and Evaluation of Scatter Fractions for Digital Radiography with a Beam-Stop Array (Beam-Stop Array를 이용한 DR에서의 Scatter Fraction 측정 및 효용성 평가)

  • Choi, Yu-Na;Cho, Hyo-Min;Kim, Yi-Seul;An, Su-Jung;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • Scatter radiation considerably affects radiographic image quality by reducing image contrast and contributing to a non-uniform background. Images containing a large portion of scatter radiation may result in an incorrect diagnosis. In the past few years, many efforts have been made to reduce the effects of scatter radiation on radiographic images. The purpose of this study is to accurately measure scatter fractions and evaluate the effectiveness of beam-stop arrays. To measure scatter fraction accurately, a beam-stop array and the SFC (Scatter Fraction Calculator) program were developed. Images were obtained using the beam-stop array for both an anti-scatter technique with an anti-scatter grid and an air gap technique. The scatter fractions of the images were measured using the SFC program. Scatter fractions obtained with an anti-scatter grid were evaluated and compared to scatter fractions obtained without an anti-scatter grid. Scatter fractions were also quantitatively measured and evaluated with an air gap technique. The effectiveness of the beam-stop array was demonstrated by quantifying scatter fractions under various conditions. The results showed that a beam-stop array and the SFC program can be used to accurately measure scatter fractions in radiographic images and can be applied for both developing scatter correction methods as well as systems.

MARGINAL FIT OF CELAY/IN-CERAM, CONVENTIONAL IN-CERAM AND EMPRESS 2 ALL-CERAMIC SINGLE CROWNS (Celay/In-Ceram, Conventional In-Ceram, Empress 2 전부도재관의 변연적합도에 관한 비교 연구)

  • Yang, Jae-Ho;Yeo, In-Sung;Lee, Sun-Hyung;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.131-139
    • /
    • 2002
  • There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But many of statistical inferences are not definite because of sample size, measurement number, measuring instruments. etc. The purpose of this study was to compare the marginal adaptations of the anterior single restorations made by different systems and to consider more desirable statistical methods in analysing the marginal fit. The in vitro marginal discrepancies of three different all-ceramic crown systems (Celay In-Ceram. Conventional In-Ceram. IPS Empress 2 layering technique) and one control group (PFM) were evaluated and compared. The crowns were made from one extracted maxillary central incisor prepared with a 1mm shoulder margin and $6^{\circ}$ taper walls by milling machine. 10 crowns per each system were fabricated. Measurements or a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Non-parametric statistical analysis was performed for the results. Within the limits of this study, the following conclusions were drawn: 1 Mean gap dimensions and standard deviations at the marginal opening for the maxillary incisor crowns were $98.2{\pm}40.6{\mu}m$ for PFM, $83.5{\pm}18.7{\mu}m$ for Celay In-Ceram, $104.9{\pm}44.1{\mu}m$ for conventional In-Ceram, and $45.5{\pm}11.5{\mu}m$ for IPS Empress 2 layering technique. The IPS Empress 2 system showed the smallest marginal gap (P<0.05). The marginal openings of the other three groups were not significantly different (P<0.05). 2 The marginal discrepancies found in this study were all within clinically acceptable standards ($100\sim150{\mu}m$). 3. When the variable is so controlled that the system may be the only one, mean value is interpreted to be the marginal discrepancy of a restoration which is made by each system and standard deviation is to be technique-sensitivity of each one. 4. From the standard deviations. the copy-milling technique (Celay/In-Ceram) was not considered to be technique-sensitive in comparison with other methods. 5. Parametric analysis is more reliable than non-parametric one in interpretation of the mean and standard deviation. The sample size of each group has to be more than 30 to use parametric statistics. The level of clinically acceptable marginal fit has not been established. Further studies are needed.

