• Title/Summary/Keyword: gap measurement

Search Result 701, Processing Time 0.024 seconds

Optimal Portfolio Models for an Inefficient Market

  • GINTING, Josep;GINTING, Neshia Wilhelmina;PUTRI, Leonita;NIDAR, Sulaeman Rahman
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.2
    • /
    • pp.57-64
    • /
    • 2021
  • This research attempts to formulate a new mean-risk model to replace the Markowitz mean-variance model by altering the risk measurement using ARCH variance instead of the original variance. In building the portfolio, samples used are closing prices of Indonesia Composite Stock Index and Indonesia Composite Bonds Index from 2013 to 2018. This study is a qualitative study using secondary data from the Indonesia Stock Exchange and Indonesia Bonds Pricing Agency. This research found that Markowitz's model is still superior when utilized in daily data, while the mean-ARCH model is appropriate with wider gap data like monthly observation. The Historical return has also proven to be more appropriate as a benchmark in selecting an optimal portfolio rather than a risk-free rate in an inefficient market. Therefore Mean-ARCH is more appropriate when utilized under data that have a wider gap between the period. The research findings show that the portfolio combination produced is inefficient due to the market inefficiency indicated by the meager return of the stock, while bears notable standard deviation. Therefore, the researcher of this study proposed to replace the risk-free rate as a benchmark with the historical return. The Historical return proved to be more realistic than the risk-free rate in inefficient market conditions.

High Shock-Resistant Design of Piezoresistive High-g Accelerometer

  • Yongle Lu;Zhen Qu;Jie Yang;Wenxin Wang;Wenbo Wang;Yu Liu
    • Journal of Information Processing Systems
    • /
    • v.19 no.2
    • /
    • pp.173-188
    • /
    • 2023
  • To improve the shock-resistance of piezoresistive high-g accelerometer, we propose a design of piezoresistive high-g accelerometer. The accelerometer employs special-shaped proof masses system with a cross gap. Four tiny sensing beams are bonded above the cross gap. The expression of the deformation, natural frequency and damping is deduced, and the structural parameters are optimized. The accelerometer structure is simulated and verified by finite element method (FEM) simulation. The results show that the range of the accelerometer can reach 200,000 g, the natural frequency is 453.6 kHz, and the cross-axis sensitivity of X-axis and Y-axis is 0.25% and 0.11%, respectively, which can apply to the measurement of high shock. Contrastively, the cross-axis sensitivity of X-axis and Y-axis is respectively, reduced by 93.2% and 96.9%. The sensitivity of our accelerometer is 0.88 μV/g. It is of great value for the application of piezoresistive high-g accelerometer with high shock-resistance.

Effects of Setaria italica on Gap Junction-Mediated Intercellular Communication for the Development of Cancer Chemopreventive Agents

  • Son, Jang-Won;Fang, Ming-Zhu;Cho, Myung-Haing;Kim, Kyung-Ho;Kim, Soo-Un;An, Gil-Hwan;Lee, Chong-Soon;Kim, Ki-Nam;Chang, Il-Moo;Mar, Woong-Chon
    • Natural Product Sciences
    • /
    • v.5 no.2
    • /
    • pp.88-92
    • /
    • 1999
  • Inhibition of gap junction-mediated intercellular communication (GJIC) has been considered as an important factor in the tumor promotion phase of carcinogenesis. Recovery effects of natural products on gap junctional intercellular communication are measured by scrape-loading and dye transfer method using Lucifer yellow after administration of phorbol-12-myristate-13-acetate (PMA) on WBF344 cells. Among tested natural products, the hexane fraction and subfractions (F-01 and F-04) of Setaria italica were relatively effective for recovery of GJIC. The hexane fraction of Setaria italica $(EC_{25},\;12.14\;{\mu}g/ml)$ and subfractions $(F-01:EC_{50},\;10.74\;{\mu}g/ml;EC_{25},\;1.58\;{\mu}g/ml,\;F-04:EC_{50},\;11.03\;{\mu}g/ml;\;EC_{25},\;3.12\;{\mu}g/ml)$ revealed dose-dependent recovery effects on GJIC. Our data show GJIC activity measurement by Lucifer yellow spread on cells can be an effective tool for the screening of natural products with possible cancer chemopreventive effects.

