• Title/Summary/Keyword: gamma ray dose

Search Result 479, Processing Time 0.024 seconds

Effect of CJ-50001 (rG-CSF) on the Recovery of the Neutrophil Numbers in the Mice with Bone Marrow Transplantation BMT) (CJ-50001 (rG-CSF)의 골수이식모델 마우스에 대한 호중구수 회복 촉진효과)

  • 임동문;조효진;김종호;김달현;고형곤;김제학;김현수
    • Biomolecules & Therapeutics
    • /
    • v.5 no.4
    • /
    • pp.376-379
    • /
    • 1997
  • The peripheral neutrophil recovery test was conducted to determine the efficacy of CJ-50001, a drug developed in Cheil Jedang R&D center as a recombinant granulocyte-colony stimulating factor (rG-CSF). Grasin was used as control drug. CJ-50001 and Gratin were subcutaneously administered to ${\gamma}$-ray irradiated mice for 21 days at a dose of 10$\mu$g/kg after bone marrow transplantation and the recovery of neutrophil number was examined on the days of 9, 13, 17, and 21 after the drug administration. It was observed that the peripheral neutrophil number of the vehicle control group was recovered to the normal level on the day of 13 after the transplantation whereas the group administered with CJ-50001 and Grasin respectively, showed the normal level of peripheral neutrophil number on 9th day after the bone marrow transplantation. The number of peripheral neutrophils reached the highest level on the 21 st day of drug administration, and was recovered to the normal level on the 4th day after ceasing of the drug administration (on the 25th day of the transplantation). Thus, it was presumed that CJ-50001 showed efficacy similar to Grasin on the peripheral neutrophil recovery after bone marrow transplantation.

  • PDF

An Experimental Study on the Change of Bone Mineral Metabolism After Irradiation (방사선 조사후 골무기질 함량의 변화에 관한 실험적 연구)

  • Hong, Sung-Woon;Lim, Sang-Moo;Jang, Ja-June;Lee, Jhin-Oh;Kang, Tae-Woong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.307-316
    • /
    • 1990
  • Irradiation is widely used for the treatment of malignant diseases, and possibly cause the osteoporosis. The densitometry and bone scintigraphy are valuable when used to monitor the patients longitudinally to access the progression of osteoporosis and risk of osteoradionecrosis. To evaluate the osteoporosis after irradiation of Cobalt-60 gamma ray on the lumbar spines of New Zealand white rabbits, bone densitometry by dual photon absorptiometry and bone scintigraphy were performed weekly. The decrease of bone density began at the first week after irradiation, and were in the nadir at 4-6th week. The osteoblastic activity measured by bone scintigraphy decreased in the first week, and was in the nadir at 4-6th week. The severity of these changes were related to the radiation dose. In conclusion, the osteoporosis before the presentation of the osteoradionecrosis can be diagnosed early with the dual photon absorptionmetry and bone scintigraphy.

  • PDF

Effects of Plasticizer to Polyvinylchloride on Radio-resistance of Organic Stabilizer,Dielectric and Mechanical Characteristics under the Influence of Radiation (Polyvinylchloride에 있어 가소제의 첨가가 유기안정제의 내 방사성 및 유전, 기계적 특성에 미치는 영향)

  • 김봉흡;강도열;이재인
    • 전기의세계
    • /
    • v.26 no.2
    • /
    • pp.89-94
    • /
    • 1977
  • In order to investigate the properties of radiation resistance together with dielectric, and mechanical relaxation behaviors of polyvinylcholoride exposed to several different doses under the .gamma.-ray of Co$^{60}$ source, several observations were carried out on the exposed specimens propared by mixing dibutyl-tin-dilaulate and dibutyl-tin-dimaleate as stabilizer with or without adding dioctyl-phthalate as plasticizer. Conclusions obtained from the study are as follows: The origin of the absorption band at 1,540-1,640$cm^{-1}$ / on I.R. spectrum seems to be RCOO- ion originated from ionization of the stabilizer, and this peak can be useful as a measure of radiation resistance on polyvinylchloride. Addition of increasing plasticizer to polyvinylchloride exhibits increasing radiation resistance and the reason for this result may be attributed to aromatic resonance absorption of radiation energy by diotylphthalate. On dose dependent dielectric characteristics, nonplastized specimen shows a peak at about 10 Mrad and that this peak disappears on the plastification of specimens. Those phenomena may be explainable in considering the statistical distribution of scissored chain molecular segments as well as the plastification process of plasticizer to polyvinylchloride chain molecules.