The Influence of Microwave Sintering Process on the Adaptation of CAD/CAM Zirconia Core (마이크로 웨이브 소결 과정이 CAD/CAM 지르코니아 코아의 적합도에 미치는 영향)

  • Kim, Keun Bae;Kim, Jee Hwan;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.95-107
    • /
    • 2009
  • The purpose of this research was to examine the fitness of zirconia cores that were made by different sintering methods; generic electricity furnace and microwave furnace. Firstly, 12 cores for each group were made by using each different sintering process and attached them to a metal die with silicon. The internal and marginal gap of sintered zirconia was measured by using Skyscan 1076 micro-CT, then it was reorganized by CT-An software. To each samples, we extracted B-L image, M-D image of cutting side, and cross-sectional side of tooth long axis and calculated the mean value of marginal, axial, and occlusal gap each side. Results: 1. The mean marginal gap of sintered zirconia was $36.20{\mu}m$ for EVE, $47.67{\mu}m$ for LAV, $52.47{\mu}m$ for DEN, and $54.63{\mu}m$ for CER. 2. For the axial wall, the research showed the largest value of $63.49{\mu}m$ for EVE, but there were no statistical significance. 3. In related to the occlusal internal measurement, DEN showed the smallest value ($77.06{\mu}m$), EVE and CER showed significantly high value. From this study, it is suggested that CAD/CAM zirconia core which was made in the process of microwave sintering has clinically acceptable values in marginal and internal gap.

Correlation Analysis of Reduction for Intra-Articular Calcaneal Fracture and Clinical Outcomes Using Postoperative Computed Tomography (수술 후 컴퓨터 단층촬영을 이용한 관절 내 종골 골절의 정복과 임상 결과 간의 연관성 분석)

  • Eom, Joon-Sang;Joo, Young-Deuk;Kim, Seong-Jun;Shin, Min-Ho;Lee, Dong-Oh;Jung, Hong-Geun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.4
    • /
    • pp.165-172
    • /
    • 2014
  • Purpose: We evaluated the correlation of postoperative clinical outcomes and radiologic findings using computed tomography and simple X-ray in intra-articular calcaneal fractures. Materials and Methods: The current study is based on 41 feet, 38 patients with displaced intra-articular fracture who underwent surgical treatment with at least one year of follow-up. Evaluation of clinical outcome included American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS) score, and subjective satisfaction. A simple X-ray was used in evaluation of preoperative and postoperative Gissane angle, B${\ddot{O}}$hler angle, and calcaneal fracture width. Computed tomography scan was performed for evaluation of preoperative and postoperative articular step-off and articular gap in all cases. Finally, we evaluated the correlation of the postoperative clinical outcomes and radiologic findings based on the measurement. Results: The average postoperative AOFAS score and VAS score was $84.1{\pm}8.5$ and $2.2{\pm}2.2$. Subjective satisfaction was excellent in 15 cases, good in 19 cases, and fair in seven cases. The average B${\ddot{O}}$hler angle was restored from $11.1^{\circ}$ to $24.7^{\circ}$(p<0.05), Gissane angle was changed from $121.0^{\circ}$ to $119.0^{\circ}$ (p>0.05), and the average width was restored from 45.8 to 35.0 mm (p<0.05). The average articular step-off and gap were decreased from 6.3 to 2.0 mm and from 11.1 to 4.6 mm, respectively (p<0.05). No significant correlations were observed between the clinical outcome and Gissane angle, B${\ddot{O}}$hler angle, and width, and there was no significant correlation between the clinical outcome and Sanders classification. However, postoperative articular step-off showed correlation with VAS and AOFAS score and articular gap showed correlation with VAS score. Conclusion: The clinical outcome did not show correlation with B${\ddot{O}}$hler angle and Gissane angle but did show correlation with anatomical reduction of the posterior facet joint.

Error Analysis for Microwave Permittivity Measurement using Post Resonator Method (Post Resonator 방법에 의한 마이크로파 유전율 측정에서의 오차 분석)

  • Cho, Mun-Seong;Lim, Donggun;Park, Jae-Hwan;Park, Jae-Gwan
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.3
    • /
    • pp.43-48
    • /
    • 2012
  • Errors of relative permittivity calculation caused by the variation of sample aspect ratio (diameter/height) and measuring geometry were analyzed by computer simulation and measurement. Firstly, the $S_{21}$ spectrum of the sample (permittivity 38) was simulated in the post resonator measuring apparatus by HFSS simulation. Then, the relative permittivity was calculated from the $TE_{011}$ mode resonant frequency. The relative permittivity varied by ca. 0.3% with sample aspect ratio variation (D/H=0.8~1.6). The relative permittivity varied by ca. 1~10% when the 1~10% of air-gap was introduced in between the dielectric disk and upper conductor. All the simulation results showed consistent tendency with real measurement.