  • PDF

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

Effect of Nd:YAG laser irradiation on adherence of retrograde filling materials: evaluation by micro-computed tomography

  • Kim, Minyoung;Kim, Hyeon-cheol;Kwak, Sang Won;Yoon, Tai Cheol;Kim, Euiseong
    • The Journal of the Korean dental association
    • /
    • v.54 no.11
    • /
    • pp.865-873
    • /
    • 2016
  • Background/Purpose: The purpose of this study was to evaluate the effect of Nd:YAG irradiation on adherence of retrograde filling materials (mineral trioxide aggregate [MTA] and Super-EBA) by micro-computed tomography (CT) measurement and to observe the dentinal surface after irradiation by scanning electron microscopy (SEM). Materials and methods: Forty retrofilling models using extracted human teeth were divided into four groups according to the material and method used: ProRoot MTA (MTA group), Super-EBA (EBA group), MTA with Nd:YAG laser irradiation (LMTA group), and Super-EBA with Nd:YAG laser irradiation (LEBA group). All specimens were stored in 100% humidity for 24 hours until micro-CT was performed. The gap volume of the tooth/material interface was measured using the CTAn program. In six samples, the laser-irradiated dentin surface was observed using SEM. Results: The mean percent difference in gap volume was not statistically significant between the Nd:YAG laser-irradiated groups and non-irradiated in both materials(P > 0.05). The gap volume in the MTA group was significantly lower than that in the EBA group (P < 0.05). Examination of the non-irradiated specimens by SEM showed patent dentinal tubules. In contrast, alterations in the texture of the dentin surface and obliteration of the dentinal tubules were evident in the Nd:YAG laser-irradiated specimens. Conclusion: In this study, changes in the dentinal surface after Nd:YAG irradiation did not affect adherence between the apical filling material and the dentin wall.

  • PDF

A Study on Intelligent Image Database based on Fuzzy Set Theory (퍼지이론에 기초한 지적 감성검색시스템에 관한 연구)

  • 김돈한
    • Archives of design research
    • /
    • v.14 no.4
    • /
    • pp.5-14
    • /
    • 2001
  • Among Human Sensibility-oriented products a gap between the images that designers try to express through that product and users emotional evaluation becomes an issue. The data on the correlation between image words used for design evaluation and images used in the design process are especially significant. This study based on these correlations suggests a Fuzzy retrieval system supporting styling design with images and image words. In the system, the relational data are demonstrated by Fuzzy thesaurus as correlation coefficient from the degree of similarity among image words. And the degree of similarity is produced based on image evaluation. Image retrieval is conducted by the algorithm of Fuzzy thesaurus development, 1) among image words, 2) images to image words, 3) image words to images and 4) among images: 4 different modes are provided as retrieval modes. Also transfer between modes is carried by direct operating interface, therefore divergent thinking and convergent thinking is supported well. The system consists of operation for the gap and the measurement unit of emotional evaluation, and visualization units. Under unified interface environments are set in order for consistency of the operation.

  • PDF

Characterization of Particle Size Distribution of Infiltrated Secondhand Smoke through the Gap in a Single Glazed and a Secondary Glazed Window by Indoor and Outdoor Pressure Differences (실내외 압력 차에 따른 단창과 이중창의 틈새로 침투된 간접흡연의 입자 크기 분포 특성)

  • Kim, Jeonghoon;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.360-369
    • /
    • 2018
  • Objectives: Outdoor tobacco smoke can penetrate into the indoor environment through cracks in the building envelope. This study aimed to characterize the particle size distribution of infiltrated secondhand smoke (SHS) through the gap in a single glazed and a secondary glazed window according to pressure differences in a chamber. Methods: Two polyvinyl chloride sliding windows were evaluated for infiltration, one with a glazed window and the other with a secondary glazed window. Each window was mounted and sealed in a polycarbonate chamber. The air in the chamber was discharged to the outside to establish pressure differences in the chamber (${\Delta}P$). Outdoor smoking sources were simulated at a one-meter distance from the window side of the chamber. The particle size distribution of the infiltrated SHS was measured in the chamber using a portable aerosol spectrometer. The particle size distribution of SHS inside the chamber was normalized by the outdoor peak for fine particles. Results: The particle size distribution of SHS inside the chamber was similar regardless of window type and ${\Delta}P$. It peaked at $0.2-0.3{\mu}m$. Increases in particulate matter (PM) concentrations from SHS infiltration were higher with the glazed window than with the secondary glazed window. PM concentrations of less than $1{\mu}m$ increased as ${\Delta}P$ was increased inside the chamber. Conclusions: The majority of infiltrated SHS particles through window gap was $0.2-0.3{\mu}m$ in size. Outdoor SHS particles infiltrated more with a glazed window than with a secondary glazed window. Particle sizes of less than $1{\mu}m$ were associated with ${\Delta}P$. These findings can be a reference for further research on the measurement of infiltrated SHS in buildings.

