• Title/Summary/Keyword: gap line

Search Result 570, Processing Time 0.033 seconds

Word Segmentation in Handwritten Korean Text Lines based on GAP Clustering (GAP 군집화에 기반한 필기 한글 단어 분리)

  • Jeong, Seon-Hwa;Kim, Soo-Hyung
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.6
    • /
    • pp.660-667
    • /
    • 2000
  • In this paper, a word segmentation method for handwritten Korean text line images is proposed. The method uses gap information to segment words in line images, where the gap is defined as a white run obtained after vertical projection of line images. Each gap is assigned to one of inter-word gap and inter-character gap based on gap distance. We take up three distance measures which have been proposed for the word segmentation of handwritten English text line images. Then we test three clustering techniques to detect the best combination of gap metrics and classification techniques for Korean text line images. The experiment has been done with 305 text line images extracted manually from live mail pieces. The experimental result demonstrates the superiority of BB(Bounding Box) distance measure and sequential clustering approach, in which the cumulative word segmentation accuracy up to the third hypothesis is 88.52%. Given a line image, the processing time is about 0.05 second.

  • PDF

Series-Gap Characteristics of Polymeric Arrester for Transmission Line (송전선로용 폴리머 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, Young-Sun;Kim, Jong-Che
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.491-492
    • /
    • 2008
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

Series-Gap Characteristics of Transmission Line Arrester with Switching and Lightning Impulse Flashover Test (개폐서지 및 뇌충격 섬락시험에 따른 송전 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.484-485
    • /
    • 2007
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

A Study on Productivity Improvement in Narrow Gap TIG Welding (Narrow Gap 맞대기 TIG 용접에서 생산성 향상을 위한 연구)

  • Jun, Jae-Ho;Kim, Sung-Ryul;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.34 no.1
    • /
    • pp.68-74
    • /
    • 2016
  • Adoption of narrow gap welding shall be increased for the butt joint of thick plate, because the deformation and welding cost is reduced by decrease of cross-sectional area. However, sometimes narrow gap causes defects such as lack of fusion since it has small groove angle and narrow groove width. Therefore, GMAW, GTAW and SAW process shall be adopted to narrow gap welding with small bead hight and low deposition rate. In this study, Super-TIG welding using C-type strip was applied to semi-narrow gap butt joint in order to increase the welding productivity. High deposition rate 10kg/hr was obtained by high current 600A without undercut, humping bead and other welding defects. Measuring the mean and standard deviation of the melting depth to evaluate the developed processes, the fusion line type was determined by measuring the difference between maximum and minium melting depth. Furthermore, a model on arch fusion line and linear fusion line was suggested in order to prevent LF on groove wall in narrow gap butt welding.

Analysis of surface flashover along shield gap inner vacuum interrupter (진공 인터럽터 내부 쉴드간 gap에 따른 연면방전 특성파악)

  • Yoon, Jae-Hun;Lee, Seung-Su;Lim, Kee-Jo;Kim, Sung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.103-104
    • /
    • 2008
  • this paper describes the electric field distribution analysis along a shield gap inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method and experiment at shield gap. in result, The equipotential line and electric field distribution was affected to VI shield gap. The reason is as it gets distortion of equipotential line done. finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

A Type Test of 154 kV Transmission Line Arrester for improvement of lightning performance (내뢰성 향상을 위한 154 kV 송전선용 피뢰기의 성능 시험)

  • Kwak, J.S.;Kang, Y.W.;Woo, J.W.;Shim, E.B.;Kim, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.454-456
    • /
    • 2003
  • This paper describes a type test results of 154 kV transmission line arrester with external gap. The test was carried on surge arrester unit and line arrester with external gap, respectively. Withstand voltage test demonstrate the voltage withstand capability of the line arrester with external series gap under the dry and wet conditions. In insulation coordination test external series gap shall be discharged every time when lightning impulse voltage with the steepness of more than 1500 $kV/{\mu}s$ are applied under the wet condition.

  • PDF

Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode (선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

A Study on the Measurement Error Induced by Air Gap of Electromagnetic Wave Absorber in the Coaxial Line Method (동축선법을 이용한 전파흡수체 특성 측정시 Air Gap에 의한 오차에 대한 연구)

  • 김경용;김왕섭;주윤돈;김병호
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.11
    • /
    • pp.874-879
    • /
    • 1991
  • The effect of air gap between specimen and jig on the material constant (permittivity, permeability) and attenuation characteristics of electromagnetic wave absorbers in the coaxial line method was investigated. The presence of a air gap made both permittivity and permeability measured lower than true value, and the tendency was greater in the case of permittivity. An inner gap compared to an outer gop was found to yield a larger difference between measured and true values. The effect of air gap was measured for a Ni0.3Zn0.7Fe2O4, with the gap eliminated by metallizing with Ag-paste. The measured characteristics were in good agreement with corrected values by calculation.

  • PDF

Formation of Fine Line and Series Gap Resonator Using the Photoimageable Thick Film Technology (후막 광식각 기술을 이용한 미세라인 및 Series Gap Resonator의 구현)

  • 박성대;이영신;조현민;이우성;박종철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.3
    • /
    • pp.69-75
    • /
    • 2001
  • Photoimageable thick film technology is a new technology in that the lithography process such as exposure and development is applied to the conventional thick film process. Line resolution of 25 $\mu\textrm{m}$ width and 25 $\mu\textrm{m}$ space could be obtained by laminating green sheet, printing photoimageable Ag paste, exposing the test patterns, developing, and co-firing. In case of using the alumina substrate, 20 $\mu\textrm{m}$ fine line could be also obtained by similar process. Test results showed that exposing power density and developing time were the most important processing parameters for the fine line formation. Microstrip and series gap resonators with well-defined line morphology and good transmission characteristics in high frequency were formed by this new technology, and thereby dielectric constant and loss of test substrate were calculated.

  • PDF

The Design, Manufacture and Applications of a Gap Noise Generator for Testing the Characteristics of EMI from Transmission Lines (송전선로 EMI 특성 실험용 인공잡음발생장치 설계, 제작 및 적용)

  • Ju, Yun-Ro;Yang, Gwang-Ho;Myeong, Seong-Ho;Lee, Dong-Il;Sin, Gu-Yong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.23-28
    • /
    • 2002
  • In order to survey the radiation characteristics of pure line noise of unwanted noise from overhead high voltage AC transmission lines, a disk type gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by using surface charge method. The capacitance is one of principal parameters related to the injection of a proper noise current into lines. On the basis of the capacitance obtained from calculation, 5mm of space was given to the gap of the noise generator to be installed o test line and an aluminum disk of 60cm radius was made. The field experiments were performed with the noise generator hung on the Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines were obtained. Those are the directivity of antenna toward the line, lateral profiles, frequency spectra, height pattern and so on.