  • PDF

Radiation Degradation Detection of LDPE Using Thermoluminescence Method (열발광 특성을 이용한 저밀도 폴리에틸렌의 방사선 열화 검출)

  • Lee, C.;Lee, K.W.;Park, J.N.;Lim, K.J.;Ryu, B.H.;Park, Y.G.;Kang, S.H.;Kim, K.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.43-46
    • /
    • 2001
  • Polymers are widely used as insulating materials at various part of power industry. However, electrical properties of these polymers are easily degraded with their working environments, especially radiation areas. In this research, radiation degradation of low density polyethylene (LDPE) used as cable insulation was evaluated with thermoluminescence characteristics. LDPE was irradiated with gamma ray up to 1000 kGy at a dose rate of 5 kGy/hr in the presence of air at room temperature. Each of the irradiated samples were carried out thermoluminescence analysis as a function of temperature. Interrelationships between thermoluminescence and dielectric characteristics and volume resistivity are investigated as well. The results of thermoluminescence analysis showed that those would be significant factors for evaluation of radiation degradation.

  • PDF

Isolation and Characterization of Ultra-Violet and Gamma-radiation Resistant Bacteria from Natural Habitats (자연 생태계로 부터 자외선 및 방사선 내성 박테리아의 분리 및 특성 연구)

  • 이영남;이인정
    • Korean Journal of Microbiology
    • /
    • v.27 no.3
    • /
    • pp.297-303
    • /
    • 1989
  • Attempts to isolate the naturally occurring ultra-violet resistant bacteria from environmental sources were made. The isolates, designated No.29, 100, and 107, among numbers of bacterial isolates revealed a remarkable resistance to UV ray, whose degree of resistance in dose/response kinetics was comparable to that of an endospore-former, Bacillus subtilis. In a range of 100-300 $Jm^{-2}$/min of UV irradiation, the isolates exhibited 500-1000 fold resistance compated with E. coli. The isolated appeared to possiss cell-bound pigment of organge or crimson-red. The isolate 29 is spherical in pairs or tetrads, whereas the isolates 100 and 107 are rod. All are Gram-gositive bacteria and seemed to be non-endospore-bearer. A number of biochemical studies pursued on the isolates suggested that they are quite different to each other. Electron microscopic examination and the physiological characters of the isolate 29 suggested that this UV resistant spherical bacterium might be one species of Deinococcus, probably Deinococus radiophilus. Since there is no documents on UV resistant, Gram-positive, non-sporeformer bacillus so far, the isolates 100 and 107 might be turned out as new kinds of UV resistant bacteria occurring in nature by further investigation.

  • PDF

AN EXPERIMENTAL STUDY OF THE IRRADIATION EFFECTS ON RAT SUBMANDIBULAR GLAND (방사선 조사가 백서 악하선조직에 미치는 영향에 관한 실험적 연구)

  • Lee Chang Hwan;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.139-148
    • /
    • 1990
  • The purpose of this study was to investigate the effects of irradiation on the rat submandibular gland which composed of the epithelial growth factors. The experimental animals were the Sprague Dawley strain rats, which were the rats as the non-irradiated control group and the rats as the experimental group which were divided into groups as the experimental duration of 1 hour, 3 hours, 6 hours, 12 hours, 1 day, 3 days, 1 week, 2 weeks, 4 weeks. The experimental animals were singly irradiated at a dose of 8 Gray gamma ray to their head and neck region by the Co-60 teletherapy unit and sacrificed after each experimental duration. The specimens were stained with H-E and Azan stain and examined light microscopically. The results of this study were obtained as follows. 1. The all of mucous and serous acini in submandibular gland showed similar pattern of changes in structure according to the lapse of time. 2. The acinic cells started to change after 1 hour, and repaired after 12hours with mitosis and proliferation of the cells between acini. The changes were marked after 1day, and repaired gradually in course of time. 3. The duct were dilatated irregularly, and the outline of the eosinophilic stained ductal cells changed indistinctly.