The Effects of Rudder Size on Characteristics of Fluid Flow around Ship's Stern in Manoeuvring Motion (타의 크기가 조종운동시 선미 유동 특성에 미치는 영향)

  • 손경호;김용민
    • Journal of the Korean Institute of Navigation
    • /
    • v.25 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • It is well known that, especially in the case of full-bodied ship, the course stability may become the severest among 4 items of requirement in Interim Standards for Ship Manoeuvrability adopted by IMO in 1993. The purpose of this study is to find some ideas for characteristics of fluid flow pattern around ship's stern in manoeuvring motion with parameter of changes in rudder size. We carried out two kinds of model experiment in obliquely running condition at circulating water channel. One is measurement on straightening effect of incoming flow to rudder and the other is experiment on flow visualization around the gap between rudder and stern-bottom. We discuss the correlation between the flow characteristics around ship's stem and flow straightening effect at rudder from the viewpoint of course stability. As a result, it is clarified that the gap between rudder and stern-bottom plays an important role in course stability of full-bodied ship. It is pointed out that there is quite a possibility of bad course stability as the gap between rudder and stern-bottom decreases.

  • PDF

A Study on the Band Characteristics of ZnSe Thin Film with Zinc-blende Structure (Zinc Blende 구조를 가지는 ZnSe 결정의 밴드 특성에 관한 연구)

  • Park, Jeong-Min;Kim, Hwan-Dong;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.3
    • /
    • pp.145-151
    • /
    • 2011
  • ZnSe, as a II-VI compound semiconductor which has a wide band gap in the visible region is applicable to the various fields such as laser diode, display and solar cell. By using the electrochemical deposition method, ZnSe thin film was synthesized on the ITO glass substrate. The synthesis of ZnSe grains and their structure having zinc blende shape were verified through the analysis of XRD and SEM. UV spectrophotometric method determined the band gap as the value of 2.76 eV. Applying the DFT (Density Functional Theory) in the molecular dynamics, the band structure of ZnSe grains was analyzed. For ZnSe grains with zinc blende structure, the band structure and its density of state were simulated using LDA (Local Density Approximation), PBE (Perdew Burke Ernzerhof), and B3LYP (Becke, 3-parameter, Lee-Yang-Parr) functionals. Among the calculations of energy band gap upon each functional, the simulated one of 2.65 eV based on the B3LYP functional was mostly near by the experimental measurement.

MARGINAL FIT OF THE DIGIDENT CAD/CAM ZIRCONIA CERAMIC CROWNS

  • Kim Yong-Sun;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.275-283
    • /
    • 2006
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. However most of the statistical inferences are not definite because of sample size, measurement number, measuring instruments, etc, and there have been few studies about the marginal fit of the Digident CAD/ CAM zirconia ceramic crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made by using the Digident CAD / CAM zirconia ceramic crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and Methods. The crowns were made from one extracted maxillary central incisor pre-pared with a 1mm shoulder margin and $6^{\circ}$ taper walls by milling machine. The in vitro marginal discrepancies of the digident CAD / CAM zirconia ceramic crowns and control groups(metal ceramic crowns) were evaluated and compared. Twenty crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were $88{\pm}10{\mu}m$ for the control (metal-ceramic crowns), $92{\pm}4{\mu}m$ for Digident CAD / CAM zirconia ceramic crowns. 2. Marginal gap between Digident CAD / CAM zirconia ceramic crowns and metal ceramic crowns did not show significant difference (P>.05). 3. The Digident CAD/ CAM zirconia ceramic crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.