  • PDF

EFFECTS OF TEMPERATURE AND DURATION OF POST-IRRADIATION STORAGE ON SEEDLING HEIGHT OF WHEAT (감마선과 속중성자를 조사한 밀종자의 저장기간과 저장온도가 발아후 유묘생장에 미치는 영향)

  • Chang-Yawl Harn;Chi-Moon Kim;Young-Sang Kim
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.10
    • /
    • pp.73-77
    • /
    • 1971
  • The experiment was carried out to investigate post-irradiation storage effect which was related to temperature(i.e. at 2$^{\circ}C$, 17$^{\circ}C$ and 4$0^{\circ}C$) on wheat seeds; Weibull's Svenno, treated with gamma-ray and fast neutron. Results obtained showed that the seedling height in both radiation sources was decreased with prolongation of storage period, especially when the seeds were treated with high dosage and stored at high temperature(4$0^{\circ}C$). The results of this trial, however, showed that storage effect was influenced by irradiation dose, temperature and storage time.

  • PDF

Towards defining a simplified procedure for COTS system-on-chip TID testing

  • Di Mascio, Stefano;Menicucci, Alessandra;Furano, Gianluca;Szewczyk, Tomasz;Campajola, Luigi;Di Capua, Francesco;Lucaroni, Andrea;Ottavi, Marco
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1298-1305
    • /
    • 2018
  • The use of System-on-Chip (SoC) solutions in the design of on-board data handling systems is an important step towards further miniaturization in space. However, the Total Ionizing Dose (TID) and Single Event Effects (SEE) characterization of these complex devices present new challenges that are either not fully addressed by current testing guidelines or may result in expensive, cumbersome test configurations. In this paper we report the test setups, procedures and results for TID testing of a SoC microcontroller both using standard $^{60}Co$ and low-energy protons beams. This paper specifically points out the differences in the test methodology and in the challenges between TID testing with proton beam and with the conventional gamma ray irradiation. New test setup and procedures are proposed which are capable of emulating typical mission conditions (clock, bias, software, reprogramming, etc.) while keeping the test setup as simple as possible at the same time.

Development and Performance of a Hand-Held CZT Detector for In-Situ Measurements at the Emergency Response

  • Ji, Young-Yong;Chung, Kun Ho;Kim, Chang-Jong;Yoon, Jin;Lee, Wanno;Choi, Geun-Sik;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.87-91
    • /
    • 2016
  • Background: A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. Materials and Methods: To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. Results and Discussion: The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. Conclusion: The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

The Reclamation of Secondary Effluent to Industrial Water by Co-60 γ Irradiation (Co-60 γ선을 이용한 하수처리수의 공업용수로의 재이용)

  • Lee, Myun-Joo;Jeoung, Young-Do;Nho, Young-Chang;Shon, Jong-Sik
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.838-842
    • /
    • 1999
  • In order to reclaim the effluent discharged from sewage treatment facilities application of an irradiation technique was investigated in this study for industrial water reuse. Samples were filtered using a sand filter to remove particles. Co-60 was used as an irradiation source and the irradiation dose was varied from 0.1 kGy to 15 kGy. The major source of colour in secondary treatment effluent was humic substances, which could be easily removed by irradiation with a dose 5 kGy. Bacteria could be also disinfected even at low doses. It was possible to get high quality water for industrial water reuse. But the effluent still contained a small amount of organic compounds. Further treatment, of residual organic compounds will be necessry if the higher quality water is required.

  • PDF